CALCULATING AND OPTIMIZING ACCURACY & REPEATABILITY of NATURAL GAS CUSTODY TRANSFER FLOW MEASUREMENTS UNDER INSTALLED CONDITIONS

Similar documents
UTILIZING ADVANCED MEASUREMENT DIAGNOSTICS TO IMPROVE POWERPLANT/POWERPLANT AVAILABILITY

MEASUREMENT, TRANSMITTERS AND FILTERING

Accurate Low Flow Rate Measurement Using a Specially Designed Differential Pressure Type Flowmeter

Field Devices and Wiring

Go New-Tech or Stick With DP Meters?

Operational Experiences

Liquid Ultrasonic Flow Meters

White Paper. Vortex Shedding Tutorial. What s Inside: Invensys is now

To Calibrate or Not to Calibrate a fieldbus transmitter? Dale Perry Pressure Marketing Manager Rosemount

The SFC 1000PA P2DAAA can be mounted on a prover trailer, which can be moved from field to field to provide proving services.

RCM DIRECT READING FLOWMETER

Industrial Instrumentation

CORIOLIS METER FOR CUSTODY TRANSFER APPLICATION PERFORMANCE OF THE FOXBORO CFS20 CORIOLIS METER AND CFT50 TRANSMITTER WITH SMALL VOLUME PROVER

Process Leak Detection Diagnostic with Intelligent Differential Pressure Transmitter

TRANSMITTER CALIBRATION

ADDMAS CORIOLIS MASS FLOW METER

PAD - Heavy Duty Differential Pressure Trasmitter

Fieldbus Foundation India Committee. Fieldbus Foundation Asset Management and Diagnosis Automation-2010, India

Micro MV P2DAAA. Custody transfer accuracy Built-in multivariable 3-in-1 transmitter. Daily. Zigbee wireless radio. Extended length battery backup

A NOVEL METHOD OF RATIO CONTROL WITHOUT USING FLOWMETERS

Advancements in Clamp-on Ultrasonic Flow Measurements Biosolids Workshop December 1 st 2016

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Application of ultrasonic clamp-on flow meters for in situ tests of billing meters in district heating systems

LOW POWER FLOW COMPUTERS Greg Phillips Bristol Babcock Inc Governors Circle West, Suite F, Houston, TX 77092

LZYN Triangle Series Mass Flow Meter

Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys

Operating Manual. Differential Pressure Transmitter DPS 100

Advanced instrumentation solutions crafted with highest precision

2. Basic Control Concepts

Top Design Considerations for Low-Power Metering Applications

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Spirit IT Flow-X High accuracy flow computers

Advanced Test Equipment Rentals ATEC (2832) Clamp-on Ultrasonic Flow Meter Family

General Specifications

Project Experience, April 2009

OPTIMASS 1000 Technical Datasheet

TI25 - Pre-Instructional Survey

LEVEL TECHNOLOGIES TO POWER THE FUTURE

RUNYI GROUP AJ FLOW TOTALIZER. Features

DavidsonSensors. Fiber Optic Sensing System Definitions. Davidson Fiber Optic Sensing System

Basics of continuous level measurements. By Gene Henry, Level Product Marketing Manager, Endress+Hauser. d = c 2

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Brooks Models SLAMf50, SLAMf51, SLAMf53 Mass Flow Controllers and Models SLAMf60, SLAMf61, SLAMf63 Mass Flow Meters

Introduction to Measurement Systems

Compact Orifice Flow Meter

VELTRON II Microprocessor Based Pressure & Flow Smart

Flow Measurement SITRANS F US Inline

Rosemount 8700 Series. Magnetic Flowmeter Systems. Rosemount 8700 Series. Product Data Sheet , Rev TA April 2009.

Refinery: Application: Hot Liquids Coker Feed Challenge Applications. Coker feed liquid is Hot Viscous Chunky Dangerous

Application Note 221. A New Coaxial Flow Calorimeter for Accurate RF Power Measurements up to 100 Watts and 1 GHz

CALYS 150. Advanced documenting multifunction calibrator thermometer

Possible installation effects on density meter in a fast loop sampling system.

Liquid & Gas Flowmetering

The World Market for Pressure Transmitters, 3 rd Edition

Fundamentals of Instrumentation & Process Control

Flow Technologies Overview. For internal use only / Siemens AG All Rights Reserved.

Peter Dack, Vice President Sales & Marketing Radian Research, Inc.

