IMD and RF Power Measurements with the Keysight PNA-X N5249A

Similar documents
Keysight Technologies Making Accurate Intermodulation Distortion Measurements with the PNA-X Network Analyzer, 10 MHz to 26.5 GHz

Keysight Technologies Amplifier and CW Swept Intermodulation - Distortion Measurements using the PNA Microwave Network Analyzers.

PXIe Contents CALIBRATION PROCEDURE

IMD Measurement Wizard for the E5072A ENA Series Network Analyzer Operation Manual. Agilent Technologies June 2012

Keysight Technologies PNA-X Series Microwave Network Analyzers

Keysight M9485A PXIe Multiport Vector Network Analyzer

Introduction. Part 1. Introduction...2

Configuration of PNA-X, NVNA and X parameters

External Source Control

Introduction. Part 1. Introduction...2

SRT optical links prototypes characterization

VVM measurement with E5061B for replacing 8508A vector voltmeter. May 2013 Agilent Technologies

Quick Site Testing with the 8800SX

Keysight 2-Port and 4-Port PNA-X Network Analyzer

Basic Transceiver tests with the 8800S

A True Differential Millimeter Wave System with Port Power Control. Presented by: Suren Singh

PNA Family Microwave Network Analyzers (N522x/3x/4xB) CONFIGURATION GUIDE

IVCAD VNA Base Load Pull with Active/Hybrid Tuning. Getting Started v3.5

HP Archive. This vintage Hewlett Packard document was preserved and distributed by www. hparchive.com Please visit us on the web!

Platform Migration 8510 to PNA. Graham Payne Application Engineer Agilent Technologies

Keysight Technologies Accurate Mixer Measurements Using the ENA RF Networks Analyzers Frequency-Offset Mode. Application Note

Banded Milimeter Wave Network Analysis TECHNICAL OVERVIEW

Advanced Test Equipment Rentals ATEC (2832)

Agilent CSA Spectrum Analyzer

Agilent PNA Microwave Network Analyzers

Migrating 4195A to E5061B LF-RF Network Analyzer. April 2010 Agilent Technologies

RF and Microwave Test and Design Roadshow 5 Locations across Australia and New Zealand

Keysight MOI for MIPI D-PHY Conformance Tests Revision Oct, 2014

Keysight Technologies Ampliier Linear and Gain Compression Measurements with the PNA Microwave Network Analyzers. Application Note

PXA Configuration. Frequency range

Measurement of the equivalent circuit of quartz crystals

Equivalent Circuit Determination of Quartz Crystals

Characterization of Satellite Frequency Up-Converters Application Note

EENG-201 Experiment # 4: Function Generator, Oscilloscope

EXHIBIT 7: MEASUREMENT PROCEDURES Pursuant 47 CFR 2.947

Banded Millimeter Wave Network Analysis TECHNICAL OVERVIEW

Keysight Technologies PNA Microwave Network Analyzers

Understanding RF and Microwave Analysis Basics

Swept Return Loss & VSWR Antenna Measurements using the Eagle Technologies RF Bridge

PXIe Contents. Required Software CALIBRATION PROCEDURE

Reconfigurable 6 GHz Vector Signal Transceiver with I/Q Interface

Technologies Vector Reflectometers

S5 (PMR-446) Model Programming software for S5 (PMR-446) Model

Application Note: Swept Return Loss & VSWR Antenna Measurements using the Eagle Technologies RF Bridge

Exercise 5: Power amplifier measurement

Keysight Technologies UWB Antenna Measurements with the 20 GHz E5071C ENA Network Analyzer. Application Note

Keysight 2-Port and 4-Port Broadband Network Analyzer

Microwave Metrology -ECE 684 Spring Lab Exercise I&Q.v3: I&Q Time and Frequency Domain Measurements

How to calibrate the VNWA sensitivity in Spectrum Analyzer mode

Amplifier Test Bench Taking performance to a new peak

Spectrum Analyzers 2680 Series Features & benefits

Keysight 2-Port and 4-Port PNA Network Analyzer N5221B 10 MHz to 13.5 GHz N5222B 10 MHz to 26.5 GHz

Xeta4. Occupied Bandwidth. Measurements

P a g e 1 ST985. TDR Cable Analyzer Instruction Manual. Analog Arts Inc.

