DC Axial Fans. ebm-papst St. Georgen. Noise

Similar documents
DC Axial Fans. ebm-papst St. Georgen. Ball Bearings. Noise

DC axial compact fan

DB Motorized Impeller

DB Motorized Impeller

Product Data Sheet 8452/2 GHHP

Product Data Sheet RER225-63/18/2TDO- 406

DB Motorized Impeller

Product Data Sheet RER190-39/14/2TDMO

-1 ] temperature life [V]

Product Data Sheet RG160-28/18N/2TDPU-331

Product Data Sheet RER220-43/18/2TDMO

EC centrifugal fan. R3G175-AF25-02 backward curved, single inlet. Nominal data

EC centrifugal fan - RadiCal

Product Data Sheet 3254 J/2H3P

Product Data Sheet 3252J/2H3PU

Product Data Sheet 622/2HHP-021

EC centrifugal fan - RadiCal

175 mm 69 mm Specifications

NEW PRODUCT INFORMATION

92 38 mm. Reversible Flow Fan. 9RF type. Features. Common Specifications. Specifications. Reduces the required number of fans

NEW PRODUCT INFORMATION

Product Data Sheet 6314/2TDHP. The engineer's choice

Product Data Sheet 8214 J/2H4P. The engineer's choice

Product Data Sheet 8452/2HHP. The engineer's choice

EC centrifugal fan - RadiCal

EC centrifugal fan - RadiCal

9WL type. Rated current Rated input. Rated speed [min -1 ]

B1793 AC Blower Innovation in Motion

EC centrifugal fan - RadiCal

Product Data Sheet DV4112/2NP-201

Product Data Sheet 8214 J/2H4P

EC centrifugal fan - RadiCal

EC centrifugal fan - RadiCal

EC centrifugal fan - RadiCal

Product Data Sheet 6424/2HP-210

WL Product Range Performance Comparison

High Performance Blowers

AC centrifugal fan. R2E180-AS backward curved, single inlet. Nominal data

Cross Flow Fans. Additional Information. Cooling Fans. Introduction E-85 MF Series E-88 MFD Series E-92

n Measuring range ,02 N m to N m n Clockwise and counter-clockwise torque n Low linearity deviation of ± 0.05 % F.S.

Explanation of Nidec Fan Model Numbers

AC centrifugal fan. backward curved

EC centrifugal fan. backward curved, single inlet

4 / 24,5 2,6 / steel, black coated. clockwise, viewed from the front face. ø15,9 ø17-0,052 ø6-0,05 8,1 ±0,3 2, T

Analog amplifier RA. RE Edition: Replaces:

EC centrifugal fan. forward curved, dual inlet with housing (flange)

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

Specification For Approval

EC centrifugal fan. forward curved, dual inlet with housing (flange)

Specification For Approval

RoHS. High shaft load capacity. Shock / vibration resistant

EC centrifugal fan G3G250-GN backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

EC centrifugal fan. backward curved, single inlet

Automotive BL-DC Fans for Commercial Vehicles. Edition

EC centrifugal fan G3G200-GN backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

V: Very low speed, E: Extra low speed, L: Low speed, M: Middle speed, H: High speed, S: Super High speed, U: Ultra High speed, T: Top High speed

EC/AC axial fans - HyBlade Ø

Centrifugal Fan Product Range

D1238B12B9AP-00 D1238B24B9AS-00 D1238B24B9AP-00 D1238B48B9AS-00 D1238B48B9AP-00 D1238B12B8AP-00 D1238B24B8AS-00 D1238B48B8AS-00 D1238B48B8AP-00

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

PowerAmp Design. PowerAmp Design PAD112 HIGH VOLTAGE OPERATIONAL AMPLIFIER

EC centrifugal fan. forward-curved, dual-intake with housing (flange)

