Power supply voltage Output Timer function Features Model No Single-function with one input/output (two circuits)

Similar documents
Power supply voltage Output Timer function Features Model No Single-function with one input/output (two circuits)

Power supply voltage Output Timer function Features Model No Single-function with one input/output (two circuits)

Ordering Information. Stepping Relay Unit G9B. Model Number Legend

Ordering Information. Ratchet Relay G4Q. Plug-in Models. Model Number Legend

G7K. Latching Relay. Compact Mechanical Lock Latching Relays with Manual Buttons. Model Number Structure. Ordering Information

TL-W5MD1 2M *1 *3 TL-W5MD2 2M

G70R-SOC08 CSM_G70R-SOC08_DS_E_2_1

CSM_G7S-_-E_DS_E_7_1

MY-GS CSM_MY-GS_DS_E_2_1

Pre-wired Photomicrosensor with Amplifier and Cable EE-SPW321/421 Compact, Thin-profile Photomicrosensor with special amplifier.

MK CSM_MK_DS_E_2_2. Compact Power Relays. A Wide Variation of Octal Pin Power Relays. Model Number Structure

E3X-DRT21/SRT21/CIF11

Sensing method Appearance Sensing distance Operation mode Model Convergent-reflective (narrow vision field) 30 to 100 mm (variable)

DPDT+DPST-NO MM4KP-JD MM4XKP-JD

AC 24, 110, 120, 230, 240 DC 6, 12, 24, 48 LED indicator with test button G2R-1-SNI (S) G2R-2-SNI (S) Diode

Type Poles Contact configuration Rated voltage Model 3PST-NO, 3PST-NC 24 VDC

Type Poles Contact configuration Rated voltage Model G7S-4A2B 24 VDC 3PST-NO, 3PST-NC

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

2. Terminal Shape P: PCB terminals B: Screw terminals T: Quick-connect terminals (#250 terminal)

Type Sealing Poles Contact configuration Rated voltage Model. Type LED indicator Poles Rated voltage Model

E6F-CWZ5C (1000P/R) 2M

Alternate Operation Relay 61F-AN/-APN2

Model Number Structure

Ordering Information. Power Relay G2A. Model Number Legend Highly Reliable, 4-pole Miniature Relay Ideal for Sequence Control

Model Number Structure

Fluoro plastic housing for highest chemical and detergent resistance

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder

Sensing method Appearance Sensing distance Operation mode Model. Emitter E3S-2LE4 Through-beam *1. 2 m. 0.1 to 2 m. 300 mm. 2 m

E6B2-C. General-purpose Encoder with External Diameter of 40 mm. Incremental 40-mm-dia. Rotary Encoder. Ordering Information

Resolution (pulses/rotation) 100, 200, 300, 360, , 720, 800 1,000, 1,024, 1,200 1,500, 1,800, 2,000 2,048, 2,500, 3, , , 360, 500

Model Number Structure

* (110 VAC) in this catalog have been discontinued at the end of March L 2KM: Long-distance (for 2 km)

Non-Ferrous-Metal-Detecting Proximity Sensor (Separate Amplifier Type)

Phase-sequence Phase-loss Relay

Floatless Level Switch (Ultra High-sensitivity Type) 61F-UHS/-HSL

Resolution (divisions) Pre-wired Model E6F-AB3C 360P/R 2M *2 Pre-wired Connector E6F-AB3C-C 360P/R 2M *2 Model (2 m) NPN open collector BCD 360

Power Relays G7Z. Model Number Structure. Model Number Legend Relay with Auxiliary Contact Block. New Product Relay

Switch Mode Power Supply

Model Number Structure

Single-phase Current Relay

E8EB-N0C2B E8EB-N0B2B

Switch Mode Power Supply

Phase-sequence Phase-loss Relay

Sensing method Sensing distance Model

Model Number Structure

Reverse Protection Relay 2. Control Power Supply Voltage None: 200/220 VAC 380: 380/400 VAC 440: 440 VAC

Single-phase Current Relay

Standard model G2A-432A-US G2A-4321P-US. Arc barrier equipped model G2A-432AY-US ---

Single-phase Voltage Relay

Three-phase Undervoltage and Phase-sequence Phase-loss Relay

TL-W5MD1 2M *1 *3 TL-W5MD2 2M

Detection of Incorrectly Set Work Press Position Confirmation Detection of Bent Drills. Press D5C

Three-phase Asymmetry and Phase-sequence Phase-loss Relay

Name Model Specifications/Design ID Tag V700-D23P31 20 dia. t 2.7 mm Coin-shaped 256 bytes (with user area of 240 bytes)