Transmitters BROCHURE

OPTITEMP. Compact sensors

Instrumentation and Control Technician A Guide to Course Content Implementation Beginning with Level 1 April 2013

Coaxial Flow Calorimeter for Accurate RF Power Measurements up to 100 Watts and 1 GHz

CoriolisMaster Measurement made easy Accurate flow measurement of liquids and gases

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

STATUTORY INSTRUMENTS SUPPLEMENT No th June, 2016 STATUTORY INSTRUMENTS SUPPLEMENT

APPLICATION NOTE 695 New ICs Revolutionize The Sensor Interface

CALYS 150. Advanced documenting multifunction calibrator thermometer

SMART LASER SENSORS SIMPLIFY TIRE AND RUBBER INSPECTION

Current loop output (4...20mA) for a volt pressure transmitter

FGM 160 Ultrasonic Flaregas meter. Flare Gas Measurement

Technical Bulletin, Communicating with Honeywell TM ST3000/STT3000 Smart Transmitters

MINCO PRODUCTS, INC Commerce Lane, Minneapolis, Minnesota U.S.A. Telephone: (763) FAX: (763)

HD 9408T BARO - HD 9408TR BARO HD 9908T BARO - HD 9408PS 50

SFC Smart Field Communicator Model STS103. Specification 34-ST /24/06. Description. Function. Page 1 of 5

ST 3000 Fieldbus Transmitter Series 100 Models

Chapter IX Using Calibration and Temperature Compensation to improve RF Power Detector Accuracy By Carlos Calvo and Anthony Mazzei

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters. 4/18 Siemens FI

OPTITEMP TT 20 Technical Datasheet

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI

FOUNDATION Fieldbus: the Diagnostics Difference Fieldbus Foundation

TS16 - Pre-Instructional Survey

Model Sono-Trak Transit Time

Noise Figure Definitions and Measurements What is this all about?...

Webinar Organizers. Ryan Shea. Don Miller. Joe Ryan. Support Specialist. Applications Specialist. Product Manager. Precision Digital Corporation

The Anderson Loop: NASA s Successor to the Wheatstone Bridge

Materials (other materials see WIKA diaphragm seal program) Model S-10

E-Chart Image Release History

Module 1: Introduction to Experimental Techniques Lecture 2: Sources of error. The Lecture Contains: Sources of Error in Measurement

PART XIII Fidelity and Security of Measurement Data

Statistic evaluation of deviation between guaranteed and measured turbine efficiency

Smart Electromagnetic Flowmeter Open channel Flowmeter Detector

APT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL

Anthony Chu. Basic Accelerometer types There are two classes of accelerometer in general: AC-response DC-response

Output performance: Analogue output accuracy check. Pulse output accuracy check.

UFM 800 W, C Ultrasonic flowmeter for water and wastewater

SPRAY DROPLET SIZE MEASUREMENT

Rosemount 333 HART Tri-Loop

Increasing security. Saving space. Gaining flexibility. Signal Conditioners for Industrial Automation

Proven Measurement for A World of Applications

Sarasota CM200 Sarasota HME900 Density Converter Electronics

GS.No.GBN062E-5. GENERAL SPECIFICATIONS Sensor unit

Transcription:

CALCULATING AND OPTIMIZING ACCURACY & REPEATABILITY of NATURAL GAS CUSTODY TRANSFER FLOW MEASUREMENTS UNDER INSTALLED CONDITIONS Mark Menezes, Manager, Pressure Applications (Americas) Eric Wickberg, Senior Engineer, Pressure Applications (Americas) Les Callender, Business Development Manager, South-Central USA Rosemount Inc. KEYWORDS Measurement, Installed Repeatability, Natural Gas, Ultrasonic, Linear, DP Flowmeter ABSTRACT Modern flow meters used for natural gas custody transfer offer very high accuracy and repeatability typically 1% of mass flow for orifice meters, and often better for linear meters. These specifications are usually verified in a flow laboratory. Unfortunately, even with a wellinstalled and maintained meter, every flow technology provides worse performance in the real world. This paper presents the key reasons for this deviation between laboratory and real world performance, and tools that allow the user to quantify expected deviations prior to installation. Finally, best practices are detailed which will allow the user to minimize the difference between laboratory and real-world performance. Why is Accuracy and Repeatability Worse in the Real-World than in the Laboratory? Even with a well-installed and well-maintained flowmeter, real-world accuracy can be significantly worse than laboratory accuracy, for any flow technology. The reason for this is that real-world flowmeters are not installed and operated under laboratory conditions : Rigidly controlled ambient temperature Low static line pressures Devices calibrated before every test (no drift) Ambient Temperature Variation: In the vast majority of real-world custody transfer flow measurements, transmitters are installed outdoors. In some climates, ambient temperatures can easily vary up to 50 degf from calibration temperature. While the AGA (and ISO) requires users to compensate for fluid temperature variation, these ambient temperature variations can have an even larger effect, especially with older, analog transmitters. These effects can be easily simulated on the bench blow warm air over a transmitter, and watch its output change. With orifice meters, ambient temperature variation affects the DP transmitter and the static pressure transmitter. With linear meters, ambient temperature variation will affect any analog components in the flowmeter, as well as the static pressure transmitter used for pressure 1

