INSTRUCTIONS FOR QUALIFIED PERSONNEL ONLY!

Similar documents
KMT - Kraus Messtechnik GmbH

Telemetrie-Messtechnik Schnorrenberg

KMT - Kraus Messtechnik GmbH

KMT - Kraus Messtechnik GmbH

KMT - Kraus Messtechnik GmbH

Telemetrie-Messtechnik Schnorrenberg

KMT - Kraus Messtechnik GmbH

Telemetrie-Messtechnik Schnorrenberg

KMT - Kraus Messtechnik GmbH

CTP16-Rotate. KMT - Kraus Messtechnik GmbH

KMT - Kraus Messtechnik GmbH

User Manual CTP4/8/16

Telemetrie-Messtechnik Schnorrenberg

MT32 Telemetry. KMT - Kraus Messtechnik GmbH. Multi channel telemetry system for rotating application. Powering (rotor) by battery or inductive

User Manual MTP Multi-channel telemetry system for rotating application, full software programmable with 16 bit resolution

Kraus Messtechnik GmbH

MTP-NT. Preliminary version Sophisticated multi-channel telemetry system for rotating application, fully software programmable with 16 bit resolution

MTP-NT INSTRUCTIONS FOR QUALIFIED PERSONNEL ONLY!

KMT - Kraus Messtechnik GmbH

SC-4/M User manual 4-channel measuring amplifier

Voice-Frequency Telegraph Modem HY101-SWT

alfa-clamp Tool Assembly Device

Series GLET Accessory for dataloggers series GL in modular enclosure

MANUAL. GPS Antenne. Antenna/Cnverer Unit Meinberg Radio Clocks GmbH & Co. KG

MX1615. Data sheet. Bridge/strain gauge amplifier

SAUTER HD Version /2015 GB

Isolation (ISO), Special Overvoltage functions protection (OP) Voltage measurement PAD-V8-P 8 Voltage, up to ±50 V BW: 6 Hz ISO: 350 V DC

MX1615B-R. Ultra-rugged Bridge Amplifier. Special features. Data sheet. Block diagram

MX440A. Data Sheet. Universal amplifier. Special features. Block diagram Digital platform. B en

Wind Transmitter First Class

Wind Transmitter First Class Advanced Classified according to IEC ( )

Modular Smart Interfaces

FC Series Signal Conditioners

Kistler LabAmp. Electronics & Software. Charge Amplifier and Data Acquisition Unit for Dynamic Measurements. Type 5165A...

MX1616B. Strain gauge bridge amplifier. Special features. Data sheet. Block diagram

20 General technical data XI/ON

Temperature Transmitters - Head Mounted

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

Wind Direction Transmitter First Class analogue output x0.1xx

ICAM. Electronics & Software. Industrial Charge Amplifier for Applications in Manufacturing. Type 5073A...

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

Let`s get SIRIUS! SIRIUS Overview. SIRIUS from Dewesoft. SIRIUS Overview. The new hardware generation makes your measurement more precise!

CANHEAD. Data Sheet. Special features. Distributed measurement acquisition. B en

Analogue temperature controllers

Model 140 Inline Amplifier

MX1615B. Strain gauge bridge amplifier. Special features. Data sheet. Block diagram

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

Temperature Input Module for Zone 1 Series 9482/32

MX1615B R. Data Sheet. Ultra-rugged Bridge Amplifier

MX840B R. Data sheet. Ultra-rugged universal amplifier CAN. Special features. Block diagram. B en

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5

EPAD2/CPAD2/CPAD3 Modules. Modules with CAN or RS-485 Interface

Let`s get SIRIUS! SIRIUS Overview. SIRIUS from Dewesoft. SIRIUS Overview. The new hardware generation makes your measurement more precise!

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Temperature Transmitters - DIN Rail Mounted

LENORD. +BAUER... automates motion. GEL 295x Customer-specific precision encoder. Technical Information Version General information.

