The universal input/output device is a DIN rail mounted device. It is connected to the EIB via a bus connecting terminal.

Similar documents
Time Switch, 2-channel, MDRC SW/S 2.5, GH Q R0001

Current Module, 3-channel, MDRC SM/S , GH Q R0111

For controlling 4 independent shutter or sunblind drives via ABB i-bus including the functions Up/Down, Step/Stop.

Shutter Actuator with Manual Operation, 4-fold, 230 V AC, MDRC JA/S M, GH Q R0111. ABB i-bus EIB / KNX

Product Manual. ABB i-bus EIB / KNX. Universal Interface US/U Intelligent Installation Systems

Installer manual inputs/outputs interface for led KNX

The room thermostat application module with 2-fold switch sensor is placed on a flush-mounted bus coupler.

Binary Inputs. Ref.-No. KNX universal binary input, 8-gang. ETS-product family: Series embodiment (SE-) device (2 units) Ref.-No.

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

animeo KNX/EIB 4 AC Motor Controller WM/DRM V AC

EIB/KNX Switch Actuators. User manual

Width (W): 44 mm. bus connecting and branching terminal External supply --- Inputs: Number: up to 2 (depending on parameterization: channel 1 to 2)

Rev ABB i-bus KNX 6151/11 U-500. Power and productivity for a better world TM

instabus EIB product documentation

Technical data: Instabus EIB supply Voltage: YY 6 x 0.6 mm; red: bus (+) / black: bus (-)

1. Function. Universal dimming actuator REG-K/2x230/ 300 W. Universal dimming actuator REG-K/230/ 500 W. Universal dimming actuator REG-K/230/ 1000 W

K-BUS Switch Actuator

Room thermostat solo, FM Type: 6124-xx

KNX manual 1-channel flush-mounted switch actuator SU 1

series dimmer actuators, DMG 2 S, Upgrade Module DME 2 S and Booster DMB 2

Product and Applications Description

USER MANUAL CU-DIN DIM 4-CH 1.5A KNX EC MA

animeo KNX 4 AC Motor Controller 31. March 2016 WM/DRM V AC

animeo KNX/EIB 4 DC/E Motor Controller WM V AC Installation manual

Instruction manual. art Installation manual

CU-DIN DIM 6-CH 0 10V KNX

ABB i-bus KNX Meter Interface Module, MDRC ZS/S 1.1. Product Manual. Intelligent Installations Systems ABB

gesis EIB V Manual Installation system for European Installation Bus Products and Objects description

animeo KNX 4 DCE Motor Controller WM/DRM V AC Instructions

SeeTool - Solutions for KNX

ABB i-bus KNX Valve Drive Actuator VAA/S x Product Manual

Smart-house Dimmer Power dimmer up to 500W Type SH2D500W230

INSTABUS RADIO GATEWAY

1. Use of the application program

Series Dimmer Actuator DMG 2, Upgrade Module DME 2 and Booster DMB 2 DMG DME DMB

KNX Room temperature controller

Use of the application program. Contents. instabus EIB Application program description. September S2 Room temperature controller

HDL KNX / EIB BUS. Dimmer Actuator. 1/43. Light Technology Nederland ditributor of HDL

The specifications are classified as follows: Characterization, type and order-number. Mode of functioning. Technical data.

RAM 712 KNX room thermostat for surface-mounted and flush-mounted installation

Rev Product Manual ABB i-bus KNX. Heating actuator 1gang with 6164/11 U-500. Power and productivity for a better world TM

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

dmx2pwm 9 channel dimmer setup manual

16-Channel Yearly Time Switch TR 648 S DCF

Switch actuator. Movement detector Move/monitoring 1305/1.0, Art. No , ,

KNX Powerline PL 110. KNX Association

ABB i-bus. KNX Weather Station WS/S Product Manual

Use of the application program. Contents. 1. Functional description General. GAMMA instabus Application program description.

