Agilent N6700 Modular Power System Family

Similar documents
Agilent N6700 Modular Power System Family

Keysight N6700 Modular Power System Family

Agilent DC Power Analyzer

Agilent DC Power Analyzer

Agilent N6780 Series Source/Measure Units (SMUs) for the N6700 Modular Power System

Keysight Advanced Power System N6900/N7900 Series

Agilent N6780 Series Source/Measure Units (SMUs) for the N6700 Modular Power System

Keysight 86205B RF Bridge

Keysight N6780 Series Source/Measure Units (SMUs) for the N6700 Modular Power System

Agilent 8494/95/96A/B Attenuators

Keysight N2771B 30 kv High Voltage Probe

Agilent N8700 Series System DC Power Supplies

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

Agilent N3300 Series DC Electronic Loads

Agilent dc Electronic Loads Models N3300A-N3307A

Keysight 8494/95/96G/H Attenuators

Keysight U2701A/U2702A USB Modular Oscilloscope

Photovoltaic / Solar Array Simulation Solution

Agilent U1211A, U1212A, and U1213A Clamp Meter. Quick Start Guide U1211A U1212A U1213A

Keysight 2-Port and 4-Port PNA-X Network Analyzer

PXIe Contents. Required Software CALIBRATION PROCEDURE

PXIe, 24-Channel, ±24 V, 50 ma Precision PXI Source Measure Unit

Advanced Test Equipment Rentals ATEC (2832)

z475 Remote DC Power Supply Preliminary

5500A. Multi-Product Calibrator. Extended Specifications 2005

Power Amplifier. Input Characteristics. SPECIFICATIONS NI PXIe-4610 Power Amplifier. Signal Range

PXI Contents SPECIFICATIONS. ±20 V, 40 W PXI Source Measure Unit

PXI Contents. Definitions SPECIFICATIONS. ±100 V, 2 W Precision PXI Source Measure Unit. These specifications apply to the PXI-4132.

Keysight Technologies N8700 Series System DC Power Supplies

Contents. Software Requirements

NI PXI-2521 Specifications 40-Channel DPST Relay Module

American Power Design, Inc.

American Power Design, Inc.

NI PXI-2520 Specifications 80-Channel SPST Relay Module

5520A. Multi-Product Calibrator. Extended Specifications 2005

SERVICE MANUAL. GPIB DC Power Supplies Agilent Series 654xA, 655xA, 664xA, 665xA. For instruments with Serial Numbers:

High Stability Voltage Source

Keysight U9397A/C FET Solid State Switch (SPDT)

2520 Pulsed Laser Diode Test System

5520A. Multi-Product Calibrator. Extended Specifications

TETRIS 1000 High Impedance Active Probe. Instruction Manual

2302 Battery Simulator 2306, 2306-PJ Battery/Charger Simulators

Operator s Manual. PP016 Passive Probe

100 MHz Bandwidth, 12-Bit PXI Waveform Generator

NI PXI Contents DEVICE SPECIFICATIONS. RF Attenuator

Power MOSFET FEATURES. IRFIB6N60APbF SiHFIB6N60A-E3 IRFIB6N60A SiHFIB6N60A

PKT 512A-RO High Impedance Passive Cable Divider

Ultra low quiescent current, Fast Load Transient 300 ma CMOS Low Drop-Out Regulator in ultra small package

Agilent N7509A Waveform Generation Toolbox Application Program

Current ON state current ma minimum, 6 ma typical, 10 ma maximum OFF state current ma maximum

High Voltage Glass Passivated Junction Plastic Rectifier

PXIe Contents. Required Software CALIBRATION PROCEDURE

Agilent Technologies. E8257D/67D, E8663D PSG Signal Generators. Key Reference. Agilent Technologies

SA5.0A thru SA170CA. TRANSZORB Transient Voltage Suppressors. Vishay General Semiconductor. FEATURES PRIMARY CHARACTERISTICS

Keysight Spectrum Analyzer Option (090/S93090xA) for PNA/PNA-L/PNA-X/N5290A/N5291A

SCXI MHz Quad 8x1 50 Ω Multiplexer

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Agilent Technologies 8114A 100 V/2 A Programmable Pulse Generator

High Current Density Surface Mount Glass Passivated Rectifiers

TOSHIBA Bipolar Linear Integrated Circuit Silicon Monolithic TAR5SB15 ~ TAR5SB50

Power MOSFET FEATURES. IRLZ44PbF SiHLZ44-E3 IRLZ44 SiHLZ44 T C = 25 C

SA5.0A thru SA170CA. TRANSZORB Transient Voltage Suppressors. Vishay General Semiconductor. FEATURES PRIMARY CHARACTERISTICS

NI PXIe Contents. Required Software CALIBRATION PROCEDURE. Dual-Output Programmable DC Power Supply

TETRIS User's Guide. High Impedance Active Probe DO177-1

E36300 Series Programmable DC Power Supplies. Service Guide

Battery Simulator Battery/Charger Simulators

NI PXIe Contents CALIBRATION PROCEDURE. Single-Channel Precision Source-Measure Unit (SMU)

High Current Density Surface Mount Dual Common Cathode Schottky Rectifiers

Bipolar Output Working Standard

InfiniiMax Spice Models for the N5381A and N5382A Probe Heads

TOSHIBA Bipolar Linear Integrated Circuit Silicon Monolithic TAR5S15U ~ TAR5S50U

Four-quadrant fast response bi-polar power supply

American Power Design, Inc.

4-Channel, ±24 V, 150 ma PXI Source Measure Unit

4-Channel, ±6 V, 500 ma Precision PXI Source Measure Unit

PXIe Contents SPECIFICATIONS. RF Amplifier

Agilent E3633A and E3634A DC Power Supplies

New Product. High Temperature Stability and High Reliability Conditions FEATURES

NI PXIe-5601 Specifications

Single Phase Rectifier Bridge, 1.2 A

Advanced Test Equipment Rentals ATEC (2832)

Declaration of Conformity to the DeviceNet Specification

Keysight N2790A Differential Voltage Probe. User Guide

4-Channel ±10 V, 100 ma, Precision PXI Source Measure Unit

Keysight Series 654xA, 655xA, 664xA, 665xA GPIB DC Power Supplies

System and Bench Instruments Catalog 2005 Detailed Specifications, Application Briefs and more for:

4-Channel, ±24 V, 150 ma Precision PXI Source Measure Unit

Keysight N4985A System Amplifiers

General Purpose Plastic Rectifier

Single Phase Rectifier Bridge, 1.9 A

INTEGRATED CIRCUITS DATA SHEET. TDA7056A 3 W BTL mono audio output amplifier with DC volume control