Model Number Structure

22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection

Model Operation mode TL-W5MD1 2M *1 *2 TL-W5MD2 2M *2 NPN TL-W5MC1 2M PNP TL-W1R5MB1 2M --- PNP TL-W3MB1 2M *2 TL-W3MB2 2M *2

Solid-state Timer H3DE

Three-phase Asymmetry and Phase-sequence Phase-loss Relay

Relays with Forcibly Guided Contacts G7SA

E6F-CWZ5C (1000P/R) 2M

Resolution (pulses/rotation) 100, 200, 300, 360, , 720, 800 1,000, 1,024, 1,200 1,500, 1,800, 2,000 2,048, 2,500, 3, , , 360, 500

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

E3JM/E3JK. Two Models Contribute to Overall Cost Reduction. Built-in Power Supply Photoelectric Sensor. Ordering Information

Rated time Time setting range Time division 1 week 00:00 a.m. to 11:59 p.m. 1 min

Digital Panel Meter K3TE. Model Number Structure. Model Number Legend. Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input K3TE

20 Series Power Relays

256, 360, 720, 1,024. E6C3-AN1E 256P/R 1M Voltage output Binary VDC E6C3-AN2E 256P/R 1M

S8V-NF (Single-phase 250 V 3 A / 6 A Type)

NEW. Better Productivity by Standstill and Low-speed Monitoring

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

Solid-state Timer H3DS

G5Q. Ordering Information. Specifications. PCB Relay. Compact, High Isolation Relay J COIL RATINGS. 638 PCB Relay G5Q

12 V DC ±10 % 150 ma max. 130 ma max. 120 ma max.

Solid-state Twin Timer

For Momentary Operation

Solid-state Timer H3DE

ON-delay operation 8-pin round socket DPDT --- H3CA-8 H3CA-8 SPDT SPDT H3CA-8H H3CA-8H

D7F. Detects Changes in Machine. Vibration. Vibration Sensor with Linear Output or Manual Setting. Ordering Information

Contents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers

Remote Sensor Amplifier Terminal

MY-GS. Miniature Power Relays. Mechanical Indicators Added as a Standard Feature to Our Bestselling MY General-purpose Relays.

LED Displacement Sensor

Solid-state Timer H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A

Output configuration Resolution (pulses/rotation) Model. 10, 20, 30, 40, 50, 60, 100, 200, 300, 360, 400, 500, 600 E6C2-CWZ6C (resolution) 2M

Two-way Action Test Button (Models with Lockable Test Button) For Momentary Operation

onlinecomponents.com

V700-series. Electromagnetic Inductive RFID System. ID Tag. Antenna. Controller

DIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays. Model Number Structure

TL-W. Standard Flat Inductive Proximity Sensors. Ordering Information. Front and side facing surface IP67 DC 2-wire and DC 3-wire models

OMRON. H3DE - Standard Timer. H3DE-G - Star-Delta Timer. H3DE-F - Twin Timer. H3DE-H - Power OFF- Delay Timer

Model Number Structure

Ordering Information. Ratchet Relay G4Q. Model Number Legend

SPECIFICATIONS. For Reference. This specification sheet is for reference only, Please request it again if a specification for receipt is necessary.

Three-phase Asymmetry and Phase-sequence Phase-loss Relay K8AB-PA

Label Sensor. Ordering Information. Application Example E3S-CD68/CD63. Ideal for Detecting Labels on Bottles. E3S-CD68/CD63 Label Sensor

NPN PNP NPN PNP NPN PNP

G6C. Miniature High Capacity Relays with SPST-NO 10A and SPST-NO + SPST-NC 8A. Model Number Legend. Application Examples.

SLE30 Expert Series Slot Sensor

Two outputs: contact and non-contact

Transcription:

