Wireless Switches & Sensors... New Control Possibilities

Similar documents
Energy harvesting wireless offers an easy, inexpensive alternative for adding energy management features to older automation systems.

Optimize Outage Management and Improve Underground System Reliability

Limitless Wireless Multi-Protocol Receiver. WMPR Series. Datasheet


Submersible pressure sensor For water and wastewater Model LW-1

Remote Radio Control. WAVE Push button radio control systems

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control

WOI Series. Limitless Wireless Operator Interface DESCRIPTION

KENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents

Submersible pressure sensor For oils and fuels Model LF-1

Dräger X-zone 5500 with Advanced 3D Communications

Photonic Power. Application Overview

Accutech AM20. Wireless acoustic monitor field unit

WAGO Application: Plastic Technology Center (SKZ) in Würzburg, Germany

Self-powered RadioTechnology for Building Automation Systems

Rudder or propeller angular position transmitter KINAX WT720

2011 / Circuit Tracer

How to Select the Right Positioning Sensor Solution A WHITE PAPER

Level Measurement Techniques In A Modern Quarry

COOLANT WASTE MINIMIZATION USING A COALESCING PLATE SEPARATOR

Mx-RPW Room Control Module (Built-In Occupancy Sensor)

Submersible pressure sensor For superior applications Model LF-1

SECTION 20. ELECTRICAL AND ELECTRONIC SYMBOLS

FOR RELIABLY MEASURING +

Installation guide 873 SmartRadar Control Unit & Antenna Unit

Control solutions Biofloor

XYR 5000 Wireless Transmitters SIMPLE. SAFE. SECURE. Honeywell Solutions for Wireless Data Acquisiton and Monitoring

Limitless Wireless Multi-Protocol Receiver WMPR Series Issue 2. Datasheet FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS

GS Strain gauge reader/ transmitter. GS series of wireless industrial sensors. Features: General Description: Applications:

Accutech DP20. Wireless differential pressure field unit

Accutech AI10 & AV10. Wireless multi-input field unit

SubArc Digital Series

Field Devices and Wiring

EC 21 EC RMG Meßtechnik GmbH. Gas Volume Corrector. via Temperature. Volume Correction. via Pressure and Temperature

Signal Beacon - LED Series 6162

Smart Displacer Level (Interface) Transmitter DLT100 Series

Accutech TC10. Wireless thermocouple temperature field unit

Page Type Resolution (mm) min. max. Output

Wireless & self-powered Internet of Things

Energy Savings Material Savings Minimize Costs Ideal Uses

RAD-IN/OUT-8D. Digital extension modules for the bidirectional wireless system. INTERFACE Data sheet _en_05. 1 Description

Telemetry System. Semester 3rd. Chapter-1 Telemetry Principles. Prof Z D Mehta Instrumentation and control Department Government Polytechnic Ahmedabad

Level Lance Model 5100

SAPLING WIRELESS SYSTEM

Digital GPS Repeaters for Wireless Network Timing

SubArc Digital Series

Remote Monitoring of Environmental Sites using Solar Powered Wi-Fi Enabled Systems

The Rosemount 848T Wireless Temperature Transmitter

Motor Vibration. Detect Mechanical & Electrical Motor Faults with Vibration Monitoring Instrumentation. IMI Sensors - A PCB Piezotronics Division

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

Flow Technologies Overview. For internal use only / Siemens AG All Rights Reserved.

Sensor Portfolio for Machinery Health Applications

COMMERCIAL TRANSMITTER INSTRUCTIONS

Accutech GP10. Wireless gauge pressure field unit

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

Battery-Free Wireless Pushbutton Useful Tips for Reliable Range Planning

IT6810/IT6811/IT6812 IMPACT TRANSMITTER Installation Manual

Cyclops User s Manual

INSTALLATION AND OPERATION MANUAL

White Paper: Zero Power Wireless Sensors

Gas Well Deliquification Workshop. David J Southern, P. Eng. Control Microsystems, Inc. Gas Well Deliquification Workshop

ISA Series. resistance welding. Mid-Frequency Inverter Resistance Welding Control

Hazardous environments

DOW IMPROVES INSTRUMENT RELIABILITY 66% AND SAVES MILLIONS OF DOLLARS WITH REAL-TIME HART TECHNOLOGY

SET Installation and Operating Instructions. Level switch for two sensors

Wireless Base Radio. Wireless Transmitters

ENAiKOON inmarsat-600

ENERGY HARVESTING 2016 REAL BATTERY LESS & WIRELESS SWITCHING TECHNOLOGY FOR THE FUTURE

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits

SONAPHONE-Family PRODUCT OVERVIEW PREVENTIVE MAINTENANCE LEAK DETECTION AND CLASSIFICATION

Balanced Constant Current Excitation for RTD Sensor Measurements

MRT. Instruction Manual. Remote Crane Controls. PSMRTINST-01A October, 2001 Part Number: Copyright 2001 Electromotive Systems

