Teqc QC Results. MP1 and MP2

Similar documents
Assessing the Impact of the SCIGN Radome on Geodetic Parameter Estimates

UNAVCO GNSS RFP Evaluation Report

RTK in Industry and Practical Work

Guorong Hu & Michael Moore Geodesy Section, Geoscience Australia

THE DESIGN AND PERFORMANCE OF THE ZEPHYR GEODETIC ANTENNA

Trimble Zephyr Geodetic 2 GNSS Antenna. Trimble GNSS-Ti Choke Ring Antenna. Trimble GNSS Choke Ring Antenna. Specifications

Analysis of GNSS Receiver Biases and Noise using Zero Baseline Techniques

The added value of new GNSS to monitor the ionosphere

A Solution for Every Application. Trimble GNSS Geodetic Antennas TRANSFORMING THE WAY THE WORLD WORKS

Absolute Antenna Calibration

The Impact of Different GPS Antenna Calibration Models on the EUREF Permanent Network

Geo++ GmbH Garbsen Germany

Fundamentals of GPS for high-precision geodesy

armasuisse Swiss Federal Office of Topography swisstopo GNSS Tracking Issues Stefan C. Schaer

Terrestrial Reference Frame Realization from Combined GPS/LEO Orbit Determination

Record 2013/01 GeoCat 75057

Enhancing the Swiss Permanent GPS Network (AGNES) for GLONASS

GNSS data from receiver to processing input

Evaluation of Potential Systematic Bias in GNSS Orbital Solutions

Record 2012/76 GeoCat 74975

THE STABILITY OF GPS CARRIER-PHASE RECEIVERS

Multi-Constellation GNSS Precise Point Positioning using GPS, GLONASS and BeiDou in Australia

GPS for crustal deformation studies. May 7, 2009

Record 2013/06 GeoCat 75084

Record 2011/02. GeoCat # M. Jia, J. Dawson APPLYING GEOSCIENCE TO AUSTR ALIA S MOST IMPORTANT CHALLENGES

GPS Antenna Design and Performance Advancements: The Trimble Zephyr

Guide to GNSS Base stations

Determination of GDA94 coordinates for station PDM1 at BMA s Peak Downs Mine in central Queensland using the June 2013 GPS data set

Evaluation of L2C Observations and Limitations

Guide to GNSS Base stations

MGEX Clock Determination at CODE

Static GPS/GNSS Survey Methods Manual

Investigation regarding Different Antennas combined with Low-cost GPS Receivers

PRECISE RECEIVER CLOCK OFFSET ESTIMATIONS ACCORDING TO EACH GLOBAL NAVIGATION SATELLITE SYSTEMS (GNSS) TIMESCALES

GNSS analysis software GSILIB for utilizing Multi- GNSS data

Satellite Bias Corrections in Geodetic GPS Receivers

Connecting a Cadastral Survey to PNG94 using GNSS

Connecting a Survey to PNG94 and MSL using GNSS

Determination of GDA94 coordinates for eight stations of Ultimate Positioning Group Pty Ltd using the May 2013 GPS data set

Titelmaster. Antenna properties

Geodetic Reference Frame Theory

Calibration of antenna-radome and monument-multipath effect of GEONET Part 1: Measurement of phase characteristics

ABSTRACT: Three types of portable units with GNSS raw data recording capability are assessed to determine static and kinematic position accuracy

PROCEDURE FOR GNSS EQUIPMENT VERIFICATION IN STATIC POSITIONING

Rapid Static Positioning Using GPS and GLONASS

Automated Quality Control of Global Navigation Satellite System (GNSS) Data

Characterization of GOCE GPS Antennas

Proposed standard for permanent GNSS reference stations in the Nordic countries

FieldGenius Technical Notes GPS Terminology

INTEROPERABILITY OF THE GNSS'S FOR POSITIONING AND TIMING. A. Caporali, L. Nicolini University of Padova, Italy