Understanding the Precision Antenna, Cable, and Power Measurements on the 3550 Radio Test System

Keysight Technologies External Source Control X-Series Signal Analyzers Option ESC. Demo Guide

About the HDSDR software operations for the IC-R8600

Agilent AN How to Characterize CATV Amplifiers Effectively

Pulsed VNA Measurements:

RF Path Characterization

Keysight X-Series Signal Analyzers

Agilent 4-Port PNA-L Network Analyzers

Keysight Technologies Measuring Group Delay of Frequency Converters with Embedded Local Oscillators. Application Note

Spectrum Analyzer R&S FS300

FCC 47 CFR PART 15 SUBPART C CERTIFICATION TEST REPORT FOR. Bluetooth Remote Control for Video Set Top Box MODEL NUMBER: IPRC1000 FCC ID: 2ABTE-L3YJC9

TEST EQUIPMENT PLUS. Signal Hound USB-SA44B / USB-TG44A. Application Note 1: The Smith Chart. Rev. 0

Summary. Output bench. Frequency Response Signal to Noise Ratio Crosstalk, One Channel Undriven Interchannel Phase Input bench.

FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 BLUETOOTH LOW ENERGY CERTIFICATION TEST REPORT FOR. 2.4GHz LE MODULE MODEL NUMBER: RN4020

DEPARTMENT OF THE ARMY TECHNICAL BULLETIN

Agilent Technologies Gli analizzatori di reti della serie-x

Keysight Technologies Nonlinear Vector Network Analyzer (NVNA) Breakthrough technology for nonlinear vector network analysis from 10 MHz to 67 GHz

Keysight Technologies E5080A ENA Series Network Analyzer. - 9 khz to 4.5/6.5/9 GHz

Lab Reference Manual. ECEN 326 Electronic Circuits. Texas A&M University Department of Electrical and Computer Engineering

A Test Lab Techno Corp. Report Number:1410FR27

ELECRAFT KX3 EXTENDED VFO TEMPERATURE COMPENSATION PROCEDURE Copyright 2012 Elecraft LLC Rev. A9, November 14, 2012

Antenna Measurement using Vector Network Analyzer. Jong-hwan Keum Agilent Technologies

Instrument Messages and Functional Tests

December 2012 Number Linearity Testing in the SureCAL Power Sensor Package FLEXIBLE STANDARDS ASSIGNMENT

Agilent Pulsed Measurements Using Narrowband Detection and a Standard PNA Series Network Analyzer

AV3672 Series Vector Network Analyzer

Conversion Gain Measurements on Mixers with Different Input and Output Impedances

Agilent CSA Spectrum Analyzer

Spectrian Dual Mode Cellular Power Amplifier Model No.: SCLPA 800 CR FCC ID: I2ONTHX51AA

Keysight Technologies Basics of RF Ampliier Measurements with the E5072A ENA Series Network Analyzer

E5071C ENA Vector Network Analyzer. E5092A Configurable Multiport Test Set

MDX420 Input Level Field Calibration Procedure AN227 Rev. 1.0

Agilent CSA Spectrum Analyzer

Agilent N5250A PNA Millimeter-Wave Network Analyzer 10 MHz to 110 GHz

PXIe Contents. Required Software CALIBRATION PROCEDURE

DSA-815 Demo Guide. Solution: The DSA 800 series of spectrum analyzers are packed with features.

