STAFF User Manual. Manual Part #

Similar documents
8873 v3 Pathfinder Locator User Manual

User Manual 8880 Series Fault Finding & Locating Kit

User Manual Pathfinder Precision Locating System

Dynatel 2250E/2273E Advanced Cable and Fault Locator

Cable I.D. Live. Primary or Secondary In or Out of the Trench TX-Former to TX-Former TX-Former to Meter Energized or Grounded.

DynatelTM Cable Locator. Operators Manual. October Revision A

POWER TRACE TM TASCO, INC.

TAG5000 WIRELESS PHASER. Instruction Manual HD ELECTRIC COMPANY 1475 LAKESIDE DRIVE WAUKEGAN, ILLINOIS U.S.A.

TW-82 TW-82 ACCESSORIES. Operating Manual DIGITAL LINE TRACER F I S H E R R E S E A R C H L A B O R A T O R Y

User s Guide. 400A AC/DC Clamp Meter. Model MA220

F I S H E R R E S E A R C H L A B O R A T O R Y

AT Underground Cable/Pipe Locator System. Users Manual Mode d emploi Bedienungshandbuch Manuale d Uso Manual de uso Användarhandbok

User Guide. Digital AC/DC Clamp Meter Model 38394

User s Guide. Digital AC/DC Clamp Meter Model 38394

User Guide. AC/DC Mini Clamp Meter. Model Introduction. Large 3 3/4 digit LCD display with 40 segment bargraph

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

200Amp AC Clamp Meter + NCV Model MA250

TW-82 TW-82 ACCESSORIES. Operating Manual Revision Level 1 DIGITAL LINE TRACER

TW-82. Operating Manual DIGITAL LINE TRACER. Revision Level 1

AT Advanced Wire Tracer. Users Manual

DOCUMENT OBSOLETE. Dynatel. 2273M Cable/Pipe and Fault Locators 2273M-iD Cable/Pipe/Fault and Marker Locators with id Read/Write

Specifications for 3M Dynatel 2273M/M-iD Cable/Pipe and Fault Locators

User s Guide. Model MA A AC Mini Clamp-on Meter

A Sheath Fault Locator. 99 Washington Street Melrose, MA Phone Toll Free

This manual applies to the WT-RC-Ex receiver when used to locate all makes and models of 22 Hz and Wavetrak coded transmitters.

User s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130

TW-82 DIGITAL LINE TRACER. Operating Manual

Obsolete Document. Dynatel

PHASE ROTATION METER. Operating and Instruction Manual. a n d A C C E S S O R I E S

TW-82P DIGITAL LINE TRACER WITH PASSIVE POWER DETECTION. Operating Manual

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

DM-46 Instruction Manual

Pro871C Cable Locator Operating Instructions

INSTRUCTION MANUAL. MODEL: Vintage 60R. Vintage Series Guitar Amplifi er

True RMS AC / DC Power Clamp Meter Model

UTILITY LOCATING EQUIPMENT

Safety. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present.

UAT-600 Series. amprobe.com

L1070 and L1071 Portable Locator Catalog No and

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

MICROTOOLS MICRONETBLINK KIT

Passive Component LCR Meter

User s Manual. Ground Resistance Clamp On Tester MODEL

INDEX PREFACE... 1 CAUTIONS... 2 OPERATION ON SITE(9) STANDARD INSTRUMENT... 3 OPTIONAL ACCESSORIES... 4 OPERATION OF TRANSMITTER(3)...

Dynatel Cable/Pipe and Fault Locator 2273M Cable/Pipe, Fault and Marker Locator 2273M-iD

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control

INSTRUCTION MANUAL INF Fax: (503)

Rock Sounders. Weatherproof Wireless 900MHz Speaker System. User Guide. Model no.: GDI-AQRCK400 / AQRCK41

ER200 COMPACT EMERGENCY CRANK DIGITAL WEATHER ALERT RADIO OWNER S MANUAL

Autoranging Multimeter Extech EX503

For detailed specifications and ordering info go to

USER'S MANUAL DMR-6700

Armada Technologies Pro800D Hi-Power Wire and Valve Locator. Operating Instructions

