Electronic Preset Delivery System. AccuLoad II TM. Installation. The Most Trusted Name In Measurement

Similar documents
P2412 Converter. AccuLoad Preset Accessory. Installation. The Most Trusted Name in Measurement. Issue/Rev. 0.0 (10/99) Bulletin MN06117

Meter Pulse Tampering Alert

Smith Meter AccuLoad. Electronic Preset Delivery System. Tank Proving Guide. Bulletin MN Issue/Rev. 0.1 (7/10)

GP-UF/A. Smith Meter Universal F/A Converter. Specifications. Features. Applications. Specifications

MPU 200 Series B. Ultrasonic Gas Flowmeter. Specifications. Features. Principle of Operation

Model S50-D Density Sensor Specifications

Smith Meter AccuLoad III VLR Simulator for AccuLoad III. Installation / Operation Manual. Bulletin MN06116 Issue/Rev 0.3 (10/13)

Smith Meter Electronic Preset Delivery System AccuLoad III-S With ALS1 or ALD1 Firmware Specifications

Smith Meter AccuLoad III-N4

Smith Meter Electronic Preset Delivery System AccuLoad III- Split Architecture Specifications

Electronic Preset Delivery System Smith Meter microflow.net Liquid. Installation Manual. Bulletin MNFL001 Issue/Rev 0.3 (10/15)

Simple Sturdy Economical LABEL. Invest in Confidence. Weatherproof Quarter-turn Actuators EZ RANGE

Smith Meter microload.net

Electronic Preset Delivery System Smith Meter microload.net. Installation Manual. Bulletin MN06150 Issue/Rev 0.6 (8/15)

Literature Release Notification

Appendix B Experimental equipment and procedures

Simple Sturdy Economical LABEL. Invest in Confidence. Weatherproof Quarter-turn Actuators EZ RANGE

Simple Sturdy Economical LABEL. Invest in Confidence. Weatherproof Multi-turn Actuators ET RANGE

Process Control HPP-25

Meter, PD Series JB10-S6, S7

Smith Meter AccuLoad III

Princo MagneLevel Model LML

900 ControlEdge Remote Termination Panel (RTP) for:

ABB MEASUREMENT & ANALYTICS DATA SHEET. Ultrasonic level LST400 Open channel flow transmitter

MV1000 MEDIUM VOLTAGE AC DRIVE 175 HP TO 16,000 HP

Ocean Controls KT-5221 Modbus IO Module

Possible installation effects on density meter in a fast loop sampling system.

Industrial actuation made easy

Pacific Antenna - Easy TR Switch

Proline Promass F 300, 500

UltraFlo UFDD ULTRASONIC CLAMP-ON FLOW METER

Process Control Calibration Made Easy with Agilent U1401A

Digital conductivity transmitter

ION PRODUCTS. Sensor Testers

Sarasota CM200 Sarasota HME900 Density Converter Electronics

Pacific Antenna Easy TR Switch

Pacific Antenna Simple Keyer Kit

Compact Signal Calibrator

Process-Controller HPP-25

Maxim Integrated Products 1

RCM DIRECT READING FLOWMETER

DEMO MANUAL DC2172A. LTC7138 High Efficiency, High V IN, Step-Down Regulator. Description. Performance Summary

Frame through-beam sensors

HI 2204LT Loop Powered Level Weight Transmitter OPERATION AND INSTALLATION MANUAL

CMT211xA Schematic and PCB Layout Design Guideline

PC to Radio Audio and Key-line Interface

Hardware Guide. Control Made Simple. Model 401A Signal Generator

Coriolis Massflowmeter

SERIES 70 ELECTRIC ACTUATORS THE HIGH PERFORMANCE COMPANY BRAY SERIES 70 ELECTRIC ACTUATORS

LST400 Ultrasonic level / open channel flow transmitter

Installation and Maintenance Manual HQ Release: February HQ Proportional Control Unit (PCU-A)

Patton Robotics, LLC.

Ultrasonic level transmitter, non-contact

Vibration Transmitter

SERIES 70 ELECTRIC ACTUATORS

ULTRASONIC FLOW METER FT101

BATCHMATE 1500 Batch Control Computer Technical Bulletin

Fisher 4200 Series Electronic Position Transmitters

ULTRASONlC FlOWMETER SAMPLE BOOK. TYPE:LRF-3300S Concentrating on Flow Measurement

A Methodology for Efficient Verification of Subsea Multiphase Meters used in Fiscal Allocation

PulseJack 1x1 Tab-UP RJ45

August 2014 Rev FEATURES CC1. CC nf. RC k. Fig. 1: XRP76XX Evaluation Board Schematics