High Current Density Surface Mount Dual Common-Cathode Schottky Rectifier

Keysight 2-Port and 4-Port Broadband Network Analyzer

INSTRUCTIONS MODELS AVX-TRR-SQMELF TEST JIG FOR USE WITH AVTECH AVR-EB4-B REVERSE RECOVERY TEST SYSTEMS SERIAL NUMBER:

Description. Table 1. Device summary. Order code Package Packing. TDA7851F Flexiwatt25 (vertical) Tube TDA7851FH-QIX Flexiwatt25 (horizontal) Tube

Keysight 2-Port and 4-Port PNA-X Network Analyzer

Advanced Test Equipment Rentals ATEC (2832)

NI PXIe Contents CALIBRATION PROCEDURE. Four Channel Precision Source-Measure Unit (SMU)

User Guide. Keysight N6850A Broadband Omnidirectional Antenna

Fast Switching Plastic Rectifier

Transcription:

Agilent N67 Modular Power System Family N6731B-N6784A DC Power Modules Specifications Guide

Legal Notices Agilent Technologies, Inc. 21-212 No part of this document may be photocopied, reproduced, or translated to another language without the prior agreement and written consent of Agilent Technologies, Inc. as governed by United States and international copyright laws. Warranty The material contained in this document is provided as is, and is subject to being changed, without notice, in future editions. Further, to the maximum extent permitted by applicable law, Agilent disclaims all warranties, either express or implied, with regard to this manual and any information contained herein, including but not limited to the implied warranties of merchantability and fitness for a particular purpose. Agilent shall not be liable for errors or for incidental or consequential damages in connection with the furnishing, use, or performance of this document or of any information contained herein. Should Agilent and the user have a separate written agreement with warranty terms covering the material in this document that conflict with these terms, the warranty terms in the separate agreement shall control. Manual Editions Manual Part Number: N67-91 Sixth Edition, February 212 Available in electronic format only. Updates of this manual containing minor corrections may have the same edition date. Revised editions are identified by a new edition date. Certification Agilent Technologies certifies that this product met its published specifications at time of shipment from the factory. Agilent Technologies further certifies that its calibration measurements are traceable to the United States National Institute of Standards and Technology, to the extent allowed by the Institute's calibration facility, and to the calibration facilities of other International Standards Organization members. Technologies Licenses The hardware and or software described in this document are furnished under a license and may be used or copied only in accordance with the terms of such license. U.S. Government Restricted Rights Software and technical data rights granted to the federal government include only those rights customarily provided to end user customers. Agilent provides this customary commercial license in Software and technical data pursuant to FAR 12.211 (Technical Data) and 12.212 (Computer Software) and, for the Department of Defense, DFARS 252.227-715 (Technical Data Commercial Items) and DFARS 227.722-3 (Rights in Commercial Computer Software or Computer Software Documentation). Declaration of Conformity Declarations of Conformity for this product and for other Agilent products may be downloaded from the Web. Go to http://regulations.corporate.agilent.com and click on Declarations of Conformity. You can then search by product number to find the latest Declaration of Conformity. Regulatory Symbols The CE mark shows that the product complies with all applicable European Directives. The C-Tick mark is a registered trademark of the Australian Communications Authority. This ISM device complies with Canadian ICES-1. Cet appareil ISM est conforme à la norme NMB-1 du Canada. This is the symbol for an Industrial, Scientific and Medical, Group 1 Class A product. The CSA mark is a registered trademark of Intertek-etlsemko Inc. This is the RoHS (Restriction of Hazardous Substances) symbol for electrical and electronic equipment. This symbol indicates separate collection for electrical and electronic equipment mandated under EU law as of August 13, 25. All electric and electronic equipment are required to be separated from normal waste for disposal (Reference WEEE Directive 22/96/EC). 2 N6731B-N6784A DC Power Modules Specifications Guide

Where to Find More Information This document provides specification and supplemental characteristic information for the following instruments: Agilent N6731B through N6784A Power Modules Agilent N67B through N675B Mainframes For additional technical details and ordering information for the Agilent N67 Modular Power System Family, refer to the following: Document Agilent N67 Modular Power System Family: Low-Profile MPS Mainframe for Automated Test Environments Agilent N67 Modular Power System Family: DC Power Analyzer Mainframe for R&D Agilent N67 Modular Power System Family: N678 Series Source/Measure Units Agilent N67 Modular Power System Family: Battery Charge/Discharge Module Agilent N67 Modular Power System Family: Mobile Communications DC Power Module Description The Agilent N67 Low-Profile Modular Power System (MPS) is a 1U (rack unit) high, multiple-output programmable DC power supply system that enables test system integrators to optimize performance, power and price to match test needs. Go to: http://cp.literature.agilent.com/litweb/pdf/5989-1411en.pdf The Agilent N675 DC Power Analyzer represents an entirely new instrument category for R&D engineers. It provides unrivaled productivity gains when sourcing and measuring DC voltage and current into a DUT. Using the Agilent N675 DC Power Analyzer, R&D engineers can gain insights into the DUT s power consumption in minutes, with all sourcing and measuring functions available from the front panel. Go to: http://cp.literature.agilent.com/litweb/pdf/5989-6319en.pdf The Agilent N6781A and N6782A 2-quadrant SMUs offer advanced sourcing and measurement capabilities required to overcome test challenges associated with optimizing power consumption and maximizing battery life of battery-powered devices and their components. The Agilent N6784A 4-quadrant SMU offers advanced sourcing and measurement capabilities in four quadrants for general purpose applications. Go to: http://cp.literature.agilent.com/litweb/pdf/599-5829en.pdf The Agilent N6783A-BAT battery charge/discharge module is a basic, 2-quadrant DC power module designed to be used by mobile device designers. Its 2-quadrant operation allows it to act as a programmable power supply to charge the battery or as a programmable electronic load to discharge the battery, all in one instrument. Go to: http://cp.literature.agilent.com/litweb/pdf/599-8662en.pdf The Agilent N6783A-MFG mobile communications DC power module offers advanced features specifically for testing battery-powered (mobile) devices in manufacturing or automated test environments. Go to: http://cp.literature.agilent.com/litweb/pdf/599-8643en.pdf NOTE You can contact Agilent Technologies at one of the following telephone numbers for warranty, service, or technical support information. In the United States: (8) 829-4444 In Europe: 31 2 547 2111 In Japan: 12-421-345 Or use our Web link for information on contacting Agilent in your country or specific location: www.agilent.com/find/assist Or contact your Agilent Technologies Representative. The web contains the most up to date version of this manual. Go to http://cp.literature.agilent.com/litweb/pdf/n67-91.pdf. N6731B-N6784A DC Power Modules Specifications Guide 3