Controller CSM DS_E_7_1 Offers High-speed Input Response of 0.1 ms and Equipped with Built-in imer High-speed response of 0.1 ms. Ideal as a two-input Controller. Lineup includes the -BK with flip-flop functions convenient for level control, the -AKD/CKD/CCD with 24-V power supply, and the -DK/EK with one input/output -delay (two s) useful for load control and lamp display Power source for the can be supplied up to 200 ma. Ultra-slim body with 0-mm width. Multi-function model equipped with timer functions also available. Be sure to read Safety Precautions on page 7. For the most recent information on models that have been certified for safety standards, refer to your OMR website. Ordering Information Power supply voltage Output imer function Features Model No -DK Single-function with one input/output (two s) Yes -EK Relay No Single-function with two inputs/one output (AND/OR operation) -AK * 100 to 24AC No Flip-flop function with two inputs/one output -BK Yes -CK * Multi-function with two inputs/one output ransistor Yes -CC * No Single-function with two inputs/one output -AKD Relay 24 VDC Yes -CKD Multi-function with two inputs/one output ransistor Yes -CCD * Models compatible with s for PNP connections are also available. hese model numbers have the suffix B (e.g., -AKB) Differences from NPN Models Input signals Maximum applied voltage 8 to 12 V (5 ma min.) 0 to 4 V (2 ma max.) 12 V Note: -AK(B)/-CK(B)/-CC(B) models with UL certification are available. hese model numbers have the suffix US (e.g., -AK-US). 1

Ratings and Specifications ype wo inputs/ two outputs Singlefunction Single-function (with -delay) Single-function (AND/OR operation) Flip-flop function wo inputs/one output Multi-function * he timer will not operate in response to input signals received within 50 ms after the Controller power is turned. Single-function (AND/OR operation) Multi-function (24 VDC) Item Model -DK -EK -AK -BK -CK -CC -AKD -CKD -CCD Rated supply voltages 100 to 24AC ± 10% 50/60Hz 24 VDC ± 10% Power consumption 15 VA max. 2.5 VA max. (excluding power supply) Power supply for 12 VDC ± 10% (includes all variations), 200 ma max. (with short- protection) 24 VDC (supplied from power supply) Connected NPN transistor output (with sinking current of 18 ma min.) or contact output 0 to 4 V (5 ma min.) 8 to 12 V (2 ma max.) 8 to (2 ma max.) Input signals Short current Maximum applied voltage Input response time Output minimum pulse width Control output Life expectancy (relay output) Mechanical Electrical 11 ma YP (18 ma max.) 0.1 ms IN1 2 ms IN2 2 ms 0.1 ms 10 ms max. 0.5 ms max. 10 ms max. 0.5 ms max. Relay output SPS-NO 2 25AC, 2A (cosφ = 1) Relay output SPD (shared common) 25AC, A (cosφ = 1) 50,000,000 operations min. (switching frequency: 18,000 operations/h) 100,000 operations min. (switching frequency: 1,800 operations/h) NPN open collector output, DC, 100 ma (NO, NC) Residual voltage ()1.5 V max. Leakage current (): 0.1 ma max. --- Relay output SPD 25AC, A (cosφ = 1) 50,000,000 operations min. (switching frequency: 18,000 operations/h) 100,000 operations min. (switching frequency: 1,800 operations/h) NPN open collector output, DC, 100 ma (NO, NC) Residual voltage (): 1.5 V max. Leakage current (): 0.1 ma max. Output response time 10 ms max. 0.5 ms max. 10 ms max. 0.5 ms max. imer functions * --- Other functions Maximum allowable time of momentary power failure Ambient temperature range Ambient humidity range Noise immunity Dielectric strength Vibration (destruction) Weight -delay 1 to 10 s Signal input reverse 20 ms max. Signal input reverse AND/OR operating mode selection by wiring --- Signal input reverse Flip-flop function One-shot, -delay, and -delay 1 to 10 s Operating: 10 to +55 C, Storage: 25 to +65 C (with no icing) Operating/storage: 5% to 85% 0.01 to 0.1 s Signal input reverse Sync mode selection AND/OR operating mode selection Operating power supply: 1,50 (p-p) min.; pulse width: 100 ns, 1 μs; rise time: 1 ns Input/output: 1,20 (p-p) min.; pulse width: 100 ns, 1 μs; rise time: 1 ns 1,50AC min.(between power supply terminals and I/O terminals, and between non-current-carrying parts) 10 to 55 Hz, double-amplitude of 0.75 mm for 2 hours each of the X, Y, and Z directions Approx. 140 g --- Signal input reverse AND/OR operating mode selection by wiring One-shot, -delay, and -delay 1 to 10 s --- 0.01 to 0.1 s Signal input reverse Sync mode selection AND/OR operating mode selection Operating power supply: 48 (p-p) min.; pulse width: 100 ns, 1 μs; rise time: 1 ns Input/output: 1,00 (p-p) min.; pulse width: 100 ns, 1 μs; rise time: 1 ns 1,50AC min. (between power supply terminals and non-current-carrying parts) 2