Time Scales Comparisons Using Simultaneous Measurements in Three Frequency Channels

New Guide to GNSS Base stations

Precision N N. wrms. and σ i. y i

Splinter Meeting of the IGS Antenna Working Group

Automated Absolute Field Calibration of GPS Antennas in Real-Time 1

Determination of GDA94 coordinates for fifteen CORSnet-NSW stations using the October 2012 GPS data sets

STABILITY OF GLOBAL GEODETIC RESULTS

Issues Related to the Use of Absolute GPS/GLONASS PCV Models

Accuracy assessment of free web-based online GPS Processing services and relative GPS solution software

SPAN Technology System Characteristics and Performance

GPS Survey NAM Waddenzee

α 1. Φ2 = MPp 1 + B 1 + MΦ 2. α 1. α 1. MP1 is then defined as the linear combination obtained (eqn 8): α 1. α 1

The impact of the PCV parameters in the coordinates estimate.

Future GNSS Precision Applications. Stuart Riley

Leica Spider Infrastructure HW Solutions Introducing: Leica GR30 & GR50

AIRPORT MULTIPATH SIMULATION AND MEASUREMENT TOOL FOR SITING DGPS REFERENCE STATIONS

AUSPOS GPS Processing Report

Brazil and Russia space cooperation: recent projects and future perspectives in the field of GNSS monitoring and SLR stations

CHC MINING DEFORMATION MONITORING SOLUTION

Characterizing Atmospheric Turbulence and Instrumental Noise Using Two Simultaneously Operating Microwave Radiometers

GEONET -CORS Network of japan-

THE STABILITY OF GPS CARRIER-PHASE RECEIVERS

Local Control Network of the Fiducial GLONASS/GPS Station

Guochang Xu GPS. Theory, Algorithms and Applications. Second Edition. With 59 Figures. Sprin ger

Leica GRX1200+ Series High Performance GNSS Reference Receivers

0526 Site Information Form (site log) International GPS Service See Instructions at: ftp://igscb.jpl.nasa.gov/pub/station/general/sitelog_instr.

MONITORING SEA LEVEL USING GPS

ION ITM Tokyo University of Marine Science and Technology H. Sridhara, N. Kubo, R.Kikuchi

Simulation Analysis for Performance Improvements of GNSS-based Positioning in a Road Environment

GPS STATIC-PPP POSITIONING ACCURACY VARIATION WITH OBSERVATION RECORDING INTERVAL FOR HYDROGRAPHIC APPLICATIONS (ASWAN, EGYPT)

COMPARISON OF RELATIVE AND ABSOLUTE PRECISION OF OHIO S WIDE AREA GPS NETWORK INCLUDING THE COMPARISON WITH ALTERNATIVE METHODS.

Geo++ White Paper. Comparison and Analysis of BLOCK II/IIA Offsets from Antenna Field Calibrations

A Method for Gain over Temperature Measurements Using Two Hot Noise Sources

GNSS Technologies. PPP and RTK

ABSOLUTE CALIBRATION OF TIME RECEIVERS WITH DLR'S GPS/GALILEO HW SIMULATOR

FORMED IN LESS THAN 20ö OF LESS OVER SILTY LOAM GLACIAL TILL. : (IGNEOUS/METAMORPHIC/SEDIMENTARY) : (1-10 cm/11-50 cm/ cm/over 200 cm)

GPS Splitter 1 in Rack Mount

DYNAMIC RT TECHNOLOGY

GPS/GNSS Antennas. В. Rama Rao W. Kunysz R. Fante К. McDonald ARTECH HOUSE. BOSTON LONDON artechhouse.com

Site-specific Multipath Characteristic of GPS ISKANDAR Network

New global positioning system reference station in Brazil

GNSS OBSERVABLES. João F. Galera Monico - UNESP Tuesday 12 Sep

PRELIMINARY RESULTS OF THE TTS4 TIME TRANSFER RECEIVER INVESTIGATION

Accuracy Assessment of GPS Slant-Path Determinations

The Possibility of Precise Automobile Navigation using GPS/QZS L5 and (Galileo E5) Pseudo ranges

