Technical Information Condumax CLS21D/CLS21

Similar documents
Technical Information Condumax CLS15D/CLS15

Condumax CLS21 and CLS21D

Condumax CLS21 and CLS21D

Condumax CLS15 and CLS15D

Condumax CLS15 and CLS15D

Condumax W CLS15 and CLS15D

Technical Information Memosens CLS82D

Condumax W CLS15 and CLS15D

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Technical Information Indumax CLS50D/CLS50

Condumax CLS16 and CLS16D

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Technical Information Orbipac CPF81D/CPF82D and CPF81/CPF82

Indumax CLS50/CLS50D. Technical Information

Orbipac CPF81/CPF82 and CPF81D/CPF82D

Technical Information Orbipore CPS91D and CPS91

Conductivity Measuring Cells for High-Temperature Applications ConduMax H CLS 16

Conductivity Sensor for High-Temperature Applications ConduMax W CLS 13

Memosens CPS96D. Technical Information

Technical Information Memosens CPS96D

Technical Information Indumax CLS54

Technical Information Smartec CLD18

Technical Information Smartec CLD18

Indumax CLS54D. Technical Information

Ceramax CPS341D. Technical Information

Technical Information Smartec CLD18

Memosens New technology for contactless, inductive, digital transmission of ph signals

Conductive conductivity measurement mypro CLM 431 / CLD 431 conductive

Technical Information Memosens CCS50D

Liquisys M CLM223/253

Inductive conductivity measurement mypro CLM 431 / CLD 431 inductive

Turbimax CUS71D. Technical Information. Ultrasonic interface sensor Immersion sensor for interface measurement

Indumax H CLS54. Technical Information

Submersible pressure sensor For superior applications Model LF-1

Submersible pressure sensor For oils and fuels Model LF-1

Technical Information Liquisys M CLM223/253

Submersible pressure sensor For water and wastewater Model LW-1

OEM radar transmitter, for aggressive media level measurement

Digital conductivity transmitter

JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor

The transducer component converts the measured signal and displays the actual value.

Conductivity sensor for hygienic applications

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

Flow Measurement SITRANS F M

OPTIFLUX 5000 Technical Datasheet

SMARTPAT COND 1200 Technical Datasheet

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

OPTIFLUX 5000 Technical Datasheet

Tophit CPS441 and CPS441D

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

Content. Flow meter F2-UN. Description Technical Data Dimension drawings Operation... 8 Mounting instructions...

Conductivity Transmitter

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Temposonics. Magnetostrictive Linear Position Sensors. ET Analog Data Sheet

Tophit CPS491 and CPS491D

Technical Data. General specifications. Rated operating distance s n 3 mm

BlackLine Lf-GT / -EC electrolytic 2-electrode conductivity cells

Assembly 249 (9.80) 259 (10.2) Example: level probe with Pt100 and HUT temperature head transmitter ( ma) ma. Core colors: RD BK YE BU

OPTIFLUX 1000 Technical Datasheet

Resistance thermometer Model TR30, compact design

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Liquisys M COM223/253

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

0 2 1 â Ó. itemp HART TMT182. Technical Information

Measuring and Controlling Unit Multronic OC

Smartec S CLD134. Technical Information

Conductivity measurement SmarTec S CLD 132

Turbidity sensor TurbiMax W CUS 41

Float Switches with Permanent Magnet For Vertical Installation Model RSM

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

High-quality pressure transmitter For general industrial applications Model S-10

Conductivity measurement Mycom S CLM 153

LF Conductivity Measuring Probe

ED701 General Industry Pressure Transmitter

Ultrasonic level measuring device, non-contact

Technical Information Nivector FTC968, FTC968Z

Coriolis Massflowmeter

VITO LT. Global Experience. Locally Applied. A dependable choice.