Isolated DIN Rail Mount Loop-Powered 2-Wire Signal Conditioners. DRLP Series

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

ISOBE5600. Data sheet. Isolated Probe Systems. - ISOBE5600 Isolation system - ISOBE5600 Transient recorder. Features and Benefits

Instruction Manual. Charge Amplifiers. M68 Series. Manfred Weber

T40FM. Data Sheet. Torque flange. Special features. Overall concept. B en

Calibration and Testing

CSM High-Voltage Measurement Systems

INSTRUCTION MANUAL VIBRATION SWITCH CVS 100 LC

MX1601B-R. Ultra rugged Standard Amplifier. Data sheet. Special features. Block diagram

Analogue temperature transmitter Model T91.10, head mounting version DIN form B Model T91.20, head mounting version form J

ISOLATED 4-20 ma TRANSMITTERS

High-precision process calibrator Model CED7000

ARD154. DIN rail mountable amplifier for strain gage sensors. User s guide. User s guide ARD CONNECTING 4-WIRE SENSORS

The Rosemount 848T Wireless Temperature Transmitter

imc CANSAS-L-HCI8. High isolated module for the capture of temperature, voltage, current (20 ma) and resistance

MX440B. Data Sheet. Universal amplifier. Special features. Block diagram Digital platform. B en

M70LL Laser Distance Sensor

CAEMAX D x telemetry. digital modular convenient. Modular, multi-channel telemetry system for a variety of applications. productive testing

GREEN PRODUCT It has been RoHS Compliant SDR-2716 WT-716/WM-716 VHF PLL 16 CHANNEL WIRELESS SYSTEM OPERATING MANUAL

JUMO Wtrans Receiver Universal Receiver for JUMO Wireless Measuring Probes

Kistler LabAmp for DynoWare

MX1601B R. Data Sheet. Ultra-rugged Standard Amplifier

Economical Digital Indicators For Process and Electrical Measurement

JUMO dtrans T04 Four-wire Transmitter, settable via DIP switch/pc setup program

Hand-held temperature calibrator Model CEP3000

CONTA-ELECTRONICS. Converter Units

P5201 Universal Programmable Transmitters with Galvanic Isolation

MX840B. Data Sheet. Universal amplifier CAN. Special features. Block diagram. B en

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER

Module Input type Ranges TEDS Filters (LP = lowpass, HP = highpass) Piezoresistive bridge ±0.5 to mv/ma 1 ma exc

WIND VANE THIES FIRST CLASS 2014 TMR

Thermocouple - Transducer

ELECTRONIC DESIGN & ENGINEERING. ICP_FM3 Versatile DC AC IEPE Signal Conditioning. 1 ICP_FM3 Introduction

Process displays For standard signals, temperature, resistance measurement

Precipitation Monitor ,

MX1615B. Data sheet. Bridge/strain gauge amplifier

MX410B. Highly dynamic universal amplifier. Data sheet. Special features. Block diagram

EPAD2/CPAD2/CPAD3 Modules. Modules with CAN or RS-485 Interface

Transmitter for temperature and direct current variables in four-wire circuit. Contrans T TEU 315, TEU 315-Ex, TEU 325, TEU 325-Ex 11-3.

SEM1600T RTD/TC/SLIDE WIRE SIGNAL CONDITIONER

Head mounted Temperature Transmitter TF02/TF02-Ex

T10F. Data Sheet. Torque Flange. Special features. Installation example T10F. B en

Force and strain sensors. Measure. Test. Control. Edition 2016

Transcription:

KMT - Kraus Messtechnik GmbH Gewerbering 9, D-83624 Otterfing, Germany, 08024-48737, Fax. 08024-5532 Home Page: http://www.kmt-telemetry.com, Email: info@kmt-telemetry.com CT2-Mini User manual INSTRUCTIONS FOR QUALIFIED PERSONNEL ONLY!

