M6 JETSTREAM. Innovation with Integrity. Large Area Micro X-ray Fluorescence Spectrometer. Micro-XRF

Similar documents
M4 TORNADO PLUS. Innovation with Integrity. Super Light Element Micro-XRF Spectrometer. Micro-XRF

Bruker Nano. M4 tornado. High performance micro-xrf spectrometer. think forward

Lab Report XRF 441 Elemental distribution analysis on geological samples with the M4 TORNADO

FIRST Newsletter March 2013, Issue 20. Elemental Distribution Analysis of a Meteorite Sample from the Rochechouart Structure with the µ-xrf M4 TORNADO

ARTAX. Innovation with Integrity. Portable Micro-XRF Spectrometer. Micro-XRF

BRUKER ADVANCED X-RAY SOLUTIONS. SPECTROMETRY SOLUTIONS ARTAX mxrf SPECTROMETER

Processing of MA(or µ)-xrf Data with the M6 software

MICRO XRF OF LIGHT ELEMENTS USING A POLYCAPILLARY LENS AND AN ULTRA THIN WINDOW SILICON DRIFT DETECTOR INSIDE A VACUUM CHAMBER

FAST ELEMENTAL MAPPING WITH MICRO-XRF

Quantax 100 Low-Cost EDS System. Innovation with Integrity

ANALYTICAL MICRO X-RAY FLUORESCENCE SPECTROMETER

Product Information Version 1.1. ZEISS Xradia 410 Versa Submicron X-ray Imaging: Bridge the Gap in Lab-based Microscopy

Philip Sperling. Sales Science and New Materials, YXLON International GmbH, Essener Bogen 15, Hamburg, Germany.

Alignment of the camera

Material analysis by infrared mapping: A case study using a multilayer

Manufacturing Metrology Team

SUPPLEMENTAL MATERIAL

STEM Spectrum Imaging Tutorial

ADVANCED MEDICAL SYSTEMS PTE LTD Singapore Malaysia India Australia

QUANTAX FlatQUAD. Innovation with Integrity. EDS for SEM with the XFlash FlatQUAD EDS

Advancing EDS Analysis in the SEM Quantitative XRF. International Microscopy Congress, September 5 th, Outline

BF-X2. In-line 3D automated X-ray inspection system for Semiconductor, Power module inspection

Fast Laser Raman Microscope RAMAN

Super High Vertical Resolution Non-Contact 3D Surface Profiler BW-S500/BW-D500 Series

QUANTAX. Innovation with Integrity. EDS with Slim-line Technology for SEM and TEM EDS

WITec Alpha 300R Quick Operation Summary October 2018

KEYENCE VKX LASER-SCANNING CONFOCAL MICROSCOPE Standard Operating Procedures (updated Oct 2017)

Discover the difference in efficiency

Y.MU 2000 Precise inspection results for sampling and 100% inspection

EE119 Introduction to Optical Engineering Fall 2009 Final Exam. Name:

Supplementary Figure S1. Schematic representation of different functionalities that could be

What Makes Push-broom Hyperspectral Imaging Advantageous for Art Applications. Timo Hyvärinen SPECIM, Spectral Imaging Ltd Oulu Finland

Microscopic Structures

JEM-F200. Multi-purpose Electron Microscope. Scientific / Metrology Instruments Multi-purpose Electron Microscope

Fast Laser Raman Microscope RAMAN

Kit for building your own THz Time-Domain Spectrometer

Data sheet for TDS 10XX system THz Time Domain Spectrometer TDS 10XX

Fastest high definition Raman imaging. Fastest Laser Raman Microscope RAMAN

QUANTAX EBSD with OPTIMUS TKD Transmission Kikuchi Diffraction Under Optimum Conditions

Amorphous Selenium Direct Radiography for Industrial Imaging

2014 HTD-E with options

X-RAY BACKSCATTER IMAGING: PHOTOGRAPHY THROUGH BARRIERS

A COMPARATIVE STUDY ON THE PERFORMANCE OF DIGITAL DETECTOR SYSTEMS FOR HIGH ENERGY APPLICATIONS

Full-screen mode Popup controls. Overview of the microscope user interface, TEM User Interface and TIA on the left and EDS on the right

MICROANALYSIS WITH A POLYCAPILLARY IN A VACUUM CHAMBER

Thermal management and thermal properties of high-brightness diode lasers

Veraviewepocs 2D High Speed Panoramic X-Ray Crystal Clear Images with Reduced Radiation

Measurement of Surface Profile and Layer Cross-section with Wide Field of View and High Precision

By using patented polycapillary optics this diffractometer obviates the need for monochromators and collimators for linear projection of X-Rays.