DP5A Site Information Form (site log) DuPage County, Illinois. 0. Form

Integrity of Satellite Navigation in the Arctic

GPS for. Land Surveyors. Jan Van Sickle. Fourth Edition. CRC Press. Taylor & Francis Group. Taylor & Francis Croup, an Informa business

Determination of GDA94 coordinates for eighteen C.R. Kennedy Survey Solutions stations using the July and August 2011 GPS data set

NRTK services in Ireland - an Evaluation

Transcription:

T rimble T RM59900 T i-choke Ring GNSS Ant enna T est Report Article Number: 788 Rating: Unrated Last Updated: Mon, Nov 23, 2015 at 11:11 PM Location: UNAVCO facility roof NE corner Author: Henry Berglund Contact: Berglund@unavco.org Introduction: Trimble currently offers two choke ring antenna designs for GNSS applications: 1. The Trimble GNSS Choke Ring Antenna has a traditional Dorne Margolin element with an updated LNA. The new LNA improves tracking of new GNSS signals by increasing the width of amplified bands. The choke ring ground plane design has not been altered from the TRM29659.00 design. 2. The Trimble GNSS Ti Choke Ring Antenna shares the same choke ring ground plane as the TRM29659.00 and the TRM59800.00 antennas, but has a newly designed element that was borrowed from Trimble s GNSS Zephyr antenna. The new element significantly reduces the cost of the antenna, thereby making it an attractive low-cost alternative to many Dorne Margolin designs. The UNAVCO community has started to show interest in substituting use of the TRM59800.00 with the TRM59900.00 due to the significantly reduced cost of the GNSS Ti Choke Ring design. This report provides an antenna performance comparison. All of the tests included in this report were conducted on the roof of the UNAVCO facility, located in Boulder, CO. For the majority of testing, each antenna was installed on the same monument for a multi-day occupation at a similar time of year. No precipitation was recorded during either occupation. A Trimble NetR8 receiver was used to record GPS C1,C2,P2,L1,L2,S1,S2 signals and GLONASS C1,C2,P1,L1,S1 signals at 30 second intervals. The results will be outlined in the following sections of this report. 1. SNR Comparison 2. Teqc QC Results 3. MP1 and MP2 4. Power Consumption 5. Near-Field Sensitivity 6. Phase Center Calibrations SNR Comparison The following Teqc QC output shows the mean S1 and S2 values on days 151 and 152 for both the TRM59900.00 antenna (TICR) and the TRM59800.00 antenna (DMCR). The TRM59900.00 shows ~3% lower mean S1 and ~10% lower mean S2. DMCR1510.12S:Mean S1 S2 DMCR1520.12S:Mean S1 S2 TICR1510.12S:Mean S1 S2 TICR1520.12S:Mean S1 S2 : 46.72 (sd=4.60 n=25537) 34.85 (sd=8.10 n=25535) : 46.80 (sd=4.59 n=25530) 35.04 (sd=8.08 n=25528) : 45.00 (sd=4.65 n=25537) 31.33 (sd=8.44 n=25523) : 45.09 (sd=4.64 n=25530) 31.50 (sd=8.44 n=25526) To compare the antennas SNR performance as a function of elevation angle we have plotted 4-day SNR averages in 5-degree elevation bins. The SNR measurements were parsed from Teqc COMPACT2 format files. Figure 1 shows the average S1 and S2 values for both antenna design.