Output Circuit Diagrams Note: Numbers in parentheses indicate terminal pin numbers. Relay Output Model Open Collector Model -AK/-AKD/ -CK/-CKD/-BK -DK/-EK -CC/-CCD NC NO Relay contact NC 25AC A NO NO NO OU2 OU1 NC DC 100 ma NO COM COM COM Input Circuit Diagrams Note: Numbers in parentheses indicate terminal pin numbers. Voltage output sensor Open collector output sensor R +12 V * OU 10 to 18 ma +12 V * (7), (10) IN (8), (11) (9), (12) +12 V * +12 V * 820 Ω 10 to 820 Ω OU 18 ma IN Note: erminals (7) and (10), and (9) and (12) are connected internally. * -AKD/-CKD/-CCD: +24 V * -AKD/-CKD/-CCD: +24 V Connections Connection Methods -AK -AKD -CK -CKD -CC -CCD -BK -DK/-EK +24V IN 1 0V +24V IN 1 0V +24V IN 1 0V +24V IN 2 0V +24V IN 2 0V +24V IN 2 0V POWER OU1 OU2 -AK SENSOR CROLLER :A 250VAC -AKD SENSOR CROLLER SOURCE:24VDC±10% 8.0VA :A 250VAC -CK SENSOR CROLLER :A 250VAC -CKD SENSOR CROLLER SOURCE:24VDC±10% 8.0VA :A 250VAC -CC SENSOR CROLLER :100mA 0VDC -CCD SENSOR CROLLER SOURCE:24VDC±10% 8.0VA :100mA 0VDC -BK SENSOR CROLLER :A 250VAC -EK SENSOR CROLLER :2A 250VAC COM OU1 OU2 1 2 24VDC 1 2 24VDC 1 2 24VDC OMR Corpration MADE IN JAPAN OMR Corpration MADE IN JAPAN OMR Corpration MADE IN JAPAN OMR Corpration MADE IN JAPAN OMR Corpration MADE IN JAPAN OMR Corpration MADE IN JAPAN OMR Corpration MADE IN JAPAN OMR Corpration MADE IN JAPAN, (2): Power supply terminals (): terminal Ground with a ground resistance of 100 Ω max. in locations subject to excessive noise. to : Output terminals (7), (10): Power supply terminals for -AKD/-CKD/-CCD s (+24 V), and other models (+12 V) (9), (12): Power supply terminals for the () (8), (11): Output terminals for the Connect the output lines.

Connections wo-wire s (NPN Models) Wired OR ransistor Output 1 Brown Blue +12 V (7), (10) IN (8), (11) (9), (12) +12 V (7), (10) IN (8), (11) (9), (12) Note: Numbers in parentheses indicate terminal pin numbers. Contact Output s he has a high-speed input response of 0.1 ms, which may cause contact output models (relay output, micro-switches, etc.) to receive unnecessary input from contact bounce and chattering. Example of Unconnectable Model ype Proximity Model L-GD, L-L100, etc. Details 12 V Output 2 ma max. Sink current of NPN output: 2 ma max. (s that cannot switch 18 ma or higher are unconnectable) 2 Note: Numbers in parentheses indicate terminal pin numbers. Wired OR for Object Detected Signals (e.g., Proximity s with NO Outputs) he input would be an OR of object detected signals using a wired OR of s that turn the output transistor when an object is detected. he s input signal selector switch can be set to reverse this operation and produce an input that would be an AND of object not detected signals. Wired OR for Object Not Detected Signals (e.g., Proximity s with NC Outputs) he input would be an OR of object not detected signals using a wired OR of s that turn the output transistor when an object is not detected. he s input signal selector switch can be set to reverse this operation and produce an input that would be an AND of object detected signals. Load Connection Connecting Loads to Collector Side Connecting Loads to Emitter Side NC Load NC NO COM Load DC NO COM Load DC Note: 1. Numbers in parentheses indicate terminal numbers. 2. Connect either the NC or NO terminals for the Emitter common. he solid line indicates the NC terminal and the broken line indicates the NO terminal. 4