Contents. CALIBRATION PROCEDURE NI PXIe-5668R 14 GHz and 26.5 GHz Signal Analyzer

Overcoming Mixer Measurement Challenges

Keysight Technologies E5080A ENA Vector Network Analyzer. - 9 khz to 4.5/6.5/9 GHz

A Selection of R.F. Wattmeters optimized for console, remote, and mobile applications.

Using the FREQUENCY CONVERSION Mode of Vector Network Analyzer ZVR

6. 6dB &26dB Bandwidth Test

PGT313 Digital Communication Technology. Lab 6. Spectrum Analysis of CDMA Signal

Agilent 8510 Network Analyzer Product Note A

Siglent Technologies SSA3021X Spectrum Analyzer and TG-SSA3000X Tracking Generator Reviewed by Phil Salas AD5X

Model 7000 Series Phase Noise Test System

Transcription:

IMD and RF Power Measurements with the Keysight PNA-X N5249A Simone Rusticelli IRA Technical Report N 505/17 Reviewed by: Federico Perini

Table of contents IMD and RF Power Measurements with the Keysight PNA-X N5249A... 1 List of figures... 6 Introduction... 7 1. Without Option... 8 1.1. Source Power Calibration... 8 1.2. Receiver Power Calibration... 11 2. With Option 423... 13 2.1. Source Power Calibration... 13 2.2. Receiver Power Calibration... 15 3. Instrument set up to acquire IP2, IP3... 16 4. Instrument set up to measure the Gain... 18 5. RF power measurement with USB power sensor... 19 5

List of figures Figure 1 - Source Power Calibration without Option 423.... 8 Figure 2 PNA-X path configuration.... 9 Figure 3 PNA-X Power and Attenuators configuration menu.... 10 Figure 4 PNA-X Source Power Calibration and Power Meter Settings menu.... 10 Figure 5 PNA-X message after Source Power Calibration.... 11 Figure 6 - Receiver Power Calibration bench setup without Option 423.... 11 Figure 7 - PNA-X message after Receiver Power Calibration.... 12 Figure 8 - Source Power Calibration bench setup with Option 423.... 13 Figure 9 PNA-X path configuration.... 14 Figure 10 - Receiver Power Calibration bench setup with Option 423.... 15 Figure 11 Measurement setup (left: without Option 423, right: with Option 423).... 17 6

Introduction The aim of this Technical Report is to explain how to manually configure and calibrate the Keysight N5249A 4 port PNA-X to make frequency sweep IP2, IP3, Gain and RF power sensing (with USB power sensor HP U2004A) measurements simultaneously, without using Keysight s upgrade options. The PNA-X has been purchased in 2015 with only the Frequency Offset (Option 080), that means the ability to tune the receiver at frequencies other than those of the transmitter. In 2016 has been upgraded with the Internal Combiner & Mechanical Switches (Option 423) that adds an internal mechanical combiner which combines RF signals from two sources internally, simplifying test setups for two-tone measurements. Another Upgrade was made in 2016 with the Source-Corrected Noise Figure Measurements (Option 029) that adds the possibility to make Noise measurements with the cold source method using the PNA-X. This technical report explains the procedure for calibration and measurement of non-linearity s RF devices with or without the upgrade of the Option 423. 7

1. Without Option 1.1. Source Power Calibration Before calibrating is necessary to make a proper setup of the instrument: I. Stimulus Frequency Frequency offset..:set to OFF II. The channel that will be calibrated must contain all the frequencies for the measurements (i.e. frequency span must be greater than the frequencies that will be measured: from [2f1min-f2min] to [2f2max-f1max] for IMD3 and [2f1, f1+f2 and 2f2] for the IMD2) III. Set up Power&Attenuation, IFBW and number of points desired. Set up the connection as in Errore. L'origine riferimento non è stata trovata.: Figure 1 - Source Power Calibration without Option 423. 8

