ESA400 Electrochemical Signal Analyzer

Similar documents
Potentiostat/Galvanostat/Zero Resistance Ammeter

Quick Check of EIS System Performance

Defining High Performance Electrochemistry...

Measuring Batteries using the Right Setup: Dual-cell CR2032 and Battery Holder

Interface 5000 Potentiostat/Galvanostat/Zero-Resistance Ammeter

Module 1: Introduction to Experimental Techniques Lecture 2: Sources of error. The Lecture Contains: Sources of Error in Measurement

2015 HBM ncode Products User Group Meeting

Advanced Test Equipment Rentals ATEC (2832)

Phase Noise Measurement Personality for the Agilent ESA-E Series Spectrum Analyzers

potentiostat/galvanostat/impedance analyser

Laboratory Experiment #1 Introduction to Spectral Analysis

Reference 3000 Potentiostat/Galvanostat/ZRA

Testing Electrochemical Capacitors Part 3: Electrochemical Impedance Spectroscopy

multi-channel Potentiostat / Galvanostat / Impedance Analyzer Rev

Noise Measurements Using a Teledyne LeCroy Oscilloscope

Compliance Voltage How Much is Enough?

Advanced Lab LAB 6: Signal Acquisition & Spectrum Analysis Using VirtualBench DSA Equipment: Objectives:

What the LSA1000 Does and How

RECOMMENDATION ITU-R SM * Measuring of low-level emissions from space stations at monitoring earth stations using noise reduction techniques

SHOCK AND VIBRATION RESPONSE SPECTRA COURSE Unit 4. Random Vibration Characteristics. By Tom Irvine

potentiostat/galvanostat

Advanced Digital Signal Processing Part 2: Digital Processing of Continuous-Time Signals

Potentiostat / Galvanostat / Impedance Analyzer

Gentec-EO USA. T-RAD-USB Users Manual. T-Rad-USB Operating Instructions /15/2010 Page 1 of 24

ABB flowmeter technology FSM4000 AC-excited magmeter

Advanced Data Analysis Pattern Recognition & Neural Networks Software for Acoustic Emission Applications. Topic: Waveforms in Noesis

Impulse response. Frequency response

Chapter 2 Analog-to-Digital Conversion...

173 Electrochemical Impedance Spectroscopy Goals Experimental Apparatus Background Electrochemical impedance spectroscopy

Tender Document. National Centre of Excellence in Analytical Chemistry, ISSUED BY: University of Sindh, Jamshoro.

New Features of IEEE Std Digitizing Waveform Recorders

Capacitive MEMS accelerometer for condition monitoring

CLIO Pocket is Audiomatica's new Electro-Acoustical Multi-Platform Personal measurement system.

Technical note. Impedance analysis techniques

CH Instruments, Inc. Electrochemical Instrumentation

Developer Techniques Sessions

ME scope Application Note 01 The FFT, Leakage, and Windowing

The Fundamentals of FFT-Based Signal Analysis and Measurement Michael Cerna and Audrey F. Harvey

UNIT-4 POWER QUALITY MONITORING

Chapter 2: Digitization of Sound

USE OF BASIC ELECTRONIC MEASURING INSTRUMENTS Part II, & ANALYSIS OF MEASUREMENT ERROR 1

Frequency Domain Representation of Signals

Today most of engineers use oscilloscope as the preferred measurement tool of choice when it comes to debugging and analyzing switching power

Electrochemical Impedance Spectroscopy and Harmonic Distortion Analysis

Panasonic, 2 Channel FFT Analyzer VS-3321A. DC to 200kHz,512K word memory,and 2sets of FDD

Signal Processing for Digitizers

11Beamage-3. CMOS Beam Profiling Cameras

Measurement Techniques

The ArtemiS multi-channel analysis software

Solartron CellTest System

USB Dynamic Signal Acquisition

Potentiostat / Galvanostat / Impedance Analyzer

Testing Sensors & Actors Using Digital Oscilloscopes

FFT Analyzer. Gianfranco Miele, Ph.D

Data. Dr Murari Mohan Saha ABB AB. KTH/EH2740 Lecture 3. Data Acquisition Block. Logic. Measurement. S/H and A/D Converter. signal conditioner

