MNRS Redundant RF Detector/Switch Module

Similar documents
D3.1/CCAP Compliant HFC. Enhance. C-Cor HECE1G 1GHz Line Extender (with AGC) INSTALLATION & OPERATION MANUAL.

Q-SERIES. Optical. QFQR 200A-04 Series Return Path Optical Receiver. Installation & Operation Manual

Q-SERIES Power. BAQ-UP (QRED) Redundancy Switch with Backup Amplifier INSTALLATION & OPERATION MANUAL.

Q-SERIES. Amplifiers. QPAIR Redundancy Switch Amplifier System. Installation & Operation Manual

SMACSM Frequency Agile Pilot Carrier Redundancy Source

SignalOn Series. RF Passive Modules INSTALLATION & OPERATION MANUAL. 1.2 GHz. D3.

D3.1 / CCAP Compliant

Ultra-Dense RF & Optical Active Modules Combiners

D3.1 / CCAP Compliant. 1.2 GHz. SignalOn Series. Forward Path Amplifier Products. Installation & Operation Manual

CCAP Compliant. Discontinued

Status Monitoring And Control Solutions. (HMS Compliant, SNMP Based) SMAC SM PCR Pilot Carrier Redundancy Platform. Installation & Operation Manual

D3.1 / CCAP Compliant. 1.2 GHz. Make-Before-Break (MBB) Splitter/Combiner Module Specifications

SignalOn Series. Passive Modules Splitter/Combiner Modules. Features. Specifications Make-Before-Break (MBB) Splitter/ Combiner Module. 1.

SignalOn Series WHITE PAPER. Impact of CCAP on RF Management Isolation. Pat. #s U.S. 6,842,348; 7,043,236; Cdn. 2,404,840; 2,404,844

HFC. Enhance. QFHPN High Power Optical Node with AGC Installation & Operation Guide

Chromadigm CHS/CHQ Transmitter

RF Signal Management. RF Signal Management. Active & Passive Products* Passives: Actives:

ChromaFlex. ChromaFlex DMT24, DMT34 & DMT44 Multi-Wavelength DWDM Direct Modulated Transmitter Module HARDWARE INTERFACE MANUAL.

SignalOn Series. RF Signal Management. Active & Passive Products* Passives: Actives:

200B Clipper Module User Manual

MODEL AF200A: FM, FM/SCA RECEIVER/MONITOR OPERATION MANUAL

DC200A Displacement Clipper User Manual

I-HUB Chassis. Hardware Interface Manual

Lazerpoint TM RF RX-91 Basic Receiver Installation Instructions

201AP Charge Amplifier User Manual

Anacon Power & Controls

10-Gbit/s 850-nm VCSEL Model 1780

Prisma II Optical Receivers

Rev /13 SSRMAN-1B SERIES USERS MANUAL SSR INTELLIGENT BURST FIRING CONTROL COPYRIGHT 2013 NUWAVE TECHNOLOGIES, INC.

Instruction Manual Model M Switch, DPDT, Manual Select

B031 DUAL PILOT TONE DETECTOR

2.5 GHz 1310 nm Laser Model 1732

Model 4402B. Ultra-Pure Sinewave Oscillator 1Hz to 110kHz Typical Distortion of % Serial No. Operating Manual

INSTRUCTION MANUAL MODEL 2779 SUBCARRIER MODULATOR

Chromadigm-IR CIR - Integrated RFoG Transmitter

DST-2000C. Direction Sensing Tachometer INSTRUCTION MANUAL

25-Gbit/s, 850-nm VCSEL

SERVICE BULLETIN. Description: VOX\ICS Tie Line Subassembly Document #: AMS44\603-0 Service Bulletin #: 002

INSTRUCTION MANUAL. March 11, 2003, Revision 3

Model Hz to 10MHz Precision Phasemeter. Operating Manual

PTR-1500 AUDIO TONE TELEPROTECTION TERMINAL FEATURES DESCRIPTION

INSTRUCTION MANUAL MODEL 2455T SUBCARRIER MODULATOR

Rev.8 03/08 SSRMAN-1P SERIES USERS MANUAL SSR INTELLIGENT PHASE ANGLE CONTROL MODULE COPYRIGHT 2008 NUWAVE TECHNOLOGIES, INC.