SECTION I - CHAPTER 2 DIGITAL IMAGING PROCESSING CONCEPTS

Film Replacement in Radiographic Weld Inspection The New ISO Standard

nanovea.com PROFILOMETERS 3D Non Contact Metrology

Advanced Technology and Manufacturing Institute. Zygo ZeScope

LYNXEYE XE-T. < 380 ev. Innovation with Integrity. Energy. Resolution. High-Resolution Position Sensitive Detector with Superb Energy Resolution XRD

inspexio SMX-225CT FPD HR

Zaidi Embong and Husin Wagiran Physics Department, University Of Technology Malaysia, P.O Box 791, 80990, Johor Baharu

Data. microcat +SPECT

3 Analytical report of glass beads from Hoa Diem site, Khanh Hoa, Viet Nam.

Analysis of paint pigments

Variable microinspection system. system125

Nano Beam Position Monitor

Scanning Electron Microscopy

MS260i 1/4 M IMAGING SPECTROGRAPHS

DEVELOPMENT OF A WAVELENGTH DISPERSIVE X-RAY FLUORESCENCE SPECTROMETER USING A MULTI-CAPILLARY X-RAY LENS FOR X-RAY DETECTION

ALTURA EDS. Rev. 0915

Basler Accessories. Technical Specification BASLER LENS C M. Order Number

DESIGN AND MEASUREMENT WITH A NEW PORTABLE X-RAY CAMERA FOR FULL-FIELD FLUORESCENCE IMAGING

X-Ray Spectroscopy with a CCD Detector. Application Note

Basler Accessories. Technical Specification BASLER LENS C M. Order Number

Examination, TEN1, in courses SK2500/SK2501, Physics of Biomedical Microscopy,

X-ray computed tomography applied to investigate ancient manuscripts

Oriel MS260i TM 1/4 m Imaging Spectrograph

Rad-icon Imaging Corp A Division of DALSA Corporation

WIDE ANGLE GEOMETRY EDXRF SPECTROMETERS WITH SECONDARY TARGET AND DIRECT EXCITATION MODES

Supplementary Figure 1

Very short introduction to light microscopy and digital imaging

Optical basics for machine vision systems. Lars Fermum Chief instructor STEMMER IMAGING GmbH

Bringing Answers to the Surface

LYNXEYE XE. Innovation with Integrity. High-Resolution Energy-Dispersive Detector for 0D, 1D, and 2D Diffraction XRD

Leica DMi8A Quick Guide

Olympus LEXT OLS 4000 Confocal Laser Microscope

IQI-Sensitivity and Applications of Flat Panel Detectors and X-Ray Image Intensifiers A Comparison

Non Destructive Analysis of Dyes and Ceramics

Low Voltage Electron Microscope

picoemerald Tunable Two-Color ps Light Source Microscopy & Spectroscopy CARS SRS

APPLICATION OF THE DIGITAL RADIOGRAPHY IN WELD INSPECTION OF GAS AND OIL PIPELINES

SMX-1000 Plus SMX-1000L Plus

X-ray generation by femtosecond laser pulses and its application to soft X-ray imaging microscope

The SS6000 Gold Mate Series For analyzing all precious metals and other elements from Mg to U

Horiba Jobin-Yvon LabRam Raman Confocal Microscope (GERB 120)

Georgia O'Keeffe. THE Alfred Stieglitz COLLECTION OBJECT RESEARCH Palladium print Alfred Stieglitz Collection. AIC accession number: 1949.

AutoMATE II. Micro-area X-ray stress measurement system. Highly accurate micro area residual stress

Fig.2: Scanner VistaScan for image plates

FEI Falcon Direct Electron Detector. Best Practice Document

3D Optical Motion Analysis of Micro Systems. Heinrich Steger, Polytec GmbH, Waldbronn

Large-Area CdTe Photon-Counting Pixel Detectors

Quick and simple installation and no maintenance needed. 3 Times More affordable Than a normal SEM. Obtaining results in less than 4 minutes

Principles of Design

EE119 Introduction to Optical Engineering Spring 2003 Final Exam. Name:

Transcription:

M6 JETSTREAM Large Area Micro X-ray Fluorescence Spectrometer Innovation with Integrity Micro-XRF

Spatially Resolved Elemental Analysis of Large Objects The Bruker M6 JETSTREAM is designed for the nondestructive elemental analysis of large samples. The mobility of the instrument allows it to be placed at the site of the object of interest, such as a gallery, museum or the shop floor. The performance parameters enable scanning areas of 800 mm x 600 mm with a variable spot size down to 100 µm and speeds of up to 100 mm/s. Fields of applicaton Cultural heritage science the ability to scan objects in-situ saves the user from having to transport and possibly jeopardize objects of immeasurable value Geoscience supports the analysis of large drill core sections or other mineral samples Failure analysis screening of big parts for flaws, inhomogenities and other features of interest.