KNX manual High-performance switch actuators RM 4 H FIX1 RM 8 H FIX2

LED Driver Compact dimming

LED Driver Compact dimming

LED Driver Compact dimming

EY-EM 527: Remote I/O module, ecolink527

User manual. KNX MultiController DALI. Article number: 5410x / 5411x. function Technology AS

animeo KNX 4 DC 2 A Motor Controller WM 24 V DC Installation manual

PRODUCT MANUAL. ABB i-bus KNX VC/S 4.x.1 Valve Drive Controller

DEIF A/S. TAS-311DG Selectable AC transducer J (UK) Installation and start up instructions

PHASED OUT. LED Driver Compact dimming. Driver LCAI 55W 900mA 1750mA ECO C ECO series

theben Fan Coil Actuator FCA 1 Fan Coil Actuator FCA 1 FCA Version: Jan-08 (Subject to change) Page 1 of 77

Fan Coil Actuator FCA 2

IBS IP CDIO/R 24-8 IBS IP CDIO/R 24-8/SF

LED Driver Linear / area dimming

LED Driver Compact dimming

LED Driver Linear / area dimming

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

KNX ON/OFF controller 4 contacts 16A

PHASED OUT. LED Driver Linear / area dimming. Driver LCAI 20W 350mA 550mA ECO lp ECO series

PHASED OUT. LED Driver Compact dimming. Driver LCAI 55W 900mA 1750mA ECO SR ECO series

LED Driver Linear / area dimming. Udriver LCAI 20W 350mA 550mA ECO lp ECO series

Pulse Scaler for DIN Rail Attachment

PHASED OUT. LED Driver Linear / area dimming. Driver LCAI 20W 150mA 400mA ECO lp ECO series

Use of the application program. Contents. 1. Functional description General. GAMMA instabus Application program description.

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

Operating Instruction

PHASED OUT. LED Driver Compact dimming. Driver LCAI 20W 350mA 900mA ECO SR ECO series

TD - Power Supply LP DALI&Switch Dim Mono PRE (CV) MM-IP20 User Manual

MOTION DETECTOR WITH CONSTANT LIGHT CONTROL DM KNT 003

LED Driver Constant voltage

EY-EM 522, 523: Remote I/O module, ecolink522, 523

LED Driver Compact dimming

83 Series - Modular timers 16 A. Features

Operating instructions II / 2004

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

FTU233. Ripple Control Receiver. Technical Data. Load Management Ripple Control

LED Driver Constant voltage

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

LED Driver Linear / area dimming

Catalogue 1SFC en, Edition 3 November 2003 Supersedes Catalogue 1SFC en, Edition 2 November Arc Guard System TVOC

LED Driver Constant voltage

Smart Dupline Wireless dimmer with energy reading Type SHJWD200WExxx

Brief description. Type overview

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

LED Driver Constant voltage. Udriver LCA 100W 24V one4all SC PRE PREMIUM series

CS-200. PORTABLE TRAFFIC LIGHT CONTROLLER (Software 1.05) OPERATION AND SERVICE MANUAL

21 VA (l max 20 5 ms) Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque Inhibiting torque

PHASED OUT. LED Driver Linear / area dimming. Driver LCAI 100W 350mA 900mA ECO INDUSTRY sl ECO series

User Manual. KNX MultiLight Dali. Article number: function Technology AS. Picture: KNX MultiLight products

Technical Manual MDT LED-Indicator

LED Driver Constant voltage

ABB i-bus KNX DALI Light Controller DLR/S M Product Manual

Transcription:

, GH Q631 0026 R0111 SK 0097 B97 The universal input/output device is a DIN rail mounted device. It is connected to the EIB via a bus connecting terminal. The device has 32 freely programmable inputs/outputs, each with a terminal for the connection of potential free contacts or signal lamps. It is therefore possible for example to control operating or display panels. The device requires an external auxiliary voltage which also serves as a reference potential for the inputs/ outputs (see also Chapter 1: System components/accessories). The channels that are used by the inputs are available for switching, dimming or for shutter control. The channels that are used by the outputs can switch signal lamps or LEDs either normally, inverted or make them flash. Technical Data Power supply EIB 24 V DC, via the bus line Auxiliary power supply Nominal values: 12 / 24 V DC Permitted range: 10 30 V DC Ripple voltage < 5 % Max. current under full load 2.8 A Inputs/outputs 32 can be assigned as inputs or outputs Permitted cable length < 10 m Scanning voltage of the inputs 12 / 24 V DC Signal level of the outputs same as auxiliary voltage (for 1 signal) Output current max. 80 ma per output Load types at the outputs resistive Connections EIB Bus connecting terminal included with supply Inputs/outputs 2 plug connectors each with 16 screw terminals Wire range 0.14 1.0 mm 2 Auxiliary voltage 1 plug connector with 2 screw terminals Wire range 0.14 1.0 mm 2 Operating and display elements LED and push button for assigning the physical address Type of protection IP 20, EN 60 529 Ambient temperature range Operation 5 C 45 C Storage 25 C 55 C Transport 25 C 70 C Design modular installation device, prom Housing, colour Plastic housing, grey Mounting on 35 mm mounting rail DIN EN 50022 Dimensions 90 x 72 x 64 mm (H x W x D) Mounting depth/width Weight Certification CE norm 68 mm / 4 modules at 18 mm 0.16 kg EIB-certified in accordance with the EMC guideline and the low voltage guideline Page 1 of 10

