Vol. Validation of FTIR Systems AIM-9000 Infrared Microscope Infrared Microscope. Convenience of a Wide-View Camera

Similar documents
Infrared Microscope AIM-9000 C103-E103B

Infrared Microscope. Dedicated AIMsolution Software. Hisato Fukuda. 1. Introduction. 2. Automatic Contaminant Recognition Function

Development and Applications of a Sample Compartment FTIR Microscope

LUMOS. Innovation with Integrity. FTIR Microscopy made easy FTIR

Bruker Optics Inc. Bruker Hong Kong Ltd. Billerica, MA USA Phone +1 (978) Fax +1 (978)

FTIR Spectrophotometer

Fourier Transform Infrared Spectrophotometer. IRTracer-100 C103-E091B

Spotlight 150 and 200 FT-IR Microscopy Systems

Spectrum 400. FT-IR and FT-NIR Spectrometer. There is only one answer.

Fourier Transform Infrared Spectrophotometer. IRAffinity-1S C103-E096

Diamond Analysis. Innovation with Integrity. Reliable identification and type determination by FTIR spectroscopy FTIR

Seized Drugs Operational Guidelines for the Thermo FTIR Comparative and Analytical Division

UV-VIS Spectrophotometer

Material analysis by infrared mapping: A case study using a multilayer

The operation manual of spotlight 300 IR microscope

Parameter Selection and Spectral Optimization Using the RamanStation 400

Chemistry 524--"Hour Exam"--Keiderling Mar. 19, pm SES

INFRARED ANALYSIS OF SINGLE AND MULTILAYER FILMS IN THE PRODUCTION AREA

C103-E076. IRAffinity-1. Shimadzu Fourier Transform Infrared Spectrophotometer

StarBright XLT Optical Coatings

Certified Reference Materials for UV, Visible, NIR and IR Molecular Spectroscopy

771 Series LASER SPECTRUM ANALYZER. The Power of Precision in Spectral Analysis. It's Our Business to be Exact! bristol-inst.com

Metal coatings analysis using the handheld Agilent 4100 ExoScan FTIR

Fourier Transform Infrared Spectrophotometer. IRAffinity-1S C103-E096C

The FTNIR Myths... Misinformation or Truth

Agilent Cary 610/620 FTIR microscopes and imaging systems RESOLUTION FOR EVERY APPLICATION

8.0. High precision solutions for cleanliness analysis CLEMEX PSFILTER. Accurate measurement of particulates as small as 0.

Fourier Transform Infrared Spectrophotometer. IRAffinity-1 C103-E076D

Technical Procedure for Infrared Spectroscopy

SENTERRA II. Innovation with Integrity. The Next Level of Compact Raman Microscopy. Raman

Applications of Optics

SENTERRA II. Innovation with Integrity. The Next Level of Compact Raman Microscopy. Raman

Thermo Scientific Nicolet in10 FT-IR Microscope. Infrared microscopy. with confidence. intuitive innovative integrated

C103-E056C. Shimadzu Infrared Microscope

SIEVE CERTIFICATION SYSTEM

OPTICAL BACKSCATTER REFLECTOMETER TM (Model OBR 5T-50)

Mira M-3 Handheld Raman Spectrometer. On-site verification of materials in seconds

Measurement Method of High Absorbance (Low Transmittance) Samples by UH4150 INTRODUCTION

FTIR microscopy and imaging for failure analysis in electronics manufacturing

USER MANUAL FOR VISIBLE SPECTROPHOTOMETER

T92+ UV-VIS SPECTROPHOTOMETER

OPT3: Operating Procedure for Horiba Jobin Yvon LabRam Aramis Raman/PL System See LabSpec_6_2 General User Quick Start Guide on the computer desktop

Printing Quality Assurance

Croma Enterprise Cromtech India

Damage-free failure/defect analysis in electronics and semiconductor industries using micro-atr FTIR imaging

D U A L S T E P H E I G H T. Calibration Standards

8.0. High precision solutions for cleanliness analysis CLEMEX PSFILTER. Metallic and non-metallic particles analyzed in one step

UV / VIS Spectrophotometer EMCLAB Instruments GmbH

Agilent 8700 LDIR Chemical Imaging System. Bringing Clarity and Unprecedented Speed to Chemical Imaging.

