Straight Isolation - Plug In (171 Series)

Similar documents
Straight Isolation - Hard Wired (169 Series)

2.2 American National Standards Institute Corporation and its applicable standards C39.1, C80.1, C89, C84.1.

LIFE LINE PRODUCT SPECIFICATION FOR A 1 TO 3 KVA, SINGLE PHASE, POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING

Power Processor - Series 700F 10KVA to 150KVA

Power-Sure 700. Technical Data TD158001EN. Contents

POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS

MAJORSINE Power Inverter

Amveco Toroidal Solutions. Acme Electric s class leading toroidal magnetics is the perfect solution for the most challenging applications.

PIRANHA 3 (3-phase, Power Conditioning Voltage Regulator)

PRODUCT SPECIFICATION FOR A 15 AND 75 kva, THREE PHASE MODULAR POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING (Varian)

StatiVolt. Inverter UPS Systems. Features. Contents

8101 SPECIFICATION SHEET

Power Conditioners product guide

TOSHIBA International Corp

These true online inverters integrate pulse width modulation (PWM) control combined with high frequency IGBT power transistors.

USER'S MANUAL DMR-6700

General Description & Features Selection Charts Definition of Terms... 42

Please use the Q & A utility to ask us any questions concerning the material being presented.

SAGA PRO SERIES STEREO POWER AMPLIFIER OPERATION MANUAL

These true on-line inverters incorporate pulse width modulation (PWM) control combined with high frequency igbt power transistors.

Technical Data Sheet. Uninterruptible Power Supply On-line VH Series UPS. Critical Power UL / 208V

ULTRA-K Series 600K - he

POWER QUALITY PRODUCTS FOR NON-LINEAR LOADS

Drives 101 Lesson 5. Power Input Terminology for a VFD

LED Driver. CertaDrive 18W 0.39A 46V V CI018C039V046FNN1M. Specifications. Enclosure. Wiring Diagram. Input and output use lead- wires.

VGM Series. 100 & 60 W, Efficient, CV Class 2 LED Drivers for Signage Applications ORDERING INFORMATION

Comm Series DC Power Supplies Radio Base Station Covers Battery Chargers DC UPS Backup Systems

USER MANUAL GOLDMUND MIMESIS 29M Millennium Edition Power Amplifier

1. All electrical switches and outlets used shall be equal to Hubbell heavy duty, specification grade or equivalent quality.

75 kva Isolation Transformer - 480V Delta Primary - 208V Delta Secondary - NEMA 3R

APQline Active Harmonic Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

Resilient 3000 EP3000AC48IN Rectifier 3000W Output at 48 58Vdc

VIM Series. 90 & 60 W, Efficient, CV Class 2 LED Drivers ORDERING INFORMATION

Industrial Areamaster Generation 2 HL LED Luminaire Floodlight for Ordinary Locations

User's Guide. AC Circuit Load Tester. Model CT70

5 kva Isolation Transformer - 115V Primary Voltage - 230V Secondary Voltage - Single Phase - NEMA 3R

7.5 kva Isolation Transformer - 460V Primary - 230V Secondary - NEMA 3R - Single Phase - 50/60 Hz

HPS Universal BUCK-BOOST TRANSFORMERS

Dry Type Transformers Full Line Catalog. jeffersonelectric.com

Max. Input Power (W) Input Current (Arms) / 100 <12% Dimming. 0-10V Analog Class 2 Wiring Only. Enclosure

and cured to reduce hot spots and seal out moisture. The assembly shall be installed on vibration-absorbing pads.

BUCK-BOOST TRANSFORMERS

MODEL 3810/2 Line Impedance Stabilization Network

500 kva Isolation Transformer - 480V Delta Primary - 400Y/231 Wye Secondary - NEMA 3R

15 kva Isolation Transformer - Single Phase - 208V Primary - 120/240V Secondary - NEMA 3R

75 kva Isolation Transformer V Delta Primary Voltage - 480Y/277 Secondary Voltage - NEMA 3R

Brown University Revised 2/1/2006 Facilities Design & Construction Requirements SECTION 16461C - DRY TYPE TRANSFORMERS

TOA PROFESSIONAL POWER AMP

ENCOUNTER AMPLIFIER MANUAL EN-1502 EN-3001 EN-3004

SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5

LED Driver. CertaDrive. 41W 0.87A 46V 0-10V (5% dim) V CI041C087V046CNN1. Specifications. Enclosure. Wiring Diagram

SPECIFICATION SWITCHING POWER SUPPLY SINGLE POWER 250W BEST POWER SOLUTIONS, INC. 9F, NO.196-7, SEC.3, TA-TUNG RD SHI CHIH, TAIPEI, TAIWAN, R.O.C.