1: Introduction : Caution : Tips for Reading this Manual : Preface : System Highlights : Receiver

Plate Cartridge Compact Flexible Automatic Feed System

Wireless Ceiling Motion Sensor for Occupancy / Vacancy Detection with integrated diagnostic tools INSTALLATION GUIDE

Accutech RT10. Wireless RTD temperature field unit

Appendix 6 Wireless Interfaces

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Installation guide 971 SmartRadar LTi

ABB MEASUREMENT & ANALYTICS. LLT100, LM80 and LM200 Lasers for level now everything is possible

PAGE/PARTY. Solutions. GAI-Tronics Page/Party. communication systems. provide paging and. party-line capabilities... two important plant

P700-WLS ioprox Receiver

theben Fan Coil Actuator FCA 1 Fan Coil Actuator FCA 1 FCA Version: Jan-08 (Subject to change) Page 1 of 77

Dust removal filters for combustible dusts Information

nvision Reference Recorder

Fan Coil Actuator FCA 2

Radio Remote Controls Protean TM L Series K Series

Safety and alarming applications using ISA100 Wireless

Ness MCR Multi-Channel Radio Receiver

Think About Control Fundamentals Training. Terminology Control. Eko Harsono Control Fundamental

BEST CONNECTIONS IN EVERY ENVIRONMENT

R PROFLAME Instruction Book Collection

HILMA Quick Tool Change for Forging Applications

Electrical Controls. Isaac Queen

VisorTrac A Tracking System for Mining

CareMat A DATASHEET. The pressure-sensitive mat for supervision of people with dementia and disorientation. RoHS. Product Description

D.C. Hydraulic Power Systems

Model Sono-Trak Transit Time

Sistema de Seguridad y Control Personal

LF Conductivity Measuring Probe

Transcription:

Wireless Switches & Sensors... New Control Possibilities INTRODUCTION By STEUTE USA Clearly, wireless technology has been widely accepted and embraced in the industrial community. New and evolving Standards, the availability of a wide range of devices, and the demonstrated performance of a large, installed base each serve as testimony to their efficacy. However, while there is a large selection of devices for monitoring, transmitting, receiving and processing continuously variable parameters (such as flow, temperature, pressure et al), there has been little available in the way of wireless devices for generating and receiving simple "on-off" signals for machine start/stop control, presence/position sensing, counting, alarm signaling, process control, and other desired digital inputs. This is now changing with the development and introduction of a number of robust, reliable digital contact and non-contact switches, sensors and related accessories. Available and emerging control components include: Mechanical limit switches Contact-type presence sensing switches Non-contact magnetic sensors Non-contact inductive sensors Photo-optical sensors Pull-wire switches Pushbutton switches Momentary and maintained selector switches Key-operated switches Foot switches Door handle systems with integral push button control functions. Typical examples of such products can be seen in the images below. (Page 1 of 12)

Wireless Magnetic, Limit and Inductive Switches (Photo Courtesy of Steute Wireless) Wireless Photo-Optical Non-Contact Sensor (Photo Courtesy of Banner Engineering) (Page 2 of 12)

Wireless Pushbutton Station (Photo Courtesy of Schneider Electric) Door Handle Assembly with Integrated Wireless Pushbutton Control Switch (Photo courtesy of Steute Wireless) (Page 3 of 12)

Wireless Pull-Wire Switch (Photo courtesy of Steute Wireless) TECHNOLOGY ADVANCES The realization of these new wireless digital control inputs has been the result of a number of notable technical developments. Among these are: The design and production of robust, energy harvesting mechanisms (energy generators) capable of meeting the duty cycle and life expectancy requirements typically encountered in industrial applications. One effective technique is shown in the illustration below. Here a permanent magnet is moved through an electrical coil by the motion of the switch actuator. This creates sufficient electrical energy to transmit an encrypted, wireless telegram to a paired receiver within the signal s range. These generators, designed with mechanical life expectancies in excess of 1 million operations, eliminate the need for a battery power source in a variety of mechanically-actuated switches (e.g. limit, pull-wire, pushbutton, selector, keyoperated, and foot switches). (Page 4 of 12)

Limit Switch with Energy Generator The design of transmitter electronics that require little power and permit bidirectional communications between transmitters and receivers. Transmission protocols feature short telegrams for minimal transmission-time durations. Frequency 868 MHz 915 MHz 2.4 GHz # of Channels 1 1 32 Data Rate 66 kbit/s 66 kbit/s 250 kbit/s Telegram Length 4 to 7 bytes 4 to 7 bytes 16 bytes The use of solar energy or high energy-density, long-life batteries (where mechanical energy generators are not feasible). Magnetic Switch with Battery Power Source (Page 5 of 12)