General functions: DC power cable DEC CT2-Mini Decoder/ Receiver 2 x s 2m DC power cable ENC AC/DC power supply for Decoder (Option) Receiving 1x antenna Diversity receiver contain 2x antenna! CT2-Mini Encoder/ Transmitter Hexagon screw driver to open the CT-Mini-ENC CT2-Mini Telemetry system with accessories CT2-Mini is a 2-channel telemetry system designed for easy mounting onto rotating and moving parts to provide non-contact transmission of measured parameters such as pressure, force, temperature, acceleration and voltage. Also for point to point application like bridge or buildings testing, you can install CT2 Mini instead long cables from the sensor to the Computer. Sensors inputs are connected via screw on, waterproof connectors. Measured values are prepared in analog format, digitized and transmitted via radio frequencies. Different carrier frequencies are provided, this allows up to four systems to operate in parallel. The complete transmitter assembly is waterproofed to IP65 specifications. The following sensors can be connected to the system: (STG) Strain gages sensors in full-, and half- bridge configuration (350 ohm or greater), Type K Thermocouples to 1000 C, ICP, potentiometers sensors and capacitive sensors. Voltage inputs of +/-5V and +/-10V are available. The measured values are processed and output as +/-5V analog signals at the BNC sockets (optional digital output for special PCM interface into a PC) on the stationary receiver. Resolution of 12 bits is standard; this enables an amplitude dynamic of 72 db. The analog signal bandwidth is up to 12000Hz (see table). The measurement accuracy is +/-0.25 % (without sensor). The CT2-Mini is suited for operation at ambient temperatures of -20 to +70 C. The transmission distance between transmitter and receiving antenna is of the order of 250* m (*40kbit with10mw transmitting power non diversity) With diversity only 100m range Cut off frequency from anit-aliasing filter scanning rate (see red) Bit rate per channel 40 kbit/s 375 Hz (-3dB) (1428 Hz) 320 kbit/s 3000 Hz (-3dB) (11428 Hz) 640 kbit/s 6000 Hz (-3dB) (22857 Hz) 1280 kbit/s 12000 Hz (-3dB) (45714 Hz) Version 2016-01 2 Technical Data are subject to change without notice!

CT2 Mini Transmitting Unit Technical Data (Encoder) Sensor inputs Antenna (TNC) Power In 10-30V DC Untwist to open the housing CT-STG-V2: Sensor: Bridge completion: Excitation: strain gage, > 350 Ohms full and half bridge 4 VDC (fixed), short-circuit protection Gain: 250-500-1000-2000 selectable by solder jumpers (CT-STG-V1 only with Gain 200-1000 ) Offset Zero adjustment by potentiometer or optional Auto-zero function (which is not lost by power-off), offset range up to 80% of full scale. CT-ICP-V2: Constant current: Gain: Signal bandwidth: CT-POT: Sensor: Excitation: 4mA (fixed) 2x, 4x, 8x, 16x or 32x 3 Hz to 12000Hz (depended of transmitter!) Potentiometer Sensor >350 Ohms to 10kOhms 4 VDC (fixed) CT-TH-K-ISO: Sensor: thermo-couple, type K ( with cold junction compensation) measuring range: -50 C to +1000 C (other on request) with galvanic isolation, Accuracy 1% Signal bandwidth: 0...10 Hz -3dB CT-PT100: Sensor: measuring range: CT-VOLT: High-level inputs: resistance temperature detectors (RTDs) with resistance of 100 ohm -100 C to +500 C +/- 5 Volt or +/- 10 Volt System Parameters: Channels: 2 Resolution: Line-of-sight distance with diversity telemetry: Line-of-sight distance with non-diversity telemetry: Powering: Power consumption: Analog signal bandwidth: Transmission: Transmission Power: Dimensions: Weight: Operating temperature: Housing: Humidity: Vibration: Static acceleration: Shock: 12 bit A/D converter with anti aliasing filter, simultaneous sampling of all channels 200m with 40kbit, 150m with 320/kbit, 100m with 640kbit, 50m with 1280kibt (free view) 500m with 40kbit (free view) 10-30 Cut V off DC frequency from anit-aliasing filter 100 ma at (-3dB) 12V using and 2 STG scanning sensors rate 350 (red) Ohms Digital PCM Miller Format 10mW 102 x 68 x 41 mm (without connectors) 0.45 kg without cables - 20 +70 C Bit rate 1280 kbit/s 640 kbit/s 320 kbit/s 40 kbit/s Aluminum anodized, waterproofed (IP65) 20... 80% no condensing 5g Mil Standard 810C, Curve C 100g in all directions 200g in all directions 2 Channels 12000 Hz (45714 Hz) 6000 Hz (22857Hz) 3000 Hz (11428 Hz) 375 Hz (1428 Hz) Version 2016-01 3 Technical Data are subject to change without notice!

