Data. Dr Murari Mohan Saha ABB AB. KTH/EH2740 Lecture 3. Data Acquisition Block. Logic. Measurement. S/H and A/D Converter. signal conditioner

Similar documents
Protective Relaying of Power Systems Using Mathematical Morphology

Transformer Protection

Solutions to Common Distribution Protection Challenges

THE ROLE OF SYNCHROPHASORS IN THE INTEGRATION OF DISTRIBUTED ENERGY RESOURCES

This webinar brought to you by The Relion Product Family Next Generation Protection and Control IEDs from ABB

www. ElectricalPartManuals. com Transformer Differential Relay MD32T Transformer Differential Relay

Modern transformer relays include a comprehensive set of protective elements to protect transformers from faults and abnormal operating conditions

Distance Relay Response to Transformer Energization: Problems and Solutions

Transmission Line Protection Objective. General knowledge and familiarity with transmission protection schemes

Unit Protection Differential Relays

Transmission Protection Overview

Differential Protection with REF 542plus Feeder Terminal

Analysis of Microprocessor Based Protective Relay s (MBPR) Differential Equation Algorithms

Power systems Protection course

Power System Protection Manual

Phase Comparison Relaying

www. ElectricalPartManuals. com Generator Differential Relay MD32G Rotating Machine Differential Relay

Bus protection with a differential relay. When there is no fault, the algebraic sum of circuit currents is zero

Symmetrical Components in Analysis of Switching Event and Fault Condition for Overcurrent Protection in Electrical Machines

Software Models for Relays

Negative-Sequence Based Scheme For Fault Protection in Twin Power Transformer

Transformer Protection Principles

EASUN REYROLLE LIMITED

Improved power transformer protection using numerical relays

Line Protection Roy Moxley Siemens USA

GE Multilin technical note

Transformer protection IED RET 670

Transformer Fault Categories

U I. Time Overcurrent Relays. Basic equation. More or less approximates thermal fuse. » Allow coordination with fuses 9/24/2018 ECE525.

Multimeter 500CVD21 RTU500 series

Hands On Relay School Open Lecture Transformer Differential Protection Scott Cooper

PROTECTION of electricity distribution networks

LAB #7: Digital Signal Processing

Catastrophic Relay Misoperations and Successful Relay Operation

Bus Protection Fundamentals

Shortcomings of the Low impedance Restricted Earth Fault function as applied to an Auto Transformer. Anura Perera, Paul Keller

COPYRIGHTED MATERIAL. Index

g GE POWER MANAGEMENT

International Journal of Advance Engineering and Research Development ANALYSIS OF INTERNAL AND EXTERNAL FAULT FOR STAR DELTA TRANSFORMER USING PSCAD

Distance Element Performance Under Conditions of CT Saturation

PROTECTION SIGNALLING

Power System Protection Part VII Dr.Prof.Mohammed Tawfeeq Al-Zuhairi. Differential Protection (Unit protection)

System Protection and Control Seminar

BUS2000 Busbar Differential Protection System

200ADM-P. Current Injection System with Phase Shift A 3.000s 2.000A 50.00Hz 0.0. Features

ISSN: Page 298

Performance Analysis of Traditional and Improved Transformer Differential Protective Relays

POWER SYSTEM II LAB MANUAL

Hands On Relay School Open Lecture Transformer Differential Protection Scott Cooper

Keywords: Transformer, differential protection, fuzzy rules, inrush current. 1. Conventional Protection Scheme For Power Transformer

Advantages of Analog Representation. Varies continuously, like the property being measured. Represents continuous values. See Figure 12.

Sequence Networks p. 26 Sequence Network Connections and Voltages p. 27 Network Connections for Fault and General Unbalances p. 28 Sequence Network

Transformer Protection

Summary Paper for C IEEE Guide for Application of Digital Line Current Differential Relays Using Digital Communication

Relaying 101. by: Tom Ernst GE Grid Solutions

Static Breaker Back-up Relay Type SBC Relay SBC231B

Impact of transient saturation of Current Transformer during cyclic operations Analysis and Diagnosis

Power System Protection. Dr. Lionel R. Orama Exclusa, PE Week 3

Z. Kuran Institute of Power Engineering Mory 8, Warszawa (Poland)

A New Adaptive High Speed Distance Protection Scheme for Power Transmission Lines

Relay-assisted commissioning

Stabilized Differential Relay SPAD 346. Product Guide

Detecting and Managing Geomagnetically Induced Currents With Relays

Introduction. Principle of differential relay operation

Module 2 : Current and Voltage Transformers. Lecture 8 : Introduction to VT. Objectives. 8.1 Voltage Transformers 8.1.1Role of Tuning Reactor

Centralized busbar differential and breaker failure protection function

Section 11: Power Quality Considerations Bill Brown, P.E., Square D Engineering Services

Chapter 7. Introduction. Analog Signal and Discrete Time Series. Sampling, Digital Devices, and Data Acquisition

