General-purpose Relay MY New model Versatile and Function-filled Miniature Power Relay for Sequence Control and Power Switching Applications Models with lockable test buttons now available. Many variations possible through a selection of operation indicators (mechanical and LED indicators), lockable test button, built-in diode and CR (surge suppression), bifurcated contacts, etc. Arc barrier standard on -pole Relays. Dielectric strength:,000 VAC (coil to contact) Environment-friendly cadmium-free contacts. Safety standard approvals obtained. Wide range of Sockets (PY, PYF Series) and optional parts are available. Max. Switching Current: -pole: 0 A, -pole: A Provided with nameplate. LR Ordering Information Relays Standard Coil Polarity Type Contact form Plug-in socket/solder terminals Without LED indicator Standard with LED indicator With LED indicator and lockable test button Standard DPDT MYN MYIN MY PDT MYN MYIN MY PDT (bifurcated) MYZN MYZIN MYZ With built-in diode DPDT MYN-D MYIN-D --- (DC only) PDT MYN-D MYIN-D --- PDT (bifurcated) MYZN-D MYZIN-D --- With built-in CR DPDT MYN-CR MYIN-CR --- (0/0 VAC, 0/0 VAC only) PDT MYN-CR MYIN-CR --- PDT (bifurcated) MYZN-CR MYZIN-CR --- Reverse Coil Polarity Type Contact form Plug-in socket/solder terminals With LED indicator With LED indicator and lockable test button Standard (DC only) DPDT MYN MYIN PDT MYN MYIN PDT (bifurcated) MYZN MYZIN With built-in diode DPDT MYN-D MYIN-D (DC only) PDT MYN-D MYIN-D PDT (bifurcated) MYZN-D MYZIN-D Note: When ordering, add the rated coil voltage and (s) to the model number. Rated coil voltages are given in the coil ratings table. Example: MY 6VAC (S) New model Rated coil voltage General-purpose Relay MY New model
Accessories (Order Separately) Sockets Poles Front Mounting Socket (DIN-track/ screwless clamp [SLC]) Front-mounting Socket (DIN-track/ screw mounting) PYF0S PYF0A-E PYF0A-N PYFS PYFA-E PYFA-N PYF-ESS PYF-ESN Back-mounting Socket Solder terminals Wire-wrap terminals PCB terminals Without clip With clip Without clip With clip PY0 PY0-Y PY0QN PY0QN PY PY-Y PYQN PYQN PY0QN-Y PY0QN-Y PYQN-Y PYQN-Y PY0-0 PY-0 Socket Hold-down Clip Pairing Relay type Poles Front Mounting Socket (DIN-track/screwless clamp [SLC]) Without -pole test button -pole test button PYF0S PYCM-0S PYF0A-E PYF0A-N PYFS PYCM-S PYFA-E PYFA-N PYF-ESS PYF-ESN PYF0S PYCM-0S PYF0A-E PYF0A-N Mounting Plates for Sockets Note: PYP- and PYP-6 can be cut into any desired length in accordance with the number of Sockets. Track and Accessories Front-connecting Socket (DIN-track/ Back-connecting Socket screw mounting) Solder/Wire-wrap terminals PCB terminals Socket Clip Socket Clip Socket Clip PYC-A PY0(QN) PYC-P PYC-P PYC0 (metal) PYC (plastic) PY(QN) PY0-0 PY-0 PYC-P PYC-P PYC-E PY0(QN) PYC-P PY0-0 PYC-P Socket model For Socket For Sockets For 6 Sockets PY0, PY0QN(), PY, PYQN() PYP- PYP- PYP-6 Supporting Track (length = 00 mm) Supporting Track (length =,000 mm) End Plate Spacer PFP-0N PFP-00N, PFP-00N PFP-M PFP-S Specifications Coil Ratings Rated voltage Rated current Coil resistance Coil inductance (reference value) Must operate voltage Must release voltage Max. voltage Power consumption (approx.) 