Size : Connection End : Min Temperature : Max Temperature : Materials : Cast iron body

Similar documents
Size : Connection Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Brunata Optuna H. Properties. Counter

Digital flow transmitter for continuous flow measurement

WESAN WP E ELECTRONIC METER WOLTMAN

Residential Water Meters

SONO 1500 CT Ultrasonic flow sensor

EW447-EW452 Series Mechanical Heatmeters FOR HEATING AND COOLING APPLICATIONS

WATER METERS M SERIES WATER METERS INSTALLATION, OPERATION AND MAINTENANCE GUIDE METAL M SERIES WATER METER PLASTIC M SERIES WATER METER

Inexpensive PD for Boiler Feed Water and Oil FLOWPET-EG

Digital flow ELEMENT transmitter for continuous flow measurement

Electromagnetic Flow Transmitter

WATERFLUX 3070 Technical Datasheet

SONOMETER TM 1100 Ultrasonic compact energy meter

Brunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2

Bulk water meter. All that c ou n t s. EnergyMetering

Electronic Heating Energy Meters

UFM 800 W, C Ultrasonic flowmeter for water and wastewater

KMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

FLOWPET-NX (Oil Service Mechanical Register)

wprime TM Series 280W-CI ULTRASONIC WATER METER

Siemens Switzerland Ltd HVAC Products. SIEMECA Electronic Heat and Cooling Meters

KMS502F. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Flanged Flowmeters FEATURES: (sizes: 25mm to 200mm)

RAY MECHANICAL COMPACT METER. 4 MID approved class 2 from ND 15 mm qp 0,6 m3/h up to ND 40 mm qp 10 m3/h

INLINE flowmeter for continuous flow measurement

Applications. Features RESIDENTIAL ULTRASONIC WATER METER. Revenue metering Residential submetering Commercial buildings.

SONOMETER TM 1100 Ultrasonic compact energy meter

KMS101W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S100 display

FLOWPET-EG. Description 1 Accumulated total flow (8-digit) 2 Instantaneous flowrate, L/h (mode:b1) and L/min (mode:b2) Selectable with

SonoMeter 31 Energy Meters

Design and applications

SVM F27 Compact. Ultrasonic heatmeter. Data sheet

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement

FLOMID FX Electromagnetic Flowmeter

KFS-EM. Overall length. Al. PTFE coated Alu, painted Al. coated Methacrylate / acrylic nitrite

Applications. Features RESIDENTIAL ULTRASONIC WATER METER. Revenue metering Residential submetering Commercial buildings.

Instruction. SONOMETER 1100 Ultrasonic compact energy meter. 1.0 Table of contents. 2.0 Safety notes and product information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flowmeter for continuous flow measurement

SVM F27 / C27. Ultrasonic BTU meter for heating or cooling. Data sheet

Digital flowmeter for continuous flow measurement

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approval with dynamic range up to 1:250 (qi:qp) MID in class 2 (depends on meter size), standard 1:100

OPTIFLUX 1000 Technical Datasheet

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

2-Way Proportional Logic Cartridge Valve Model FE.. (Series 1X and 2X) PSI (315 bar) F with electrical connection 12 X Y

ULTRAFLOW. Application. Cooling flow sensor. Ultrasonic flow sensor. Compact design. Static meter with no moving parts. Large dynamic range.

ULTRAFLOW TS Application OIML R75 DS/EN 1434

The Kent Range of Metering Products Pulse Units

Electromagnetic Flow Measuring System Two-wire, loop-powered PROline promag 23 P

ULTRAFLOW TS PTB. Application. Ultrasonic flow sensor. Compact design. Static meter with no moving parts. Large dynamic range.

KFS. Flap-type flow meter. Design and range of application

WATERFLUX 3000 Quick Start

SITRANS F flowmeters. SITRANS F System information MAGFLO electromagnetic flowmeters 4/9

MaxxFlow HTC. Product Information. Flow Measurement for Dry Bulk Solids

ULTRAHEAT / ULTRACOLD T330. The Evolutionary. Ultrasonic Heat Meter / Cooling Meter. Ultrasonic Heat Meter / Cooling Meter.