33609/J Limiter/Compressor

PLUG N PLAY WATT DIGITAL FM TRANSMITTER. April, 2002 IM No

Boulder W Class A Stereo Power Amplifier

Model 7000 Low Noise Differential Preamplifier

PERMA Series Revision 2 Amplifiers

IRT Eurocard. Type AG-738. Stereo Audio Phase / Failure Detector

G3L Multi-Carrier Power Amplifier Installation and Service Manual

ACA2417: 1218 MHz CATV Push-Pull Driver Amplifier

SPECIAL NOTICE. All references to NAT product part numbers (and associated images) are equivalent to AEM product part numbers.

EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Page/Talk Hazardous Area Paging Amplifier

MABEL, PiTone and Allstar for the Yaesu Fusion DR-1X Repeater

CDS-302 Automatic Composite Switcher/Distribution Amplifier

1.0 General Description

OPERATORS MANUAL CP 52

CXD-Q 8-Channel Amplifier

PARALLEL MULTI-AMP KIT for 7200 Series AMPLIFIERS INSTRUCTION SHEET

Model 9302 Amplifier-Discriminator Operating and Service Manual

ACA2431: 1218 MHz High-Output GaN CATV Power-Doubler Amplifier

ACA2431: 1218 MHz High-Output GaN CATV Power-Doubler Amplifier

Why Modern Servicing Requires Complete Waveform & Circuit Analyzing!

Page/Talk Weatherproof Wall Stations Models MLW80 and MLW85

10-MHz Adjustable Photoreceivers Models 2051 & 2053

GCX. Guitar Audio Switcher OWNER S MANUAL

C-Band Redundant LNA Systems

Anacon Power & Controls Relay Assembly Specialists An Anacon Electronic Sales, Inc. Company

Explosion Proof Page/Talk Paging Amplifier

1 MHz to 8 GHz, 70 db Logarithmic Detector/Controller AD8318-EP

CALIBRATED IMPULSE GENERATOR MODEL CIG khz 1 GHz

LM3189 FM IF System. LM3189 FM IF System

INSTALLATION AND OPERATING INSTRUCTIONS MODEL SIVF. KB Part No Signal Isolator for KBVF Controls. See Page 1 Pending

X-Band Redundant LNA Systems

APPLICATION NOTE LZY-1 ULTRA-LINEAR RF AMPLIFIER. 20 MHz MHz 25 WATTS MIN., 1 db COMPRESSION (50 WATTS TYP., MAX. OUTPUT)

2045 PAB700-FM-A1. Efficiency: 65% Temperature Range: -20 to 70 C Max VSWR: 2.5 :1. Class: Supply Voltage:

TONE ALERT RECEIVER MODEL 2TR9A. P.O. Box West Pacific. Lexington, NE 68850

T25-35SA Subaudible Tone Decoder

Chameleon Labs. Model 581. Discrete Class AB Microphone Preamplifier Module Owner s Manual

Model 34A. 3Hz to 2MHz 2-Channel Butterworth/Bessel HP, LP, BP, BR Plug-In Filter Card for Model 3905/3916 Chassis.

Si4825-DEMO. Si4825 DEMO BOARD USER S GUIDE. 1. Features. Table 1. Si4825 Band Sequence Definition

MD10C 10A DC Motor Driver

Rev.8.8 SSRMAN-1P SERIES USERS MANUAL SSR INTELLIGENT PHASE ANGLE CONTROL MODULE COPYRIGHT 2015 NUWAVE TECHNOLOGIES, INC.

125-MHz Photoreceivers Models 1801 and 1811

Page/Talk Wall Stations

DCS-E 3kW Series DC Power Supplies

Independent Technology Service Inc Independence Ave. Chatsworth, California Toll Free:

Autonomous Robot Control Circuit

301 & 601 Mic/Line Mixers Operation Manual

High-Speed Data Communication LA310Z 8.3 GHz Differential Limiting Amplifier 16-pin Plastic QFN Package

SCR CONTROLLER SYSTEM

MAAM CATV 75 Ω Push Pull Amplifier MHz Rev. V2. Features. Functional Schematic. Description. Pin Configuration 3

Programmable K-Factor Scaler B and Programming Software Kit B

MAAP STD Power Amplifier, 2 W GHz Rev. V2 Features Functional Schematic Description Pin Configuration2 Ordering Information1

Series 3000 Model R-107A

Flow Detection MDS Integral or Remote Housing. Installation and Operating Instructions