Contents 1 - Power Module Differences... 5 Power Module Differences for Agilent N67 Modular Power Systems. 6 Power Module Differences for Agilent N675 DC Power Analyzers... 8 Power Module Option Characteristics... 1 2 - Agilent N673xB, N674xB, N677xA DC Power Modules... 11 Performance Specifications... 12 Supplemental Characteristics... 14 Output Quadrant Characteristic... 16 Arbitrary Waveform Generator Maximum Bandwidth... 16 3 - Agilent N675xA High Performance Power Modules... 19 Performance Specifications... 2 Supplemental Characteristics... 21 Autoranging Characteristic... 23 Output Impedance Graphs... 23 Arbitrary Waveform Generator Maximum Bandwidth... 26 4 - Agilent N676xA Precision Power Modules... 27 Performance Specifications... 28 Supplemental Characteristics... 29 Autoranging Characteristic... 31 Output Impedance Graphs... 31 Arbitrary Waveform Generator Maximum Bandwidth... 34 5 - Agilent N6781A, N6782A, N6784A Source/Measure Units... 35 Performance Specifications... 36 Supplemental Characteristics... 37 Output Quadrant Characteristic... 42 Output Impedance Graphs... 42 6 - Agilent N6783A-BAT, N6783A-MFG Application-Specific Power Modules... 43 Performance Specifications... 44 Supplemental Characteristics... 45 Output Quadrant Characteristic... 46 7 - Agilent N67 Modular Power System Mainframes... 47 Supplemental Characteristics... 48 Outline Diagrams... 5 4 N6731B-N6784A DC Power Modules Specifications Guide

Chapter 1 Power Module Differences Power Module Differences for Agilent N67 Modular Power Systems. 6 Power Module Differences for Agilent N675 DC Power Analyzers... 8 Power Module Option Characteristics... 1 This chapter provides a brief overview of the basic differences between the Agilent N67 series DC Power Modules. Note that the basic capabilities of a power module depend not only on its hardware capabilities, but also the on the hardware and firmware capabilities of the mainframe in which it is installed. In addition to their primary output and measurement capabilities, power modules installed in an Agilent N675 DC Power Analyzer have expanded capabilities such as front panel scope view, arbitrary waveform generation, and internal and external data logging. Refer to the Agilent N67 or N675 User s Guide for more information about the power module capabilities. N6731B-N6784A DC Power Modules Specifications Guide 5

Power Module Differences for Agilent N67 Modular Power Systems Agilent N6731B N6777A Differences Feature DC Power High-Performance Precision ( = available) N673xB, N674xB, N677xA N675xA N676xA 5 W output rating N6731B N6736B N6751A N6761A 1 W output rating N6741B N6746B N6752A N6762A 3 W output rating N6773A N6777A N6753A, N6754A N6763A, N6764A 5 W output rating N6755A, N6756A N6765A, N6766A Output disconnect relays Option 761 Option 761 Option 761 Output disconnect/polarity reversal relays NOTE 1 Option 76 Option 76 Option 76 Autoranging output capability Voltage or current turn-on priority Precision voltage and current measurements Low voltage and current output ranges Low voltage and current measurement ranges N6761A, N6762A N6761A, N6762A 2 microampere measurement range NOTE 2 Option 2UA Simultaneous voltage and current measurements SCPI command output list capability NOTE 3 Option 54 Option 54 SCPI command array readback NOTE 3 Option 54 Option 54 SCPI command programmable sample rate NOTE 3 Option 54 Option 54 SCPI command external data logging NOTE 3 Option 54 Option 54 Double-wide (occupies 2 channel locations) N6753A N6756A N6763A N6766A 1 Option 76 limits the output current to 1A maximum on Models N6742B and N6773A. Option 76 is not available on Models N6741B, N6751A, N6752A, N6761A, and N6762A. 2 Option 2UA.is only available on Models N6761A and N6762A. It includes Option 761. 3 Only available when using the remote interfaces; not from the front panel. 6 N6731B-N6784A DC Power Modules Specifications Guide

Agilent N6781A N6784A Differences Feature Source/Measure Units (SMU) Application-Specific ( = available) N6781A N6782A N6784A N6783A-BAT N6783A-MFG Output rating 2 W 2 W 2 W 24 W 18 W 2-quadrant operation 4-quadrant operation Auxiliary voltage measurement input Output disconnect relays Option 761 Option 761 Negative voltage protection Voltage or current priority mode Programmable output resistance 6 mv output range 3 ma output range 1 ma, 1 ma output ranges 1 V, 1 mv measurement ranges 1 ma, 1 ma, 1 μa measurement ranges 15 ma measurement range Simultaneous voltage and current measurements Seamless measurement autoranging SCPI command output list capability NOTE 1, 2 SCPI command array readback NOTE 2 SCPI command programmable sample rate NOTE 2 SCPI command external data logging NOTE 2 1 List capability is not available on the negative current output on Model N6783A. 2 Only available when using the remote interfaces; not the front panel. N6731B-N6784A DC Power Modules Specifications Guide 7

Power Module Differences for Agilent N675 DC Power Analyzers Agilent N6731B N6777A Differences Feature DC Power High-Performance Precision ( = available) N673xB, N674xB, N677xA N675xA N676xA 5 W output rating N6731B N6736B N6751A N6761A 1 W output rating N6741B N6746B N6752A N6762A 3 W output rating N6773A N6777A N6753A, N6754A N6763A, N6764A 5 W output rating N6755A, N6756A N6765A, N6766A Output disconnect relays Option 761 Option 761 Option 761 Output disconnect/polarity reversal relays NOTE 1 Option 76 Option 76 Option 76 Arbitrary waveform generation Autoranging output capability Voltage or current turn-on priority Precision voltage and current measurements Low voltage and current output ranges Low voltage and current measurement ranges N6761A, N6762A N6761A, N6762A 2 microampere measurement range NOTE 2 Option 2UA Voltage or current scope traces Simultaneous voltage and current scope traces Simultaneous voltage and current data logging NOTE 3 Interleaved voltage and current data logging NOTE 3 Dynamic current correction N6751A, N6752A N6761A, N6762A SCPI command output list capability NOTE 4 SCPI command array readback NOTE 4 SCPI command programmable sample rate NOTE 4 SCPI command external data logging NOTE 4 Double-wide (occupies 2 channel locations) N6753A N6756A N6763A N6766A 1 Option 76 limits the output current to 1A maximum on Models N6742B and N6773A. Option 76 is not available on Models N6741B, N6751A, N6752A, N6761A, and N6762A. 2 Option 2UA is only available on Models N6761A and N6762A. It includes Option 761. 3 Option 55 deletes the Data Logger function on Model N675. 4 Only available when using the remote interfaces; not from the front panel. 8 N6731B-N6784A DC Power Modules Specifications Guide