Horiba Jobin-Yvon LabRam Raman Confocal Microscope (GERB 120)

Product Requirements Document: Automated Cosmetic Inspection Machine Optimax

instruments Analytical Instruments for Science

Spectroscopy Lab 2. Reading Your text books. Look under spectra, spectrometer, diffraction.

Understanding Optical Specifications

USB. Part No Wavelength range. Spectral bandwidth 5 nm 4 nm Optical system

SOP-P051. Scanning of Optical Filters With USB2000. Objective: To determine the spectral transmittance properties of an optical filter.

ECEN. Spectroscopy. Lab 8. copy. constituents HOMEWORK PR. Figure. 1. Layout of. of the

Quality assurance. OEM Custom Services. comaroptics.com

Figure 1 The Raith 150 TWO

Chroma. Optical Spectral Analysis and Color Measurement

December Fourier Transform and Apodization ABC of the FTIR Measurement Methods: Liquid Membrane Method Question --- 9

Measurement of Surface Profile and Layer Cross-section with Wide Field of View and High Precision

Marine Invertebrate Zoology Microscope Introduction

TRAINING MANUAL. Multiphoton Microscopy LSM 510 META-NLO

PHYS 202 OUTLINE FOR PART III LIGHT & OPTICS

Automated Double Aperture Accessory

Akinori Mitani and Geoff Weiner BGGN 266 Spring 2013 Non-linear optics final report. Introduction and Background

Guide to Operating the Bruker FT-IR Microscope I. Basic Spectrum Acquisition with Vertex 70

Horiba LabRAM ARAMIS Raman Spectrometer Revision /28/2016 Page 1 of 11. Horiba Jobin-Yvon LabRAM Aramis - Raman Spectrometer

UV / VIS Spectrophotometer

SSPC-PA 2 Procedure for Determining Conformance to Dry Coating Thickness Requirements

Georgia O'Keeffe. THE Alfred Stieglitz COLLECTION OBJECT RESEARCH Palladium print Alfred Stieglitz Collection. AIC accession number: 1949.

Thermography. White Paper: Understanding Infrared Camera Thermal Image Quality

THE ULTIMATE DOCUMENT EXAMINATION SYSTEM STATE-OF-THE-ART SPECTRAL ANALYSIS FORENSIC LABS SECURITY PRINTERS IMMIGRATION AUTHORITIES

MultiPrep Procedure. Backside Thinning of a Flip-Chip Device G. D. Liechty, C. A. Smith, Allied High Tech Products, Inc.

nanovea.com PROFILOMETERS 3D Non Contact Metrology

Automated Spectrophotometric Spatial Profiling of Coated Optical Wafers

Agilent 4500 Series FTIR. Operation Manual

UNIVERSITY OF WATERLOO Physics 360/460 Experiment #2 ATOMIC FORCE MICROSCOPY

CHAPTER-V SUMMARY AND CONCLUSIONS

Terahertz Spectroscopic/ Imaging Analysis Systems

Foreign Particulate Matter testing using the Morphologi G3

Identify extraneous chemicals that contributed towards the failure of actuating mechanism in inner vial

Reflectors vs. Refractors

Spectrum GX systems FT-IR SPECTROSCOPY.

YOUR INSTRUMENT YOUR SOLUTION

Be aware that there is no universal notation for the various quantities.

Point Spread Function Estimation Tool, Alpha Version. A Plugin for ImageJ

TriVista. Universal Raman Solution

DIRECT PART MARKING THE NEXT GENERATION OF DIRECT PART MARKING (DPM)

BLIPS perfectly aligned cleaned by any impurity Gently press the lens

Match the microscope structures given in the left column with the statements in the right column that identify or describe them.