XXXX e. X d.. X X X a

Rotron ½ AXIMAX 1 Small Vaneaxial Fans

AC centrifugal fan - RadiCal

EC centrifugal fan. backward curved, single inlet

Tangential Fans - Basic principles. Expertise, performance, innovation

SPECIFICATION FOR APPROVAL

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

PowerAmp Design. PowerAmp Design PAD117A RAIL TO RAIL OPERATIONAL AMPLIFIER

SPECIFICATION FOR APPROVAL

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

Lexium integrated drives

Analog Amplifier RA. RE / /12 replaces: RE RE RE RE Technical Data Sheet

EC centrifugal fan. forward curved, dual inlet with housing (large flange)

EC centrifugal fan G3G200-GN backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

SPECIFICATION REDUNDANT POWER SUPPLY HOT-SWAPPABLE 370W+370W

Ametek, Inc. Rotron Technical Products Division. 100 East Erie St., Suite 200 Kent, Ohio User's Guide. Number Revision F

Brushless DC-Servomotors with integrated Encoder 4 Pole Technology

Standard Sendix 5000 / 5020 (shaft / hollow shaft) Push-Pull / RS422 / Open collector. Robust performance. Many variants

PowerAmp Design. PowerAmp Design PAD20 COMPACT HIGH VOLTAGE OP AMP

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

AC centrifugal fan. forward curved, dual inlet with housing (without flange)

TVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active

EC centrifugal fan. forward curved, dual inlet with housing (flange)

JUMO ecotrans Lf 03 Microprocessor Transmitter / Switching Device for conductivity or resistivity and temperature

AC diagonal compact fan

XXXX e. X d.. X X X a

2-02 Start voltage The voltage that enable to start the fan by sudden switch on.

Compact fans for AC and DC. version 2014

LED Driver Compact dimming

PKG-171-MBC25-PS-CBL System Diagram and Specifications

PP400B060-ND. H-Bridge POW-R-PAK IGBT Assembly 400 Amperes/600 Volts

Refrigerated Products Brochure. USA Edition

Positioning drives DC motor, brushless Absolute multiturn position detection, Profibus-DP

LAB 1 AN EXAMPLE MECHATRONIC SYSTEM: THE FURBY

Type Nominal voltage (V) Code HSV V

Options & Accessories

EC centrifugal fan. forward curved, single inlet with housing (flange)

Online data sheet DFS60A-TEPZ00S09 DFS60 INCREMENTAL ENCODERS

Transcription:

DC Axial Fans Series 4300, Type 4312 L 119 x 119 x 32 mm DC fans with electronically commutated external rotor motor. Fully integrated commutation electronics. With electronic protection against reverse polarity, blocking and overloading by PTC-resistor; partially impedance protected. Fan of fibreglass reinforced plastic. PBTP housing, PA impeller. Air exhaust over struts. Rotational direction CW looking at rotor. Optional Vario-Pro: Highly adaptable software configuration of the fan enables a tailor-made solution to the specific requirements of your applications. Electrical connection via leads AWG 22, TR 64. Stripped and tinned ends. Mass 220 g. Nominal Data Air Flow Air Flow Nominal Voltage Voltage Range Noise Sintec-Sleeve Bearings Ball Bearings Power Input Nominal Speed Temperature Range Service Life L 10 at 40 C at t max Curve Type m 3 /h CFM V DC V DC db(a) Bel / Watt min -1 C Hours Hours 4312 GL 95 55.9 12 6...15 30 4.3 1.2 1 550-20...+75 80 000 / 35 000 1 4312 L 95 55.9 12 6...15 30 4.3 1.2 1 550-20...+75 80 000 / 35 000 1 4312 GM 140 82.4 12 6...15 39 5.3 2.6 2 300-20...+75 70 000 / 30 000 2 4312 M 140 82.4 12 6...15 39 5.3 2.6 2 300-20...+75 70 000 / 30 000 2 4312 G 170 100.1 12 6...15 45 5.8 5.0 2 800-20...+75 62 500 / 27 500 3 4312 170 100.1 12 6...15 45 5.8 5.0 2 800-20...+75 62 500 / 27 500 3 4312-143 180 105.9 12 6...15 47 6.1 5.8 3 000-20...+75 57 500 / 25 000 4 4312-179 204 120.1 12 6...13.2 51 6.4 8.5 3 400-20...+75 47 500 / 20 000 5 4314 L 95 55.9 24 12...28 30 4.3 1.2 1 550-20...+75 80 000 / 35 000 1 4314 M 140 82.4 24 12...28 39 5.3 2.6 2 300-20...+75 70 000 / 30 000 2 4314 G 170 100.1 24 12...28 45 5.8 5.0 2 800-20...+75 62 500 / 27 500 3 4314 170 100.1 24 12...28 45 5.8 5.0 2 800-20...+75 62 500 / 27 500 3 4314-147 180 105.9 24 12...28 47 6.1 5.8 3 000-20...+75 57 500 / 25 000 4 4314-180 204 120.1 24 12...26.5 51 6.4 9.5 3 400-20...+75 45 000 / 20 000 5 4318 M 140 82.4 48 36...56 39 5.3 3.5 2 300-20...+75 70 000 / 30 000 2 4318 G 170 100.1 48 36...53 45 5.8 5.0 2 800-20...+75 62 500 / 27 500 3 4318 170 100.1 48 36...53 45 5.8 5.0 2 800-20...+75 62 500 / 27 500 3 Rotor protrusion max. 0.4 mm