Agilent N6781A N6784A Differences Feature Source/Measure Units (SMU) Application-Specific ( = available) N6781A N6782A N6784A N6783A-BAT N6783A-MFG Output rating 2 W 2 W 2 W 24 W 18 W 2-quadrant operation 4-quadrant operation Auxiliary voltage measurement input Output disconnect relays Option 761 Option 761 Arbitrary waveform generation NOTE 1 Negative voltage protection Voltage or current priority mode CC load/cv load Voltage/current measurement only Battery emulator/charger Programmable output resistance 6 mv output range 3 ma output range 1 ma, 1 ma output ranges 1 V, 1 mv measurement ranges 1 ma, 1 ma, 1 μa measurement ranges 15 ma measurement range Voltage or current scope traces Simultaneous voltage and current scope traces Simultaneous voltage and current data logging NOTE 2 Interleaved voltage and current data logging NOTE 2 Seamless measurement autoranging SCPI command output list capability NOTE 1, 3 SCPI command array readback NOTE 3 SCPI command programmable sample rate NOTE 3 SCPI command external data logging NOTE 3 SCPI command histogram measurements NOTE 3 1 Arbitrary waveform generation and list capability are not available on the negative current output on Model N6783A. 2 Option 55 deletes the Data Logger function on Model N675. 3 Only available when using the remote interfaces; not the front panel. N6731B-N6784A DC Power Modules Specifications Guide 9

Power Module Option Characteristics Option 76 & 761 + sense + rail Option 761 - rail - sense +S + -S Option 761 provides output and sense disconnect relays. Option 76 provides polarity reversal in addition to output and sense disconnect. Note that models N678xA SMU have output and sense disconnect relays built in. Option 76 limits the output current to 1 A on Models N6742B and N6773A. Option 76 is not available on Models N6741B, N6751A, N6752A, N6761A, N6762A, and N6781A N6784A Although the plus and minus rail of the output power mesh are physically disconnected from the output terminals with options 76 and 761, a small AC network is still connected across the plus and minus output terminals (see figure). Option 54 Option 2UA Option 54 (High-speed Test Extensions) include output list and digitized measurement capability. This option is separately orderable for Models N673xB, N674xB, N677xA, and N675xA when installed in an N67 MPS mainframes. All other power modules as well as the N675 DC Power Analyzer mainframes have output list and digitized measurement capability built in. Output list: Maximum number of steps = 512 Maximum dwell time in seconds = 262 Maximum list repetitions = 256 or infinite Digitized measurement: Maximum measurement points = 524,288 Maximum sample rate = 97.656 khz Option 2UA is a 2 microampere measurement range available on Models N6761A and N6762A only. It includes Option 761 relay capability. 1 N6731B-N6784A DC Power Modules Specifications Guide

Chapter 2 Agilent N673xB, N674xB, N677xA DC Power Modules Performance Specifications... 12 Supplemental Characteristics... 14 Output Quadrant Characteristic... 16 Arbitrary Waveform Generator Maximum Bandwidth... 16 Unless otherwise noted, specifications are warranted over the ambient temperature range of to 4 C after a 3-minute warm-up period. Specifications apply at the output terminals, with each module's sense terminals internally connected to its output terminals (local sensing). Refer to the Agilent N67 or N675 Service Guide for the setup conditions for all performance specifications. Supplemental characteristics are not warranted but are descriptions of performance determined either by design or by type testing. All supplemental characteristics are typical unless otherwise noted. N6731B-N6784A DC Power Modules Specifications Guide 11

Performance Specifications DC Output Ratings: N6731B/ N6741B N6732B/ N6742B N6733B/ N6743B N6734B/ N6744B N6735B/ N6745B N6736B/ N6746B Voltage - 5 V - 8 V - 2 V - 35 V - 6 V - 1 V NOTE 2 Current NOTE 1-1 A/ -2 A -6.25 A/-12.5 A -2.5 A / -5 A -1.5 A / -3 A -.8 A / -1.6 A -.5 A / -1 A Power 5 W / 1 W 5 W / 1 W 5 W / 1 W 52.5W / 15W 5 W / 1 W 5 W / 1 W Output Ripple and Noise (PARD): (from 2 Hz 2 MHz) CV peak-to- peak 1 mv / 2 mv 12 mv 14 mv 15 mv 25 mv 3 mv CV rms 2 mv 2 mv 3 mv 5 mv 9 mv 18 mv Load Effect (Regulation): (Applies for any output load change, with a maximum load-lead drop of 1V/lead. The load lead drop reduces the maximum available voltage at the load.) Voltage 5 mv 6 mv 9 mv 11 mv 13 mv / 16 mv 2 mv / 3 mv Current 2 ma 2 ma 2 ma 2 ma 2 ma 2 ma Source Effect (Regulation): Voltage 1 mv 2 mv 2 mv 4 mv 6 mv 1 mv Current 1 ma 1 ma 1 ma 1 ma 1 ma 1 ma Programming Accuracy: (@ 23 C ±5 C after a 3 minute warm-up. Applies from minimum to maximum programming range at any load.) Voltage.1% + 19 mv.1% + 19 mv.1% + 2 mv.1% + 35 mv.1% + 6 mv.1% +1 mv Current.15% + 2 ma.15% + 2 ma.15% + 2 ma.15% + 2 ma.15% + 2 ma.15% + 1mA Voltmeter/Ammeter Measurement Accuracy: (@ 23 C ±5 C. Applies when measuring the default value of 124 data points with a 2.48 μs time interval.) Voltage.1% + 2 mv.1% + 2 mv.1% + 2 mv.1% + 35 mv.1% + 6 mv.1% +1 mv Current.15% + 2 ma.15% + 1 ma.15% + 5 ma.15% + 4 ma.15% + 4 ma.15% + 2 ma Load Transient Recovery Time: (Time to recover to within the settling band following a load change from 5% to 1% and from 1% to 5% of full load.) NOTE 3 NOTE 3 Voltage settling band ±.8 V /.1 V ±.8 V /.1 V ±.2 V /.3 V ±.2 V /.3 V ±.4 V /.5 V ±.5 V / 1. V Time < 2 µs < 2 µs < 2 µs < 2 µs < 2 µs < 2 µs 12 N6731B-N6784A DC Power Modules Specifications Guide