Understanding Infrared Camera Thermal Image Quality

Educational Spectrophotometer Accessory Kit and System OS-8537 and OS-8539

Renishaw InVia Raman microscope

Characteristics and Applications of Imaging Microscope FT-IR. Teo Wei Boon PerkinElmer Singapore

International Journal of Pharma and Bio Sciences PROCESS ANALYTICAL TECHNOLOGY IMPLEMENTATION- PROGRESSION FOR A PHARMACEUTICAL INDUSTRY ABSTRACT

PT401 Paint Process Development and Infrared Reflectance Measurements

SURFACE ANALYSIS STUDY OF LASER MARKING OF ALUMINUM

Infra-Red Propagation Through Various Waveguide Inner Surface Geometries

Transcription:

C103-E119 Vol. 27 Validation of FTIR Systems ------- 02 Infrared Microscope Convenience of a Wide-View Camera ------- 06 AIM-9000 Infrared Microscope ------- 10

Validation of FTIR Systems Spectroscopy Business Unit, Analytical & Measuring Instruments Division Kiyoshi Wada Methods for validating FTIR systems were described in FTIR Talk Letter Vol. 4 (2006). In recent years, the pharmacopoeia of respective countries, which serve as the basis for the FTIR hardware validation methods, were revised. Therefore, this article discusses the effects of those revisions. First, however, a review of the article from FTIR Talk Letter Vol. 4 is provided below. The word "validate" can mean to legally "enable." When a parking ticket is stamped with a free parking stamp at the cash register after shopping at a department store, for example, we refer to that as "validating" the ticket. For instruments, we use "validation" to indicate that the instrument has been verified to function properly and is "safe and enabled for use." Consequently, it means that the instrument's validity has been verified and it is certified for use. As a result, the noun "validation" is now used to refer to the process of "verifying or confirming the appropriateness, suitability, or legal compliance" of an instrument. Actually, there are two types of instrument validation - hardware validation and software validation, but this article only addresses validation of FTIR hardware. 1. Hardware Validation FTIR hardware validation is the process of inspecting FTIR hardware to confirm that it is functioning properly. For FTIR systems, the instrument status is often revealed in the power spectrum. Therefore, one simple validation method is to check the shape and intensity of the power spectrum. In the case of Shimadzu FTIR systems, the shape and intensity of power spectra are checked as part of routine inspections. In addition, several public institutions have issued standards for methods used to inspect FTIR systems in more detail. For example, industrial standards have been specified by the Japanese Industrial Standards (JIS) and the American Society for Testing and Materials (ASTM), and pharmaceutical standards have been specified in the Japanese Pharmacopoeia (JP), European Pharmacopoeia (EP), United States Pharmacopeia (USP), and Chinese Pharmacopoeia (ChP). For FTIR hardware validation, rather than use JIS or ASTM methods, which do not clearly specify procedures for validating hardware intended for use in industry, Shimadzu uses procedures and standards specified for the pharmaceutical industry, which include clearly specified pharmacopoeia-based validation methods. Therefore, this article reviews the standards specified in the most recent country-specific pharmacopoeias. 2. Japanese Pharmacopoeia The 17th edition specifies requirements for instrument and adjustment under the section on Infrared Spectrophotometry in General Tests. It specifies procedures and criteria values for four inspection criteria resolution, wavenumber accuracy, wavenumber repeatability, and transmittance repeatability. 3. European Pharmacopoeia The European Pharmacopoeia 8th Edition specifies procedures and criteria values for two inspection criteria resolution and wavenumber accuracy in the "Control of resolution performance" and "Verification of the wavenumber scale" sections of "Absorption Spectrophotometry, Infrared." It does not include the repeatability criteria specified in the Japanese Pharmacopoeia. Up to the 4th Edition, the European Pharmacopoeia and Japanese Pharmacopoeia standards were the same, but starting with the 5th Edition, European Pharmacopoeia "resolution" standards for FTIR were based on absorbance and the "wavenumber accuracy" standards became ±1.0 cm -1 for all wavenumbers. 02 FTIR TALK LETTER Vol. 27