Front view Technical data: Receiving Unit CT2-Mini DEC (Decoder) BNC socket for analog signal outputs 1 2 TNC-socket for receiving antenna Back view 7- pole TUCHEL-socket for Voltage supply cable (10 30V) TNC-socket for receiving antenna Optional at diversity with active LED Field strength indicator Power ON LED Sync-Loss Indicator LED shine at bad transmission ON/OFF switch System Parameters: Channel: Resolution: Dynamic: Receiver Power supply input: Current consumption: Frequencies: Dimensions: Weight: Overall system accuracy between encoder input and decoder output: Environmental Operating: Humidity: Vibration: Static acceleration: Shock: 2 analog outputs via (BNC) +/-5V 12 bit D/A converter, with smoothing filter 72dB 40kbit standard with not diversity receiver 40kbit, 320kbit, 640kbit and 1280kbit with diversity receiver incl. two receiving antennas! 10-30 VDC 300mA at 10V, 100mA at 30V up to 4 different carrier frequencies available 105 x 105 x 65mm 0.60 kg without cables and antenna +/-0.25% without sensor influences -20 +70 C 20... 80% not condensing 5g Mil Standard 810C, Curve C 10g in all directions 100g in all directions Version 2016-01 4 Technical Data are subject to change without notice!

Connection, STG bridge configuration: (encoder) Black = IN - White = IN + Brown = +EXC Blue = --EXC Sensor socket STG module Type: Strain gage >350 Ohms Excitation: 4 VDC (fixed) Gain: 200 or 1000 Accuracy +/- 0.25% + IN + EXC -- IN -- EXC 1/1 or 1/2 Bridge setting Zero via Potentiometer (standard) Auto Zero Switch (option) Only for STG Antenna OUT (TNC) Powering 10-30VDC NC CT-STG-Version V1 Gain 200 or 1000 by solder bridge Gain 1000 Gain 200 CT-STG-Version V2 Gain 250-500-1000 or 2000 by jumper or on request 1000-2000-4000-8000 Gain 1000-2000-4000-8000 on request! Version 2016-01 5 Technical Data are subject to change without notice!

Connection CT-POT: Black = Blue = Brown = +4V White = IN *NC= not connected Sensor socket CT-POT module for potentiometer sensors IN +4V NC CT-POT (=special type off STG) Type: Potentiometer >350Ohm to 10kOhm Excitation: 4 VDC (fixed) Accuracy +/- 0.25% Attention: The POT modules must be configured as a Half Bridge Unit. Don t change offset and gain!! Half bridge setting Connection CT-Volt module Black = IN +/- White = Brown = Blue = *NC= not connected IN +/- Sensor socket CT-Volt Type: Volt Range: +/-5 or +/-10V Accuracy +/- 0.25% Attentions: At Volt modules must plug the plug bridge on Half Bridge Unit. Don t change offset!! Half bridge setting +/-10V +/-5V Version 2016-01 6 Technical Data are subject to change without notice!