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,

Infocal 9 Energy calculator

SAT.. Electromotoric actuators for valves ACVATIX. with a 5.5 mm stroke and 300 N positioning force

TS-WS-07 Wireless Indoor/Outdoor 8-Channel Thermo-Hygrometer with Jumbo Display User Manual

SonoSelect 10 and SonoSafe 10 Energy Meters

ph or ORP Transmitter

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters. 4/18 Siemens FI

Coriolis Mass Flow Measuring System promass 40 E

INSERTION paddle wheel flowmeter for continuous flow measurement

MID MP-01, MP WATER MEASUREMENT

Side. Channel Blower APEX DARGANG MACHINERY CORPORATION

MaxxFlow HTC Flow measurement for dry bulk solids

Lowara. Centrifugal pumps with open impeller and flanged connections. SHO Series MARKET SECTORS CIVIL, INDUSTRIAL.

ULTRASONlC FlOWMETER SAMPLE BOOK. TYPE:LRF-3300S Concentrating on Flow Measurement

MS 5000 CIAO SENSOR EXTREMELY EASY TO INSTALL THANKS TO PATENTED WRAPPER FIXING SYSTEM

Digital inductive conductivity transmitter

flowiq 3100 Data sheet

RAY COMPACT ENERGY METER MECHANICAL

TIDALFLUX 2300 F Technical Datasheet

Release A Member of the

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

WATERFLUX 3000 Quick Start

ULTRAHEAT / ULTRACOLD T330. The Evolutionary. Ultrasonic Heat Meter / Cooling Meter. Ultrasonic Heat Meter / Cooling Meter.

www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER

MHPS MHPS. Modular pressure transmitter. Technical documentation. Table of content. Characteristics - applications - technical data

RAY MC COMPACT ENERGY METER MECHANICAL

SENA INSTRUCTION MANUAL

Repair Manual MWS45A-MWS50A-MWS55A MW32A-MWS36A-MWS40A. Ref Rev.D General Pump is a member of the Interpump Group

NUBIS. R t o WATER MEASUREMENT

RCM DIRECT READING FLOWMETER

Metering systems 0474EN April 2018 Domestic water meter

INTERAPID Small Bench SHE.30 or SHE.35

LQ510. Density (Consistency) Meter. Introduction. Specifications EJL- 123

PURESTREAM SYSTEM - ASSEMBLY GUIDE

Split case double suction centrifugal pump. Technical data Serie: DPAS C

Model Sono-Trak Transit Time

SONOMETER 2000 Ultrasonic heat meter

Laser LA-4P. Operating instructions

Heat meter Q heat 5 US

Q water 5.5. Electronic water meter. Data sheet DST1-QWA5-EN0 WMEAP / V 2.1

ULTRASONIC FLOW METER FT101

The innovative way forward symphonic sensor net radio system

Smart Electromagnetic Flowmeter Open channel Flowmeter Detector

FLOW SWITCH 600 Series Velocity Flow Sensor. Instruction Manual

Transcription:

Size : Connection End : Min Temperature : Max Temperature : DN 50 to 200 Flanged R.F. PN10/16 0 C ( for cold water type ) + 90 C (for hot water type ) Max Pressure : 16 Bars Specifications : Horizontal Woltmann Dry dial Magnetic transmission Materials : Cast iron body Page 1 sur 12

SPECIFICATIONS : Horizontal Woltmann with interchangeable insert MID R100 range in horizontal or vertical position(respect the flow direction indicated by the arrow ) Dry dial Magnetic transmission Direct reading on numerical rolls With lid Cast iron body USE : Water distribution Min and max temperature Ts : 0 C to 30 C for cold water type Ref.1738 and 1758 Min and max temperature Ts : 30 C to 90 C for hot water type Ref.1739 and 1748 Max Pressure Ps : 16 bars HEAD LOSS : Flow (m3 / h) TYPICAL ERROR CURVE : Error in % Q1 : Min. flow Q2 : Transitional flow Q3 : Nominal flow Q4 : Max. flow Page 2 sur 12