Setting Standards in Micro-XRF Analysis High performance element distribution analysis of large samples The M6 JETSTREAM allows samples to be scanned either horizontally or vertically The instrument supports extremely fast measurement based on high excitation intensity and fast stage movement. On-the-fly measurement provides even further acquisition time optimization The spot size of the M6 JETSTREAM can be adapted in five steps to match the structure of the sample and the desired spatial resolution Bruker s advanced XFlash silicon drift detectors (SDD) are used for the detection of fluorescence radiation. They feature high count rate capability and best energy resolution over a wide count rate range Special safety circuitry provides optimal user protection against exposure to X-rays Ultrasound distance measurement safeguards against collision with the measurement object Regardless of sample size, the M6 JETSTREAM can be easily positioned due to its mobility. It can be dismantled into four parts which makes it transportable. (O) (S) (E) The M6 JETSTREAM provides (R) Highest excitation efficiency with microfocus tube and polycapillary X-ray optics with variable spot size Flexible acquisition programs for measuring single and multiple points and for distribution analysis in one or two dimensions line scan and mapping with flexible area size Distribution analysis with HyperMap, i.e. for saving a complete spectrum for every pixel, offering a wide variety of options for data post processing. Diagram of the M6 JETSTREAM set-up in the upright measure ment position, showing analysis object (O), spectrometer head (S), rig (R) and electronics compartment (E) (R) (O) (S) (E) Diagram of the M6 JETSTREAM set-up in the horizontal measurement position, showing analysis object (O), spectrometer head (S), rig (R) and electronics compartment (E)

Examination of Vertical Samples The analysis of works of art can provide valuable information about their history and authenticity, about required conservation procedures and previously performed restoration on the work of art. The transportion of valuable paintings has to be avoided due to their vulnerability, security issues and the resulting costs. Additionally, paintings are not available to the public if they are removed for analysis. Similar problems arise if the works of art are very large and heavy or even immobile, like murals. In these cases it is necessary to investigate works of art on site. This requires transport of the instrument to the site and its positioning in front of the work of art. The M6 JETSTREAM is constructed for this purpose. Application example Investigation of Rembrandt s Homer, dated 1663 Paintings by old masters often darken over time. An important question for the conservation and restoration of such a valuable historical painting is, whether the dark colors are caused by contaminations or if they are due to changes in pigment chemistry? If indeed changes have taken place, the original appearance of a painting was not only lighter but the colors may also have been different. The figure shows the painting Homer by Rembrandt and the element distributions of cobalt (Co) and lead (Pb). For lead the distributions of Pb M radiation and Pb L radiation are displayed. These types of radiation have a different energy which means they come from a different depth in the painting the Pb L radiation comes from deeper layers than the Pb M radiation. Homer by Rembrandt 82 cm x 107 cm Measured in 4 stitched sections with a step size of 500 µm (total approx. 3.5 megapixel) Pixel dwell time: 20 ms

Analysis of Pigment Distributions Cobalt pigments are typically blue. Depending on additional components this blue can have different shades. Pb oxide is a white pigment (white lead). The examination of the element distributions provides following results. This is of interest, because oil paint has the tendency to become more transparent over time. Pb M radiation can therefore give an impression of the modeling of light and dark areas in paintings that have changed over time. Cobalt distribution The Co intensity is high at the location of the cap on Homer s head and also on his waist belt. In the painting these parts appear in a yellowish brown. It is quite likely that the paint in these areas originally had a more bluish tone. Lead distributions While the Pb L distribution shows the pre sence of white lead through all paint layers, the low energy Pb M distribution shows the presence of lead only at the paint s surface. The alteration was caused by a change of the PbO pigment on the surface due to environmental influences. The degradation resulted in an overall dulling of the painting. Pigments in deeper layers were less affected by the degradation and therefore resemble the original white pigment distribution of the painting more closely. Co K Pb L Pb M Picture of Homer by Rembrandt Courtesy of Mauritshuis, Den Haag. Measurement data courtesy of Prof. J.Dik, G. van der Snickt, TU Delft Distribution of Co K radiation (blue pigment) Pb L radiation (high energy white pigment) Pb M radiation (low energy white pigment)