4. United States Pharmacopeia Until recently, the United States Pharmacopeia specified FTIR requirements under "851 Spectrophotometry and Light- Scattering", which specified referring to manufacturer instruction manuals for more specific FTIR system operating instructions. However, section 854, Mid-Infrared Spectroscopy, was added to the United States Pharmacopeia 38th Edition, released in 2015. That section includes wavenumber accuracy as an inspection criterion under "Qualification of IR Spectrophotometers," which specifies the same wavenumber and accuracy inspection requirements as the European Pharmacopoeia wavenumber accuracy requirements. Until May 2016, inspections based on 851 were permitted on an interim basis, but now inspections based on 854 are required. 6. Content of the Pharmacopoeia- Compliant Validation Program The following describes the validation program that is used in IRTracer-100/IRAffinity-1S systems and is compliant with all the pharmacopoeias. Instrument performance is inspected by comparing measurement results to criteria values, where inspection criteria include power spectrum, resolution, wavenumber accuracy, wavenumber repeatability, transmittance (absorbance) repeatability, and peak resolution function (only for Chinese Pharmacopoeia). The European Pharmacopoeia-compliant validation program is used for validation based on United States Pharmacopeia requirements. A polystyrene film about 0.04 mm thick (Japanese Pharmacopoeia) is used as the sample for validation. 5. Chinese Pharmacopoeia The Chinese Pharmacopoeia specifies procedures and criteria values for three inspection criteria resolution, wavenumber accuracy, and peak separation function, which are specified in the "Equipment and Calibration" section of "Appendix IV C Infrared Spectrophotometry." Of these inspection criteria, the Chinese Pharmacopoeia specifies validation at different wavenumbers for wavenumber accuracy than either the Japanese Pharmacopoeia, European Pharmacopoeia, or United States Pharmacopeia, and only the Chinese Pharmacopoeia specifies peak resolution function as an inspection criterion. Power Spectrum The most basic FTIR performance can be evaluated based on the power spectrum size. The program determines whether or not the power spectrum at a specified wavenumber is larger than the criterion value, where the sample is considered normal if the spectrum value is higher than the criteria value at all specified wavenumbers. Resolution Resolution is inspected as follows, based on an absorption spectrum measured from a polystyrene film about 0.04 mm thick. The difference between respective vertical axis values is determined and if both are greater than the criteria values, then it passes the inspection. Japanese Pharmacopoeia European Pharmacopoeia United States Pharmacopeia Chinese Pharmacopoeia Difference Between Minimum Vertical Axis Value Near 2870 cm -1 not less than 18 % greater than 0.33 Not specified not less than 18 % and Maximum Near 2850 cm -1 Difference Between Minimum Vertical Axis Value Near 1589 cm -1 not less than 12 % greater than 0.08 Not specified not less than 12 % and Maximum Near 1583 cm -1 Wavenumber Accuracy Wavenumber accuracy is inspected based on the wavenumbers of polystyrene spectrum peaks being within an allowable range. It passes the inspection if all specified peak wavenumbers are within the allowable range. Japanese Pharmacopoeia 3060.0 (±1.5) cm -1 2849.5 (±1.5) cm -1 1942.9 (±1.5) cm -1 1601.2 (±1.0) cm -1 1583.0 (±1.0) cm -1 1154.5 (±1.0) cm -1 1028.3 (±1.0) cm -1 European Pharmacopoeia United States Pharmacopeia 3060.0 (±1.0) cm -1 2849.5 (±1.0) cm -1 1942.9 (±1.0) cm -1 1601.2 (±1.0) cm -1 1583.0 (±1.0) cm -1 1154.5 (±1.0) cm -1 1028.3 (±1.0) cm -1 Chinese Pharmacopoeia 3027 (±1.5) cm -1 2851 (±1.5) cm -1 1601 (±1.0) cm -1 1028 (±1.0) cm -1 907 (±1.0) cm -1 FTIR TALK LETTER Vol. 27 03