Sensors Q625A Remote Setpoint Module

Electromagnetic Flow Transmitter

PLUG N PLAY WATT DIGITAL FM TRANSMITTER. April, 2002 IM No

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

Mid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL

GC83 Digital Indicators & GC93 Digital Meter Relay

BOMBARDIER, INC./ESAB WELDING SYSTEMS Table of Content Section I Section II Section III 1. Welding System Features 2. Operating Instructions 1. SVI 45

12 Bit 1 GS/s Return-to-Zero DAC Evaluation Board

LVDS Flow Through Evaluation Boards. LVDS47/48EVK Revision 1.0

Fisher 646 Electro-Pneumatic Transducers

GEMINI PRESETTABLE DUAL RATE INDICATOR WITH RATIO (A/B)

BNC 75 OHM CONNECTOR PRODUCTS

Installation guide 971 SmartRadar LTi

Specification DataFile

Fisher 646 Electro Pneumatic Transducer

PCB layout guidelines for MOSFET gate driver

Maxim Integrated Products 1

Radio Control Installation and Operating Instructions System 4

TECHNICAL INFORMATION INTEGRATED PASSIVE COMPONENTS WHAT ARE THE REAL BENEFITS?

Level Limit Switch nivotester FTL 325 P

Ensemble RXTX 07_RX Opamps and Output

JU1 JU4, JU6 5. Maxim Integrated Products 1

Digital flow transmitter for continuous flow measurement

mokveld s mission being responsible in engineering valves

Resistance. Department of Physics & Astronomy Texas Christian University, Fort Worth, TX. April 23, 2013

PhD Inline Vortex. Performance Specifications Accuracy. Operating Specifications

LED Field Strength Indicator Kit

MODEL NC221 MOBILE TWO-TONE SEQUENTIAL DECODER INSTRUCTION MANUAL

Ten Tec DDS Board Assembly Procedure

LVDS Owner s Manual. A General Design Guide for National s Low Voltage Differential Signaling (LVDS) Products. Moving Info with LVDS

Troubleshooting Guide for Aquatrac Smart AS and Flex

ZLED7020KIT-D1 Demo Kit Description

Junior Digital circuit experiment board. Use for the experimentation of digital circuits both TTL IC and CMOS DC supply :

MOC3031M MOC3032M MOC3033M MOC3041M MOC3042M MOC3043M. Parameters Symbol Device Value Units TOTAL DEVICE Storage Temperature. T STG All -40 to +150 C

Proper Bias-T Usage to Avoid PPG Damage

Cross-Connect Interface

Maxim Integrated Products 1

*Requires component changes

Transcription:

Electronic Preset Delivery System AccuLoad II TM Issue/Rev. 0.8 (8/95) Installation Bulletin MN06037 The Most Trusted Name In Measurement

Section 1 - General J4 J5 J3, J6, J7 and J8 J1 J2 Figure 2 InterFace Board MN06037 Issue/Rev. 0.8 (8/95) 7

Section 1 - General Note: Dimensions - Inches to the nearest tenth (millimeteres to the nearest whole mm), each independently dimensioned from respective engineering drawings. Figure 4 AccuLoad II NEMA IV Dimensions MN06037 Issue/Rev. 0.8 (8/95) 9

Section I - General Notes: 1. If security switches are not used, these terminals should be tied to the incoming power line. 2. Jumper Positions shown for 120 or 240 operation. 3. Preset Position #1 - Red - DC connections 1 through 24, 43, and 44 - AC connections 73 and 74, 80 through 105 4. Preset Position #2 - Yellow - DC connections 45 and 46, 49 through 72 - AC connections 75 and 76, 106 through 131 5. Common to both Preset Positions - White - DC connections 25 through 42 - AC connections 77 through 79, 132 through 134 Figure 6 Terminal Block Layout - Graphics Panel MN06037 Issue/Rev. 0.8 (8/95) 11

Section 1 - General Printer Output Jumpers 1. After assembling QOPV kit to AccuLoad II, connect numbered wires from header (part of QOPV Board) to corresponding terminal points on AccuLoad II I/O Board. Figure 16 Quad OPV MN06037 Issue/Rev. 0.8 (8/95) 21

Section 1 - General for Remote Start on Position #2 for Remote Start on Position #1 1. Locate jumper locations J1 and J2 on the keypad board. 2. Mount shunt plugs as indicated above for both J1 and J2. (J1 - Preset Position #1 and J2 - Preset Position #2). 3. Wire remote start input to ac terminal 103 (Preset Position #1) and ac terminal 110 (Preset Position #2). 4. Program both Preset Positions for Remote Stop under Permissive Sense #1 in the 800 directory of the program. Figure 17 Remote Start 22 MN06037 Issue/Rev. 0.8 (8/95)