Examination of Horizontal Samples Very often samples need to be positioned horizontally for analysis. This can be the case either for cultural heritage samples like manuscripts as well as for large material analysis objects like solar cells, geological samples, etc. For this purpose the upper part of the instrument with the spectrometer head can be tilted by 90 for measuring in a top-down geometry. In this mode the sample has to be positioned on a stage, the height of which has to be adjusted according to the thickness of the sample. Application example Analysis of a drill core Drill cores are collected for various purposes and from different sites. Their examination can provide information on e.g. geo-history through their structure the sequences of rocks and sediments the paleo-climatological development through sediment layers. Both line scan and mapping measurement modes are useful for the analysis of drill cores, as shown in the figure below. Analysis of a drill core sample (a) (b) (a) Video mosaic image of a drill core with a size of approx. 17 cm x 9.5 cm. The line in the center indicates the position of a line scan extracted from the HyperMap database and shown in (c) (b) Map of the elements Ca, Fe, and Sr. The step size is 1.5 mm, resulting in a map of 1120 x 631 pixels, acquired within 90 min. (5 ms pixel dwell time) at an input count rate of 85 kcps (output count rate 65 kcps). (c) Line scan extracted from the HyperMap. The line was broadened by 5 pixels on each side to improve statistics. Note that the sharp increases in the Fe and Sr concentrations coincide with visible features in the map in (b). (c)

Built for Speed Video mosaic image of a Slavonic icon Diagram of the polycapillary optics used for X-ray beam focusing Sample view with two magnifications Two optical microscopes offer sample images of different sizes (approx. 30 x 22 mm² and 11 x 8 mm²) for orientation on the sample and for positioning of single point measurements. Analysis with various spot sizes The spot size can be changed without significant loss of excitation intensity by varying the working distance. The working distance is determined by the adjustable focal plane of the high resolution optical microscope. Mosaic images for large samples A complete video mosaic image can be collected for samples of all sizes. This allows fast orien tation on the sample (by point & click) and exact definition of the measurement area. Rapid analysis with small step size The step size needs to be small to attain high resolution. The exceptional speed of the M6 JETSTREAM based on high excitation intensity and detection efficiency in combination with the fast stage enables short measurement times. A dwell time of 0.1 ms can be selected in combination with the minimum step size of 10 µm. This results in a maximum stage speed of 100 mm/s! Translated into real world conditions, this means that, depending on sample size and required spatial resolution, high quality measurements can be performed within several minutes to a few hours. Largest pixel numbers for large area mapping with small step sizes The M6 JETSTREAM supports single maps with multi-megapixel resolution. This results in a spatial resolution of approximately 100 µm for the largest possible scan area.

All configurations and specifications are subject to change without notice. Order No.DOC-B81-EXS008, Rev. 2. 2. 2015 Bruker Nano GmbH. Printed in Germany. An Exceptional Micro-XRF Spectrometer for Exceptional Samples Technical specifications Excitation Rh-target microfocus-x-ray tube, 50 kv, 600 µa Polycapillary optics Filter wheel with 5 filters Spot size Adjustable in 5 steps from 100 to approx. 500 µm Detection 30 mm² SDD, energy resolution < 145 ev for Mn Kα Sample view 2 color cameras, capturing images with a size of 30 x 22 mm² and 11 x 8 mm², respectively. The high magnification camera permits setting of the focal and working distance Scanning range W x H x D: 800 x 600 x 90 mm³ Minimum step size 10 µm Measurement direction The measurement rig can be tilted by ± 10 in vertical measurement direction or to horizontal position for top-down measurement Software package Sophisticated software including instrument control, data acquisition, data evaluation and presentation, report generation Functionality Single point analysis Customizable automatic MultiPoint analysis Distribution analysis with HyperMap in one or two dimensions (linescan, mapping) Instrument size W x D X H: 1400 mm x 1800 mm x 1560 mm (horizontal position) W x D X H: 1400 mm x 650 mm x 2250 mm (vertical position) Weight: 200 kg The instrument can be dismantled into 4 parts for transportation Mains 100/240 V; 50/60 Hz; max. power consumption 400 W Bruker Nano GmbH Berlin Germany Phone +49 (30) 670990-0 Fax +49 (30) 670990-30 info.bna@bruker.com Bruker Singapore Pte. Ltd. The Helios Singapore Phone +65 (6500) 7288 Fax +65 (6500) 7289 info.bna.sg@bruker.com www.bruker.com/m6jetstream