Wavenumber Repeatability The Japanese Pharmacopoeia includes the following about wavenumber repeatability. As the repeatability of transmittance and wavenumber,..., when the spectrum of a polystyrene film is measured twice at several wavenumbers from 3000 to 1000 cm -1, and the difference of wavenumber should be within 5 cm -1 at about 3000 cm -1 and within 1 cm -1 at about 1000 cm -1. The program specifies three peak wavenumber points and determines the actual peak wavenumber at each point from two measurements of a polystyrene film. Then it decides whether or not the difference between the two measurements is within the allowable range. It passes the inspection if the peak wavenumbers at the specified wavenumber points are all within the allowable range. Though the European Pharmacopoeia, United States Pharmacopeia, and Chinese Pharmacopoeia do not specify wavenumber repeatability requirements, the program performs the inspection based on the Japanese Pharmacopoeia criteria. The program specifies three peak wavenumber points and determines the transmittance at each point from two measurements of a polystyrene film. Then it decides whether or not the difference between the two measurements is within the allowable range. It passes the inspection if the difference at each specified wavenumber point is within the allowable range. Note that transmittance (absorbance) repeatability requirements are not specified in the European Pharmacopoeia, United States Pharmacopeia, or Chinese Pharmacopoeia. The validation program for the Chinese Pharmacopoeia performs inspections based on the same standards as the Japanese Pharmacopoeia, whereas the validation program for the European Pharmacopoeia performs inspections based on absorbance standards. Japanese Pharmacopoeia Chinese Pharmacopoeia 3060.0 (±5) cm -1 1601.2 (±1) cm -1 1028.3 (±1) cm -1 Transmittance (Absorbance) Repeatability The Japanese Pharmacopoeia includes the following about transmittance repeatability. As the repeatability of transmittance and wavenumber, the difference of transmittance should be within 0.5 % when the spectrum of a polystyrene film is measured twice at several wavenumbers from 3000 to 1000 cm -1... European Pharmacopoeia Peak Resolution Function The Chinese Pharmacopoeia specifies that the resolution must resolve seven peaks within the wavenumber range of 3110 cm -1 to 2850 cm -1. The Chinese Pharmacopoeia does not specify a specific wavenumber for each peak, but the program inspection confirms that peaks are present within the following ranges, based on actual peak wavenumbers. Program Functionality 3102.63 (±5.0) cm -1 3082.38 (±5.0) cm -1 3060.20 (±5.0) cm -1 3025.48 (±5.0) cm -1 3001.37 (±5.0) cm -1 2921.32 (±5.0) cm -1 2849.95 (±5.0) cm -1 The validation program compliant with the Japanese Pharmacopoeia, European Pharmacopoeia, United States Pharmacopeia, and Chinese Pharmacopoeia are included standard in the LabSolutions IR software used to control IRTracer-100 and IRAffinity-1S systems. The program can be executed by simply selecting it on the LabSolutions IR launcher menu and operated by following the instructions displayed on the screen. Inspections can be performed fully automatically by using an external beam switching kit that includes a polystyrene film. When measurements are finished, it automatically prints a report with a summary of inspection results. Since inspections require only about five minutes, they can even be performed instead of routine inspections. Polystyrene Film Used for Inspections The polystyrene films included with Shimadzu FTIR systems can be used for inspections. However, if traceability is required, use an NIST (National Institute of Standards and Technology) SRM 1921b infrared transmission wavelength standard polystyrene film or other conforming secondary standard. SRM 1921b 25 mm diameter and approximately 38 μm thick polystyrene film samples are attached to a 5 11 cm paper holder. The provided certificate includes information about handling and storage methods, expiration date, and so on. Conforming secondary samples are available from companies such as International Crystal Laboratories (ICL). When not in use, cover the polystyrene film with the included cover and store it in a desiccator. Also, avoid touching the polystyrene film surface and blow off any dust with clean dry air. Needless to say, scratched or contaminated polystyrene film cannot be used. 3060.0 cm -1 : ±0.5% 1601.2 cm -1 : ±0.5% 1028.3 cm -1 : ±0.5% 3060.0 cm -1 : ±0.03 1601.2 cm -1 : ±0.05 1028.3 cm -1 : ±0.03 04 FTIR TALK LETTER Vol. 27

References Japanese Pharmacopoeia http://www.mhlw.go.jp/stf/seisakunitsuite/bunya/0000066597.html European Pharmacopoeia https://www.edqm.eu/ United States Pharmacopeia http://www.usp.org/ National Institute of Standards and Technology (NIST) https://www.nist.gov/ International Crystal Laboratories (ICL) http://www.internationalcrystal.net/home1.htm AIM-9000 Infrared Microscope FTIR TALK LETTER Vol. 27 05