DC Output Ratings: Performance Specifications (continued) N6773A N6774A N6775A N6776A N6777A Voltage - 2 V - 35 V - 6 V - 1 V - 15 V Current NOTE 1-15 A NOTE 2-8.5 A - 5 A - 3 A - 2 A Power 3 W 3 W 3 W 3 W 3 W Output Ripple and Noise (PARD): (from 2 Hz 2 MHz) CV peak-to- peak 2 mv 22 mv 35 mv 45 mv 68 mv CV rms 3 mv 5 mv 9 mv 18 mv 27 mv Load Effect (Regulation): (Applies for any output load change, with a maximum load-lead drop of 1V/lead. The load lead drop reduces the maximum available voltage at the load.) Voltage 13 mv 16 mv 24 mv 45 mv 68 mv Current 6 ma 6 ma 6 ma 6 ma 6 ma Source Effect (Regulation): Voltage 2 mv 4 mv 6 mv 1 mv 15 mv Current 1 ma 1 ma 1 ma 1 ma 1 ma Programming Accuracy: (@ 23 C ±5 C after 3 minute warm-up. Applies from minimum to maximum programming range at any load.) Voltage.1% + 2 mv.1% + 35 mv.1% + 6 mv.1% +1 mv.1% +15 mv Current.15% + 6 ma.15% + 6 ma.15% + 6 ma.15% + 3 ma.15% + 3 ma Voltmeter/Ammeter Measurement Accuracy: (@ 23 C ±5 C. Applies when measuring the default value of 124 data points with a 2.48 μs time interval.) Voltage.1% + 2 mv.1% + 35 mv.1% + 6 mv.1% +1 mv.1% +15 mv Current.15% + 15 ma.15% + 12 ma.15% + 12 ma.15% + 6 ma.15% + 6 ma Load Transient Recovery Time: (Time to recover to within the settling band following a load change from 5% to 1% and from 1% to 5% of full load.) Voltage settling band ±.3 V NOTE 4 ±.3 V NOTE 4 ±.5 V ± 1. V ± 2. V Time < 25 µs < 25 µs < 25 µs < 25 µs < 25 µs 1 Output current is derated 1% per C above 4 C. 2 When relay option 76 is installed on Models N6742B and N6773A, the output current is limited to 1 A. 3 When relay option 76 or 761 is installed, the settling band is ±.1V/.125 V. Option 76 is not available on Model N6741B. 4 When relay option 76 or 761 is installed, the settling band is ±.35 V. N6731B-N6784A DC Power Modules Specifications Guide 13

Supplemental Characteristics Programming Ranges: N6731B/ N6741B N6732B/ N6742B N6733B/ N6743B N6734B/ N6744B N6735B/ N6745B N6736B/ N6746B Voltage 15 mv 5.1 V 15 mv 8.16 V 3 mv 2.4 V 4 mv 35.7 V 7 mv 61.2 V 1 mv 12 V Current 6 ma 1.2 A/ 6 ma 2.4 A Programming Resolution: 4 ma 6.375 A/ 4 ma 12.75 A 1 ma 2.55 A/ 1 ma 5.1 A 5 ma 1.53 A/ 5 ma 3.6 A 2.5 ma.85 A/ 2.5 m A 1.7 A 1.5 ma.51a/ 1.5 ma 1.2 A Voltage 3.5 mv 4 mv 7 mv 1 mv 18 mv 28 mv Current 7 ma 4 ma 3 ma 2 ma 1 ma.5 ma Measurement Resolution: Voltage 3 mv 4 mv 1 mv 18 mv 3 mv 5 mv Current 1 ma 7 ma 3 ma 2 ma 1 ma.5 ma Programming Temperature Coefficient per C: Voltage.5% +.1mV.5% +.1 mv.5% +.2 mv.5% +.5 mv.5% +.5 mv.5% + 1 mv Current.5% + 1 ma.5% +.5 ma.5% +.1 ma.5% +.5 ma.5% +.2 ma.5% +.2 ma Measurement Temperature Coefficient per C: Voltage.1% +.1mV.1% +.1 mv.1% +.2 mv.1% +.2 mv.1% +.5 mv.1% +.5 mv Current.1% + 1 ma.1% +.5 ma.1% +.1 ma.1% +.5 ma.1% +.2 ma.1% +.2 ma N675 Mainframe Oscilloscope Measurement Accuracy: (@t 23 C ±5 C; accuracy of any individual point in the trace) Voltage.1% + 25 mv.1% + 3 mv.1% + 45 mv.1% + 75 mv.1% + 13 mv.1% + 19 mv Current Correction On NOTE 1.15% + 5 ma.15% + 3 ma.15% + 15 ma.15% + 1 ma.15% + 9 ma.15% + 5 ma Current.15% + 7 ma.15% + 4 ma.15% + 2 ma.15% + 14 ma.15% + 12 ma.15% + 7 ma Up-programming and Down-programming Time with full resistive load: (Time from 1% to 9% of total voltage excursion; for voltage setting from V to full scale and full scale to V) 2 ms 2 ms 2 ms 2 ms 2 ms 2 ms Up-programming and Down-programming Settling Time with full resistive load: (Time from start of voltage change to.1% of full-scale value; for voltage setting from V to full scale and full scale to V) 1 ms 1 ms 1 ms 1 ms 1 ms 1 ms Over-voltage Protection: Accuracy.25% + 5mV.25% + 5 mv.25% + 75 mv.25% + 1 mv.25% + 2 mv.25% + 25 mv Accuracy with Opt. 76.25%+6mV.25% + 6 mv.25% + 35 mv.25% + 25 mv.25% + 3 mv.25% + 3 mv Accuracy with Opt. 761.25%+6mV.25% + 6 mv.25% + 35 mv.25% + 25 mv.25% + 3 mv.25% + 3 mv Maximum setting 7.5 V 1 V 22 V 38.5 V 66 V 11 V Response time 5 µs from occurrence of over-voltage condition to start of output shutdown Output Ripple and Noise (PARD): CC rms 8 ma 4 ma 2 ma 2 ma 2 ma 2 ma Common Mode Noise: (from 2 Hz 2 MHz; from either output to chassis) Rms 1 ma 1 ma 1 ma 1 ma 1 ma 1 ma Peak-to- peak < 15 ma < 1 ma < 1 ma < 1 ma < 1 ma < 1 ma Remote Sense Capability: Outputs can maintain specifications with up to a 1-volt drop per load lead. The load lead drop reduces the maximum available voltage at the load. Series and Parallel Operation: Identically rated outputs can be operated directly in parallel or can be connected for straight series operation. Auto-series and auto-parallel operation is not available. Minimum Output Turn-On Delay: (Time from when any Output On command is received until the output starts turning on) Without relay option 32 ms 32 ms 32 ms 32 ms 32 ms 32 ms With relay Option 76 58 ms 58 ms 58 ms 58 ms 58 ms 58 ms 14 N6731B-N6784A DC Power Modules Specifications Guide