Instruction Manual. Model XTpc-33 khz Pipe & Cable Locator

Installation and Operation Manual MSI. Multi-Sensor Interface Hub. Interface Module for all Sensors Network and Wireless CAUTION

DM-46 Instruction Manual

Using the USB Output Port to Charge a Device

User Manual Digital Wireless Rain Gauge

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

Far End Device II Model 1342

Dynatel. 2273M Cable/Pipe and Fault Locators 2273M-iD Cable/Pipe/Fault and Marker Locators with id Read/Write

3 Dynatel M Series Locating and Marking System DOCUMENT NEW- TO- THE- WORLD TECHNOLOGY OBSOLETE DAMAGE PREVENTION PIN- POINT ACCURACY SAFETY

Schooners II. Weatherproof Wireless 900MHz Speaker System. User Guide. Model no.: GDI-AQSHR200 / AQSHR21

Mo d e l Ma g h o r n Ma g n e t ic Lo c a t o r

Passive Component LCR Meter

User's Guide. Extech 800 Series 1000 Amp Clamp Meters with IR Thermometer

Armada Technologies Pro900 Advanced Underground Locator USER GUIDE

Armada Technologies Pro900 Advanced Underground Locator USER GUIDE

SCREENING EFFICIENCY TESTER Model 271

1507/1503. Insulation Testers. Users Manual

Loki Pipe & Cable Locators

Instruction Manual for Digital Grounding Resistance Meter. Table of Contents

P5100A & P5150 High Voltage Probes Performance Verification and Adjustments

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

Sheath Fault Locator Log Operation Manual

User Manual 4 wire Earth Resistance Tester Model GRT300

902 FC. HVAC True-rms Clamp Meter

Circuit Breaker Finder

Driveway Alarm INSTALLATION MANUAL

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

A-Frame Fault Locator

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

USER MANUAL Table of Contents

Pen Multimeter. Model

User Guide. 4 wire Earth Resistance Tester Model GRT Washington Street Melrose, MA Phone Toll Free

Pen Multimeter. Model

TraceMaster. Pipe and Cable Locator Multi-Frequency Receiver and Radio Linked to Transmitter. Instruction Manual

Instruction Manual for Digital Grounding Resistance Meter

A Channel Amplifier

Broadband Current Probe Series Operation Manual

Thermometer model 02059

AT-5000 Professional Underground Cable / Pipe Locator System

AT-4000 Series. Advanced Wire Tracer. Users Manual

2011 / Circuit Tracer

ECG PATIENT SIMULATOR FIVE LEAD

PixController, Inc. Wireless Vibration Sensor For Indoor and Outdoor Use

ECG PATIENT SIMULATOR SIX LEAD

PULSE OXIMETRY SIMULATOR

netzerotools.com 374/375/376 Users Manual Clamp Meter

Transcription:

STAFF User Manual Manual Part # 030-00085-00

Introduction Congratulations on the purchase of your new STAFF Secondary Fault Locator. The STAFF is specially designed to detect conductor to earth/ground faults in buried conductors. The Transmitter emits a signal. The Receiver detects the signal. You can locate the relative position of the buried utility, sonde or camera by following the tracing signal. Prepare for Use WARNING Electric shock hazard: Follow appropriate safety procedure and your companies policies. Tool is designed to detect electromagnetic field emitted from cables and buried metallic utilities. There are buried cables, pipes, and utilities this instrument CANNOT detect. LOCATING is not an exact science. The only certain way to be sure of the existence, location, or depth of buried utilities is to carefully expose (dig up) the utility. De-energize any circuits in or around the work area. Do not expose tool to rain or moisture. Use tool only for intended purpose as described in this manual Turn off transmitter before touching test lead or any un-insulated conductor. Do not connect to live voltage or active utility lines. Failure to observe these warnings could result in severe injury or death. DISCLAIMER OF LIABILITY RYCOM INSTRUMENTS, INC SHALL NOT BE LIABLE TO DISTRIBUTOR, RESELLER, OR ANY OTHER PERSON FOR ANY INCIDENTAL, INDIRECT, SPECIAL, EXEMPLARY OR CONSE- QUENTIAL DAMAGES, OR INJURY OF ANY TYPE WHATSOEVER, AND CAUSED DIRECT- LY OR INDIRECTLY BY PRODUCTS SOLD OR SUPPLIED BY RYCOM INSTRUMENTS, INC. Unpack your newstaff Directional Fault Finder. Make sure there is no shipping damage and all the parts are included. Locate the battery compartment inside the Transmitter. Remove the battery compartment door. Install the eight Duracell C batteries as marked. Locate the battery compartment on the back of the top tube of the STAFF. The cap unscrews counterclockwise. Insert the 6 "AA" Duracell batteries according to the label with the corresponding terminal (+/-) facing up. Note: For longer battery life and reliable operation under adverse conditions, use only Duracell alkaline batteries. 2