Image Enhancement in Spatial Domain

3D Distortion Measurement (DIS)

VersaSTAT Series. potentiostat/galvanostat

VMP-300. The ultimate electrochemical workstation MULTICHANNEL POTENTIOSTAT/GALVANOSTAT/EIS APPLICATIONS. EC-Lab products

Laboratory Battery Testing Systems for Cell Applications

For Isotropic Measurement of Magnetic and Electric Fields

EIS Measurement of a Very Low Impedance Lithium Ion Battery

Potentiostat / Galvanostat / Impedance Analyzer

SigCalRP User s Guide

UNIT-3. Electronic Measurements & Instrumentation

VersaSTAT Series. potentiostat/galvanostat

Efficacy of Wavelet Transform Techniques for. Denoising Polarized Target NMR Signals

Characterizing High-Speed Oscilloscope Distortion A comparison of Agilent and Tektronix high-speed, real-time oscilloscopes

SigCal32 User s Guide Version 3.0

EE 791 EEG-5 Measures of EEG Dynamic Properties

8.2 Common Forms of Noise

OASIS. Application Software for Spectrum Monitoring and Interference Analysis

Using Frequency Diversity to Improve Measurement Speed Roger Dygert MI Technologies, 1125 Satellite Blvd., Suite 100 Suwanee, GA 30024

ADC Based Measurements: a Common Basis for the Uncertainty Estimation. Ciro Spataro

note application Measurement of Frequency Stability and Phase Noise by David Owen

Enhanced Sample Rate Mode Measurement Precision

ACE. SignalCalc. Ultra-Portable, Cost-Effective Dynamic Signal Analyzer. 4 input channels, 2 sources. High Speed Tachometer. 120 db dynamic range

Statistical Analysis of Modern Communication Signals

771 Series LASER SPECTRUM ANALYZER. The Power of Precision in Spectral Analysis. It's Our Business to be Exact! bristol-inst.com

Four-Channel Sample-and-Hold Amplifier AD684

JTA2. Jitter & Timing Analysis. Operator s Guide

Subject: Best Practices for Improving Tafel Plots of High Capacitance Cells with Low Series Resistance

Jitter Analysis Techniques Using an Agilent Infiniium Oscilloscope

OptiEIS : A Multisine Implementation

M Hewitson, K Koetter, H Ward. May 20, 2003

Setting up a Multi sine impedance measurement

Swept Wavelength Testing:

Solutions to Information Theory Exercise Problems 5 8

Oscilloscope Measurement Fundamentals: Vertical-Axis Measurements (Part 1 of 3)

CHAPTER. delta-sigma modulators 1.0

Making sense of electrical signals

NON-SELLABLE PRODUCT DATA. Order Analysis Type 7702 for PULSE, the Multi-analyzer System. Uses and Features

Instrumental Considerations

SIGNAL RECOVERY. Model 7265 DSP Lock-in Amplifier

Ethernet-Based Temperature, Voltage and Strain Measurement Modules

Universal Dummy Cell 3. Operator's Manual

SP-300. Breakthrough technology in a new generation of Super-Potentiostats... Fast, sensitive, stable and modular a remarkable combination!!!