Tophit CPS491 and CPS491D

SITRANS F M MAGFLO Electromagnetic Flowmeters Explore the Siemens Solution. sitrans f

prosonic T FMU230, FMU231

Positioner with HART Communication Type 3780

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

B Operating Instructions V1.00/EN/

Coriolis Massflowmeter

Rosemount 3101, 3102, and 3105

Process display RIA 261

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

Resistance thermometer Model TR30, compact design

TIDALFLUX 2300 F Technical Datasheet

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Liquisys M CPM223/253

Temposonics. Magnetostrictive Linear Position Sensors. GB-M / GB-T SSI Data Sheet

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview

ph / ORP Measurement mypro CPM 431

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

Ultra high purity transducer, Ex na nl Models WU-20, WU-25 and WU-26

Level Measurement Continuous level measurement Radar transmitters

Transcription:

TI00085C/07/EN/14.14 71268310 Products Solutions Services Technical Information Condumax CLS21D/CLS21 Conductivity sensors, analog or digital with Memosens technology Cell constant k = 1.0 cm 1 Application Measurement in media with average or high conductivity: Separation of media with average conductivity (milk/water) Separation of media with high conductivity (alkali/water) Drinking water treatment Wastewater treatment Sensors with temperature probes are used in conjunction with conductivity measuring devices that support automatic temperature compensation: Liquiline CM442/CM444/CM448 (only CLS21D) Liquiline CM42 Liquiline CM14 (only CLS21D) Liquisys CLM223/253 (only CLS21) Mycom CLM153 (only CLS21) The resistivity in MΩ cm can also be measured using these transmitters. Your benefits Different designs for optimum adaptation to the process or installation location Installation in pipe or flow assembly Compact design With plug-in head (IP68 (CLS21D), IP65 (CLS21)) or fixed cable (IP67) High chemical, thermal and mechanical resistance Quality certificate stating the individual cell constant Other advantages of Memosens technology Maximum process safety owing to non-contact, inductive signal transmission Data security thanks to digital data transmission Very easy to use as sensor data saved in the sensor Predictive maintenance possible as sensor load data logged in the sensor

Function and system design Measuring principle AC U I Conductivity of liquids is determined with a measuring arrangement where two electrodes are located in the medium. An alternating voltage that causes a current to flow through the medium is applied at these electrodes. The electrical resistance, or its reciprocal value - conductance G - is calculated based on Ohm's law. The specific conductance κ is determined from the conductance value using the cell constant k, which depends on the sensor geometry. A0024260 1 Conductive measurement of conductivity AC Alternating voltage source I Current intensity measurement U Voltage measurement Measuring system A complete measuring system comprises the following components at least: The conductively measuring conductivity sensor CLS21D or CLS21 A transmitter, e.g. Liquiline M CM42 A measuring cable, e.g. Memosens data cable CYK10 or CYK71 for analog sensors 1 3 2 2 Example of a measuring system (with Memosens sensor) 1 Liquiline M CM42 transmitter 2 Memosens data cable 3 Condumax CLS21D A0024376 2 Endress+Hauser

Communication and data processing (only CLS21D) Communication with the transmitter Always connect digital sensors with Memosens technology to a transmitter with Memosens technology. Data transmission to a transmitter for analog sensors is not possible. Digital sensors are able to store the following system data in the sensor Manufacturing data Serial number Order code Date of manufacture Calibration data Calibration date Cell constant Delta cell constant Number of calibrations Serial number of the transmitter used for the last calibration Application data Temperature application range Conductivity application range Date of first commissioning Maximum temperature value Hours of operation at high temperatures Dependability (only CLS21D) Reliability Maintainability Integrity Memosens technology digitizes the measured values in the sensor and transmits the data to the transmitter using a non-contact connection that is free from potential interference. The result: Automatic error message if sensor fails or connection between sensor and transmitter is interrupted Immediate error detection increases measuring point availability Easy handling Sensors with Memosens technology have integrated electronics that allow for saving calibration data and further information such as total hours of operation and operating hours under extreme measuring conditions. Once the sensor has been connected, the sensor data are transferred automatically to the transmitter and used to calculate the current measured value. As the calibration data are stored in the sensor, the sensor can be calibrated and adjusted independently of the measuring point. The result: Easy calibration in the measuring lab under optimum external conditions increases the quality of the calibration. Pre-calibrated sensors can be replaced quickly and easily, resulting in a dramatic increase in the availability of the measuring point. Maintenance intervals can be defined based on all stored sensor load and calibration data and predictive maintenance is possible. The sensor history can be documented on external data carriers and evaluation programs at any time. Thus, the current application of the sensors can be made to depend on their previous history. With inductive transmission of the measured value using a non-contact connection, Memosens guarantees maximum process safety and offers the following benefits: All problems caused by moisture are eliminated. Plug-in connection free from corrosion Measured value distortion from moisture is not possible. The plug-in system can even be connected under water. The transmitter is galvanically decoupled from the medium. EMC safety is guaranteed by screening measures for the digital transmission of measured values. Endress+Hauser 3