Figure 2 PNA-X path configuration. Response Calibration Power Calibration Source Power Calibration (see Figure 3) 1. Stimulus Power & Attenuation Set Port1 ON and other ports OFF. Set Power Offset=0dB in the display window (now has been calibrating source port 1) Channel&Source Port selection: Ch.1 Port 1 i. Options Use Power Meter (Select: Calib the PNA ref. receiver, see Figure 4) OK ii. Power Meter Configuration Select: USB iii. Sensor Internal Zero Zero OK Exit from Sensor and select (in Power Meter Settings window) Take Calibration Sweep. If everything goes well it will be displayed: PASS. 2) Stimulus Power & Attenuation Set Port3 ON and other ports OFF. Set Power Offset=0dB in the display window (now has been calibrating source port 3) Channel&Source Port selection: Ch.1 Port 3 i. Options Use Power Meter (Select: Calib the PNA ref. receiver) OK ii. Power Meter Configuration Select: USB iii. Sensor Internal Zero Zero OK 9

Figure 3 PNA-X Power and Attenuators configuration menu. Figure 4 PNA-X Source Power Calibration and Power Meter Settings menu. Exit from Sensor and select (in Power Meter Settings window) Take Calibration Sweep. If everything goes well it will be displayed: PASS. In the bottom bar will be displayed SrcPwrCal (see Figure 5). 10

Figure 5 PNA-X message after Source Power Calibration. 1.2. Receiver Power Calibration Set up the connection as in Figure 6 to make the Receiver Power Calibration. Figure 6 - Receiver Power Calibration bench setup without Option 423. Stimulus Power & Attenuation Set Port1 ON and other ports OFF. 1. Right click in the trace Measure Receiver section Activate B Source Port1 2. Response Receiver Power Next Take Receiver Cal Sweep Next Finish In the bottom bar will be displayed C:Response (as in Figure 7). 11

It is recommended to save the instrument state: Figure 7 - PNA-X message after Receiver Power Calibration. File Save As.. Save as Type State and Cal Set Data (*.csa). 12

2. With Option 423 2.1. Source Power Calibration Before calibrating is necessary to make a good setup of the instrument: I. Frequency offset: OFF II. The channel that will be calibrated must contain all the frequencies for the measurements (i.e. frequency span must be greater than the frequencies that will be measured: from [2f1min-f2min] to [2f2max-f1max]) for IMD3 and [2f1, f1+f2 and 2f2] for the IMD2) III. Set up IFBW and number of points desired. IV. In Stimulus Power Path Configuration Configuration (window menu) select Port 1 2-Tone. Set up the connection as in Figure 8: Figure 8 - Source Power Calibration bench setup with Option 423. 13

Figure 9 PNA-X path configuration. Response Calibration Power Calibration Source Power Calibration 2. Stimulus Power & Attenuation Set Port1 ON and other ports to OFF. Set Power Offset=0dB in the display window (now has been calibrating source port 1) Channel&Source Port selection: Ch.1 Port 1 i. Options Use Power Meter (Select: Calib the PNA ref. receiver) OK ii. Power Meter Configuration Select: USB iii. Sensor Internal Zero Zero OK Exit from Sensor and select (in Power Meter Settings window) Take Calibration Sweep. If everything goes well it will be displayed: PASS. 3) Stimulus Power & Attenuation Set Port1 Src2 ON and other ports OFF. Set Power Offset=0dB in the display window (now has been calibrating source physical port 1 named Port1 Src2) Channel&Source Port selection: Ch.1 Port 1 Src 2 i. Options Use Power Meter (Select: Calib the PNA ref. receiver) OK ii. Power Meter Configuration Select: USB iii. Sensor Internal Zero Zero OK Exit from Sensor and select (in Power Meter Settings window) Take Calibration Sweep. 14