0 Hz 60 Hz Arm. OFF Arm. ON % of rated voltage AC 6 V*. ma ma. Ω 0.0 H 0.0 H 0% max. 0% min. 0%.0 to. VA V 06. ma ma 6 Ω 0.7 H 0. H (60 Hz) V. ma 6 ma 0 Ω 0.6 H.0 H /0 V*.7/.7 ma./.0 ma 7 Ω. H.66 H 0/0 V./0. ma./. ma,0 Ω.0 H. H 0. to. VA (60 Hz) 0/0 V./. ma./.6 ma,70 Ω.0 H 6. H DC 6 V* ma. Ω 0.7 H 0. H 0% min. 0. W V 7 ma 60 Ω 0.7 H.7 H V 7.7 ma 66 Ω.0 H.7 H V*. ma,60 Ω 0.60 H.0 H 00/0 V.0/. ma,00 Ω.60 H 6. H Note:. The rated current and coil resistance are measured at a coil temperature of C with tolerances of +%/ 0% for rated currents and ±% for DC coil resistance.. Performance characteristic data are measured at a coil temperature of C.. AC coil resistance and impedance are provided as reference values (at 60 Hz).. Power consumption drop was measured for the above data. When driving transistors, check leakage current and connect a bleeder resistor if required.. Rated voltage denoted by * will be manufactured upon request. Ask your OMRON representative. General-purpose Relay MY New model
Contact Ratings Rated load Item -pole -pole -pole (bifurcated) Resistive load (cosφ = ) A, 0 VAC A, 0 VDC Note: Don t exceed the carry current of a Socket in use. Please see page 0. Characteristics Note: The values given above are initial values. Inductive load (cosφ = 0., L/R = 7 ms) A, 0 VAC A, 0 VDC Endurance Characteristics Resistive load (cosφ = ) A, 0 VAC A, 0 VDC Carry current 0 A (see note) A (see note) Max. switching voltage Max. switching current Max. switching power Failure rate (reference value) 0 VAC VDC 0 A A,00 VA 00 W,0 VA 00 W 0 VAC VDC,0 VA 0 W Inductive load (cosφ = 0., L/R = 7 ms) 0. A, 0 VAC. A, 0 VDC 00 VA 0 W Resistive load (cosφ = ) A, 0 VAC A, 0 VDC,0 VA 0 W VDC, ma VDC, ma VDC, 00 µa Inductive load (cosφ = 0., L/R = 7 ms) 0. A, 0 VAC. A, 0 VDC 00 VA 0 W Item All Relays Contact resistance 00 mω max. Operate time 0 ms max. Release time 0 ms max. Max. operating frequency Mechanical:,000 operations/hr Electrical:,00 operations/hr (under rated load) Insulation resistance,000 MΩ min. (at 00 VDC) Dielectric strength,000 VAC, 0/60 Hz for.0 min (,000 VAC between contacts of same polarity) Vibration resistance Destruction: 0 to to 0 Hz, 0. mm single amplitude (.0 mm double amplitude) Malfunction: 0 to to 0 Hz, 0. mm single amplitude (.0 mm double amplitude) Shock resistance Destruction:,000 m/s Malfunction: 00 m/s Endurance See the following table. Ambient temperature Operating: C to 70 C (with no icing) Ambient humidity Operating: % to % Weight Approx. g Pole Mechanical life (at,000 operations/hr) Electrical life (at,00 operations/hr under rated load) -pole AC:0,000,000 operations min. 00,000 operations min. -pole DC:00,000,000 operations min. 00,000 operations min. -pole (bifurcated) 0,000,000 operations min. 00,000 operations min. General-purpose Relay MY New model
Approved Standards VDE Recognitions (File No. 67UG, IEC, VDE 0) No. of poles Coil ratings Contact ratings Operations 6,,, /0, 00/0 0/0, 00/0, 0/0 VAC 6,,,, 00/0, VDC UL0 Recognitions (File No. ) CSA C. No. Listings (File No. LR) IMQ (File No. EN0 to 06) LR Recognitions (File No. /00) SEV Listings (File No.. 00.0) 0 A, 0 VAC (cosφ=) 0 A, 0 VDC (L/R=0 ms) A, 0 VAC (cosφ=) A, 0 VDC (L/R=0 ms) 0 x 0 00 x 0 MYZ AC; 0 x 0 No. of poles Coil ratings Contact ratings Operations 6 to 0 VAC 6 to VDC 0 A, 0 VDC (General