Rheinland Product Safety e Switching Power Suly Universal AC 3 hases inut full range Can also be used as single hase 480VAC Installation on DIN rail 7.5 or 15mm PFC as standard High efficiency u to 91% Power ready outut Parallel connection feature Comact dimensions UL, cul listed and TUV/CE Product Descrition Ordering Key SP D 24 480 3 The Switching ower sulies SPD series are secially designed to be used in all automation alication where the installation is on a DIN rail and comact dimensions and erformance are a must. Model Mounting ( D = Din rail ) Outut voltage Outut ower Inut Tye Arovals Inut tye: 3 = three hase (or single hase 400/500VAC 3) ) B a u a r t g e r ü f t T y d e a r o v Outut erformances Model Outut Voltage Trim DC OK Thereshold DC low LED Thereshold Rated outut Outut Tyical Current Range 1) at startu (VDC) after startu(vdc) Voltage (VDC) Power (W) Efficiency (A) 1) Min. VDC Max. VDC Min. Max. Min. Max. SPD24 20 (15) 22.5 28.5 17.6 19.4 17.6 19.4 90% SPD48 10 (7.5) 47.0 56.0 37.0 43.0 37.0 43.0 91% 1) When owered with three hases inut; with bihase inut value is in the brackets. 2) When S/P switch is set to arallel, it is not ossible to trim outut voltage. Outut data Line regulation ± 1% Load regulation Non arallel mode ± 1% Parallel mode ± 5% Ouut Voltage accuracy from 0 to +1% (factory adjusted) Rile and Noise 100mV Temerature Coefficient +0.02% / C Hold u time Vi = 230Vac 20ms Minimum load 0% Parallel Oeration 2 units max. (only with S/P switch on P osition) Inut data Rated inut voltage 400/500VAC Voltage range AC in 340-575VAC 3) DC in 480-820VDC Rated inut current (380/500) 1.4A / 1.0A 3) Bihase or trihase inut (bihase can be: L1 L2, L2 L3 or L1 L3. Note: when used as bihase, the maximum outut ower is 75% of rated ower. Frequency range 47-63 Hz Inrush current 15A P.F.C. Vi= 500VAC, Io nom. 0.7 1
Switching Power Suly Controls and Protections Inut Fuse 3.15A/250VAC internal/hase 4) Overvoltage ProtectionSPD24 30 33VDC SPD48 60 68VDC Outut Short Circuit Continous Current limit Discontinous Delay 3s shut-down, after 30s Auto-restart Rated Overload Protection 115-135% 4) Not relaceable by user. Power ready outut (only SPD 24) Threshold voltages 17.6-19.4VDC Contact rating at 60Vdc 0.3A insulation 500VDC Overtemerature 100-110 C (shutdown with auto-restart when temerature is back to normal) General data (@ nominal line, full load, 25 C ) Ambient temerature -25 C to 71 C Derating (>61 C to +71 C) 2.5%/ C Ambient humidity 20-95%RH Storage -25 C to +95 C Dimensions L x W x D Screw terminal tye 124 x 150 x 118 mm 1.88 x 5.91 x 4.65 inches Cooling MTBF (MIL-HDBK-217F) Case material Weight Protection degree Free air convection n.a. Metal (owder ainted aluminium) 1750g / 61.73oz IP20 Arovals and EMC Insulation voltage I/O Insulation resistance I/O @ 500VDC UL / cul TUV 3.000VAC 100MΩ UL508 listed, UL60950-1, Recognized EN60950-1 CE EN61000-6-3 EN55022 class B EN61000-3-2 EN61000-3-3 EN61000-6-2 EN55024 Block diagrams L1 L2 L3 Fuse1 Fuse2 Fuse3 Bridge Rectifier P.F.C Circuit Switching Device Rectifier Current D etection Vo + Vo - Y PW M Controller Oto- Isolation Reference & Error Am. Single / Parallel Select Vout AD J. Oto- Isolation Over Voltage D etection Continuous / D iscontinuous M.C.U DC ON DC LOW RD Y 2
Switching Power Suly Pin assignement and front controls Pin No. Designation Descrition 1 + Positive outut terminal 2 + Positive outut terminal 3 - Negative outut terminal 4 - Negative outut terminal 5 GND Ground terminal to minimise High frequency emissions 6 L1 Inut terminals 7 L2 Inut terminals 8 L3 Inut terminals 9 RDY A normal oen relay contact for DC ON level control 10 RDY A normal oen relay contact for DC ON level control DC ON DC outut ready LED DC LO DC low indicator LED Vout ADJ. Trimmer for fine outut voltage adjustment S/P Single / arallel selection switch C/D Continous / Discontinous Installation Derating Diagram Ventilation and cooling Normal convection All sides 25mm free sace for cooling is recommended Screw connections 10-24AWG flexible or solid cable 8mm striing recommend Max. torque for screws terminals Inut terminals 1.008Nm (9.0lb-in) Outut terminals 0.616Nm (5.5lb-in) 75 Power out (%) 100 90 80 70 60 50 40 30 20 10 0-25/ -20/ -15/ -13-4 -5-10/ 14 Temerature C / F +50/ 122 Bihase +55/ 131 +60/ 140 +61/ 141.8 +65/ 149 +70/ 158 +71/ 159.8 +75/ 167 Mechanical Drawings mm/inches 150 (5.91) 111.3 (4.38) 106.6 (4.2) 6.9 (0.27) P 9 10 RDY C/D S/P RDY 123.6 (4.87) L1 L2 L3 ++ 5 8 1 4 3