RANGE : Cold water meter flanged PN10/16 Ref.1738 DN 50 to 200 Hot water meter flanged PN10/16 Ref.1739 DN 50 to 200 Cold water meter flanged PN10/16 with impulse emitter (1x100L) Ref.1758 DN 50 to 200 Hot water meter flanged PN10/16 with impulse emitter (1x100L) Ref.1748 DN 50 to 200 MATERIALS : Item Designation 1 Lid 2 Cup 3 Counter with glass 6 mm thickness 4 Antimagnetic ring 5 Plate 6 Ring cup 7 Sealing screw 8 Screw 9 Washer 10 Mechanism 11 O ring 12 Cast iron body Page 3 sur 12

ACCESSORIES : LCD counter Ref. 1749021 LCD counter with reset Ref. 1749023 Double LCD counter with reset Ref. 1749022 Wireless radio MBUS converter Ref. 1749006 MBUS converter PAD PULSE Ref. 1749015 MBUS converter PAD PULSE up to 4 meters Ref. 1749017 Page 4 sur 12

SIZE ( in mm ) : Ref Calibre 50 65 80 100 125 150 200 1738 1739 1748 1758 L 200 200 225 250 250 300 350 h 78 87 95 106 117 134 165 H 123 123 149 147 274 311 365 Weight (Kg) 8.1 9.3 14.5 16.6 20.5 33.6 43.6 FLANGES SIZE ( in mm ) : Ref. DN 50 65 80 100 125 150 200 Ø C 102 122 138 158 188 212 268 1738 Ø D 165 185 200 220 250 285 340 1739 Ø K 125 145 160 180 210 240 295 1748 Nb x Ø L 4 x 18 4 x 18 8 x 18 8 x 18 8 x 18 8 x 22 12 x 22 1758 b 20 18 20 20 22 22 24 e 2 2 2 2 2 2 2 Page 5 sur 12

TECHNICAL FEATURES : DN 50 65 80 100 125 150 200 Max flow Q4 max ( m3/h) 50 78.7 125 200 200 312.5 500 Nominal flow rate Q3 ( m3/h ) 40 63 100 160 160 250 400 Min flow Q1 ± with 5% error ( m3/h ) Transitional flow rate Q2 with ± 2% error ( L/h ) 0.40 0.63 1.00 1.60 1.60 2.5 4 0.64 1.008 1.6 2.56 2.56 4 6.4 Min reading ( l ) 0.5 0.5 0.5 0.5 0.5 5 5 Max reading ( m3 ) 999999 999999 999999 999999 999999 9999999 9999999 Max head loss P at nominal flow rate Q3 ( bar ) 0.16 0.25 0.16 0.25 0.16 0.16 0.1617 IMPULSE EMITTER SPECIFICATIONS : REED contact Max voltage : 24 V Min voltage : 0.02 V Max bearable Current : 1.2 A 2 wires cable 3 meters lenght Normaly opened contact Contact in Rhodium Contact rating 10W Switching current 0.5A Max resistance contact 0.1 Ohm Min breakdown voltage 150V Min insulation resistance 10 9 Ohm Max operate time 0.5 ms Max release time 0.3 ms Max capacitance 0.5 pf Min resonant frequency 5000 Hz Max operation frequency 400 Hz Max switching voltage : 24 V Min voltage : 0.02 V Max current : 1.2 A Cable 2 wires 3 meters long PULSE POSSIBILITIES : Pulse Number 1 By multiple of 100 liter for bore 50 to 150 1000 liter for bore 200 Page 6 sur 12

LCD COUNTER ( OPTION ) : Use of this device allows grouping and reading of the impulse signals generated by up to 4 water meters. It is possible to set the pulse value for each input signal independentely. Up to 4 entries Max reading : 1999.999 m 3 Settable impulse values : 1, 2.5, 10, 25,100 or 1000 L/impulse Wall mounting with 2 screws Ø6 mm Power supply by lithium battery ( 8 years lifetime ) External dimensions : 89 x 73 x 42 mm IP protection : IP54 Page 7 sur 12