SureTest Model ST-1THD & ST-1THDC Instructions

Instruction Kit MIXER AMPLIFIER GT 60C GT 125C. GROMMES-PRECISION SINCE-46

SPECIFICATION SWITCHING POWER SUPPLY BPS-300SP/2U 6-OUTPUT WITH ACTIVE PFC FUNCTION SINGLE POWER 300W BEST POWER SOLUTIONS, INC.

Power Quality. Answering Today s Power Challenges. Why Your Existing Transformer May Be Inadequate. How Harmonics Affect Transformers

Baymaster HL LED Luminaire High Bay for Hazardous Locations

.2 Section Waste Management and Disposal..4 Section Electrical General Requirements.

SPECIFICATION REDUNDANT POWER SUPPLY HOT-SWAPPABLE 370W+370W

Utility Systems Technologies, Inc. Sag Fighter. Deep Voltage Sag Protection:

SureTest Circuit Analyzers

Compliant to DOE 10, CFR Part 431 (effective as of January 1 st, 2016)

10 kva Transformer - 480V Primary Voltage - 208V Secondary Voltage - Single Phase - NEMA 3R

Bridgeport Magnetics Design Guide

Power Quality Solutions

Classic Series Public Address Amplifiers C10 & C20 Models

Thump18S. 1200W 18-Inch Powered Subwoofer

SWF DV/DT Solutions Sinewave Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

Baymaster LED Luminaire High Bay for Hazardous Locations

M-300 Mono power amplifier User s guide

DOBLE F6150e TECHNICAL SPECIFICATIONS

Harmonic Filters for Single Phase Equipment

Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned

Liebert Datawave GUIDE SPECIFICATIONS kva Magnetic Synthesizer Power Conditioning System

ALLNIC AUDIO L 1500 LINE STAGE PREAMPLIFIER

SECTION COMMUNICATIONS ELECTRICAL POWER DISTRIBUTION

21R14A Receiver 14 Control/1 Alarm/1 Safety relays 120 VAC Power Supply

FEATURES OPTIONAL FEATURES

Sb180. connected using the other connector. Care must be taken not to abuse the amplifier by connecting impedances which are too low.

Liebert Datawave. GUIDE SPECIFICATIONS kva Magnetic Synthesizer Power Conditioning System 1.0 GENERAL

Dry Type Distribution Transformers NON-LINEAR TRANSFORMER PRESENTATION

5G350 Nominal 33W 5G530 Nominal 48W 5G700 Nominal 64W 5G105 Nominal 97W 5G140 Nominal 126W K K. 1 DM or HL only. Cannot be combined.

RADIANT LED AREA LIGHTING

S10N06P02P 2KVA 1PH 120/240V 16/32V Buck Boost Transformer. Descriptions

MODEL 302IQ (1991-MSRP $149.00)

A Clamp W/TRMS

MAX Series Bass Amplifiers

Emotiva BasX A300 Stereo Power Amplifier

CONTENTS USER S GUIDE 1 CONTENTS 2 INTRODUCTION 3 HOW TO USE THIS MANUAL 3 APPLICATIONS 4 AC POWER REQUIREMENTS 4 AC POWER 4

1.5 kva Single Phase Transformer - 120V Primary Voltage - 277V Secondary Voltage - NEMA 3R

2.1. Product Description

Fan-On-Demand operates only when needed reducing noise, power consumption, and the amount of airborne contaminants pulled through the machine.

LED Driver. Xitanium. 300W V A Programmable Specifications. Enclosure. Wiring Diagram

Energy Efficient Distribution Transformers

Alternating Current Power

Autoranging Multimeter Extech EX503

POWERED MIXER DIGITAL ECHO EFFECT ECHO LEVEL ECHO LEVEL ECHO LEVEL ECHO LEVEL ECHO VOL REPEAT MPM CHANNEL POWERED MIXER OWNER S MANUAL

MVCT. Megger VT & CT Analyzer. MVCT Megger VT & CT Analyzer

Boulder W Class A Stereo Power Amplifier

80 kva Isolation Transformer - 480V AC Primary - 20V AC Secondary - NEMA 3R - Single Phase

Transcription:

Straight Isolation - Plug In (171 Series) LINE ISOLATION PLUG & RECEPTACLE TRANSFORMERS (115V to 115V) Primary 115C, 50/60 Hz., Secondary 115C Electrostatic shield between primary & secondary. Hi-pot tested to 2 KV RMS. Circuit breaker in primary. Standard 3-wire, grounded plug & receptacle. Input (primary) connected to 5 foot long cord & standard North American plug (NEMA 5-15P). Output (secondary) connected to 1 foot long 3-wire, standard North American grounded receptacle (NEMA 5-15R). North American Mark of Safety - C UL & UL listed (File #E211544) Primary 3-wire plug Secondary 3-wire receptacle Part Wt. No. A B C D E Lbs. 171A 100 3.80 5.06 4.68 3.00 3.38 6.5 171B 200 3.80 5.56 4.68 3.00 3.88 8 171C 300 3.80 6.06 4.68 3.00 4.38 11 171E 500 3.80 7.06 4.68 3.00 5.38 14 171F 750 4.40 8.70 5.39 3.50 6.78 30 171G 1000 5.28 7.75 6.38 4.25 4.38 34.5 Cheektowaga, NY (716) 630-7030 58

Toroidal Straight Isolation - Plug In (178 & 240 Series) Toroidal Isolation Plug In (120V to 120V) Primary 120C, 50/60 Hz., Secondary 120C. Toroidal transformer for high isolation, low noise, light weight, cool operation and low profile. World wide applications, 50 or 60 Hz. operation, step down (120C to 120 C). Standard 3-wire, grounded plug (for use with adaptors for proper grounding). standard North American plug (NEMA 5-15P). Output (secondary) connected to two standard 3 wire grounded receptacles (NEMA 5-15R). Features include ventilated black steel case, rocker lighted on-off switch & circuit breaker protected output. North American Mark of Safety - C UL & UL listed (File #E211544). Remember - These units do NOT convert line frequency. Part No. # of Outlets 178CT 250 2 8.25 6.00 4.00 178DT 500 2 9.00 6.00 4.00 178ET 750 2 10.25 7.50 5.00 178FT 1000 2 10.25 7.50 5.00 178GT 1500 2 12.50 9.00 5.00 Toroidal Isolation Plug In (240V to 240V) Primary 240C, 50/60 Hz., Secondary 240C. Toroidal transformer for high isolation, low noise, light weight, cool operation and low profile. World wide applications, 50 or 60 Hz. operation, step down (240C to 240C). Standard 3-wire, grounded plug (for use with adaptors for proper grounding). standard North American plug (NEMA 6-15P). Output (secondary) connected to a standard 3 wire grounded duplex receptacle (NEMA 6-15R). Features include ventilated black steel case, rocker lighted on-off switch & circuit breaker protected output. North American Mark of Safety - C UL & UL listed (File #E211544). Remember - These units do NOT convert line frequency. Part No. # of Outlets 240CT 250 2 8.25 6.00 4.00 240DT 500 2 9.00 6.00 4.00 240ET 750 2 10.25 7.50 5.00 240FT 1000 2 10.25 7.50 5.00 240GT 1500 2 12.50 9.00 5.00 59 Cheektowaga, NY (716) 630-7030

Straight Isolation - Constant Voltage - Plug In (CV Series) Constant Voltage A.C. Regulator - Plug In (120 V to 120V) AC regulating - protects against both brownouts & over voltage conditions. Protects against any power problem other than a blackout. Will operate through a 3 millisecond (minimum) blackout. Long life - ferroresonant design - no moving parts. Ferroresonant design also filters out surges, line harmonics, and RF noise. Input 120C (+10 % to -25 %), 60 Hz Output 120C (+/- 3 %). Noise Isolation (RF) of 120 db common mode, 60 db normal mode. Spike attenuation: 250:1 minimum. Sine wave output - total harmonic distortion (THD): 3 % Units also include a 2nd stage of high frequency filtering on the output - a Hammond Mfg. exclusive. Operating temperature range of -40 degrees C to +40 degrees C. Standard 3-wire, grounded plug & receptacle. Front panel lighted power switch. Input (primary) connected to an extra long 15 foot, heavy duty 14/3 SJTW cord for extreme temperature ranges. Integral molded, standard North American plug (NEMA 5-15P). Output (secondary) connected to a rear mounted, standard North American, grounded receptacle (NEMA 5-15R) - quantity depends on power capacity of unit (see table below). Rugged two piece ventilated steel enclosure. Finished in a grey/beige color, textured powder paint with rubber feet installed. NOTE 1: Due to the nature of ferroresonant designs - these units do produce audible noise. We have reduced this through careful design, but these units are NOT usable in an office environment. NOTE 2: These units provide complete isolation from the source voltage. In other words, the "neutral" output wire has no connection to ground, this is a UL requirement for this type of device. Therefore plug-in circuit testers & line "polarity" testing devices will NOT function on the output as it is completely isolated. North American Mark of Safety: C UL & UL listed (File #E211544). Part No. Number of Wt. Amps Rear Outlets Height Width Depth Lbs. (RMS) CV120300 300 2.5 2 7.00 7.13 12.30 25.3 CV120600 600 5 4 9.00 10.13 19.50 48 CV1201200 1200 10 4 9.00 10.13 19.50 74 CV1201800 1800 15 6 12.00 12.13 20.50 95 Cheektowaga, NY (716) 630-7030 60