The application and use of noise-immune wireless frequencies (e.g. 868 MHz, 915 MHz, and 2.4 GHz) that are Nationally- or Globally-accepted Standards in industrial control applications. Frequency Accepted Norm in: 868 MHz Europe 915 MHz North America 2.4 GHz Worldwide The design of field strength monitors that facilitate effective installation, and maintenance of the communication links. Hand-Held Signal Field Strength Monitors Facilitate Optimal System Installation POTENTIAL BENEFITS Among the potential benefits these control solutions offer are: Lower installation costs here the elimination of materials (cable, connectors, conduit, cable tray, junction boxes, strain reliefs, et al) and their associated installation labor can result in significant savings. Such economies can be even more significant for switches and sensors that are located relatively far from their termination point, or which require armored, shielded or other premium-priced cabling. (Page 6 of 12)

Reduced maintenance costs the elimination of cabling also reduces the potential for cable damage and related repair or maintenance costs. Increased system uptime as maintenance requirements are reduced, system uptime and productivity can be increased. Flexible control system topology the availability of wireless switches and sensors enables the control system designer to place digital inputs in remote and hard-to-access-with-cable locations. In addition, switches can be easily added to an existing machine or work cell. New potential solutions for selected EX applications the inherent low power operating characteristics permit use of ATEX-IECEx-certified wireless switches/sensors in selected explosionhazardous areas without need for intrinsically-safe barriers, encapsulation or other costly protection method. (Page 7 of 12)

New potential solutions for applications where wiring or wiring-maintenance is deemed impractical or not economically-feasible examples are: Remote locations where distributed electrical power is not readily available. Rotary equipment where flexible cables wear or suffer damage. Rotary equipment requiring slip rings. Locations where cable runs are extremely long or the installation cost is considered excessive. Reduced personnel costs use of wireless switches may allow reduction in personnel costs in applications in which digital information is now collected locally by human messenger. Examples are local in-situ production counts and assembly station stock status. TYPICAL & POTENTIAL APPLICATIONS Since these devices are relatively new, many potential applications have yet to be identified and realized. Among the applications already experiencing one or more of these benefits are: Valve position monitoring Remote crane control Remote point presence or position sensing Assembly station inventory management systems Fire vent position monitoring Tank level monitoring Hatch and access port monitoring Hopper flap/diverter monitoring Safety shower/eyewash station alarm monitoring Rotary machinery Automatic door control Door monitoring Explosive environments (Page 8 of 12)

Application: Automotive Assembly Line Inventory Management System In this application, assembly line workers at this location require several different components to complete each assembly. In the past, they would place a stock requirement card in a pick-up location as additional parts were required. Periodically a messenger would retrieve these cards and take them to the stock room at which point replenishments would be dispatched to the assembly cell. The messenger has been eliminated by using placing wireless limit switches underneath the second bin position on each track containing multiple bins of one of the assembly components. As the leading bin on each track empties, it is physically removed to allow the next bin in the track to slide into the first bin position. When the last bin of parts in each track slides into the first position, the second position in the track becomes vacant. The absence of a bin in the feed track changes the state of the wireless limit switch, sending an encrypted signal to the central stock location. This signal alerts the stock room of an emerging need for additional quantities of the specific part associated with received signal. Required parts are then dispatched to the assembly cell. Benefits realized included: Low installation costs. Personnel cost savings elimination of the Messenger. Faster stock replenishment. Reduced assembly cell downtime. Increased productivity. (Page 9 of 12)

Application: Valve Position Monitoring Here, it was desired that the open and closed positions of the manually-operated valves be detected and respective control signals sent to the control center in a natural gas pumping station. To achieve this, two wireless electromechanical limit switches were fixed to the valve head. Each was actuated by a flag/cam mounted to the valve head. By design, these ATEX-IECEx rated position switches operate at an extremely low voltage and current level well below any power level capable of producing a spark. Each transmits a safe signal to wireless receiver mounted outside the explosion-risk area. Benefits realized included: Greatly reduced maintenance with no batteries or cables to replace. Lower installation costs no cables to run and protect from the switches to the control cabinet. Lower component costs due to the elimination of expensive Ex-rated cables and connectors. Radioed signals allowed the control cabinets to be located outside the explosion-risk area. Safe operation in Zone 1 and Zone 2 explosion-risk areas. (Page 10 of 12)

Application: Tank Truck Filler Pipe Position Monitoring Similar wireless switches proved of value in a refinery s tank truck filling facility. Here the goal was to assure that the neck of the fuel filling pipe was properly positioned above the opening in the tank truck being loaded before beginning the filling operation. (Page 11 of 12)

Originally, filling pipe position was monitored using conventional cabled limit switches. While this solution was functional, the electrical cables from the switches to the control panel quickly wore or were damaged by the frequent movement and/or from chafing by the fuel pipe. Replacing the cabled switches with wireless functional-equivalents eliminated the problem resulting in a reliable, robust, long-term solution. Benefits realized included: Greatly reduced maintenance with no batteries or cables to replace. Low installation costs no cables to run and protect from the switches to the control cabinet. Safe operation in an explosion-risk area. # # # # (Page 12 of 12)