Infrared Microscope Convenience of a Wide-View Camera Global Application Development Center, Analytical & Measuring Instruments Division Hirokazu Taniguchi Shimadzu has released the AIM-9000 infrared microscope as an automatic failure analysis system. The AIM-9000 includes a variety of new functionality that enables the series of steps involved in failure analysis to be performed quickly and easily. This article describes one of those new features, the wide-view camera, which can be used to view a broad area of the sample. 1. Introduction Using an infrared microscope to obtain an infrared spectrum from a tiny contaminant, for example, involves the following general steps. (1) Pretreat the sample, as necessary. (2) Place the item being measured on the infrared microscope stage and position it so that the target measurement location is within the field of view. (3) Select the location to be measured and specify the measurement range (aperture). (4) Measure the background and sample. Of those steps, one of the most time-consuming steps is step (2). It can be the most difficult step, particularly for those unfamiliar with operating an infrared microscope or those that use one infrequently. It was for that reason that the wide-view camera feature was developed. 2. Wide-View Camera With infrared cameras included in typical infrared microscopes, images are viewed via a reflecting objective mirror used for measuring infrared spectra, which provides an extremely narrow field of view only about a few hundred microns square. Consequently, it can take a long time to find the target item being measured. The new microscope includes both a conventional microscope camera and a wide-view camera that can show a large field of view. That means measurement targets can now be found more quickly. Fig. 1 shows the surface of an electronic circuit board viewed using the wide-view camera. In addition to enabling a macroscopic view size (10 13 mm), the wide-view camera also includes a zoom function that can magnify images by up to five times (2.0 2.6 mm). Fig. 2 shows the electronic part surface from Fig. 1 viewed via the high-magnification microscope camera. The microscope camera and wide-view camera share position information, so that users can switch smoothly between the cameras without the fields of view shifting out of alignment. Furthermore, the microscope camera includes a 10x zoom function (0.03 0.04 mm), which provides a total of about a 330x zoom capability. Fig. 1 Wide-View Camera Images Left: 10 13 mm Field-of-View Right: 2 2.6 mm Field-of-View (5x zoom) Fig. 2 Microscope Camera Images Left: 0.3 0.4 mm Field-of-View Right: 0.03 0.04 mm Field-of-View (10x zoom) 06 FTIR TALK LETTER Vol. 27

3. Example Using the Wide-View Camera The Japanese 10-yen coin is engraved with an image of the Phoenix Hall from the Byodoin Temple. If you have an infrared microscope, are you able to smoothly zoom in on one of the phoenixes on the roof of the Phoenix Hall, so that it remains in the field of view? Fig. 3 shows an image of a 10-yen coin placed on the stage. It was viewed using the microscope camera through the reflecting objective mirror (Cassegrain). The actual process involved moving the stage in X (left-right), Y (up-down), and Z (focus) directions, while also checking the position of light projected from the reflecting objective mirror and the degree of convergence. The target object does not appear in the field of view unless the stage is moved properly in the X, Y, and Z-directions. Fig. 5 Wide-View Camera Image of 10-Yen Coin (Before Adjusting Focus) After adjusting the focus, double-clicking on the center of the Phoenix Hall moves the point that was double-clicked to the center of the window, so that a sharp image of the Phoenix Hall is displayed as shown in Fig. 6. Fig. 3 10-Yen Coin Placed on the Stage and Viewed via the Reflecting Objective Mirror (Cassegrain) Next, the coin was viewed using the wide-view camera. Fig. 4 shows an image of the coin viewed via the wide-view camera. The stage is set to its lowest position and the focus is not adjusted. Fig. 5 shows the wide-view camera image in that state. It shows an approximate image of the design on the 10-yen coin. Fig. 6 Wide-View Camera Image of 10-Yen Coin (After Adjusting Focus) Double-clicking on a phoenix on the roof of the Phoenix Hall moves the phoenix to the center of the window. If the digital zoom function is used, even the approximate shape of the phoenix becomes visible, as shown in Fig. 7. Fig. 4 Viewing the 10-Yen Coin Placed on the Stage via the Wide-View Camera Fig. 7 Magnified Image of Phoenix Using Wide-View Camera FTIR TALK LETTER Vol. 27 07