Programming Ranges: Supplemental Characteristics (continued) N6773A N6774A N6775A N6776A N6777A Voltage 3 mv 2.4 V 4 mv 35.7 V 7 mv 61.2 V 1 mv 12 V 145 mv 153 V Current 3 ma 15.3 A 15 ma 8.67 A 7.5 ma 5.1 A 4.5 ma 3.6 A 2.75 ma 2.4 A Programming Resolution: Voltage 7 mv 1 mv 18 mv 28 mv 43 mv Current 9 ma 6 ma 3 ma 1.5 ma 1 ma Measurement Resolution: Voltage 1 mv 18 mv 3 mv 5 mv 77 mv Current 9 ma 6 ma 3 ma 1.5 ma 1 ma Programming Temperature Coefficient per C: Voltage.1% +.2 mv.1% +.5 mv.1% +.5 mv.1% + 1 mv.1% + 1 mv Current.1% +.5 ma.1% +.5 ma.1% +.1 ma.1% +.1 ma.1% +.1 ma Measurement Temperature Coefficient per C: Voltage.1% +.2 mv.1% +.2 mv.1% +.5 mv.1% +.5 mv.1% +.5 mv Current.1% +.5 ma.1% +.5 ma.1% +.5 ma.1% +.5 ma.1% +.5 ma N675 Mainframe Oscilloscope Measurement Accuracy: (@ 23 C ±5 C; accuracy of any individual point in the trace) Voltage.1% + 45 mv.1% + 75 mv.1% + 12 mv.1% + 16 mv.1% + 175 mv Current Correction On NOTE 1.15% + 35 ma.15% + 22 ma.15% + 19 ma.15% + 9 ma.15% + 9 ma Current.15% + 45 ma.15% + 27 ma.15% + 22 ma.15% + 12 ma.15% + 12 ma Up-programming and Down-programming Time with full resistive load: (Time from 1% to 9% of total voltage excursion; for voltage setting from V to full scale and full scale to V) 2 ms 2 ms 2 ms 2 ms 2 ms Maximum Up-programming and Down-programming Settling Time with full resistive load: (Time from start of voltage change to.1% of full-scale value; for voltage setting from V to full scale and full scale to V) Over-voltage Protection: 1 ms 1 ms 1 ms 1 ms 1 ms Accuracy.25% +1 mv.25% + 13 mv.25% + 26 mv.25% + 65 mv.25% + 65 mv Accuracy with Opt. 761.25% + 5 mv.25% + 35 mv.25% + 35 mv.25% + 65 mv.25% + 65 mv Accuracy with Opt. 76.25% + 7 mv.25% + 7 mv.25% + 4 mv.25% + 65 mv.25% + 65 mv Maximum setting 22 V 38.5 V 66 V 11 V 165 V Response time Output Ripple and Noise (PARD): 5 µs from occurrence of over-voltage condition to start of output shutdown CC rms 6 ma 6 ma 6 ma 6 ma 6 ma Common Mode Noise: (from 2 Hz 2 MHz; from either output to chassis) Rms 2 ma 2 ma 2 ma 2 ma 2 ma Peak-to- peak < 2 ma < 2 ma < 2 ma < 2 ma < 2 ma Remote Sense Outputs can maintain specifications with up to a 1-volt drop per load lead. Capability: The load lead drop reduces the maximum available voltage at the load. Series and Identically rated outputs can be operated directly in parallel or can be connected for straight series operation. Parallel Operation: Auto-series and auto-parallel operation is not available. Minimum Output Turn-On Delay: (Time from when any Output On command is received until the output starts turning on) Without relay option 32 ms 32 ms 32 ms 32 ms 32 ms With relay Option 76 58 ms 58 ms 58 ms 58 ms 58 ms 1 Correction On compensates for current flowing into the output capacitor during voltage transients. N6731B-N6784A DC Power Modules Specifications Guide 15

Output Quadrant Characteristic + rated voltage Voltage maximum power + rated current Current Arbitrary Waveform Generator Maximum Bandwidth NOTE The information in this section only applies when the power modules are installed in an Agilent N675 DC Power Analyzer. The following tables characterize the maximum bandwidth of the arbitrary waveform generator. The maximum bandwidth is based on a sine wave into a resistive load and apples to any output current. The following definitions apply in the frequency tables: V p-p = Voltage peak-to-peak 3 db max. = Max. frequency where the voltage drops to 3 db below its setting 6 db max. = Max. frequency where the voltage drops to 6 db below its setting THD 3 db = The total harmonic distortion at 3 db max. frequency THD 6 db = The total harmonic distortion at 6 db max. frequency Voltage 3 db max THD 3 db 6 db max THD 6 db N6731B & N6741B.1 Vp-p 175 Hz 1.% 26 Hz 3.%.1 Vp-p 125 Hz 1.% 175 Hz 3.%.3 Vp-p 75 Hz 6.% 1 Hz 6.%.5 Vp-p 4 Hz 9.% 55 Hz 9.% 5. Vp-p 2 Hz 1% 37 Hz 1% N6732B & N6742B.1 Vp-p 125 Hz 1.% 2 Hz 3.%.2 Vp-p 125 Hz 1.% 18 Hz 3.%.4 Vp-p 75 Hz 6.% 1 Hz 6.%.8 Vp-p 4 Hz 8.5% 6 Hz 8.5% 8. Vp-p 2 Hz 1% 37 Hz 1% 16 N6731B-N6784A DC Power Modules Specifications Guide