LCD COUNTER SETTING : K1 H7-BM1 is equipped with 3 buttons and LCD display. K1 button is located externally near LCD display. K2 and K3 buttons are located internally as showed in the following picture. K1 button is used in normal operating mode, for switching the display view to another channel. Setting the pulse value - Press button K1 for choosing the correct channel. - Wait until the reading value appears. - Press the button K2, the display shows the current pulse value. - It is possible to change the pulse value by pressing button K3. - For setting the value you can press button K2 or wait a few seconds. Set the starting reading value - Press button K1 for choosing the correct channel - While the display show the channel number, press button K2. In this way the figure starts flashing indicating the quantity of liters. - Press button K3 for setting the desired starting reading value. You can press button K2 for moving to the second position. - Repeat the previous operation for all the positions showed on the display. After pressing button K2 on the last position, the reading value is stored. Attention It is possible to set the starting reading value after having initialy set the pulse rate. Page 8 sur 12

DIAL : STANDARDS : Fabrication according to ISO 9001 : 2008 ICIM and IQNET Flanged according to EN 1092-2 PN16 DIRECTIVE 97/23/CE : Products excluded from directive ( article 1, 3.2 ) Water meter according to 2004/22/CE MID annex B ADVICE : Our opinion and our advice are not guaranteed and SFERACO shall not be liable for the consequences of damages. The customer must check the right choice of the products with the real service conditions. Page 9 sur 12

INSTALLATION INSTRUCTIONS OF WATER METER BEFORE INSTALLATION : Pipe-line must be cleaned and free from residual of weldings,rubbish,shaving and every kind of extraneous materials. Pipe-line must be perfectly aligned and their support properly dimensioned so that there s no external constraint. Tighten the bolts in cross Use the right bolt tightening so that the ends won t be damaged. It s recommended to install a strainer before the water meter if there are some solid particles in the water. Installation of the meters in the vicinity of pumps must be avoided. It is advisable to install the meter as far as possible from them. Make sure all the water supply outlets, served by the meter, sit higher than the meter itself otherwise its metering precision could be altered. The highest position of the count itself as the recording of the counter may not be reliable. To address these possibilities, simply place the meter after a 'large upward curve that ensures always a pipe completely filled with water (Fig 1). This will prevent air bubbles that could affect the accuracy of measurement Respect the flow direction indicated by the arrow. We recommend installing a valve downstream and one upstream of the meter in order to facilitate a possible maintenance of the meter itself, without having to drain the complete pipeline. During the water meter commissioning it is advisable to open first the valve placed downstream of the meter (so to flood the mechanical part of the instrument) and then slowly open the valve located upstream of the meter. This will prevent possible water hammers or acceleration of the flow that could damage the moving parts of the instrument. In the event of devices installed upstream of the water meter (gate valves, curves, elbows, tees, reducers,...) it is recommended to follow the following points. These devices can generate flow turbulence that in the long run may damage the moving parts of the measuring instrument. The L1 and L2 lengths above are considered the minimum necessary. When possible, you should increase them. Valves placed upstream and downstream Upstream bottleneck Curve or T fitting Upstream bottleneck with conical fitting Page 10 sur 12

INSTALLATION POSITIONS (SUITE) : Two curves or one curve and T fitting Upstream increased pipeline Free discharge downstream TESTS : During the tests under pressure, water meter must be removed to avoid overpressure risks. INSTALLATION Please make the water flow slowly to avoid water hammer. The meter pit shall be protected from flooding, rainwater and frost. INSTALLATION POSITIONS : The counter should be normally placed in an horizontal position The counter can be installed vertically with ascending flow or tilted without suffering any damage. If necessary, the counter can be installed vertically with descending flow but the pipe should always be full of water in this case. NOTE: Never install the water meter in horizontal position with totalizer in upside down orientation. HORIZONTAL : MID R100 MID R100 ( Vertical dial assimilated to vertical position ) Page 11 sur 12

INSTALLATION POSITIONS : VERTICAL* : * : In vertical position, the pipe should always be full of water. MID R100 Page 12 sur 12