Introduction. Chapter Time-Varying Signals

Agilent AN 1275 Automatic Frequency Settling Time Measurement Speeds Time-to-Market for RF Designs

Removal of Continuous Extraneous Noise from Exceedance Levels. Hugall, B (1), Brown, R (2), and Mee, D J (3)

Transcription:

ESA4 Electrochemical Signal Analyzer Electrochemical noise, the current and voltage signals arising from freely corroding electrochemical systems, has been studied for over years. Despite this experience, it often suffers from invalid data acquisition and inconsistent analysis. The ESA4 Electrochemical Signal Analyzer is designed to address both the past problems and the future needs of electrochemical noise measurements. Its primary goal is to assist in the evaluation of noise as a technique for the routine study of chemical processes by providing a convenient package for versatile data acquisition and sophisticated data analysis. Data Acquisition in the ESA4 For acquisition, the ESA4 partners with any of three Gamry Potentiostats to generate reliable data in either potentiostatic, galvanostatic, or zero resistance ammeter (ZRA) mode. Careful attention is paid to sample continuity, acquisition rate, filtering, and autoranging to provide the most accurate signal representation. To transform the noise into information, the ESA4 provides an impressive package of signal analysis tools: blockwise statistics, Fourier and MEM frequency domain analysis, correlation analysis, histograms, and the powerful JFTA (Joint Time- Frequency Analysis). These algorithms can be used to calculate quantitative results from the data. When there is information buried in electrochemical noise, the ESA4 gives you the power to find it. Acquisition in potentiostat, galvanostatic, zero resistance ammeter, or biased zero resistance ammeter modes Wide range of data acquisition frequencies Unlimited data acquisition length Full complement of signal processing techniques Real-time display of mean, RMS, sigma, variance, skewness, kurtosis, instantaneous resistance (E/I), and FFT Features Matched linear phase anti-aliasing filters Flexible real-time charting with zoom and pan Adjustable length buffer for post acquisition analysis Up to 4 simultaneous acquisitions Complete import and export capability Current and voltage autoranging Synthesized white noise for spectral analysis

Electrochemical oise Overview Various physical and chemical processes can give rise to seemingly random low-frequency signals. These phenomena include pitting and crevice corrosion, uniform corrosion, coating failure, inhibitor activity, cracking, passive film stability, adsorption, and gas generation. The potential and/or current fluctuations from these stochastic processes, taken as a group, are referred to as electrochemical noise. oise signals may be acquired in several ways. Performing the experiment with two identical electrodes under open-circuit conditions with a Zero Resistance Ammeter/Electrometer allows a measurement to be made with no external perturbation, closely simulating ambient real-world conditions. Both potential and current can be measured simultaneously. The ESA4 can also be used in our unique Biased ZRA mode. Imposing a potential between two identical electrodes tends to move the anodic corrosion processes to the positively polarized electrode. This insures that more of the relevant current is measured. It also provides a useful way to electrochemically stress a material to measure its resistance to localized corrosion. Some researchers find it advantageous to study the system under either potentiostatic or galvanostatic control to accelerate a particular process such as passivation. In this case, the current and potential, respectively, are monitored versus time. The ESA4 allows both potentiostatic and galvanostatic control in addition to ZRA mode. Data Acquisition Done Right Three Electrode Biased ZRA/Electrometer The ESA4 can also apply a computer-generated white noise signal to the system under test. While this may seem an anomaly for an electrochemical noise instrument, it is useful for improving the performance of the instrument when used for impedance analysis. In all cases, it is extremely important to differentiate the signals generated by the chemical process from the electronic noise of the instrument. We pay special attention to maintaining data integrity by using filters tuned to the sampling rate according to the yquist antialiasing criterion, which states that signals at frequencies greater than ½ the sampling frequency will appear as lower frequencies. High frequency computer noise is effectively eliminated in the ESA4 by a series of analog and digital filters. The filters are designed to be linear in phase, insuring that peak shapes and higher order statistical moments are not distorted. White oise Sampled at 1 Hz Filtered (Red Dots) vs Unfiltered (Blue)