Arbitrary Waveform Generator Maximum Bandwidth (continued) Voltage 3 db max THD 3 db 6 db max THD 6 db 3 db max THD 3 db 6 db max THD 6 db N6733B & N6743B N6773A.2 Vp-p 11 Hz 1.% 19 Hz 3.% 125 Hz 1.5% 21 Hz 4.%.4 Vp-p 11 Hz 1.% 16 Hz 3.% 125 Hz 1.5% 18 Hz 4.% 1. Vp-p 72 Hz 6.% 95 Hz 6.% 75 Hz 6.% 95 Hz 6.% 2. Vp-p 4 Hz 8.% 55 Hz 8.5% 42 Hz 9.% 6 Hz 9.% 2 Vp-p 2 Hz 1% 37 Hz 1% 2 Hz 1% 37 Hz 1% N6734B & N6744B N6774A.4 Vp-p 125 Hz 1.% 2 Hz 1.% 125 Hz 1.% 2 Hz 1.%.7 Vp-p 125 Hz 1.% 175 Hz 3.5% 125 Hz 1.% 16 Hz 3.% 1.8 Vp-p 72 Hz 6.% 1 Hz 6.% 75 Hz 6.% 95 Hz 6.% 3.5 Vp-p 4 Hz 8.% 55 Hz 8.5% 4 Hz 8.5% 55 Hz 8.5% 35 Vp-p 2 Hz 8.% 37 Hz 8.5% 2 Hz 1% 37 Hz 1% N6735B & N6745B N6775A.6 Vp-p 1 Hz 1.% 18 Hz 1.% 12 Hz 1.% 2 Hz 1.% 1.2 Vp-p 1 Hz 1.% 16 Hz 3.% 12 Hz 1.% 16 Hz 3.% 3. Vp-p 7 Hz 5.5% 92 Hz 5.5% 7 Hz 5.% 95 Hz 6.% 6. Vp-p 4 Hz 8.% 55 Hz 8.% 4 Hz 8.5% 55 Hz 8.5% 6 Vp-p 2 Hz 8.% 37 Hz 8.% 2 Hz 1% 35 Hz 1% N6736B & N6746B N6776A 1. Vp-p 9 Hz 1.% 16 Hz 1.5% 75 Hz 1.% 16 Hz 1.% 2. Vp-p 9 Hz 1.% 15 Hz 3.% 75 Hz 1.% 15 Hz 3.% 5. Vp-p 62 Hz 4.5% 85 Hz 6.% 55 Hz 4.% 75 Hz 6.% 1 Vp-p 37 Hz 8.% 5 Hz 8.% 35 Hz 8.% 45 Hz 8.% 1 Vp-p 2 Hz 8.% 35 Hz 8.% 35 Hz 8.% N6777A 1.5 Vp-p 7 Hz 1.% 15 Hz 1.% 3. Vp-p 55 Hz 5.% 12 Hz 2.% 7.5 Vp-p 55 Hz 5.% 7 Hz 6.% 15 Vp-p 35 Hz 7.% 55 Hz 7.% 15 Vp-p 3 Hz 1.% N6731B-N6784A DC Power Modules Specifications Guide 17

Chapter 3 Agilent N675xA High Performance Power Modules Performance Specifications... 2 Supplemental Characteristics... 21 Autoranging Characteristic... 23 Output Impedance Graphs... 23 Arbitrary Waveform Generator Maximum Bandwidth... 26 Unless otherwise noted, specifications are warranted over the ambient temperature range of to 4 C after a 3-minute warm-up period. Specifications apply at the output terminals, with each module's sense terminals internally connected to its output terminals (local sensing). Refer to the Agilent N67 or N675 Service Guide for the setup conditions for all performance specifications. Supplemental characteristics are not warranted but are descriptions of performance determined either by design or by type testing. All supplemental characteristics are typical unless otherwise noted. N6731B-N6784A DC Power Modules Specifications Guide 19

Performance Specifications DC Output Ratings: N6751A/N6752A N6753A/N6755A N6754A/N6756A Voltage - 5 V - 2 V - 6 V Current NOTE 1-5 A / - 1 A - 5 A - 2 A / - 17A Power 5 W / 1 W 3 W / 5 W 3 W / 5 W Output Ripple and Noise (PARD): (from 2 Hz 2 MHz) CV peak-to-peak 4.5 mv 5 mv 6 mv CV rms.35 mv 1 mv 1 mv Load Effect (Regulation): (Applies for any output load change, with a maximum load-lead drop of 1V/lead. The load lead drop reduces the maximum available voltage at the load.) Voltage 2 mv 2 mv 2 mv Current 2 ma 12 ma 5 ma Source Effect (Regulation): Voltage 1 mv.5 mv 1.2 mv Current 1 ma 5 ma 2 ma Programming Accuracy: (@ 23 C ±5 C after 3 minute warm-up. Applies from minimum to maximum programming range at any load.) Voltage.6% + 19 mv.6% + 1 mv.6% + 25 mv Current.1% + 2 ma.1% + 3 ma.1% + 12 ma Voltmeter/Ammeter Measurement Accuracy: (@ 23 C ±5 C. Applies when measuring the default value of 124 data points with a 2.48 μs time interval.) Voltage.5% + 2 mv.5% + 1 mv.5% + 25 mv Current.1% + 4 ma.1% + 3 ma.1% + 8 ma Load Transient Recovery Time: (Time to recover to within the settling band following a load change - from 6% to 1% and from 1% to 6% of full load for model N6751A - from 5% to 1% and from 1% to 5% of full load for models N6752A through N6756A.) Voltage settling band ± 75 mv NOTE 2 ± 3 mv NOTE 3 ± 9 mv NOTE 4 Time < 1 µs < 1 µs < 1 µs 1 Output current is derated 1% per C above 4 C. 2 When relay option 761 is installed on Model N6752A, the settling band is ±125 mv. 3 When relay option 76 or 761 is installed on Model N6753A and N6755A, the settling band is ±2 mv. 4 When relay option 76 or 761 is installed on Model N6754A and N6756A, the settling band is ±35 mv. 2 N6731B-N6784A DC Power Modules Specifications Guide

Supplemental Characteristics N6751A / N6752A N6753A / N6755A N6754A / N6756A Programming Ranges: Voltage 2 mv 51 V 1 mv 2.4 V 25 mv- 61.2 V Current 1 ma 5.1A/1 ma 1.2A 5 ma 51 A 2 ma 2.4 A/2 ma 17.3A Programming Resolution: Voltage 3.5 mv 1.5 mv 4.2 mv Current 3.25 ma 16.3 ma 6.5 ma Measurement Resolution: Voltage 1.8 mv.8 mv 2.2 mv Current 41 µa 2.5 ma.82 ma Programming Temperature Coefficient per C: Voltage 18 ppm + 16 µv 35 ppm + 1 µv 35 ppm + 17 µv Current 1 ppm + 45 µa 6 ppm + 5 µa 6 ppm + 2 µa Measurement Temperature Coefficient per C: Voltage 25 ppm + 35 µv 5 ppm + 85 µv 5 ppm + 1 µv Current 6 ppm + 3 µa 6 ppm + 3 µa 6 ppm + 12 µa N675 Mainframe Oscilloscope Measurement Accuracy: (@ 23 C ±5 C, accuracy of any individual point in the trace) Voltage.5% + 32 mv.5% + 15 mv.5% + 37 mv Current with Correction On NOTE 1.1% + 14 ma Current.1% + 8 ma.1% + 52 ma.1% + 17 ma Up-programming Time with full resistive load: (Time from 1% to 9% of total voltage excursion) Small voltage step V to 1 V V to 6 V/ V to 1 V V to 15 V/ V to 29 V Time.2 ms.4 ms/.5 ms.35 ms/.7 ms Large voltage step V to 5 V V to 2 V V to 6 V Time 1.5 ms 1.5 ms 2 ms Up-programming Settling Time with full resistive load: (Time from start of voltage change to.1% of full scale value) Small voltage step V to 1 V V to 6 V/ V to 1 V V to 15 V/ V to 29 V Time.5 ms.8 ms/1. ms.8 ms/1.4 ms Large voltage step V to 5 V V to 2 V V to 6 V Time 4 ms 3 ms 4.2 ms Down-programming Time with no load: (Time from start of voltage change to output voltage <.5 V) Small voltage step 1 V to V 6 V to V/1 V to V 15 V to V/29 V to V Time.3 ms.55 ms/1. ms.6 ms/1.2 ms Large voltage step 5 V to V 2 V to V 6 V to V Time 1.3 ms 1.8 ms 2.2 ms Down-programming Settling Time with no load: (Time from start of voltage change to.1% of full scale value) Small voltage step 1 V to V 6 V to V/1 V to V 15 V to V/29 V to V Time.45 ms.8 ms/1.3 ms.8 ms/1.5 ms Large voltage step 5 V to V 2 V to V 6 V to V Time 1.4 ms 2 ms 2.3 ms N6731B-N6784A DC Power Modules Specifications Guide 21