compensation. Even if actual line pressure is constant, the output of a static pressure transmitter and hence the calculated mass flow - will vary with varying ambient temperature. High Static Line Pressures: In the case of orifice meters, the differential pressure transmitter used to infer flow can be significantly affected by a high line pressure. To simulate this effect on the bench, the user should apply a small differential pressure across a transmitter. Then, add several hundred pounds of additional static pressure to both sides of the transmitter. In theory, the measured differential pressure should not change. In reality, it does. Drift/Stability: The output of any analog component will vary over time. As with the ambient temperature effect described above, this can affect all flow technologies. Better, smart transmitters are more stable than older, analog transmitters or transducers. Within regulatory and contractual restrictions, a more stable transmitter will allow the user to obtain equivalent accuracy and repeatability when calibrated less frequently. An inferior device will need to be calibrated more frequently to maintain acceptable performance. How Can the User Quantify the Impact of Real-World Sources of Error? Reputable suppliers publish specifications which allow the user to calculate and predict the impact of these and other real-world effects on installed flow accuracy and repeatability. For the purposes of this paper, a spreadsheet was designed (Appendix 1) which uses published specifications to calculate flow error caused by the DP transmitter in an orifice meter installation. The results at 100% flow, under typical installed conditions, are shown in Figure 2. Figure 2 - Flow Error from DP Transmitter ReferenceAccuracy Ambient Temp (+/- 25oF) Line Pressure (300 psig) Drift (12 months) "Better".075% ref accy "Worse".075% ref accy Analog (.2% ref accy) 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 Flow Error at 100% Flow (%) Note that: Reference (laboratory) accuracy is a trivial component of total transmitter installed error. Two DP transmitters with identical 0.075% reference accuracies can provide dramatically different installed accuracies. If a supplier does not publish specifications for real-world effects, this does not mean that their products are immune to these effects usually, the reverse is true. 2

Although the example of an orifice meter is used for illustration, installed accuracy is worse than laboratory accuracy for all flow technologies, including but not limited to ultrasonic, PD, turbine and Coriolis. Figures 3 & 4 show the impact of this error at lower flowrates. Note that: these errors apply to accuracy and repeatability, and are fixed over the entire DP range DP α flow 2 since DP declines twice as fast as flow, small errors at 100% - and small differences in transmitter accuracy - are magnified at lower flowrates Figure 3 Flow Error from DP Transmitter Flowrate (scfm) DP "Better".075% "Worse".075% Analog 1000 100 0.09% 0.21% 0.65% 750 50 0.16% 0.38% 1.16% 500 25 0.37% 0.85% 2.60% 250 6.25 1.48% 3.40% 10.40% Seemingly trivial improvements in transmitter accuracy yield significantly better flow accuracy and repeatability at normal flows the effect is dramatic at lower flows. 6% Figure 4 - Flow Error from DP Transmitter Flow Error (%) 4% 2% "Worse".075% Analog "Better" 0.075% 0% 20% 40% 60% 80% 100% Flowrate (%) What is the Impact of the Static Pressure Transmitter on Repeatability of a Linear Meter? Both linear and DP flowmeters require additional static pressure transmitters to compensate for changes in density from changing line pressure. From the AGA-7 (turbine) and AGA-9 (ultrasonic) equations, a change of line pressure of 1% results in a change in calculated mass flow of 1%. For this reason, an error of 1% in the static pressure transmitter results in an error of 1% in calculated flow. 3

As with the DP transmitter used in the orifice meter shown above, the static pressure transmitter used in the linear meter can be more or less repeatable, depending upon the device selected and the operating conditions. Ironically, while linear and ultrasonic flowmeters typically provide better laboratory accuracy and repeatability than orifice meters, they often include built-in analog pressure transducers instead of true smart transmitters for pressure compensation. Transducers are usually comparable to analog transmitters, providing much worse installed performance than smart transmitters. They are also usually fixed range, which means that a small error at the transducer s full scale will become magnified at lower pressures. Figure 5 shows the installed flow repeatability error contributed by the static pressure transmitter. Note that: As with the DP transmitter used in the orifice meter, reference accuracy is again a trivial component of installed performance the flow repeatability error contributed by an inaccurate analog pressure transmitter or transducer can be much greater than the error from the ultrasonic or turbine meter itself. Figure 5 Flow Repeatability Error from Static Pressure Transmitter Ref Accy Ambient Temp (25 degf) Drift (6 months) "Better" 0.075% Analog 0.00% 0.20% 0.40% 0.60% 0.80% 1.00% Flow Repeatability Error What is the Impact of Dynamic Performance? Flows which vary quickly or which pulsate require fast measurements for good accuracy and repeatability. To achieve a fast measurement with a pressure transmitter both the DP transmitter used with an orifice meter and the static pressure transmitter used for the linear and orifice meter - the user should: minimize impulse line time delays and close couple the transmitter to the pipe select a transmitter with fast response Note that there are vast differences in dynamic response both between and within different flow technologies. For example, Figure 6 shows response times for a variety of transmitters which are widely used in natural gas custody transfer. In some cases, the supplier will publish specifications; however, these results are often obtained only through testing. 4