purpose) 0 A, 0 VAC (General purpose) A, 0 VAC (General purpose) A, 0 VDC (General purpose) 6 x 0 No. of poles Coil ratings Contact ratings Operations 6 to 0 VAC 6 to VDC 0 A, 0 VDC 0 A, 0 VAC A, 0 VAC (Same polarity) A, 0 VDC (Same polarity) 6 x 0 No. of poles Coil ratings Contact ratings Operations 6,,, /0, 00/0 0/0, 00/0, 0/0 VAC 6,,,, 00/0, VDC 0 A, 0 VDC 0 A, 0 VAC A, 0 VAC A, 0 VDC 0 x 0 00 x 0 MYZ AC; 0 x 0 No. of poles Coil ratings Contact ratings Operations 6 to 0 VAC 6 to VDC 0 A, 0 VAC (Resistive) A, 0 VAC (PF0.) 0 A, 0 VDC (Resistive) A, 0 VDC (L/R=7 ms) A, 0 VAC (Resistive) 0. A, 0 VAC (PF0.) A, 0 VDC (Resistive). A, 0 VDC (L/R=7 ms) 0 x 0 0 x 0 No. of poles Coil ratings Contact ratings Operations 6 to 0 VAC 6 to VDC 0 A, 0 VAC 0 A, 0 VDC 0 x 0 A, 0 VAC A, 0 VDC 00 x 0 MYZ AC; 0 x 0 General-purpose Relay MY New model
Endurance (x0 operations) Endurance (x0 operations) Endurance (x0 operations) Endurance (x0 operations) Switching current (A) Switching current (A) Engineering Data Maximum Switching Power MY MY, MYZ AC resistive load AC inductive load (cosφ=0.) AC resistive load AC inductive load (cosφ=0.) DC resistive load DC resistive load DC inductive load (L/R=7 ms) DC inductive load (L/R=7 ms) Switching voltage (V) Switching voltage (V) Endurance MY (Resistive Loads) MY (Inductive Loads) 0000 0000 000 000 000 0 VAC 000 0 VAC 000 000 0 VDC 00 00 0 VDC 0 VDC 00 00 0 VDC 00 0 VAC 00 0 VAC 0 0 0 0 0 0 MY (Resistive Loads) Switching current (A) MY (Inductive Loads) Switching current (A) 0000 0000 000 000 000 0 VAC 000 0 VDC 000 000 00 00 0 VDC 0 VDC 00 00 0 VAC 0 VDC 00 0 0 0 VAC 00 0 0 0 VAC 0 0 Switching current (A) Switching current (A) General-purpose Relay MY New model
Endurance (x0 operations) Endurance (x0 operations) MYZ (Resistive Loads) 0000 000 000 MYZ (Inductive Loads) 0000 000 000 000 00 00 0 VAC 0 VDC 000 00 00 0 VDC 0 VDC 00 0 0 0 VDC 0 VAC 00 0 0 0 VAC 0 VAC 0 0 Switching Current (A) Switching Current (A) Technical and Environmental Properties -Pole model -Pole model Tracking Resistance 600 CTI (base) 600 CTI (base) Environmental Protection RT RT Flammability Class Base, Insulator, Spool ul V-0 Case, Indicator, Nameplate, Push Button ul V- Pollution Degree Creepage Distance.0 mm. mm Clearance Distance.0 mm.0 mm Contact Material Ag AgNi + Au 6 General-purpose Relay MY New model
Typical information for reference only The following data is provided as experimental and/or calculated data for reference only. These figures fall under the category of typical behaviour and the operation of individual relays will vary according to the exact operating conditions. Typical Operate / Release Times -Pole model -Pole model AC Type (operate / release time) ms/ ms 0 ms/0 ms DC Type (operate / release time) ms/ ms ms/6 ms Load reduction Factor For AC inductive loads (such as solenoids, contactors coils, etc.) the reduction factor corresponding to cos(p.f.) (cosine of the power factor) is multiplied by the rated current in order to identify the maximum allowable current. This approximation is not valid for loads with high inrush currents 0. such as electric motors or fluorescent lamps. Reduction factor 0.6 0. 0. 0.6 0. 