The Right Hardware for Signal Analysis Electrochemical noise signals are often very small. The ESA4 utilizes the offset and gain capability of the Gamry PC4 Potentiostat family to achieve 1 µv and 1 fa resolution to observe even the most subtle interactions. Think of this as using a magnifying glass to zoom in on a relatively stationary portion of your signal. A unique DC offset circuit subtracts out the background level so you can subsequently apply a final amplification of x1, x1 or x1. Offset and gain are calculated and adjusted continuously in the background during the data acquisition. To eliminate switching transients, a single potentiostat is dedicated to gathering data for one sample. To increase the productivity of your laboratory, the ESA4 can control up to four potentiostats simultaneously, each running an independent noise experiment with different potentiostat ranges and settings. Tools for Signal Analysis Researchers are still studying signal analysis techniques to determine which are the most useful. To help you decide, we ve supplied the ESA4 with a versatile, inclusive collection of mathematical tools for signal analysis. Data from noise experiments is acquired in the time domain, i.e., current and/or potential is measured Real-Time Statistics To help you recognize when a significant event has occurred, the ESA4 continuously calculates several statistics on the I and V data streams. In addition a real-time FFT can be calculated. The statistical functions are calculated on user-specified blocks of The time scale of an electrochemical noise measurement is difficult to predict. Accordingly, the ESA4 has been designed to monitor potential and current signals continuously in an uninterrupted fashion. If you wish, you can collect data for months! This way, you won t miss any long-term events that may require an initiation period. You are literally limited only by the free space on your hard drive! To conserve space on your hard drive, we save the data as a binary file of voltage and current records. The data can be collected at a selectable sampling rate from 1 Hz to.1 Hz. The choice of data acquisition rate is dependent on the time scale of the phenomena being studied. Electrochemical Impedance Spectroscopy performed using the Gamry EIS3 is an excellent method to identify an appropriate sampling frequency. versus time. For analysis, it is often convenient to convert this data into the frequency domain in which a function of the signal amplitude is plotted versus frequency. This spectral representation can be accomplished with the Fast Fourier Transform (FFT) or the Maximum Entropy Method (MEM) approximation. raw data ranging from 3 to 16,384 data points per block. Up to four of the following calculations can be displayed in real time, one per screen quadrant. The same statistics may also be calculated on previously acquired data stored in files. V & I vs. Time: x [ vs t[ Block Average: x = 1 i= RMS: x rms = x[ Standard Deviation*: x σ = ( x[ x) 1 var ] i= 1 1 i= x[ 1 i= 1 ] 3 σ i= Variance*: x = ( x[ i x) Skewness: x = ( x[ i x) skew x 3 1 ] 4 σ i= Kurtosis: x = ( x[ i x) kurt x 4 V Resistance: R σ n = ; I σ I A σ n = V σ FFT: 1 i= jπ k X[ k] = x[ e * Population-based definition

Fourier Transform The Fourier Transform in the Analysis section provides the same analysis as in the Real-Time FFT. You may choose the width of the region being analyzed, the Joint Time-Frequency Analysis (JTFA) resolution, and the appropriate smoothing window to eliminate edge effects. The ESA4 introduces the Joint Time-Frequency Analysis, a powerful visual technique, for viewing and summarizing electrochemical noise data. Traditionally, signals have been analyzed in either the time or the frequency domain. JTFA analyzes signals in both time and frequency domain at the same time. The amplitude of a signal is plotted as an intensity plot with the X-axis corresponding to time and the Y-axis corresponding to frequency. In addition, the JFTA shows the original time series data and either instantaneous or overall spectra of the current and voltage signals for a powerful one chart summary of your signals. JTFA on Active Pitting to Crevice Corrosion i i Power Spectral Density, Fourier Transform This method gives the energy of the voltage and current signals occurring at a given frequency. It also gives the ratio of the two power spectra. The power of the voltage signal is defined by: P V ( f ) = Vˆ( f ) where Vˆ is the Fourier transform of the signal. Power Spectral Density, Maximum Entropy Method The Power Spectral Density (PSD) when calculated via a Fourier Transform tends to be noisy at high frequencies. The MEM algorithm smoothes the PSD by fitting a time-domain signal of the form:. The order, M, of the MEM can be adjusted. V smooth M [] i = k = 1 a V k sm