Figure 6 Response Times for Differential Pressure Transmitters 24.0 Pressure R eleased 20.0 16.0 Output in 12.0 8.0 Td 4.0 Tc 0.0-0.4-0.2 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 Tim e in Sec What are the Best Practices? In any custody transfer application, a true random uncertainty has an equal chance of favoring either party, the net impact should be zero to both parties, and measurement accuracy and repeatability should not be valued. The reality of course is that most sellers do value measurement accuracy and repeatability for the simple reason that many users install check meters. Discrepancies between a billing meter and a check meter especially those that favor the seller can cause demands for independent auditing or even retroactive reimbursement. Repeatability is usually more important than accuracy while a consistent discrepancy between the billing and check meter can be biased out, poor repeatability cannot be corrected. Therefore, the first step in designing any custody transfer system is to determine the mutual measurement performance expectations of the supplier and the user over the range of flowrates. This determination of mutual performance expectations should be made by individuals who have a clear understanding of all of the costs of measurement disputes caused by poor repeatability. The second step is to quantify the operating conditions which are not controllable. For a flow measurement, these can include: expected ambient temperature variation maximum static line pressure static line pressure and temperature variation maximum allowable permanent pressure loss flow turndown expected frequency of flow variation and/or pulsation 5

The third and final step is to select hardware and installation and maintenance procedures which will ensure that the measurement provides the required installed performance under the expected (uncontrollable) operating conditions. For example, the user can: - select a static and/or differential pressure transmitter which has better or worse performance under the given real-world operating conditions - calibrate the transmitter(s) frequently or infrequently - in the case of a DP flowmeter, size the primary element for a higher or lower differential pressure (higher DP s provide higher accuracy, at the expense of higher pressure loss) - select a flowmeter and pressure transmitter with faster or slower response - use long or short impulse lines, or direct connect for fastest response While the first and second steps involve gathering data, the third step may require calculations and/or testing, which may be facilitated by the spreadsheet shown in the Appendix. Conclusion Most flowmeters provide excellent accuracy and repeatability under laboratory conditions. Unfortunately, under real-world conditions, which may include: changing ambient temperature high static line pressures drift between calibrations the same flowmeters will provide worse performance. Using published specifications, it is possible to calculate prior to installation the impact of these real-world effects on installed flowmeter performance. This will allow the user to both predict installed performance for any given application and flow technology, but also to select transmitters which will meet the needs of the specific application. 6

Appendix 1: TPFE.XLS The Total Probable Flow Error (TPFE) spreadsheet calculates flow error due to the DP transmitter, using: user-entered application conditions manufacturers published specifications and clearly shows all calculations. The TPFE.xls spreadsheet runs in Microsoft Excel, and is available at www.rosemount.com. Total Probable Flow Error Due to DP Transmitter does not include effect of process pressure/temperature variation or Fluid / Service: Transmitter Calibrated Span: Ambient Temp. Variation: Static Line Pressure: Calibration Frequency: Natural Gas to Boiler #1 0-100 in H20 Maximum Flow: 1000 scf/min 25 deg F Normal Flow: 500 scf/min 300 psig Value of Fluid:.002 $ / scf 18 months DP Transmitter flow error at normal flow (500 DP Transmitter Annual Value "Best" Flow Flow Improvement "Better".075% Transmitter 0.37% $ 1920 - *Annual "Worse".075% Transmitter 0.85% $ 4457 $ 2537 flow Analog (.2%) 2.60% $ 13682 $ 11762 (accuracy/repeatabili "Better".075% Transmitter - 3051 Improvemen "Worse".075% Transmitter $ 2537 Analog (.2%) $ 11762 Ref. Accuracy Flow error at normal flow (500 Ambient Temp. Static Press. Drift (Stability) 0.0% 0.5% 1.0% 1.5% 2.0% 2.5% 3.0% Flow 7