The STAFF Transmitter Controls and Indicators Power On Indicator Power On & Off I 8869 Tx Output Jack 4mm Bannana Tx Output Jack CAUTION Leathal Voltages May Be Present TX OUTPUT JACK The Red/Black Cord, connects here to create a circuit on the buried utility. POWER ON INDICATOR The red led will flash when unit is on.

STAFF Receiver Controls and Indicators SIGNAL STRENGTH Displays absolute signal strength from 0 to 99. DIRECTIONAL ARROW Indicates direction of fault. LOW BATTERY INDICATOR ON/OFF BUTTON REFERENCE Stores and displays starting signal strength when pressed ON/OFF Button Turns the unit on and off. REFERENCE Button When pressed it stores the signal strength and sets the reference mode. The tone will beep more rapidly as the STAFF detects a similar signal strength. Pressing the reference button again (after a reference has been taken) will display the original reference reading for 2 seconds. Turn the unit off and on to clear the reference. DIRECTIONAL ARROW After proper synchronization the arrows will direct the user to the fault. If the signal strength drops completely off in the area between the ground rod and the fault, the arrows will not properly display direction until the unit comes within range of the fault or ground rod. SIGNAL STRENGTH The Signal Strength is displayed in a value from 0 to 100. The closer to the ground rod and/or the fault will result in the highest reading. The signal strength may drop completely off in the area between the ground rod and the fault. LOW BATTERY The STAFF Locator will indicate low battery condition by displaying the Low Battery icon on the LCD screen. 3

Fault Locating with the STAFF Fault locating determines the position of an insulated break on an underground conductor. In the case of an insulation fault, some of the signal will return to the Transmitter attached to the Ground Rod through a break in the insulation. NEAR ACCESS POINT FAR ACCESS POINT RED BLACK A EARTH FAULT B BURIED CABLE RETURN PATH THROUGH SOIL It is generally a good idea to locate the conductor path before attempting to fault locate. If, during the path locate, an unusual amount of signal loss occurs, a part of the signal has escaped to ground in the last several feet. Note: Signal would go to ground at a grounded splice point, which would act as a fault during the path and fault locate. Once the path is determined and there is a general area where a fault is expected, additional current can be forced to flow through the fault by disconnecting and isolating the far access point. If the current has no path to ground at the far access point, it will be forced to seek ground at the fault. This will increase the current in the soil at the fault and detection of the fault. Use 815Hz when fault locating. STAFF Probe Fault Locating First, set the Transmitter to fault mode by pressing and holding the frequency button for ten seconds. When released the DFF symbol on the LCD will be displayed. Second, place the STAFF A-frame connected to the receiver into the ground in between the ground rod and the fault with the front spike toward the fault and the back spike toward the ground rod. Now turn the receiver on, this will sync the receiver to the transmitted signal. As you walk the path using the STAFF GRP, drop the probe every three or four steps. The bar graph will indicate the direction of the fault by blinking on the appropriate arrow. As you near an area of high current concentration in the soil, the Ground Rod or the fault, the center bars of the bar graph will blink faster or stay on. The fault lies in the center of the Ground Return Probe spikes. Ground Return Probe Insertion Circuitry between the ground spikes provides a path for current in the soil returning to the Ground Rod. The current enters one spike of the Ground Return Probe and exits the other spike. The GRP should be inserted into the soil with consistent force and depth. EARTH EARTH THE GROUND RETURN PROBE FRAME SHOULD BE IN LINE WITH, AND DIRECTLY ABOVE THE CABLE PATH. CABLE (END VIEW) BOTH SPIKES SHOULD EVENLY PENETRATE THE GROUND AND MAKE GOOD ELECTRICAL CONTACT. CABLE (SIDE VIEW)