, GH Q631 0026 R0111 Application programs Number of Max. number of Max. number of communication objects group addresses associations Switch Edge Dim Shutter Value Cyclic /1 67 250 250 Dimension drawing 58 44 72 Wiring diagram SK 0040 Z98 45 90 1 Programming LED 3 Input/output contacts 2 Designation plate 4 Connection for auxiliary supply 5 Bus connecting terminal Note If the LEDs glow faintly in the OFF state with a 24 V auxiliary supply, it is possible to avoid this by reducing the voltage to 12 V. When connecting the display and operating elements to the universal I/O device, ESD (Electro Static Discharge) protective measures should be observed. It is sufficient for the electrician to discharge at earth potential before beginning the installation. In order to avoid electrostatic discharges during normal operation, any conductive parts connected to the input/output terminals of the device must be protected against unintentional touch. Page 2 of 10

, GH Q631 0026 R0111 Switch Edge Dim Shutter Value Cyclic /1 Selection in ETS2 ABB In/Output Binary/binary The application program can provide up to 67 communication objects, depending on the settings selected in the parameters. Due to the large number of communication objects and parameters, the program memory is clearly larger than that of many other devices. It therefore takes several minutes to load the parameters. Channels 1 to 32 can be individually selected as inputs or outputs. Channels which are parameterised as outputs each use one communication object whereas channels that are parameterised as inputs have one or two objects. If a channel does not have a function, ETS2 does not display any objects for this channel. Channels that are used as outputs can control signal lamps or LEDs (see Switch ). Channels that are used as inputs can send switching telegrams (see Edge ), dimming telegrams (see Dim ), shutter control telegrams (see Shutter ) or 1 byte value telegrams (see Value ). To avoid an excessive bus load, the following rules should be noted: The repetition intervals for the cyclical sending of telegrams should be as long as possible and channel 32 should be used for monitoring the auxiliary than 3 seconds, the object Output voltage. This monitoring function also prevents the switching on and off of the auxiliary voltage from being evaluated as a reaction at the inputs. After programming the device, the status of the display driver must be defined uniquely with an ON or OFF telegram. Higher-level functions Channel 32 is of particular importance. If its parameter Function is set to none, it is used internally for monitoring the auxiliary supply. If the auxiliary supply fails, object no. 31 Telegr. aux. voltage fault sends a telegram with the value 1. All the channels that are used as inputs are blocked. Approximately 1 second after the auxiliary supply has been restored, the value of the object is set to 0 and the inputs are enabled again. If channel 32 is used as an input or an output, the auxiliary supply is not monitored. Objects with nos. 64 to 66 have special functions that cannot be parameterised. If object no. 64 Lamp test receives the value 1, all the output channels switch on. If the object value is 0, the outputs switch according to their parameter settings and their own object values. If the bus voltage fails, the values of the communication objects and the internal data is saved for a certain period (20 s... 5 min). Once the bus voltage has been restored, the device checks whether any data has been lost. If no data loss has occurred, all the communication objects maintain their values and the time delays are extended by the duration of the bus voltage failure. As soon as a data loss is detected, all the communication objects are set to the value 0 and all the outputs are set to their parameterised values. Object no. 65 Output fault is used to detect and display faulty or shortcircuited outputs. Every time there is a change in one of the outputs, the function is checked by an internal status display of the same input channel. If this status display fails to appear for more fault sends a telegram with the value 1 If object no. 66 Block inputs has the value 1, the inputs are disabled. If it has the value 0, the inputs are enabled again after approx. 1 second. As an alternative to using a communication object to block the inputs, it is also possible to block them using a switch between input terminal 32 and the minus terminal of the auxiliary supply provided that input 32 is being used to monitor the auxiliary supply. If both object no. 66 and input 32 are being used to block the inputs, input 32 has priority. Switch The ETS2 program displays a communication object with the function Display driver for all the channels that are assigned the function of Display driver. Depending on the value of the object, it is possible to set whether a connected lamp should be switched on or off or should flash with one of three selectable frequencies. Page 3 of 10