/12 Speed-proportional rectangular pulse for external speed monitoring of fan motor 2 pulses per revolution TTL-compatible Integrated pull-up resistor Connection via separate lead The sensor signal also serves as a major comparison variable for setting and maintaining the desired speed for interactive or controlled cooling with one or more interconnected fans. Electrical connection Signal data U S Low I sink U S High I source Perm. sink current I sink max. Type V DC ma V DC ma ma All voltages measured to ground. 614 N/12 GM 0.4 1 2.5 5.5 1 1 618 N/12 N 0.4 1 2.5 5.5 1 1 8412 N/12 0.4 1 2.5 5.5 1 1 8412 N/12 H 0.4 1 2.5 5.5 1 1 8312 /12 0.4 1 2.5 5.5 1 1 8314 /12 0.4 1 2.5 5.5 1 1 8314 /12 H 0.4 1 2.5 5.5 1 1 8318 /12 0.4 1 2.5 5.5 1 1 8318 /12 HL 0.4 1 2.5 5.5 1 1 8318 /12 H 0.4 1 2.5 5.5 1 1 3318 /12 H 0.4 1 2.5 5.5 1 1 4412 F/12 GML 0.4 1 2.5 5.5 1 1 4412 F/12 GM 0.4 1 2.5 5.5 1 1 4414 F/12 0.4 1 2.5 5.5 1 1 4418 F/12 0.4 1 2.5 5.5 1 1 Signal symmetry [t 1,t 2 ] = 0.8 1.2 Signal frequency [F] = 2 x n/60 Hz 4312 /12 L 0.4 1 2.5 5.5 1 1 4312 /12 M 0.4 1 2.5 5.5 1 1 4314 /12 0.4 1 2.5 5.5 1 1 4318 /12 0.4 1 2.5 5.5 1 1 4212 /12 L 0.4 1 2.5 5.5 1 1 4212 /12 0.4 1 2.5 5.5 1 1 4212 /12 H 0.4 1 2.5 5.5 1 1 4214 /12 0.4 1 2.5 5.5 1 1 4214 /12 H 0.4 1 2.5 5.5 1 1 4218 /12 0.4 1 2.5 5.5 1 1 With these fan options, deviations in regard to temperature range, voltage range and power consumption are possible compared with standard fan data.