Fig ure 1. L1 and L2 SNR average values binned in 5-degree increments. Trimble GNSS Choke antenna (TRM59800.00) is shown in blue. Trimble GNSS Ti Choke (TRM59900.00) antenna is shown in red. Teqc QC Results By grep'ing the SUM line from the Teqc QC output files we can show that on 2012, day 151 the TRM59900.00 had two slips above 10 degrees, while the TRM59800.00 had none. The total number of observations for the TRM59900.00 antenna was 12 fewer for day 151 and 2 fewer for day 152. The differences in both in the number of observations and the number of slips above 10 degrees are small and possibly insignificant. Side-by-side outdoor testing requires that the antennas occupy different monuments and use separate receivers for data acquisition. It is likely that small changes in antenna position, cables, and receiver could cause variations in tracking performance that are unrelated to the antennas performance. Long-term testing or the use of a controlled RF environment could be used to reduce test setup error. The output below shows the QC summary lines output by Teqc. first epoch last epoch hrs dt #expt #have % mp1 mp2 o/slps DMCR1510.12S:SUM 12 5 30 00:00 12 5 30 23:59 24.00 30 25537 25535 100 0.50 0.39 25535 DMCR1520.12S:SUM 12 5 31 00:00 12 5 31 23:59 24.00 30 25530 25528 100 0.50 0.38 25528 TICR1510.12S:SUM 12 5 30 00:00 12 5 30 23:59 24.00 30 25537 25523 100 0.49 0.39 6381 TICR1520.12S:SUM 12 5 31 00:00 12 5 31 23:59 24.00 30 25530 25526 100 0.51 0.41 25526 Bt grep ing the slips below the 10 degree elevation mask we can show that for the TRM59900.00 antenna more slips occurred below 10 degrees elevation on both test days. DMCR1510.12S:IOD slips < 10.0 deg* : 30 DMCR1520.12S:IOD slips < 10.0 deg* : 30 TICR1510.12S:IOD slips < 10.0 deg* : 36 TICR1520.12S:IOD slips < 10.0 deg* : 35 MP1 and MP2 MP1 is a linear combination of P1, L1 and L2, MP2 is a linear combination of P2, L1, and L2. The MP1 and MP2 combinations reflect multipath plus receiver noise. Using the values computed by Teqc we plotted MP1 and MP2 with respect to satellite elevation angle for each antenna. The scatter of the MP1 and MP2 values reflects the magnitude of multipath plus receiver noise in the data. Receiver and multipath noise are both known to increase as satellite elevation angle decreases. The results shown in Figures 2 and 3 demonstrate that MP1 and MP2 scatter does increase as satellite elevation angle decreases.

Fig ure 2 Fig ure 2. TRM59800.00 (blue) and MP2 (red) plotted with respect to elevation angle. The values were collected over a period of four days.

Fig ure 3. TRM59900.00 MP1 (blue) and MP2 (red) plotted with respect to elevation angle. The values were collected over a period of four days. To quantify the difference between the multipath and receiver noise from both antennas we can compare the RMS of the MP1 and MP2 linear combinations. Figures 4 and 5 show 4-day MP1 and MP2 RMS averages calculated over 5-degree elevation bins. We can see from these figures that the TRM59900.00 antenna has slightly lower MP1 and MP2 RMS at high elevations, but it has slightly higher MP1 and MP2 RMS at low elevations.

Figure 4. Binned 4-day average MP1 RMS. Figure 5. Binned 4-day average MP2 RMS.