PSCAD Simulation High Resistance Fault in Transmission Line Protection Using Distance Relay

Protection Basics Presented by John S. Levine, P.E. Levine Lectronics and Lectric, Inc GE Consumer & Industrial Multilin

SYNCHRONIZED PHASOR MEASUREMENT TECHNIQUES. A.G. Phadke

Substation Monitoring with TESLA

Generator Protection GENERATOR CONTROL AND PROTECTION

Numerical Quadrilateral Distance relay

System Protection and Control Subcommittee

Extensive LV cable network. Figure 1: Simplified SLD of the transformer and associated LV network

Pulse Code Modulation

Protection and control. Sepam range Sepam 2000 Metering and protection functions

Distance Protection: Why Have We Started With a Circle, Does It Matter, and What Else Is Out There? What Is a Distance Protection Element?

Performance Assessment of Distance Relay using MATLAB DibyaDarshiniMohanty, Ashwin Sharma, Ashutosh Varma M.S.I.T. M.S.I.T. M.S.I.

Switch-on-to-Fault Schemes in the Context of Line Relay Loadability

Relay Protection of EHV Shunt Reactors Based on the Traveling Wave Principle

La protection sélective des réseaux électriques

POWER TRANSFORMER PROTECTION USING ANN, FUZZY SYSTEM AND CLARKE S TRANSFORM

Improved differential relay for bus bar protection scheme with saturated current transformers based on second order harmonics

Ultra-High-Speed Relaying for Transmission Lines

Using a Multiple Analog Input Distance Relay as a DFR

New Smart Multi-Ended Differential Solution for Power Networks. GE Grid Solutions, UK

MAKING TRANSIENT ANTENNA MEASUREMENTS

Signals and Systems Lecture 9 Communication Systems Frequency-Division Multiplexing and Frequency Modulation (FM)

2015 Relay School Bus Protection Mike Kockott March, 2015

Earth Fault Protection

Experiment 9. PID Controller

Using High Speed Differential Amplifiers to Drive Analog to Digital Converters

EET 223 RF COMMUNICATIONS LABORATORY EXPERIMENTS

System Protection Schemes in Power Network based on New Principles

Proceedings of the 5th WSEAS Int. Conf. on SIMULATION, MODELING AND OPTIMIZATION, Corfu, Greece, August 17-19, 2005 (pp )

Analysis of Modern Digital Differential Protection for Power Transformer

Selected Problems of Induction Motor Drives with Voltage Inverter and Inverter Output Filters

1 INTRODUCTION 1.1 PRODUCT DESCRIPTION

Transcription:

Digital Protective Relay Dr Murari Mohan Saha ABB AB KTH/EH2740 Lecture 3 Introduction to Modern Power System Protection A digital protective relay is an industrial microprocessor system operating in real time It measures digitally the currents and/or voltages and/or some other signals associated with a protected element It applies in a digital way certain operating criteria to recognize automatically and fast whether or not a protected element suffers an internal fault In the case of an internal fault a relay asserts a tripping signal Digital Protective Relay Advantages Major Elements of a Digital Relay Accurate measurement More sophisticated operating principles Self-monitoring and improved availability Better security and dependability d Faster operation Communication, data storage, easy reprogramming, and other functional improvements voltages currents Data Acquisition Measurement Logic The major functional components of a digital relay are: Data Acquisition (analog filtering & sampling) Measurement (phasor estimation) Logic (tripping, alarming, carrier send, etc.) TRIP ALARM Data Acquisition Block Sampling Input Transducer Signal Conditioner Analog Filter S/H and A/D Converter The front-end of a digital relay consists of four elements: input transducer signal conditioner Analog anti-aliasing aliasing Filter (AF) Analog to Digital (A/D) converter 0.62 0.95 0.62 0.0-0.62-0.95 Sampling - taking samples of the analog input signal (usually at regular time intervals) and representing them in the sampled form Data Window 1

Sampling Frequency The sampling theorem: A signal to be reconstructed from its digital (sampled) form must be sampled at least twice in its period A given relaying principle uses certain frequency components from its input signals. The highest frequency component determines the minimum sampling frequency The higher the sampling frequency, the better representation of the analog signal Analog Filters AF is used to eliminate both the aliasing frequencies and the signal spectrum not utilized by the relay Usually a low-pass active filter of the order 2 (up to 4) with the cut-off frequency below half of the sampling rate is used Standard AF approximations are often used to provide optimal time and frequency responses AF introduces certain phase shift (time delay) between its input and output signals. This delay may slow down operation of a relay Word Length of an A/D Converter an A/D converter covers certain range of the input signal (2X max ) using certain number of bits (N) the minimum recognizable change of the signal assumes: X X = 2X max / 2 N Data Acquisition Conclusions The AF must be used to eliminate the aliasing frequencies; it may also eliminate some noise The sampling frequency must meet the needs of the applied relaying principle The word length of the A/D converter must meet the expected range of input signals for example, X max =100, N = 12, X=0.0488 12 bits are usually sufficient for the voltage channels 16 bits are sufficient for the current channels Phasor Definition Phasor Application A pure sine signal of a known frequency may be mathematically represented by two numbers: the magnitude and the phase The pair of the magnitude and phase is called a phasor Mathematically, a phasor is often denoted as a complex number: magnitude / phase Most of the contemporary digital relays are based on the classical relaying principles using phasors Those principles use phasors of the input signals and the relations between the phasors (such as impedance or power) to make the tripping decision Usually the phasors of the fundamental frequency components are used for protection 2