, GH Q631 0026 R0111 Edge Channels that are assigned parameters as inputs with the function switch sensor, can be linked with switch or push button contacts. It is possible to set the reaction to rising edges (close) or falling edges (open), depending on the contact type. If the function Cyclic sending is activated, the repetition rate can be set using the two parameters Factor and Time base. Dim ETS2 displays two communication objects for the channels that are parameterised as switch/dimming sensors. If an input is to be used for dimming, the parameter Contact type must be set to normally open contact or normally closed contact. Normally the start/stop process is used for dimming which means that after a long operation, the input object sends a telegram with the command Dim up (or down). Once the operation has finished, the object sends a stop telegram. According to the EIB Interworking Standard, the object can also send telegrams for dimming step-bystep. In this case, it is also necessary to indicate the time for automatic repetition of the telegrams for stopping and the size of the dimming steps. Shutter ETS2 displays two communication objects for the channels that are parameterised as shutter sensors. If an input is to be used for shutter control, the parameter Contact type must be set to normally open contact or normally closed contact. The default settings are selected so that two channels can be used to gether. The input with the uneven channel number lowers the shutter while the input with the even number raises the shutter. The input also distinguishes between a long and short operation during shutter The 1 bit communication object sends a switching telegram after a short operation. The value of the telegram is determined by the parameter Reaction to short signal. After a long operation, the 4 bit communication object sends a dimming telegram. The value of the telegram is set in the parameter Reaction on long signal. control. There are two basic operating The default settings are selected so that two channels can be used to gether. The input with the uneven channel number switches off or dims down and the input with the even number switches on or dims up. If the parameter Reaction to short signal is set to TOGGLE and the parameter Reaction to long signal is set to Dim up/down..., a single push button contact is enough to be able to switch on or off and dim up or down. This corresponds to the function of a conventional touch dimmer. methods depending on the project and customer requirements : short operation for stopping and step-by-step lamella adjustment, long operation for raising or lowering the shutters completely short operation for raising or lowering the shutters completely, long operation for stopping and step-bystep lamella adjustment. The two parameters Reaction on short signal and Reaction on long signal must be set according to these two options. If the long signal is used for lamella adjustment, it can also be repeated cyclically. The interval for repeating the telegram and the operating time of the relay in the controlled actuator should therefore match. The simultaneous selection of the settings raise shutter and lower shutter for the parameters Reaction on short signal and Reaction on long signal should be avoided in principle. Page 4 of 10

, GH Q631 0026 R0111 Value Channels that are parameterised with the function Send value (EIS 6), can either be linked with switch or push button contacts. ETS2 displays a 1 byte communication object for each of these channels for the rising edge (close contact) and one object for the falling edge (open contact). The parameters Reaction on rising edge or Reaction on falling edge can be set according to the connected contact. If the parameter is set to Initial value..., the communication object always sends telegrams with the value that has been assigned in the parameters. If the parameter is set to Object value..., the value can be changed externally by another telegram. It is therefore possible for example to adapt predefined brightness values at a later stage without having to recommission the device. If the function Cyclic sending is activated, the repetition rate can be set separately for the reaction to rising or falling edges using the two parameters Factor and Time base. If the settings send initial value and send initial value cyclically are selected in the parameters, the read flag must be removed for the associated channel object. Page 5 of 10

, GH Q631 0026 R0111 for setting no function for channels 1... 32 31 1 bit 32: Input (EIS 1) Telegr. aux. voltage fault 64 1 bit Input telegr. Lamp test 65 1 bit Output fault Telegr. switch 66 1 bit Input telegr. Block inputs for setting display driver for channels 1... 32 0 1 bit 01: Display driver Display driver 1 1 bit 02: Display driver Display driver 31 1 bit 32: Display driver Display driver for setting switch sensor for channels 1... 32 0 1 bit 01: Switch sensor Telegr. switch 1 1 bit 02: Switch sensor Telegr. switch 31 1 bit 32: Switch sensor Telegr. switch for setting switch/dimming sensor for channels 1... 32 0 1 bit 01: Dimming sensor Telegr. switch 1 1 bit 02: Dimming sensor Telegr. switch 31 1 bit 32: Dimming sensor Telegr. switch 32 4 bit 01: Dimming sensor Telegr. relative dimming 33 4 bit 02: Dimming sensor Telegr. relative dimming 63 4 bit 32: Dimming sensor Telegr. relative dimming for setting shutter sensor for channels 1... 32 0 1 bit 01: Shutter sensor Telegr. shutter Up-Down 1 1 bit 02: Shutter sensor Telegr. shutter Up-Down 31 1 bit 32: Shutter sensor Telegr. shutter Up-Down 32 1 bit 01: Shutter sensor Telegr. lamella adj./stop 33 1 bit 02: Shutter sensor Telegr. lamella adj./stop 63 1 bit 32: Shutter sensor Telegr. lamella adj./stop for setting send value (EIS 6) for channels 1... 32 0 1 byte 01: Input (rising edge) Telegr. value 1 1 byte 02: Input (falling edge) Telegr. value 31 1 byte 32: Input (rising edge) Telegr. value 32 1 byte 01: Input (falling edge) Telegr. value 33 1 byte 02: Input (falling edge) Telegr. value 63 1 byte 32: Input (falling edge) Telegr. value Page 6 of 10