Section 1 - General 1. Locate jumper locations J8 and J9 on the computer board. 2. Mount shunt plugs as indicated above in lower two positions of both J8 and J9. (J8 - Preset Position #2 and J9 - Preset Position #1) 3. Wire remote stop input to ac terminal 104 ( Preset Position #1) and ac terminal 111 (Preset Position #2). 4. Program both Preset Positions for Remote Stop under Permissive Sense #2 in the 800 directory of the program. Figure 18 Remote Stop MN06037 Issue/Rev. 0.8 (8/95) 23

Section 4 - AccuLoad II-SEQ A D C B External Permissives Input #6 Input #4 Input #5 AccuLoad II Preset Position #2 75 110 111 Voltage Sense Voltage Sense Voltage Sense 76 112 114 115 124 126 128 130 119 121 Stop Relay Relay #1 Relay #2 Relay #3 Relay #4 Pump Relay #5 Upstream Downstream 118 116 117 125 127 129 131 120 122 N.C. N.O. N.C. 210 Valve Upstream Sol. Downstream Sol. R1 R2 AIJ-1 Sol. AIJ-2 Sol. AIJ-3 Sol. AIJ-4 Sol. Input #3 Input #1 Input #2 108 106 107 Voltage Sense Voltage Sense Voltage Sense 123 109 N.C. 113 N.C. A Temperature Probe (100 Ω) Red Red Black Black 2 5 6 3 4 1 PPS Transmitter N.C. N.C. 62 63 64 65 66 54 55 49 50 52 53 51 56 67 Shield -12V Meter Power Common Channel A Channel B 57 58 59 60 61 71 72 69 2 N.C. Load Printer N.C. N.C. +4 to 20 4-20 ma -4 to 20 Input 2 70 Densitometer +4 to 20 68 4-20 ma -4 to 20 Input 1 45 46 +24 Vdc 24V Return 1 Pressure Xducer Transducer Power B Note: 1. If external relay permissives are used in series with AccuLoad II relays, an RC network must be placed in parallel with the permissive to prevent a false turn on of the AccuLoad II relays. Recommended RC network = 0.1 uf capacitor and a 680 ohm resistor (Electrocube part number RG 2031-11). 2. Any device shown outside of the AccuLoad II housing is to be supplied by the customer. 3. Dotted connection lines indicate options. 4. For other meter transmitter connections, see Figure 33 for specific connections. Figure 38 AccuLoad II Wiring Schematic (Preset Position 2) MN06037 Issue/Rev. 0.8 (8/95) 53

Section 5 - Related Publications The following literature can be obtained from FMC Technologies Measurements Solutions, Inc. Literature Fulfillment at johno@gohrs.com or online at www.fmctechnologies.com/measurementsolutions. When requesting literature from Literature Fulfillment, please reference the appropriate brochure number and title. Valves Model 210 - Specifications... Bulletin SS03009 Model 210 - Installation/Operation...Bulletin MN03010 Model 215 - Specifications... Bulletin SS03010 Model 215 - Installation/Operation...Bulletin MN03006 Model 215 - Service...Bulletin MN03007 Parts List... Consult Parts Operation The specifications contained herein are subject to change without notice and any user of said specifications should verify from the manufacturer that the specifications are currently in effect. Otherwise, the manufacturer assumes no responsibility for the use of specifications which may have been changed and are no longer in effect. Headquarters: 1803 Gears Road, Houston, TX 77067 USA, Phone: 281/260-2190, Fax: 281/260-2191 Gas Measurement Products: Erie, PA USA Phone 814/898-5000 Thetford, England Phone (44) 1842-82-2900 Kongsberg, Norway Phone (47) 32/286-700 Buenos Aires, Argentina Phone 54 (11) 4312-4736 Integrated Measurement Systems: Corpus Christi, TX USA Phone 361/289-3400 Kongsberg, Norway Phone (47) 32/286-700 San Juan, Puerto Rico Phone 787/274-3760 United Arab Emirates, Dubai Phone 971 +4/331-3646 Visit our website at www.fmctechnologies.com Liquid Measurement Products: Erie, PA USA Phone 814/898-5000 Los Angeles, CA USA Phone 661/702-8660 Slough, England Phone (44) 1753-57-1515 Ellerbek, Germany Phone (49) 4101-3040 Barcelona, Spain Phone (34) 93/201-0989 Moscow, Russia Phone (7) 495/564-8705 Melbourne, Australia Phone (61) 3/9807-2818 Printed in U.S.A. 8/95 FMC Technologies Measurement Solutions, Inc. All rights reserved. MN06037 Issue/Rev. 0.8 (8/95) Beijing, China Phone (86) 10/6500-2251 Singapore Phone (65) 6861-3011 Chennai, India Phone (91) 44/450-4400