Nomenclature -AK/-AKD -CK/-CKD/-CC/-CCD -BK -DK -EK (2) () (2) () (7) (8) (9) (10) (11) (12) (2) () (12) (9) (10) No. Name Functions POWER indicator (green) Lights when the operating power is turned and the power supply is output. Not lit when the operating power is turned, or the power supply is short ed (between the +12-V or +24-V terminal and 0-V terminal). (2) IN1 indicator (red) Lights when the output from the connected to IN1 is received by IN1 as an input. () IN2 indicator (red) Lights when the output from the connected to IN2 is received by IN2 as an input. OU indicator (red) Lights when the output turns. IN1 input signal selector switch NORM: Input as a signal when the s output transistor (or contact output) is. IN2 input signal selector switch INV: Input as a signal when the s output transistor (or contact output) is. (7) (8) MODE (AND/OR operation selector switch) SYNC (synchronous mode selector switch) (his switch is enabled only when the AND/OR operation selector is set to AND.) (9) IMER switch (10) (11) (12) RANGE (imer timing selector switch) IMER MODE (imer operation mode switch) IME ADJ. (imer setting adjuster) * Be sure to set the one-shot timer. AND: he output is turned when IN1 and IN2 input signals are both. OR: he output is turned when either IN1 or IN2 input signal is. : he output is turned while both IN1 and IN2 input signals are. : If the input signal of IN2 is turned (at the rising edge) while the IN1 input signal is, the output is turned.* urns timer operation /. : imer enabled : imer disabled Changes the range for the timer setting time. -CK/-EK 1 s: Setting time is in range from 0.1 to 1s. 10 s: Setting time is in range from 1 to 10s. -CC 0.1 s: Setting time is in range from 0.01 to 0.1s. 1 s: Setting time is in range from 0.1 to 1s. O. S: One-shot timer. D: -delay timer. D: -delay timer Setting time can be adjusted with the provided screwdriver. he adjuster rotates 190. 5

Operation Basic Operation -AK@: Basic Operation One IN1 (NORM) -CK@/-CC@: imer Operation (AND) IN1 IN2 [IN2 (INV)] No connection Output Note: When connecting only one, be sure to set the input selector switch for the unconnected to INV. wo s (AND Operation) IN1 (NORM) IN2 (NORM) Output (AND) wo s (OR Operation) 1 2 IN1 IN2 NORM INV -AK/-AKD Brown Black Blue IN1 IN2 NORM NORM -AK/-AKD (See note 1.) Output (OR) (See note 2.) Output (AND) (See note.) One-shot output (AND) (See note 4.) -delay output (AND) (See note 5.) -delay output (AND) Note: 1. IN1 and IN2 send OR outputs. 2. IN1 and IN2 send AND outputs.. IN1 and IN2 send AND outputs for seconds from the rising edge. 4. IN1 and IN2 send AND outputs after a delay of seconds from the rising edge. 5. IN1 and IN2 send AND outputs for seconds from the falling edge. When only one is connected to the -CK@ and -CC@, always set the AND/OR selector switch to MODE OR. AND OR 1 2 (IN1: Wired OR) Output (OR) Note: When two s are wired OR and then receive input (IN1 or IN2), OR operation is possible. -BK: Flip-flop Operation Output Note: ts 2ms, tr 2ms Input 1 (IN1) takes priority when both inputs 1 and 2 are received at the same time. 1 2 -AK@ default settings: IN1 NORM, IN2 INV. If AND operation is used, set IN2 to NORM. IN1 (NORM) IN2 (NORM) ts tr 1 2 IN1 NORM IN2 INV -AK/-AKD Brown Black Blue IN1 IN2 NORM NORM -BK -DK/-EK: Basic Operation wo Input Signals Output Independently he -EK is equipped with an -delay imer. 1 (IN1) OU1 2 (IN2) OU2 1 2 -DK/-EK: One with wo Outputs erminals (8) and (11) are short-ed. 1 OU1 OU2 Brown Black Blue -DK IMER1 IMER2 -EK Note: 1. he time chart above shows the operation for an -EK when the timer 1 switch is and the timer 2 switch is. 2. erminals (8) and (11) are short-ed, and the current from the to the is 18 2 = 6 ma max. (YP 22 ma). 6