0. cos(p.f.) Multiple Contact DC Switching Capacity Switching capacity of DC resistive load 00 Effect of temperature on coil voltages MY/ Operating range (DC and AC type) vs ambient temperature Switching Current (A) 0 MY U/Un..0 contacts contacts contacts in series 0, 0 0 60 0 00 0 0 60 0 00 0 Switching Voltage (Vdc) MY This graph can be used to estimate the number of contacts that can be used to switch DC resistive loads 0. : Max coil voltage permitted. : Min pick-up voltage with coil at ambient temperature 0 0 0 0 0 0 60 70 0 Ambient temperature ( C) This graph shows the typical relationship between the maximum / minimum coil and pick-up voltage and ambient temperature General-purpose Relay MY New model 7
Dimensions Note: All units are in millimeters unless otherwise indicated. -Pole Models MYN.6 Eight,. dia.. long holes 0. max. 6 max. 6.. max. -Pole Models MYN.6 Eight,. dia.. long holes 0. max. 6 max. 6.. max. Models with Test Button MYIN.6. 0. 6. 6 max. Eight,. dia.. long holes. max. max. MYIN.6. 0. 6. 6 max. <.7> 0. Fourteen,. dia.. long holes 6.. max. max. General-purpose Relay MY New model
Terminal Arrangement/Internal Connections (Bottom View) MY MYN/MYIN (AC Models) MYN/MYIN (DC Models) MYN-D/MYIN-D (DC Models Only) + + MYN-CR/MYIN-CR (AC Models Only) MYN/MYIN (DC Models Only) MYN-D/MYIN-D (DC Models Only) + + MY(Z) MY(Z)N/MY(Z)IN (AC Models) MY(Z)N/MY(Z)IN (DC Models) MY(Z)N-D/MY(Z)IN-D (DC Models Only) 6 7 6 7 6 7 6 7 0 0 + + MY(Z)N-CR/MY(Z)IN-CR (AC Models Only) MY(Z)N/MY(Z)IN (DC Models Only) MY(Z)N-D/MY(Z)IN-D (DC Models Only) 6 7 6 7 6 7 0 + + Note: The DC models have polarity. General-purpose Relay MY New model
Socket for MY Track-mounted (DIN Track) Socket Conforms to VDE 006, Part 00 Snap into position along continuous sections of any mounting track. Facilitates sheet metal design by standardized mounting dimensions. Design with sufficient dielectric separation between terminals eliminates the need of any insulating sheet. Safety Standards for Sockets Model Standards File No. PYF0A-E, PYF0A-N UL0 E7 PYFA-E, PYFA-N CSA. LR PYF-ESN, UL0 E PYF-ESS CSA. LR76 Back-connecting Sockets Specifications Item Pole Model Carry current Dielectric withstand voltage Insulation resistance (see note ) Screwless Clamp PYF0S 0 A,000 VAC, min Less than,000 MΩ Terminal Socket PYFS A Track-mounted PYF0A-E 7 A,000 VAC, min,000 MΩ min. Socket PYF0A-N (see note ) 7 A (see note ) PYFA-E A PYFA-N (see note ) A (see note ) PYF-ESN/-ESS A > kv > MΩ Back-connecting PY0(-Y) 7 A,00 VAC, min 00 MΩ min. Socket PY0QN(-Y) PY0-0 PY(-Y) A PYQN(-Y) PY-0 Note:. The values given above are initial values.. The values for insulation resistance were measured at 00 V at the same place as the dielectric strength.. The maximum operating ambient temperature for the PYF0A-N and PYFA-N is C.. When using the PYF0A-N or PYFA-N at an operating ambient temperature exceeding 0 C, reduce the current to 60%.. The MY(S) can be used at 70 C with a carry current of 7 A. 0 General-purpose Relay MY New model
Dimensions Note: All units are in millimeters unless otherwise indicated. PYF0S Socket Dimensions Terminal arrangement/ Internal connections (top view). max. 6. max. Mounting holes. max. --- max. (.) PYF0A-E Two,. x mounting holes Eight, M x sems screws Two, M, M, or.-dia. holes 7 max. (TOP VIEW) max. max. Note: Track mounting is also possible. Refer to page for supporting tracks. PYF0A-N max. 67 max..7.0 dia.. dia. or M PYF-0A-N 7 A A A A A A Note: Track mounting is also possible. Refer to page for supporting tracks. 0 max. General-purpose Relay MY New model