, GH Q631 0026 R0111 Parameters The default setting for the values is printed in bold type. For channels 1 32: Function none display driver switch sensor switch/dimming sensor shutter sensor send value (EIS 6) only for channel 32 with no function: Monitoring of auxiliary voltage is NOTE activated for function display driver : Object value = 0 ON OFF flash with approx. 0.5 Hz flash with approx. 1 Hz flash with approx. 2 Hz Object value = 1 ON OFF flash with approx. 0.5 Hz flash with approx. 1 Hz flash with approx. 2 Hz Initial value ON OFF flash with approx. 0.5 Hz flash with approx. 1 Hz flash with approx. 2 Hz for switch sensor function: Reaction on rising edge none ON OFF TOGGLE Reaction on falling edge none ON OFF TOGGLE Cyclic sending no if ON if OFF if ON and OFF only for ON and OFF : Settings apply for ON and OFF NOTE for cyclic sending: Factor (5 255) 20 Time base 100 ms 1 s 10 s 1 min 10 min 1 h Page 7 of 10

, GH Q631 0026 R0111 for function switch/dimming sensor : Contact type normally closed contact normally open contact for uneven channel numbers: Reaction on short signal OFF ON TOGGLE Reaction on long signal dim down (stop telegram) dim down (dimming steps) dim up (stop telegram) dim up (dimming steps) dim up/down (stop telegram) dim up/down (dimming steps) only for even channel numbers: Reaction on short signal OFF ON TOGGLE Reaction on long signal dim down (stop telegram) dim down (dimming steps) dim up (stop telegram) dim up (dimming steps) dim up/down (stop telegram) dim up/down (dimming steps) Input signal is interpreted as long 0.4 s / 0.5 s / 0.6 s / 0.8 s / 1.0 s / from 1.2 s / 1.5 s / 2.0 s only for dimming steps: Telegram is repeated every 0.4 s / 0.5 s / 0.6 s / 0.8 s / 1.0 s / 1.2 s / 1.5 s / 2.0 s Change of brightness 100 % / 50 % / 25 % / 12.5 % / 6.25 % / 3.12 % / 1.56 % for shutter sensor function: Contact type normally closed contact normally open contact only for uneven channel numbers: Reaction on short signal move shutter DOWN move shutter UP move shutter UP and DOWN lamella adjustment DOWN lamella adjustment UP Reaction on long signal move shutter DOWN move shutter UP move shutter UP and DOWN lamella adj. DOWN (cycl. sending) lamella adj. UP (cycl. sending) lamella adj. UP and DOWN (cycl. s.) only for even channel numbers: Reaction on short signal move shutter DOWN move shutter UP move shutter UP and DOWN lamella adjustment DOWN lamella adjustment UP Reaction on long signal move shutter DOWN move shutter UP move shutter UP and DOWN lamella adj. DOWN (cycl. sending) lamella adj. UP (cycl. sending) lamella adj. UP and DOWN (cycl. s.) Input signal is interpreted as long 0.4 s / 0.5 s / 0.6 s / 0.8 s / 1.0 s / from 1.2 s / 1.5 s / 2.0 s only for cyclical sending: Telegram is repeated every 0.4 s / 0.5 s / 0.6 s / 0.8 s / 1.0 s / 1.2 s / 1.5 s / 2.0 s Page 8 of 10

, GH Q631 0026 R0111 for function send value (EIS 6) : Reaction on rising edge none send initial value send initial value cyclically send object value send object value cyclically Initial value 255 only for cyclical sending: Factor (5 255) 20 Time base 100 ms 1 s 10 s 1 min 10 min 1 h Reaction on falling edge none send initial value send initial value cyclically send object value send object value cyclically Initial value 255 only for cyclical sending: Factor (5 255) 20 Time base 100 ms 1 s 10 s 1 min 10 min 1 h Page 9 of 10

, GH Q631 0026 R0111 Page 10 of 10