Cross Correlation Analysis This analysis shows the correlation between the current and voltage signals. It is defined as the Fourier Transform of the cross correlation function: R 1 I, V * k = ( m) = V [ k + m] I[ m] where m measures the time interval, e.g., m sample periods between the two signals. When two signals are highly correlated, R I,V increases as m decreases. Correlated V and I signals indicate that they are probably coupled through the electrochemical interface and, therefore, associated with electrochemical processes. Impedance Spectrum The impedance spectrum is by now well known to electrochemists and corrosion scientists. The ESA4 calculates an impedance by ratioing the frequency domain representation of the voltage signal to that of the current signal. Both MEM and FFT spectra are calculated. Quite often, however, there is not enough Histogram Analysis The histogram is a plot of the number of points at a given voltage or current for the entire data record. It is noise present in laboratory environments to generate meaningful spectra. To obtain better accuracy in impedance spectrum, the ESA4 can apply a computer-generated white noise signal to the system under test. the distribution function on which the various statistical calculations are based. Peak Finding and Counting The ESA4 can count the number of excursions above or below a limit. This analysis is often used to characterize localized corrosion processes. The minimum width of peaks or valleys can be specified. Linear Detrending Often it is handy to remove a background drift in voltage or current. This is done by fitting a straight line to the data set and subtracting it from each data point. Linear Detrending is typically performed prior to calculation of the RMS value of the data. Data ormalization Used to compare two non-identically scaled data sets, Data ormalization transforms each set to an equivalent set with a mean of and standard deviation of 1. In this way, multiple data sets can all be plotted on the same normalized axes for ease of comparison. Data Import / Export The Analysis features of the ESA4 can even be applied to data acquired with non-gamry potentiostats. Data files in a tab delimited format can be conveniently imported into the ESA4 and processed normally. Data can also be exported from the ESA4 in a tab delimited format to spreadsheets, databases, or other software packages.

Software Specifications Acquisition Modes Acquisition Frequencies Data Display Data Block Size for Statistical and FFT Calculations Data Analysis Modes Data Overlay Zero Resistance Ammeter, Biased Zero Resistance Ammeter, Potentiostatic, Galvanostatic.1 to 1 Hz at 13 discrete frequencies User selectable to display any or all of: Mean, RMS, Sigma, Variance, Skewness, Kurtosis, Instantaneous Resistance (E/I), and FFT 3 to 16,384 points Joint Time-Frequency Analysis, Power Spectral Density, Real-Time FFT, Cross Correlation, Histogram Analysis, Real-Time Statistical Analysis, Peak Finding and Counting, Linear Detrending, Data ormalization, Impedance Spectra Up to six files with an option for normalization Electronic Specifications The electronic specifications for the ESA4 Electrochemical Signal Analyzer depend on the system's potentiostat. Consult Gamry Instrument s Potentiostat Brochure for detailed specifications. Systems Information The ESA4 Electrochemical Signal Analyzer requires a Gamry PC3, PC4, or FAS1 Potentiostat to acquire data. Microsoft Windows 95/98 is required for operation of the ESA4. The ESA4 requires a computer with a MHz or higher processor and a minimum 3 Mb RAM (4 MHz and 18 Mb RAM recommended). ESA4 packages are subject to a limited 1-year factory service warranty (Gamry Instruments software and components only). The ESA4 is YK compliant. Computers and computer accessories are subject to the computer vendor's warranty. Gamry Instruments supplies complete systems including the above items installed in a Pentium-based desktop or portable computer. Custom computer configurations, software, training and installation are available by special order. Contact us for further details on these systems. ESA4 Version 1. 4/15/99 Copyright 199-99 Gamry Instruments. All specifications subject to change without notice. 734 Louis Drive Warminster, PA 18974 +15-68-933 Fax: +15-68-9331 info@gamry.com www.gamry.com