Fault Locating with the 8880 STAFF 1) Locate path of faulted conductor 2) Remove power from faulted conductor 3) Disconnect loads and ground from both ends of target conductor and neighboring conductors 4) With transmitter off connect red lead to the faulted conductor and black lead to independent ground rod 5) Turn the transmitter on 6) Complete transmitter instruction before using GRP 7) Place GRP in soil with back spike approx. 2 yards from ground rod and front spike toward suspected fault 8) Turn receiver on (for proper synchronizing spikes must be in the ground before turning the unit to DFF mode.) 9) Using mode button toggle the mode out of DFF and then through the modes until DFF is displayed again on LCD. 10) Note numeric reading as reference to signal strength near fault 11) LCD will indicate fault direction 2 Meter Aprox. 12) Signal strength will fall as leaving the ground spike until passing the half-way point between ground spike and fault. Signal will start to rise from half-way point to fault. If the distance is great the signal strength may fall to non-detectable level and arrows may not stabilize through the center section. 99 78 61 54 40 15 ---- --- 15 40 54 61 78 99 13) Any synchronizing must be done near the ground rod with the spike in the ground before turning the unit to FF mode.

Faults Beneath Paved Surfaces A potential problem could exist if a fault should lie beneath a paved surface. In this case, the Ground Return Probe will be used in the dirt at the side of the paved area. Since the return current in the soil begins its return from the fault - like the spokes of a wheel laying on the ground - equal amounts of current will enter the GRP if it is placed on the ground and positioned broadside to the fault. At the point where the directional indication changes the fault will lie on a straight line projected at a right angle from the center of the GRP. The GRP adjustments can be made by slightly rotating the Ground Return Probe to find the directional change. The operator should record this line over the paved area. By repeating this procedure from another location near the paved area, another line will be produced. The intersection of the two lines is the location of the fault. PAVED ROAD SHEATH-TO-GROUND FAULT CABLE GROUND RETURN PROBE IS POSITIONED FOR A MINIMUM (NULL) RECEIVER DISPLAY. GROUND RETURN PROBE IS POSITIONED FOR A MINIMUM (NULL) RECEIVER DISPLAY.

STAFF Specifications Transmitter Operating Frequency Operating Temperature Hook-up Method 8 Hz Pulse -4 F to 133º (-20ºC to +55ºC) Direct Connection Load Matching Output Power Battery Types Battery Life Dimensions Weight 5 Ω to 2,000,000 Ω 100 volts to 1200 volts 8 - C Duracell alkaline batteries greater than 30 hours* 8.4 x 5.57 x 2.6 2.2 lbs (1kg) *depending on load, frequency and power setting

STAFF Specifications Receiver Operating Frequency Operating Temperature Battery Types Battery Life Dimensions Weight 8Hz Pulse -4 F to 133º (-20ºC to +55ºC) 6 - AA Duracell alkaline batteries greater than 30 hours* 8.4 x 5.57 x 2.6 2.2 lbs (2.8kg)

Factory Service If your STAFF Locator is not working properly, first call RYCOM Instruments, Inc. Tech Support at 800-851-7347 for assistance. If the locator is in need of repair, Tech Support will provide instructions for sending your locator to the closest factory approved service center. The instrument will be repaired and shipped back or you will be advise if the instrument is un-repairable. Note: There is a minimum charge for repair and handling. Warranty This instrument is under warranty for one year from the date of delivery against defects in material and workmanship (EXCEPT BATTERIES). We will repair or replace products that prove to be defective during warranty period. This warranty is void if, after having received the instrument in good condition, it is subjected to abuse, unauthorized alterations or casual repair. No other warranty is expressed or implied. The warranty described in this paragraph shall be in lieu of any other warranty, including but not limited to, any implied warranty of merchantability or fitness for a particular purpose. We are not liable for consequential damages.