1.0 General Description

Models 1421 and 1422 User s Manual. Broadband Amplifiers

GPS Splitter 2 in 16 Rack Mount Splitter

Transcription:

Pat. #s U.S. 6,842,348; 7,043,236; Cdn. 2,404,840; 2,404,844 D3.1 / CCAP Compliant MNRS Redundant RF Detector/Switch Module Installation & Operation Manual

Although every effort has been taken to ensure the accuracy of this document it may be necessary, without notice, to make amendments or correct omissions. Specifications subject to change without notice. SignalOn Series, MAXNET, HFC Enhance, PCI Filters, Q-Series & FiberLinx are registered trademarks of ATX in the United States and/or other countries. SMAC SM is a service mark of ATX in the United States and/or other countries. Products or features contained herein may be covered by one or more U.S. or foreign patents. Other non-atx product and company names in this manual are the property of their respective companies.

TABLE OF CONTENTS Page 1. OPERATION... 1-1 1.1. Operational Details... 1-1 1.2. Operational Summary... 1-1 2. SET-UP... 2-1 2.1. Redundant Amplifier Applications... 2-1 2.2. RF Detector A/B Switch Applications... 2-2 3. THRESHOLD LEVEL SETTINGS... 3-1 3.1. Coarse Setting (3-9 db) - Recommended... 3-1 3.2. Fine Setting (3 db) - Advanced... 3-1 4. DEVICE RESET... 4-1 4.1. Redundant Amplifier Configurations... 4-1 4.2. RF Detector A/B Switch Configurations... 4-1 5. SERVICE & SUPPORT... 5-1 5.1. Contact ATX Networks... 5-1 5.2. Warranty Information... 5-1 MAXNET MNRS Redundant RF Detector/Switch Module Installation & Operation Manual i

Index of Figures Figures #1 MNRS Functional Schematic Diagram...1-1 #2 MNRS Wiring Configuration...2-1 #3 MNRS Wiring Configuration...2-2 #4 MNRS Front Panel Bar Graph Display...3-1 ii MAXNET MNRS Redundant RF Detector/Switch Module Installation & Operation Manual

CHAPTER 1: OPERATION OPERATION 1. Operation 1.1. Operational Details The MAXNET MNRS RF switch provides redundancy in an RF amplifier system. When a failure occurs in the primary amplifier (A) control transfers to a secondary backup amplifier (B). The failure of the amplifier is determined by measuring the total composite RF power at the output of the primary (A) amplifier and comparing it to the set RF power threshold level. If total composite RF power drops below the threshold level the MNRS transfers to the secondary (B) amplifier to maintain normal operation. The switch remains in the B position until the primary (A) amplifier is repaired or replaced and the MNRS is reset. FROM A RF OUT FROM B TO A RF IN TO B RF RF DETECTOR CONTROL LOGIC RF (dbmv) THD (dbmv) THD SET THD RLY NO RLY COM (Schematic indicates operation when device is not powered) Figure #1: MNRS Functional Schematic Diagram 1.2. Operational Summary Installation into MAXNET Chassis: Install the MNRS into the MAXNET chassis by following the MAXNET RF Detector/Switch and Amplifier Installation sheet provided with the unit. Threshold Setting: Front panel SET THD potentiometer. Reset: Front panel momentary push button press to set primary (A) amplifier active. Switch Status: Front panel LED and Relay Contact on rear terminal block. Power Failure: Switch Transfers to B position when MNRS power is lost. NOTE: This device is not intended for exact power measurements. It is intended to make a nominal total composite RF power measurement and compare it to a user defined threshold in order to determine the necessary switch status MAXNET MNRS Redundant RF Detector/Switch Module Installation & Operation Manual 1-1

CHAPTER 1: OPERATION This page left intentionally blank. 1-2 MAXNET MNRS Redundant RF Detector/Switch Module Installation & Operation Manual

CHAPTER 2: SET-UP SET-UP 2. Set-up 2.1. Redundant Amplifier Applications Once the MAXNET chassis is powered, the amplifiers are connected to the MNRS (see Figure #2 below), review Section 3 for procedures on how to set the threshold level. Figure #2: MNRS Wiring Configuration MAXNET MNRS Redundant RF Detector/Switch Module Installation & Operation Manual 2-1