Phasor Estimation Requirements After a step change of a signal (due to a fault), the estimate of a phasor should reflect this change as fast as possible with the dynamic errors as small as possible The estimate of a phasor should not be sensitive to signal distortions such as off-nominal frequencies including the d.c. component, high- frequency noise, etc. Fourier Algorithm Fourier algorithm is often used in today s digital relays Mathematically, the Fourier algorithms is a linear transformation of input signal s s samples into a phasor In the Fourier algorithm the data window covers either a full cycle of the fundamental frequency (full-cycle algorithm) or half a cycle (half-cycle algorithm) Fourier Algorithm Properties Full-cycle algorithm: Response time (data window) of one full cycle Not sensitive to harmonics nor to the d.c. component Half-cycle algorithm: Response time (data window) of half of a cycle Not sensitive to odd harmonics Sensitive to the d.c. component and even harmonics Frequency Response Full cycle Fourier Phasor measurement Conclusions There is a number of different measuring algorithms developed for power system protection Short-window algorithms are fast but inaccurate; long-window algorithms are more accurate but slower Always certain compromise between the speed and accuracy requirements must be made Logic The logic block of a digital relay performs the following tasks; it applies certain characteristics to the measured signals (such as zones in an impedance relay) it applies certain timing functions (such as delay for the second zone trip in a distance relay) it asserts the relay outputs (such as the tripping signal, alarms, carrier send signal in a distance relay, etc.) 3

Overcurrent Relay An example of a digital relay The three major components of a digital overcurrent relay are: Data Acquisition unit Phasor measuring unit for estimation of the current amplitude Decision making unit for implementation of a given tripping characteristic Overcurrent Relay Design Issues Sampling frequency rate constant vs. variable Analog filter cut-off frequency order and approximation Vertical resolution Measuring algorithm Tripping logic Overcurrent Relay Modes of Operation Overcurrent Relay Tripping Logic Issues Instantaneous tripping Definite time tripping (a constant delay) Time dependent tripping t The way of resetting immediate reset delayed reset reversed timing when re-set The operating current present current amplitude used for reading the time-out parameter average amplitude used to time-out I Summary A digital relay is an on-off off controller which asserts its output signals (trip signal primarily) in the way of on-line computations Since an algorithm run on a relay determines the relay properties, there is a large space for research and improvement of digital relays Operating principle: : impedance seen from the relaying point is a measure of the distance to a fault, thus a base for trip/no-trip decision distance to fault Z 4

All the key elements of a digital distance relay, i.e., starting element (pick-up) phase selection element zone measuring elements power swing blocking element directional element tripping, carrier and alarm logic are realized in a digital way Starting Element Changes of certain signals can be measured very fast digitally enabling ultra-high speed activation of a relay Advanced principles can be used to start a relay (relative increase of certain signals between two samples or within a cycle, for example) Adaptable techniques can be used to auto-tune tune the starting element to the existing load conditions Phase Selection Fast and accurate digital measurement of phase voltages, currents and impedances enables robust and fast recognition of the type of fault Advanced techniques can be used to make the recognition more robust Zone Elements A number of diverse measuring algorithms are available for fast and accurate impedance estimation Zone characteristics can be shaped freely in a digital relay First zone trip can be accelerated by adaptive self-adjustment of the first zone depending on fault location and scale of the transient Zone Elements Sample Impedance Trajectory Digitally measured impedance moves on the impedance plane as the transient develops marking an impedance trajectory Measuring algorithms can be optimized to provide favorable trajectories under various system and fault conditions 5

Sample Impedance Trajectory Sample Impedance Trajectory Power swing and directional elements can apply sophisticated checkings in order to block the relay when needed, but without decrease of the relay eayse sensitivity s Digital Differential Relay Operating principle: : for internal faults, the differential current is substantially larger than the restraining current protected zone (transformer, busbar, line, etc.) D Digital Differential Relay Advantages Software compensation for the ratio mismatch, transformer vector group and CTs connections Adaptive bias for high sensitivity Fast measurement and trip of clear cases Sophisticated operating principles for inrush or saturation of CTs Functional improvement by integrating protection, control (tap changer) and monitoring functions (transformer, breakers, etc.) 6