Toroidal Isolation - Step Up - Plug In (298 Series) LINE ISOLATION STEP UP - PLUG IN (120V to 240V) Primary 120C, 50/60 Hz., Secondary 240C. Toroidal transformer for high isolation, low noise, light weight, cool operation and low profile. World wide applications, 50 or 60 Hz. operation, step UP (120C to 240 C). Standard 3-wire, grounded plug (for use with adaptors for proper grounding). standard North American plug (NEMA 5-15P). Output (secondary) connected to a standard N. American duplex - 3 wire grounded receptacles (NEMA 6-15R). Features include ventilated black steel case, rocker lighted on-off switch & circuit breaker protected output. North American Mark of Safety - C UL & UL listed (File #E211544).. Part No. # of Outlets 298CT 250 2 8.25 6.00 4.00 298DT 500 2 9.00 6.00 4.00 298ET 750 2 10.25 7.50 5.00 298FT 1000 2 10.25 7.50 5.00 298GT 1500 2 12.50 9.00 5.00 61 Cheektowaga, NY (716) 630-7030

Isolation - Step Down - Plug In (172 & 289 Series) LINE ISOLATION - STEP DOWN PLUG-IN TRANSFORMERS (230V to 115V) Primary 230C, 50/60 Hz. Secondary 115C Circuit breaker in primary. Provides circuit isolation & steps down primary voltage. Hi-pot tested to 2 KV RMS. Electrostatic shield between primary & secondary. North American 250V, 3-wire grounded plug (NEMA 6-15P). Output (secondary) connected to a 1 foot long cord & standard North American 125V, 3-wire grounded receptacle (NEMA 5-15R). North American Mark of Safety - C UL & UL listed (File #E211544). Part Wt. No. A B C D E Lbs. 172A 100 3.80 5.06 4.68 3.00 3.38 6.5 172B 200 3.80 5.56 4.68 3.00 3.88 8.5 172D 500 3.80 7.06 4.68 3.00 5.38 18.5 172E 750 4.40 8.70 5.39 3.50 6.78 30.0 172F 1000 5.28 7.75 6.38 4.25 4.38 34.5 LINE ISOLATION - TOROIDAL STEP DOWN - PLUG IN (240V to 120V) Part No. # of Outlets 289CT 250 2 8.25 6.00 4.00 289DT 500 2 9.00 6.00 4.00 289ET 750 2 10.25 7.50 5.00 289FT 1000 2 10.25 7.50 5.00 289GT 1500 2 12.50 9.00 5.00 Primary 240C, 50/60 Hz., Secondary 120C. Toroidal transformer for high isolation, low noise, light weight, cool operation and low profile. World wide applications, 50 or 60 Hz. operation, step down (240C to 120 C). Standard 3-wire, grounded plug (for use with adaptors for proper grounding). standard 250V 2 pole, 3 wire - North American plug (NEMA 6-15P). Output (secondary) connected to two standard 125V, 3-wire grounded receptacles (NEMA 5-15R). Features include ventilated black steel case, rocker lighted on-off switch & circuit breaker protected output. North American Mark of Safety - C UL & UL listed (File #E211544) Cheektowaga, NY (716) 630-7030 62

Isolation - Step Down - Plug In (179 Series) LINE ISOLATION STEP DOWN - PLUG IN (115V to 95V) Primary 115C, 50/60 Hz., Secondary 95C. Electrostatic shield between primary & secondary. World wide applications, 50 or 60 Hz. operation, step down (115C to 95C). Designed mainly for Japanese equipment operating in North America. Perfect for operating "Classic" equipment that can not tolerate todays higher line voltages (ie..125c input will produce a stress free 105C output - at full load - PLUS - isolation and shielding). Standard 3-wire, grounded plug (can also be used with adaptors for proper grounding). Input (primary) connected to a 5 foot long cord and standard 3-wire, 125V North American plug (NEMA 5-15P). Output (secondary) connected to two standard 3-wire, 125V grounded receptacles (NEMA 5-15R). Features include ventilated black steel case, rocker lighted on-off switch & fuse protected output. Part No. # of Outlets 179C 250 2 6.00 6.75 4.75 179D 500 2 6.00 8.25 4.75 179E 750 2 7.00 8.25 5.38 179F 1000 2 7.00 9.75 5.38 179G 1500 2 8.50 9.00 6.75 Output 3-wire receptacle (2) Input 3-wire plug 63 Cheektowaga, NY (716) 630-7030