GN/YE GN/YE } Condumax CLS21D/CLS21 Input Measured variables Conductivity Temperature Measuring ranges Conductivity (in relation to water at 25 C (77 F)) CLS21D/CLS21 Temperature CLS21D CLS21 10 μs/cm to 20 ms/cm -20 to 100 C (-4 to 212 F) -20 to 135 C (-4 to 275 F) Cell constant CLS21D/CLS21 k = 1.0 cm 1, nominal Temperature compensation NTC 30K (CLS21D) Pt 100 (class A as per IEC 60751) (CLS21) Power supply Electrical connection CLS21D The sensor is electrically connected to the transmitter via the CYK10 measuring cable. GY GND YE Com B GN WH BN Com A + 3 Measuring cable CYK10 A0024019 CLS21 The sensor is connected via the fixed cable or via the CYK71 measuring cable with a shield. The wiring diagram is provided in the Operating Instructions of the transmitter used. Cable GY Coax BK Coax inner Sensor Plug ) shield (outer electrode) 2 conductivity (inner electrode) Outer shield (see wiring diagram of transmitter) GN WH YE BN n.c. } 3 1 Pt 100 4 Measuring cable CYK71 A0024205-EN A compatible cable connector is included in the delivery for the plug-in head versions. You must terminate the CYK71 cable (not included in the delivery) with the cable connector at the sensor end according to the connection diagram above. A VMB junction box and another CYK71 cable are required for the cable extension. 4 Endress+Hauser

Performance characteristics, general Uncertainty of measurement Each individual sensor is factory-measured in a solution of approx. 5 ms/cm (CLS21D) or approx. 500 µs/cm (CLS21) using a reference measuring system traceable to NIST or PTB. The exact cell constant is entered into the quality certificate supplied. The uncertainty of measurement in determining the cell constant is 1.0 %. Performance characteristics (only CLS21D) Response time Conductivity t 95 3 s Temperature t 90 296 s Maximum measured error 5% of reading Repeatability 0.2% of reading Endress+Hauser 5

Installation Installation instructions The sensors are installed directly via the process connection. As an option, the sensor can also be installed via a flow assembly (see "Accessories"). A0019019 A0019020 5 Installation in flow assembly CLA751 7 Installation in flow assembly CLA752 A0024201 A0024202 6 Installation in flow assembly CLA751 8 Installation in flow assembly CLA752 6 Endress+Hauser

The Dipfit CLA111 immersion assembly is available to install sensors with a G1 thread in vessels (see list of accessories). A B D A0024145 9 Installation in Dipfit CLA111 immersion assembly, fastening versions A, B and D Environment Ambient temperature range -20 to +60 C (0 to 140 F) Storage temperature -25 to +80 C (-10 to +180 F) Humidity 5 to 95 % Degree of protection CLS21D IP 68 / NEMA type 6P (1 m water column, 25 C, 24 h) CLS21 Fixed cable version IP 67 / NEMA 6 Plug-in head version IP 65 / NEMA 4X Endress+Hauser 7