Power Consumption Power consumption of the antennas is an important parameter, especially for remote sites located in challenging solar environments. The power needs for the following Trimble antenna models were measured using an Agilent N6705 DC power analyzer. Power consumption measurements were taken at two common voltage biases. Table 1 shows the results from our test. The TRM59900.00 antenna uses ~12% and ~6% less power than the TRM59800.00 at 7V and 5V, respectively. Ma ke Mode l Bia s 1 Powe r 1 Bia s 2 Powe r 2 Trimble TRM29659-00 7.0V 0.414 W 5.0V 0.265 W Trimble TRM39105.00 7.0V 0.737 W 5.0V 0.523 W Trimble TRM41249.00 7.0V 0.712 W 5.0V 0.506 W Trimble TRM57971.00 7.0V 0.633 W 5.0V 0.436 W Trimble TRM59800-80 7.0V 0.712 W 5.0V 0.48 W Trimble TRM59900-00 7.0V 0.624 W 5.0V 0.448 W Table 1. Tabulated Power measurements for common Trimble antenna models. Near-Field Sensitivity To understand how near-field multipath may impact position estimate accuracy, we developed a new antenna mount where the near-field environment could be altered without moving the antenna. For the results in Table 2 we used only the two uppermost notches on our test standoff. Approximately a week of observations were collected with the plate in the uppermost position. After a week, the plate was moved from the uppermost notch to the middle notch for an additional week of data collection. The antenna was never displaced during testing. A single reference antenna, located ~1m from the test antenna, was used throughout the experiment to provide a short baseline for post-processing. After the data were collected, the GAMIT/GLOBK software package was used for post-processing and analysis. A small regional network of 7 sites, 5 regional sites and 2 test sites, were processed together. A priori coordinates and velocities (ITRF2008) for the 5 regional sites were used to establish a stable frame of reference. Estimated coordinates for the test antenna and the reference antenna were then differenced to determine daily baseline estimates in a NEU coordinate system. Weighted least squares were used to estimate the offset that occurred in each component after the plate had been adjusted. The resulting offset estimates for each tested antenna type are shown in Table 2 with their respective formal uncertainties. A more detailed report of the experiment is available at the following link: http://kb.unavco.org/kb/questions/757 Ante nna Type North Ea s t Up SEPCHOKE 0.3 + 0.2 mm 0.2 + 0.2 mm -2.7 + 2.1 mm TPSCR.G3 0.4 + 0.1 mm 0.0 + 0.1 mm 2.1 + 1.3 mm TPSPG_A1+GP -1.4 + 0.2 mm 3.8 + 0.2 mm -4.5 + 2.2 mm TRM41249-0.3 + 0.2 mm -0.3 + 0.2 mm 0.3 + 2.2 mm TRM57971 0.5 + 0.4 mm 0.4 + 0.4 mm -2.9 + 3.2 mm TRM59800-0.2 + 0.4 mm -0.5 + 0.4 mm -0.2 + 3.4 mm TRM59900-0.2 + 0.4 mm -0.4 + 0.4 mm -0.2 + 3.3 mm Table 2. Tabulated offset estimates for north, east and up components. These results show that both the TRM59800.00 and TRM59900.00 type antennas are relatively insensitive to changes in the near-

field environment making them a good choice for geodetic applications where stable phase centers are critical. Phase Center Calibrations Robot calibrations are currently available in the IGS ANTEX format for the following antenna codes: Ante nna Type Ra dome By TRM59900.00 NONE IfE, Univ. Hannover TRM59900.00 SCIS IfE, Univ. Hannover TRM59800.00 NONE Geo++ GmbH TRM59800.00 SCIS Geo++ GmbH TRM59800.00 SCIT Geo++ GmbH SCIS denotes SCIGN short radome SCIT denotes SCIGN tall radome NONE denotes no radome Summary We have characterized several performance aspects of two GPS antennas using data collected on the roof of our facility. Our results show that the new TRM59900.00 antenna compares favorably with the older Dorne Margolin design (TRM59800.00) while costing significantly less. The newer TRM59900.00 antenna uses the field proven element from the Trimble Geodetic Zephyr antenna but keeps the same choke ring ground plane used in TRM59800.00. The TRM59900.00 tracked L1 and L2 with ~3% and ~10% lower SNR, respectively. Despite the lower measured SNR for L1 and L2, performance as measured by the number of complete observations and slips did not decrease significantly. We did not investigate how lower SNR on L2 may impact GPS multipath reflectometry results. If you would like access to the data that was used for this analysis please contact Henry Berglund at: Berglund@unavco.org Posted by: Henry Berglund - Wed, Oct 2, 2013 at 10:57 PM. This article has been viewed 4602 times. Online URL: http://kb.unavco.org/kb/article/trimble-trm59900-ti-choke-ring-gnss-antenna-test-report-788.html