Available on request: Galvanically separated sensor and signal circuit Varying voltage potentials for power and logic circuit. Signal data U S Low I sink U S High I source Perm. sink current I sink max. Type V DC ma V DC ma ma 4218 /12 H 0.4 1 2.5 5.5 1 1 4182 N/12 X 0.4 1 2.5 5.5 1 1 5118 N/12 0.4 2 2.5 5.5 1 20 5214 N/2 H 0.4 1 2.5 5.5 1 1 7118 N/12 0.4 2 2.5 5.5 1 20 7214 N/12 0.4 2 2.5 5.5 1 20 6224 N/12 M 0.4 2 2.5 5.5 1 20 6248 N/12 0.4 2 2.5 5.5 1 20 6248 N/12 T 0.4 2 2.5 5.5 1 5 DV 6224 /12 0.4 2 4.5 5.25 2 12 DV 6248 /12 0.4 2 4.5 5.25 2 12 6424 /12 H 0.4 2 2.5 5.5 1 20 RG 125-19/12N/12 0.4 1 2.5 5.5 1 1 RG 125-19/14N/12 0.4 1 2.5 5.5 1 1 RER 125-19/12N/12 0.4 1 2.5 5.5 1 1 RG 160-28/12N/12 0.4 2 2.5 5.5 1 5 RG 160-28/18N/12 0.4 2 2.5 5.5 1 20 RER 160-28/12N/12 0.4 2 2.5 5.5 1 5 RER 160-28/18N/12 0.4 2 2.5 5.5 1 20 With these fan options, deviations in regard to temperature range, voltage range and power consumption are possible compared with standard fan data.

Alarm signal /17 Alarm signal for speed monitoring Signal output via open collector The fan emits a high continuous signal during trouble-free operation within the permissible voltage range Low signal when speed limit is not reached. After elimination of fault, the fan returns to its desired speed; the alarm signal reverts to high Alarm signal data voltage U A Low I sink = voltage U A High I source Alarm operating voltage U BA max. Max. permissible sink current Alarm delay time t 2 Speed limit n G Type V DC ma V DC ma V DC ma S min 1 8318/17 0.4 n < ng 2 60 n > ng 0 60 50 15 * 1500 ± 100 8318/17 H 0.4 n < ng 2 60 n > ng 0 60 50 15 * 1500 ± 100 3312/17 0.4 n < ng 2 60 n > ng 0 60 20 15 * 1500 ± 100 3318/17 H 0.4 n < ng 2 60 n > ng 0 60 20 15 * 1500 ± 100 4312/17 L 0.4 n < ng 2 60 n > ng 0 60 20 15 * 850 ± 100 4314/17 0.4 n < ng 2 60 n > ng 0 60 20 15 * 1150 ± 100 4318/17 M 0.4 n < ng 2 60 n > ng 0 60 20 15 * 1150 ± 100 4318/17 0.4 n < ng 2 60 n > ng 0 60 20 15 * 850 ± 100 With these fan specials, deviations as regards temperature range, voltage range and power consumption are possible compared with standard fans. * After switching on U B Electrical connection All voltages measured to ground. External load resistance R a from U A to U BA required. With s with external temperature sensor for controlling the motor speed, the NTC sensor is not included in the scope of delivery. Temperature sensor LZ 370, see Accessories. t 2 = Alarm signal suppression during start-up * n < speed limit n G by braking or blocking.

Available on request: With integrated signal latching for subsequent recognition of short-time faults Alarm circuit open collector or TTL Galvanically isolated for maximum device safety; Defects in the power circuit do not affect the alarm circuit. Alarm signaldata voltage U A Low I sink = voltage U A High I source = Alarm operating voltage U BA max. Max. permissible sink current Alarm delay time t 2 Speed limit n G Type V DC ma V DC ma V DC ma S min 1 4312/17 MV 0.4 n < ng 2 60 n > ng 0 60 20 15 * 1500 ± 100 4312/17 V 0.4 n < ng 2 60 n > ng 0 60 20 15 * 1500 ± 100 4314/17 V 0.4 n < ng 2 60 n > ng 0 60 20 15 * 1150 ± 100 4318/17 V 0.4 n < ng 2 60 n > ng 0 60 20 15 * 850 ± 100 5112 N/17 0.4 n < ng 2 60 n > ng 0 60 20 15 * 1250 ± 50 7114 N/17 0.4 n < ng 2 60 n > ng 0 60 15 15 * 1330 ± 60 7214 N/17 0.4 n < ng 2 60 n > ng 0 60 15 15 * 1330 ± 60 DV 6224/17 0.4 n < ng 2 60 28 n > ng 0 60 10 10 ± 4 * 1900 ± 100 RG 125-19/14N/17 0.4 n < ng 2 60 n > ng 0 60 20 15 * 1500 ± 100 With these fan specials, deviations as regards temperature range, voltage range and power consumption are possible compared with standard fans. * After switching on U B