If everything goes well it will be displayed: PASS. In the bottom bar will be displayed SrcPwrCal (see Figure 5). 2.2. Receiver Power Calibration Set up the connection as in Figure 10 to make the Receiver Power Calibration. Figure 10 - Receiver Power Calibration bench setup with Option 423. Stimulus Power & Attenuation Set Port1 ON and other ports to OFF. 3. Right click in the trace Measure Receiver section Activate B Source Port1 4. Response Receiver Power Next Take Receiver Cal Sweep Next Finish In the bottom bar will be displayed C:Response (see Figure 7). It is recommended to save the instrument state and calibration File Save As.. Save as Type State and Cal Set Data (*.csa). 15

3. Instrument set up to acquire IP2, IP3 Recall of Source&Receiver Power Calibration (File Recall..) Now is necessary to set the instrument to acquire an IMD measurement, with a variable central frequency and fixed tone spacing of 1MHz, varying RF power. First of all the PNA-X must be set up in Frequency Offset mode. To add IP3 measurement, must be followed the points below: 1) Set up PNA-X to display tone1 (f1) in channel1: Stimulous Frequency Offset: a) select Primary setting the range test frequencies; * b) set up Frequency Sweep; c) Source 1 is fc-f1: -500kHz, multiplier=1; d) Source 2 is fc-f2: +500kHz, multiplier=1; e) Receiver is the frequency at which we want the receiver will be tuned (-500kHz, tone1). 2) Measure Receiver select Activate B (RX port2) from the second drop-down menù, / 1.0 and Port 1 than Apply. 3) Stimulus Power & Attenuation Enable (ON) port1 and 3, while disable porte2 and 4. Repeat 3 times point 1) (copying Channel 1) changing with: tone2 (f2), IMD3L (2f1-f2) and IMD3H (2f1-f2) changing only point 1.e) with the correspondent Receiver frequency (+500kHz,-1500kHz e +1500kHz). Moreover should be set up correctly section 2) for every channel. For a better trace reading, name s trace can be edited. From the previous 4 traces already done could be created IP3 traces. In section Marker Analysis Analysis Equation Editor typing the IP3 calculus equation: Trace2 x sqrt (Trace2/Trace4) [in db: ½*(3f1-IMD3)] It is possible to create a worst case formula taking into account the worst case: min(tone1,tone2) x sqrt (min(tone1,tone2)/max(imd3l,imd3h)) * Frequency range must be chosen taking into account the frequencies which will be measured with the receivers (2f1-f2 for the lowest and 2f2-f1 for the highest), not to exit the frequency range of the desired measuring points. 16

4) To add an IP2 measurement, points 1 to 3 must be repeated with the following changes: Trace Tone IP2: Stimulous Frequency Offset: - Primary: [fstart:fstop/2]; - Source 1: -500kHz, multiplier=1; - Source 2: +500kHz, multiplier=1; - Receiver: one of the 2 fundamental tones for example tone1, -500kHz). Trace HD2: In Stimulous Frequency Offset: - Primary: [fstart:fstop/2]; - Source 1: -500kHz, multiplier=1; - Source 2: +500kHz, multiplier=1; - Receiver: correspond to 2fC so Receiver should be 0Hz, Multiplier = 2. Trace OIP2: Using the equation editor and typing the following formula: Tone IP2 x (Tone IP2 / HD2) [in db: 2f1-HD2)] Figure 11 Measurement setup (left: without Option 423, right: with Option 423). 17

4. Instrument set up to measure the Gain To create a Gain trace: Trace Measure Receiver Activate B / R1 and Source Port 1. Is recommended to save the instrument state. 18

5. RF power measurement with USB power sensor 1. Frequency Offset must be set to OFF and Sweep Type to Frequency Sweep; 2. Add the USB Power Sensor in the PNA-X: Utility Configure External Device Configuration Set USB interface and, clicking Refresh, select the Power Sensor correspondent address adding to the external device s list (can be useful give it a name as Power Meter to recognize it); 3. Create a trace to measure the RF power vs frequency: Measure Receivers enable A select the Power Meter instrument in the window drop down menu Numerator than press OK. Credentials for the remote control: User: PNA-Admin Password: pna 19