Page 1/7 Illustrations Principle diagram See enlarged drawings at the end of document Product specification 10 GBit installation cable, simplex installation cable Cat.7A AWG 22 S/FTP with wires shielded in pairs 4 pairs (PiMF) pair shield: plastic foil with aluminum coating overall shield: tinned copper braid outer diameter 7.6 mm color of the cable jacket: blue coupling attenuation greater than or equal to 85 db applicable standards: EN 50173-1:2011-09; ISO/IEC 11801 Ed.2.2:2011-06; EN 50288-9-1 and IEC 61156-5 cable jacket: LSHF-FR (LSOH-FR) flame-retardant to IEC 60332-1/-2; IEC 60332-3-24; IEC 60754-1/-2 and IEC 64-1/-2 fire behaviour: Class Dca s2 d2 acc. EN 50399 Shipping Units: sold by meter on drum 1640 ft (500 m) on drum 3280 ft (0 m) on drum
Page 2/7 Technical Data General Data Design Installation cables Shielding shielded Transmission technology Copper Cable Type S/FTP Number of twisting elements 4 Twisting element Pair Color coding fiber/ wire(s) Color white/orange, orange, white/green, green, white/brown, brown, white/blue, blue blue Weight 62.00 kg/km Transmission characteristics Category (ISO) 7A Transmission rate up to 10 GBit IEEE 802.3an Transmission values (nominal) see table Connections/interfaces Termination data, solid wire (min. - max.) Conductor cross section, solid wire AWG 22/1 Conductor diameter, solid wire (bare copper) 0.62 mm Conductor diameter, solid wire (bare copper) 0.024 in. Core diameter (min. - max.) Core diameter (conductor with insulation) Core diameter (conductor with insulation) Cable sheath diameter (min. - max.) Cable sheath diameter Cable sheath diameter Copper index 1.5 mm 0.059 in. 7.8 mm 0.307 in. 30.5 kg/km Electrical characteristics Loop resistance max. 116 Ohm/km Transfer impedance 1 MHz max. 5 mohm/m Transfer impedance 10 MHz max. 5 mohm/m Transfer impedance 30 MHz max. 8 mohm/m Characteristic impedance 1- MHz +/-5 Ohm Coupling attenuation min. 85 db
Page 3/7 Technical Data Electrical characteristics Capacitance at 800 Hz Nom 43 nf/km Nominal velocity of propagation ca.76 % Delay skew max. 15 ns/ m Dielectric strength conductor-conductor (primarily) 0 V DC Dielectric strength conductor-conductor (secondary) 0 V DC Dielectric strength conductor-shield 0 V DC Segregation classification D Mechanical characteristics Tensile force 120 N Fire load 0.180 kwh/m Fire load 650 MJ/km Bending radius without load min. 35 mm Bending radius with load min. 70 mm Materials and material properties Material - Conductor Cu (copper) Material - Conductor Insulation Foam-Skin Polyethylen Material - Cable jacket LSHF-FR (LSOH-FR) Material - Pair shield plastic film Material - Pair shield finish Al (Aluminium) Material - Main shield Cu (copper) braid Material - Main shield finish Sn (tin) Flame retardancy yes Environmental conditions Temperature (min. - max.) Temperature - Storage C -20-60 C Temperature - Storage F -4-140 F Temperature - Operating C -20-60 C Temperature - Operating F -4-140 F Temperature - Installation C 0-50 C Temperature - Installation F 32-122 F
Page 4/7 Technical Data Approvals RoHS compliant The product meets the following standards Generic cabling systems General requirements ISO/IEC 11801 Ed.2.2: 2011-06 DIN EN 50173-1: 2011-09 Multi-element metallic cables used in analogue and digital communication and control Common test methods for cables under fire conditions Fire behaviour - class DIN EN 50288-9-1 Test for vertical flame propagation for a single insulated wire or cable Prüfung der vertikalen Flammenausbreitung an einer kleinen Ader, einer kleinen isolierten Leitung Test for vertical flame spread of vertically-mounted bunched wires or cables Measurement of smoke density of cables burning IEC 60332-1 Determination of the halogen acid gas content IEC 60754-1 Determination of acidity (by measuring the ph value) and conductivity IEC 60754-2 Klasse Dca s2 d2 nach EN 50399 IEC 60332-2 IEC 60332-3-24 IEC 64 Classifications ETIM 5.0 EC000830 ETIM 6.0 EC000830 Packing details Type of packaging meter / drum
Page 5/7 Accessories Designation 140302-01-E Jokari dismantle tool
Page 6/7 Illustrations Principle diagram
Page 7/7 Transmission values (nominal) Powered by TCPDF (www.tcpdf.org) as per Cat. 7A (at 20 C) FREQ MHz Attenuation (db/m) NEXT db min. PS-NEXT (db) ACR (db/ m) PS-ACR (db/ m) ELFEXT (db/ m) PS-ELFEXT (db/ m) Return loss (db) 1.0 4.0 10.0.0 250.0 500.0 600.0 862.0 0.0 1200.0 1.7 3.4 5.3 16.9 27 40 42 53 56 62 98 96 92 90 85 95 93 89 87 82 101 98 86 76 58 54 39 34 23 98 97 95 83 73 55 51 36 31 20 109 107 105 93 83 70 65 57 54 46 106 104 102 90 80 67 62 54 51 43 26 30 33 33 28 26 25 24 23 21