SPD Switching Power Sulies CARLO GAVAZZI resents a new range of ower sulies esecially designed for the automation market. The wide range of suly voltages and DC outut voltages/ower rovide a multitude of choices for all low ower electrical or electronic devices commonly used in automatic machinery. Comonents such as sensors, electromechanical relays, contactors, solid state relays, timers, temerature controllers, PLCs, rocess controllers, DC motors, solenoids, dislays, etc. now have a reliable ower source. Sace Otimization User Friendly Diagnostic Warning Minimizing Energy Cost Long Term Reliability Long Term Reliability High Efficiency The ower suly s average efficiency and rile voltage ratings are comarable or better than most ower sulies on the market. Product Range The roduct range 5V 12Vfeatures 15V 24V several different outut ower rat- 48V SPD 5-10-18W ings, from 5 to 480W. All models feature SPD 30-60W a universal 100 / 240Vac inut. The existing roduct offering SPD 120W is single hase, but three hase versions are currently in SPD 240-480W develoment. Adjustable Outut All models rovide a front otentiometer in order to adjust the outut voltage. This useful feature can rovide a voltage surlus when line voltage losses cause low voltages to the load. Parallel Connection Parallel connection is a standard feature with the 240W and 480W versions, and otional on the 120W version. Visual and Electrical Indications Models u to 18W are equied with two front LEDs, which rovide a visual indication of the Power Out enabled and Low Voltage on the outut. All other sizes are equied with an LED indication and also with an outut 'Power Ready' signal. This signal could be used by other electronic devices or to ower an alarm (this feature is only available on 24VDC outut versions). Secifi cations are subject to change without notice. Power Factor Correction (PFC) The PFC function is a standard feature on the 240W and 480W models and available uon request on the 120W model. Arovals and Warranty All SPD Power Sulies are aroved according to UL, cul, TUV and CE safety standards: UL class 2 recognized and Class B for the emissions according to Euroean standards. They are also RoHS comliant. All models feature a Two Year Warranty.
PARALLEL or SINGLE FUNCTION SWITCH On the 240W and 480W versions the arallel/single function switch is a standard feature, on the 120W version it is available as an otion. By setting this switch on the 'Parallel' osition it is ossible to connect u to three ower sulies in arallel, in order to increase outut ower. Also on the 'Parallel' osition, voltage outut is fixed and not adjustable in order to revent unbalanced outut voltages. Outut '+' and '-' terminals are doubled, on models from 120W, in order to easily facilitate arallel connection. Ventilation Grid Model Number Inut Terminals Also available with removable terminals PFC function: built in. Safety Label Aroval data file numbers EAN cod and traceability data. DIN Rail Cli Easy installation on any kind of DIN Rail. 'ON' LED Indicates ower outut is OK. 'LO' LED Indicates outut voltage too low. Vout Adjustment Allows voltage outut voltage adjustment within a small range to the required value. Outut Terminals Also available with removable terminals Outut Ready Terminals Useful feature roviding an electrical indication of good oeration. SPD 480W 480W switching ower suly Metal housing Screw terminals or detachable connectors Inut voltage: 90-264VAC or 120-370VDC (115/230 autoselected) Outut voltage adjustment PFC function standard Parallel function standard (selectable by front switch) Short circuit, overload and overvoltage rotection Relay outut for ower Ready signal (voltage free terminals) Oerating temerature without derating: 10 to +60 C Secifi cations are subject to change without notice.