Process Process temperature Threaded version with fixed cable -20 to 100 C (-4 to 212 F) Version with plug-in head, Clamp version-20 to +135 C (-4 to 275 F) at 2.5 bar (36 psi) The maximum temperature for communication with the transmitter is 130 C (266 F) for the Memosens versions. Process pressure (absolute) CLS21D/CLS21 17 bar (246 psi) at 20 C (68 F) Temperature-pressure ratings [psi] 246 188 130 [bar] 17 13 9 p (abs.) 72 51 14 5 3.5 1-20 20 135 0 30 60 90 120 [ C] T -4 20 68 275 60 100 140 180 220 [ F] 10 Mechanical pressure-temperature resistance A0024886 Mechanical construction Design CLS21D 1 4 2 3 11 CLS21D 1 Memosens plug-in head 2 Process connection (here G1) 3 Coaxial measuring electrodes made of graphite 4 Wrench flats for mounting A0024381 8 Endress+Hauser

Design CLS21 1 2 1 4 3 2 3 12 Design with plug-in head 1 Four-pin connector 2 Cable gland Pg 9 3 Process connection (here Clamp 2") 4 Sensor shaft with measuring electrodes A0024380 13 Design with fixed cable 1 fixed cable 2 Process connection (here NPT 1" thread) 3 Sensor shaft with measuring electrodes A0024379 Dimensions CLS21D 186 (7.32) 79 (3.11) 18 (0.71) 16 (0.63) Ø 44 (1.73) G 1 186 (7.32) 61 (2.40) 15 (0.59) 16 (0.63) Ø 44 (1.73) Ø 64 (2.52) A0024382 A0024390 14 Version with thread G1 15 Version with Clamp 2" Endress+Hauser 9

186 (7.32) Ø 44 (1.73) NPT 1" AF 35 NPT 1" 14 (0.55) 189 (7.44) 61 (2.40) 10 (0.39) 16 (0.63) DN 25 16 (0.63) 61 (2.40) 87 (3.43) A0024393 A0024394 16 Version with sanitary connection Measurements in mm (inch) 17 Version with thread NPT 1" Dimensions CLS21 NPT 1" AF 35 NPT 1" 16 (0.63) 61 (2.40) 14 (0.55) 113 (4.45) 157 (6.18) 144 (5.67) 113 (4.45) 15 (0.59) 61 (2.40) 16 (0.63) Ø 34 (1.34) Ø 64 (2.52) A0024397 A0024398 18 Fixed cable version with NPT 1" thread 19 Fixed cable version with Clamp 2" 10 Endress+Hauser

151 (5.94) 79 (3.11) 36 (1.42) 21 (0.83) 36 (1.42) 18 (0.71) Ø 44 (1.73) G 1 151 (5.94) 16 (0.63) 61 (2.40) 54 (2.13) 36 (1.42) 15 (0.59) Ø 34 (1.34) Ø 64 (2.52) 16 (0.63) A0024401 A0024402 20 Plug-in head version with G1 thread 21 Plug-in head version with Clamp 2" 151 (5.94) 61 (2.40) 54 (2.13) 36 (1.42) 10 (0.39) Ø 34 (1.34) DN 25/DN 40 16 (0.63) A0024403 22 Plug-in head version with sanitary connection Measurements in mm (inch) Weight Approx. 0.3 kg (0.66 lbs) depending on version Materials (in contact with medium) Electrodes Sensor shaft Thermal conductivity socket for temperature probe Graphite Polyethersulfone (PES-GF20) Titanium 3.7035 Process connections Thread G1 NPT 1" thread Clamp 2" as per ISO 2852 Sanitary connection DN 25 as per DIN 11851 Endress+Hauser 11