Safety Precautions Refer to Warranty and Limitations of Liability. his product is not designed or rated for ensuring safety of persons either directly or indirectly. Do not use it for such purposes. Be sure to connect the power supply to the power supply terminals correctly. Use a power supply with a voltage range of 100 to 24AC ± 10%. Do not use the product in atmospheres or environments that exceed product ratings. Wiring Ground is a ground terminal. Ground this terminal at a ground resistance of 100 Ω max. when installing in locations subject to excessive noise, or if the malfunctions. Do not share a ground line with other devices, or connect it to a structural beam of a building. Doing so will have the opposite effect, and may adversely affect the. Ground resistance of 100 Ω WARNING Precautions for Safe Use Precautions for Correct Use Other device Storing in a Protective Case ake measures to provide adequate heat dissipation. Otherwise, heat radiation from the body of the may cause the insides of protective casing to heat up. -AKD/-CKD/-CCD Do not connect a load of 1 A min. to models for which the power supply inputs are to be used as is for the power supply outputs. Connecting a load of 1 A min. to the s power supply outputs will cause the fuse in the case to break. erminals (7), (10) 24 V erminals (9), (12) Other device I < 1 A Load Output Connect a surge suppressor or diode in parallel to the load if an inductive load or other electrical part that generates noise is connected to the output. Connect the cathode side of the diode to the side of the power supply. Relay contact output Relay contact output Open collector output Output Relay Contact (Not Including -CC/-CCD/-DK/-EK) When using a load (e.g., contactor or valve) that generates an arc when the is broken, the NC (NO) contact may turn before the NO (NC) contact has opened (turned ). When using both NO and NC outputs at the same time, incorporate an arc suppressor (use the CR method, varistor, or other countermeasure). Mounting ightening orque Using the provided M.5 screws, tighten the terminal block to a torque of 0.59 N m max. For direct mounting, use M4 screws, and tighten them to a torque of 0.78 N m max. Side-by-side Mounting When two or more are mounted side by side, be sure to provide a minimum distance of 10 mm between them. Note: Use the PFP-M End Plate for a space of 10 mm. L Surge suppressor L Diode AC power supply Surge suppressor Resistance: 50 Ω Capacitor: 0.4 μf Voltage: 20 DC power supply Diode 10 mm If side-by-side mounting is unavoidable, refer to the following load derating curve. Peak reverse breakdown voltage is at least three times the load voltage. Average rectified current: 1 A End Plate (PFP-M) DIN rack Load current (ma) 200 100 Range in which side-by-side mounting is possible 0 10 20 25 0 40 50 55 60 Ambient temperature ( C) 7

Always lay the input lines, output lines, and the power line separately. Otherwise, malfunction due to noise may occur. Output lines (OU, 100 to 24AC) Input lines (IN, IN2, +12 V, ) he power line, through which a large current flows (e.g., to drive a motor) should be wired at least 200 mm away from the. Provide a distance of 200 mm min. Power lines Removing the erminal Block Cover Provide a distance of 200 mm min. Cover 1. Confirm that the power supply is turned. 2. Insert your fingers here and lift up in the direction of the arrow. Dimensions (Unit: mm) 7 * erminal block screws: M.5 Mounting Holes (direct mounting) 75 (no cover) wo M4 (or 4.-dia.) holes 5. 80 72±0. 0 2.5 78 51.5 (DIN rack mounting is also possible.) Cat. No. E846-E1-0 In the interest of product improvement, specifications are subject to change without notice. 8

erms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMR representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMR MAKES NO WARRANY OR REPRESENAI, EXPRESS OR IMPLIED, ABOU N-INFRINGEMEN, MERCHANABILIY OR FINESS FOR A PARICULAR PURPOSE OF HE PRODUCS. BUYER ACKNOWLEDGES HA I ALE HAS DEERMINED HA HE PRODUCS WILL SUIABLY MEE HE REQUIREMENS OF HEIR INENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron s sole obligation hereunder shall be, at Omron s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron s analysis confirms that the Products were properly handled, stored, installed and tained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, s, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMR COMPANIES SHALL NO BE LIABLE FOR SPECIAL, INDIREC, INCIDENAL, OR CSEQUENIAL DAMAGES, LOSS OF PROFIS OR PRODUCI OR COMMERCIAL LOSS IN ANY WAY CNECED WIH HE PRODUCS, WHEHER SUCH CLAIM IS BASED IN CRAC, WARRANY, NEGLIGENCE OR SRIC LIABILIY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer s application or use of the Product. At Buyer s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. his information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE HE PRODUC FOR AN APPLICAI INVOLVING SERIOUS RISK O LIFE OR PROPERY OR IN LARGE QUANIIES WIHOU ENSURING HA HE SYSEM AS A WHOLE HAS BEEN DESIGNED O ADDRESS HE RISKS, AND HA HE OMR PRODUC(S) IS PROPERLY RAED AND INSALLED FOR HE INENDED USE WIHIN HE OVERALL EQUIPMEN OR SYSEM. Programmable Products. Omron Companies shall not be responsible for the user s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. OMR Corporation Industrial Automation Company http://www.ia.omron.com/ 2016.9 In the interest of product improvement, specifications are subject to change without notice. (c)copyright OMR Corporation 2016 All Right Reserved.