CHAPTER 2: SET-UP 2.2. RF Detector A/B Switch Applications Once the MAXNET chassis is powered and the MNRS is configured as shown in Figure #3, review Section 3 for procedures on how to set the threshold level. Figure #3: MNRS Wiring Configuration 2-2 MAXNET MNRS Redundant RF Detector/Switch Module Installation & Operation Manual

CHAPTER 3: THRESHOLD LEVEL SETTINGS THRESHOLD LEVEL SETTINGS 3. Threshold Level Settings 3.1. Coarse Setting (3-9 db) - Recommended Adjust the SET THD potentiometer fully CCW Press and release the reset (RESET) push button: the B ACTIVE LED should turn off the RF PWR level bar graph should indicate a level between 40 and 70 dbmv Adjust the SET THD potentiometer CW: obtain a reading on the THD bar graph one bar below that indicated on the RF bar graph (see Figure #4 below) NOTE: Threshold (THD) should not be set greater than 15 db below RF Power (RF) indicator level. Figure #4: MNRS Front Panel Bar Graph Display (Threshold set for 3-9 db) 3.2. Fine Setting (3 db) - Advanced Adjust the SET THD potentiometer fully CCW Press and release the reset (RESET) push button: the B ACTIVE LED should turn off the RF PWR level bar graph should indicate a level between 40 and 70 dbmv Connect a DVM (Fluke 87 or equiv.) between the RF test point (black - negative lead) and the THD (red - positive lead) Adjust the SET THD potentiometer CW: obtain a reading on the DVM of -150 mv (-3 db) NOTE: Voltage scaling for RF and THD test points is 50 mv/db MAXNET MNRS Redundant RF Detector/Switch Module Installation & Operation Manual 3-1

CHAPTER 3: THRESHOLD LEVEL SETTINGS This page left intentionally blank. 3-2 MAXNET MNRS Redundant RF Detector/Switch Module Installation & Operation Manual

CHAPTER 4: DEVICE RESET DEVICE RESET 4. Device Reset 4.1. Redundant Amplifier Configurations After the MNRS has switched (B ACTIVE LED on and the RF bar graph blank), the operator should determine the cause of the transfer from primary amplifier A to backup amplifier B. Once the cause has been identified and corrected: Ensure that the wiring is correct Press and release the reset (RESET) push button: the B ACTIVE LED should turn off the RF PWR level bar graph should indicate a level between 40 and 70 dbmv 4.2. RF Detector A/B Switch Configurations No reset required. Device returns to primary mode when signal source A returns to a power level above the threshold level. MAXNET MNRS Redundant RF Detector/Switch Module Installation & Operation Manual 4-1

CHAPTER 4: DEVICE RESET This page left intentionally blank. 4-2 MAXNET MNRS Redundant RF Detector/Switch Module Installation & Operation Manual

CHAPTER 5: SERVICE & SUPPORT SERVICE & SUPPORT 5. Service & Support 5.1. Contact ATX Networks Please contact ATX Technical Support for assistance with any ATX products. Please contact ATX Customer Service to obtain a valid RMA number for any ATX products that require service and are in or out-of-warranty before returning a failed module to the factory. RF Products (MAXNET, SignalOn, HFC Enhance, PCI Filters, Q-Series, SCN, SMAC, FiberLinx) TECHNICAL SUPPORT Tel: (905) 428-6068 press *3 then press 2 Toll Free: (800) 565-7488 press *3 then press 2 (USA & Canada only) Email: rfsupport@atxnetworks.com CUSTOMER SERVICE ATX Networks 1-501 Clements Road West Ajax, ON L1S 7H4 Canada Tel: (905) 428-6068 press *1 Toll Free: (800) 565-7488 press *1 (USA & Canada only) Fax: (905) 427-1964 Toll Free Fax: (866) 427-1964 (USA & Canada only) Email: support@atxnetworks.com Web: www.atxnetworks.com 5.2. Warranty Information All of ATX Networks products have a 1-year warranty that covers manufacturer s defects or failures. MAXNET MNRS Redundant RF Detector/Switch Module Installation & Operation Manual 5-1

1-501 Clements Road West, Ajax, ON L1S 7H4 Canada Tel +1 (905) 428-6068 Toll Free +1 (800) 565-7488 Fax +1 (905) 427-1964 Toll Free Fax +1 (866) 427-1964 www.atxnetworks.com support@atxnetworks.com Printed in Canada Rev. 10/17 (ANW0543)