Certificates and approvals mark Declaration of Conformity The product meets the requirements of the harmonized European standards. As such, it complies with the legal specifications of the EC directives. The manufacturer confirms successful testing of the product by affixing to it the mark. Ex approvals CLS21D-**G ATEX / NEPSI II 1G Ex ia IIC T3/T4/T6 Ga, IECEx Ex ia IIC T3/T4/T6 Ga CLS21D-**O FM/CSA IS/NI Cl. I Div.1&2 Gr. A-D in conjunction with Liquiline M CM42 transmitter CLS21D-**V ATEX/NEPSI II 3G Ex ic IIC T3/T4/T6 Gc for use in Zone 2 with Liquiline M CM42-KV*** transmitter CLS21 ATEX II 1G EEx ia IIC T3/T4/T6 FM/CSA IS/NI Cl. I Div.1&2 Gr. A-D in conjunction with Liquiline M CM42 transmitter ATEX and FM/CSA versions of digital sensors with Memosens technology are indicated by a red-orange ring in the plug-in head. Quality certificate Stating the individual cell constant Ordering information Product page www.endress.com/cls21d www.endress.com/cls21 Product Configurator The navigation area is located on the right of the product page. 1. Under "Device support" click "Configure your selected product". The Configurator opens in a separate window. 2. Select all the options to configure the device in line with your requirements. In this way, you receive a valid and complete order code for the device. 3. Export the order code as a PDF or Excel file. To do so, click the appropriate button at the top of the screen. Scope of delivery The scope of delivery includes: Sensor in the version ordered Cable connector, for connecting to CYK71 measuring cable (only for plug-in head versions CLS21) Operating Instructions 12 Endress+Hauser

Accessories The following are the most important accessories available at the time this documentation was issued. For accessories not listed here, please contact your service or sales office. Assemblies Dipfit CLA111 Immersion assembly for open and closed vessels with flange DN 100 Product Configurator on the product page: www.products.endress.com/cla111 Technical Information TI00135C Flow assembly CLA751 For installing conductivity sensors with G1 thread (CLS12, CLS13, CLS21, CLS30) Inlet (below) and outlet (lateral) DN 20 with G1 thread adapter nut Stainless steel 1.4571 (AISI 316Ti) Max. temperature 160 C (320 F), max. pressure 12 bar (174 psi) Order No. 50004201 Ø 50 (1.97) G 1 160 (6.30) Ø 20 (0.79) 120 (4.72) G 1 G 1 23 Dimensions in mm (inch) A0024377 Flow assembly CLA752 For installing conductivity sensors with G1 thread (CLS12, CLS13, CLS21, CLS30) Inlet (lateral) and outlet (lateral) DN 20 with G½ internal thread Polypropylene (PP) Max. temperature 90 C (194 F), max. pressure 6 bar (87 psi) Order No. 50033772 G 1 160 (6.30) G ½ G ½ Ø 80 (3.15) 24 Dimensions in mm (inch) A0024378 Endress+Hauser 13

Measuring cable CYK10 Memosens data cable For digital sensors with Memosens technology Product Configurator on the product page: www.endress.com/cyk10 Technical Information TI00118C Memosens data cable CYK11 Extension cable for digital sensors with Memosens protocol Product Configurator on the product page: www.endress.com/cyk11 Technical Information TI00118C Measuring cable CYK71 Unterminated cable for connecting analog sensors and for extending sensor cables Sold by the meter, order numbers: Non-Ex version, black: 50085333 Ex-version, blue: 50085673 Junction boxes (only CLS21) Calibration solutions VBM Junction box for cable extension 10 terminal strips Cable entries: 2 x Pg 13.5 or 2 x NPT ½" Material: aluminum Degree of protection: IP 65 Order numbers Cable entries Pg 13.5 : 50003987 Cable entries NPT ½": 51500177 VBM-Ex Junction box for cable extension in hazardous area 10 terminal strips (blue) Cable entries: 2 x Pg 13.5 Material: aluminum Degree of protection: IP 65 ( NEMA 4X) Order number: 50003991 Conductivity calibration solutions CLY11 Precision solutions referenced to SRM (Standard Reference Material) by NIST for qualified calibration of conductivity measuring systems in accordance with ISO 9000 CLY11-A, 74 μs/cm (reference temperature 25 C (77 F)), 500 ml (16.9 fl.oz) Order No. 50081902 CLY11-B, 149.6 μs/cm (reference temperature 25 C (77 F)), 500 ml (16.9 fl.oz) Order No. 50081903 CLY11-C, 1.406 ms/cm (reference temperature 25 C (77 F)), 500 ml (16.9 fl.oz) Order No. 50081904 CLY11-D, 12.64 ms/cm (reference temperature 25 C (77 F)), 500 ml (16.9 fl.oz) Order No. 50081905 Technical Information TI00162C 14 Endress+Hauser

www.addresses.endress.com