Connection CT-ICP module Black = IN +/- White = Brown = Blue = *NC= not connected IN +/- Sensor socket Gain: 32 16 8 4 2 CT-ICP Type: ICP Signal bandwidth: 3Hz to (see table) Gain: 2x, 4x, 8x, 16x or 32x Optional: 16x,32x,64x,128xor 256x Constant current: 4mA (fixed) Accuracy +/- 0.25% Half bridge setting Attentions: At ICP modules must plug the plugbridge on Half Bridge Unit. Connection CT-Pt100 module (RTDs) Black = IN Connected with brown White = Connected with Blue Sensor socket IN IN CT-Pt100 Type: RTD 100 ohm Range: -100 to 500 C Accuracy +/- 0.25% Attentions: At Pt100 modules must plug the plug bridge on Half Bridge Unit. Half bridge setting -100-0,997 150 1,500 400 4,004-50 -0,497 200 2,001 450 4,498 0 0,001 250 2,501 500 4,999 50 0,499 300 3,001 100 1,000 350 3,501 Version 2016-01 7 Technical Data are subject to change without notice!

Connection TH-K ISO Thermo couple Black = IN +/- White = Brown = Blue = *NC= not connected IN + Sensor socket CT-THK-ISO - Galvanic isolated! Type: K Range: -50 C 1000 C Bandwidth: 0-20Hz (more on request) Accuracy +/-1% Half bridge setting Attentions: At Thermo couple must plug the plug bridge on Half Bridge Unit. -50-0.220 250 1.236 550 2.754 850 4.262 0 0.013 300 1.482 600 3.010 900 4.506 50 0.254 350 1.734 650 3.266 950 4.746 100 0.504 400 1.990 700 3.519 1000 4.980 150 0.752 450 2.242 750 3.700 200 0.992 500 2.498 800 4.015 Version 2016-01 8 Technical Data are subject to change without notice!

Dimensions of CT2-MINI-ENC Version 2016-01 9 Technical Data are subject to change without notice!

Kraus Messtechnik GmbH Gewerbering 9, D-83624 Otterfing, +49-8024-48737, Fax. +49-8024-5532 Germany Home Page http://www.kmt-gmbh.com E-mail: info@kmt-gmbh.com Konformitätserklärung Declaration of Conformity Declaration de Conformité Wir We Nous Anschrift Address Adress KMT - Kraus Messtechnik GmbH Gewerbering 9, D-83624 Otterfing, Germany erklären in alleiniger Verantwortung, daß das Produkt declare under our sole responsibility, that the product declarons sous notre seule responsibilité, que le produit Bezeichnung Name Nom Typ,Modell,Artikel-Nr., Größe Type,Model, Article No.,Taille Type, Modèle, Mo.d'Article,Taille Messdatenübertragungssystem CT2, CT4, CT8, CT16 mit den Anforderungen der Normen und Richtlinien fulfills the requirements of the standard and regulations of the Directive satisfait aux exigences des normes et directives 108/2004/EG Elektromagnetische Verträglichkeit EMV / EMC DIN EN 61000-6-3 Ausgabe 2002-8 Elektromagnetische Verträglichkeit EMV Teil 6-3 Fachgrundnorm Störaussendung DIN EN 61000-6-1 Ausgabe 2002-8 Elektromagnetische Verträglichkeit EMV Teil 6-1 Fachgrundnorm Störfestigkeit und den angezogenen Prüfberichten übereinstimmt und damit den Bestimmungen entspricht. and the taken test reports und therefore corresponds to the regulations of the Directive et les rapports d'essais notifiés et, ainsi, correspond aux règlement de la Directive. Otterfing, 30.05.2006 Martin Kraus Ort und Datum der Ausstellung Place and Date of Issue Lieu et date d'établissement Name und Unterschrift des Befugten Name and Signature of authorized person Nom et signature de la personne autorisée Version 2016-01 10 Technical Data are subject to change without notice!