PYFS Socket Dimensions Terminal arrangement/ Internal connections (top view) 6. max. Mounting holes max. --- max. PYFA-E Two,. x mounting holes Fourteen, M x sems screws Two, M, M, or.-dia. holes 7 max.. max. max. (TOP VIEW) Note: Track mounting is also possible. Refer to page for supporting tracks. PYFA-N 7 6 7 6 Two,. dia. or M 67 max. PYF-A-N 0 7 6 A A A. max. 0 max. 0 A A A Note: Track mounting is also possible. Refer to page for supporting tracks. General-purpose Relay MY New model
Socket Dimensions Terminal arrangement/ internal connections (top view)/ mounting holes PYF-ESN 7. Label 7... NO NC Relay. 6. 6.. 7 COIL COM.. Module 0 PYF-ESS 7 6 COM. NO. 7... NC. 6. 6. COIL. General-purpose Relay MY New model
Socket Dimensions Terminal arrangement/ Internal connections (bottom view) Mounting holes PY0/PY0-Y (See note) Eight, x. elliptical holes. max.. max. PY0QN/ PY0QN-Y max. 0 max. max. Note: The PY0-Y includes sections indicated by dotted lines. (See note). max. max.. max. max. max. Note: The PY0QN-Y includes sections indicated by dotted lines. PY0-0. max.. max. 6. max. max. Eight,.-dia. holes PY/PY-Y (See note) Fourteen, x. elliptical holes. max.. max. max. 0 max. max. Note: The PY-Y includes sections indicated by dotted lines. PYQN/ PYQN-Y (See note). max. PY-0 max.. max. max. max. Note: The PYQN-Y includes sections indicated by dotted lines.. max.. max. 6. max. max. Fourteen,.-dia. holes Note: Use a panel with plate thickness of to mm for mounting the Sockets. General-purpose Relay MY New model
Hold-down Clips PYC-A ( pcs per set) 6. PYC-E ( pcs per set) 6. For sockets PYF-ESN/-ESS Model PYC 0 PYC PYC TR Description Metal spring clip (Used with Relay only) Plastic holding clip (Used with Relay only) Thermoplastic writeable label....±0..7. Note: For total dimensions with plastic clip please refer to drawings of the sockets. PYC-P PYC-P 0 max... Mounting Plates for Back-connecting Sockets PYP- Two,.-dia. holes PYP-6 7 elliptical holes PYP- t=.6 7 elliptical holes Tracks and Accessories Supporting Tracks PFP-0N/PFP-00N. 7.±0. ±0. 7±0. 0 000 (00) * 0 () Note: The figure in the parentheses is for PFP-0N. General-purpose Relay MY New model
PFP-00N 6. ±0. 7. 0 000 0. End Plate PFP-M M x pan head screw 0 6.. 0.... 0 M spring washer.. Spacer PFP-S 6.. 6. Precautions Refer to General Precautions on page of the General-purpose Relays and Power Relays Group Catalog (X0). Connections Do not reverse polarity when connecting DC-operated Relays with built-in diodes or indicators or high-sensitivity DC-operated Relays. Mounting Whenever possible, mount Relays so that it is not subject to vibration or shock in the same direction as that of contact movement. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.07. To convert grams into ounces, multiply by 0.07. Cat. No. J0E-EN-0A In the interest of product improvement, specifications are subject to change without notice. OMRON EUROPE B.V. Wegalaan 67-6, NL- JD, Hoofddorp, The Netherlands Phone: + 6 00 Fax: + 6 www.eu.omron.com 6