Double-clicking the head of the phoenix moves it to the center of the window, and the field of view is switched from the wide-view camera to the reflecting objective mirror (microscope camera). Because the wide-view camera shares its position information with the microscope camera, the field of view switches smoothly from wide-view to microscope without moving out of alignment. The upper image in Fig. 8 shows the image displayed immediately after switching to the microscope camera. By slightly adjusting the focus, a sharp image of the phoenix head area can be obtained, as shown in the lower image in Fig. 8. (2) (3) (1) Fig. 9 Image of Metal Plate Surface Viewed via Wide-View Camera By double-clicking in the window to further zoom in and focus on adhesion (1) shown in Fig. 9, a clear image of the overall shape of the adhesion can be confirmed, as shown in Fig. 10. Fig. 10 Magnified Image of Adhesion Using Wide-View Camera Fig. 8 Microscope Camera Image of the Phoenix Head Upper: Before Focusing Lower: After Focusing 4. Example of Analysis Using Wide-View Camera Next, the field of view is switched from the wide-view camera to the microscope camera. Even if the image is slightly out of focus, the target item always remains within the field of view of the microscope camera, which eliminates any need to move the stage in X or Y direction. Therefore, only the focus needs to be adjusted to obtain a reliable clear image of the adhesion, as shown in Fig. 11. By specifying a background measurement range (yellow square) and sample measurement range (red square), the reflection method was used to measure the IR spectrum of the adhesion. In this example, the aperture size was set to 30 30 μm and the number of scans was set to 40. The spectrum obtained is shown in Fig. 12. The following is an example of analyzing a brown substance adhered to a metal plate. Fig. 9 is an image of a metal plate surface viewed via the wide-view camera. It shows several dots of a brown substance adhered to the surface, spaced a few millimeters apart. The capture function can be used to hold the image in a fixed position in the software window. Fig. 11 Specifying the Measurement Range in the Microscope Camera Image of Adhesion (1) 08 FTIR TALK LETTER Vol. 27

Abs 1.0 0.5 Adhesion (1) Adhesion (1) 1.0 Adhesion (2) Adhesion (3) Abs 0.5 4000 3000 2000 1500 1000 cm -1 4000 3000 2000 1500 1000 cm -1 Fig. 12 Infrared Spectrum of Adhesion (1) Sodium Carboxymethyl Cellulose Then the captured wide-view camera image, shown in the upper image of Fig. 13, can be used for measuring adhesion (2) next. Double-clicking on adhesion (2) positions adhesion (2) within the microscope camera field of view. Then the measurement process can be started smoothly by simply fine-focusing the image, as shown in the lower image of Fig. 13. (2) 4000 3000 2000 1500 1000 cm -1 Fig. 14 Overlay of Infrared Spectra from Three Adhesions (Upper) and Library Spectrum of Sodium Carboxymethyl Cellulose (Lower) (3) (1) 5. Conclusion The wide-view camera was developed to minimize the burden on those without significant experience operating an infrared microscope, but when highly experienced operators at Shimadzu used the wide-view camera, even they definitely appreciated its convenience. Consequently, it has dramatically increased the productivity of contract analysis work and customer-attended analysis work that Shimadzu performs for customers. We would be grateful if customers were given the opportunity to experience the new infrared microscope as well. Fig. 13 Captured Wide-View Camera Image (Upper) and Microscope Camera Image of Adhesion (2) (Lower) By following the above steps, spectra from the three adhesions can be obtained smoothly. An overlay of the measurement results from the three adhesions is shown in the upper graph of Fig. 14. It shows that the spectra from the three adhesions are very similar. Spectrum search results indicate that the adhesions are similar to sodium carboxymethyl cellulose, shown in the lower graph of Fig. 14. Due to publication space limitations, the Q&A section has been omitted in this issue. FTIR TALK LETTER Vol. 27 09

Infrared Microscope AIM-9000 Wide-Field Camera Automatic Contaminant Recognition Automatic Qualitative Analysis High Sensitivity Finally, a wide view on micro sample analysis Contaminant Analysis Surface Analysis Micro Analysis SHIMADZU AIMs to provide analysis systems for all users. IRTracer-100 +AIM-9000 The system is automated to ensure all steps involved in micro analysis can be performed quickly and easily. All our accumulated know-how in micro analysis is concentrated in the AIM-9000 to strongly support analysts. Three steps for micro analysis Observe Measure Analyze Visible 330 digital zoom Automatic contaminant recognition system Contaminant analysis program IRAffinity-1S +AIM-9000 Shimadzu Corporation, 2017 First Edition: November 2017