Supplemental Characteristics (continued) N6751A / N6752A N6753A / N6755A N6754A / N6756A Down-programming Time with Capacitive load: (Time from start of voltage change to output voltage <.5 V) Small voltage step 1 V to V 6 V to V/1 V to V 15 V to V/29 V to V Time 2.1 ms 2.2 ms/4.5 ms 2.3 ms/5.5 ms Large voltage step 5 V to V 2 V to V 6 V to V Time 11 ms 8.5 ms 1 ms Capacitive load NOTE 2 1 µf 47 µf 68 µf Down-programming Capability: Continuous power 7 W 12.5 W 12.5 W Peak current 7 A 15 A 6 A Over-voltage Protection: Accuracy.25% +.25 V.25% +.15V.25% +.3V Accuracy with Option 761.25% +.25 V.25% +.45V.25% +.6V Accuracy with Option 76.25% +.45V.25% +.6V Maximum setting 55 V 22 V 66 V Response time Output Ripple and Noise: (PARD) 5 µs from occurrence of over-voltage condition to start of output shutdown CC rms: 2 ma 1 ma 4 ma Common Mode Noise: (from 2 Hz 2 MHz; from either output to chassis) rms 5 µa 5 µa 75 µa peak-to-peak < 2 ma < 2 ma < 3 ma Remote Sense Capability: Series and Parallel Operation: Outputs can maintain specifications with up to a 1-volt drop per load lead. The load lead drop reduces the maximum available voltage at the load. Identically rated outputs can be operated directly in parallel or be connected for straight series operation. Auto-series and auto-parallel operation is not available. Minimum Output Turn-On Delay: (Time from when any Output On command is received until the output starts turning on) Without relay option 25 ms 18 ms 18 ms With relay Option 76 51 ms 44 ms 44 ms 1 Correction On compensates for current flowing into the output capacitor during voltage transients. 2 Modules can discharge the specified capacitive load from full scale to V at a rate of 4 times/second. 22 N6731B-N6784A DC Power Modules Specifications Guide

Autoranging Characteristic Voltage 5 V 1 V 1 A N6751A 5 W Output 5 W curve Current 5 A Voltage 5 V 12 V 8.5 V Output Impedance Graphs 2 A N6752A 1 W Output 1 W curve Current 8.33 A 1 A Voltage 2 V 6 V 6 V 15 V 15 A 5 A N6753A / N6754A 3 W Output 3 W curve 5 A 2 A Current Voltage 2 V 6 V 1 V 29 V N6755A / N6756A 5 W Output 25 A 8.33 A 5 W curve 5 A 17 A Current 8 IMPEDANCE (ohms) 4 2 1.5.25 Magnitude Phase 9 45-45 -9 PHASE (degrees).125 1 1k 1k FREQUENCY (Hz) 1k Model N6752A, CC Mode, @5V, 2A N6731B-N6784A DC Power Modules Specifications Guide 23

IMPEDANCE (milliohms) 8 4 2 1 5 2.5 1.25 Magnitude Phase 9 45-45 -9 8 4 2 1 5 2.5 1.25 Magnitude Phase 135 9 45-45 PHASE (degrees).62.62 1 1k 1k 1k FREQUENCY (Hz) Model N6753A and N6755A, CV Mode, @2 V, 15A 1 1k 1k 1k FREQUENCY (Hz) Model N6753A and N6755A, Option 76, CV Mode, @2 V, 15A IMPEDANCE (ohms).8.4.2.1.5.25 Magnitude Phase 45-45 -9.8.4.2.1.5.25 Magnitude Phase 9 45-45 -9 PHASE (degrees).125-135.125.62.62 1 1k 1k 1k FREQUENCY (Hz) Model N6753A and N6755A, CC Mode, @2 V, 15A 1 1k 1k 1k FREQUENCY (Hz) Model N6753A and N6755A, Option 76, CC Mode, @2 V, 15A 24 N6731B-N6784A DC Power Modules Specifications Guide

.8.8 IMPEDANCE (ohms).4.2.1.5.25.125 Magnitude Phase 9 45-45 -9.4.2.1.5.25.125 Magnitude Phase 9 45-45 -9 PHASE (degrees).62.62 1 1k 1k 1k FREQUENCY (Hz) Model N6754A and N6756A, CV Mode, @6 V, 5A 1 1k 1k 1k FREQUENCY (Hz) Model N6754A and N6756A, Option 76, CV Mode, @6 V, 5A IMPEDANCE (ohms) 8 4 2 1.5.25.125 Magnitude Phase 45-45 -9-135 8 4 2 1.5.25.125 Magnitude Phase 45-45 -9-135 PHASE (degrees).62.62 1 1k 1k 1k FREQUENCY (Hz) Model N6754A and N6756A, CC Mode, @6 V, 5A 1 1k 1k 1k FREQUENCY (Hz) Model N6754A and N6756A, Option 76, CC Mode, @6 V, 5A N6731B-N6784A DC Power Modules Specifications Guide 25

Arbitrary Waveform Generator Maximum Bandwidth NOTE The information in this section only applies when the power modules are installed in an Agilent N675 DC Power Analyzer. The following tables characterize the maximum bandwidth of the arbitrary waveform generator. The maximum bandwidth is based on a sine wave into a resistive load and apples to any output current. The following definitions apply in the frequency tables: V p-p = Voltage peak-to-peak 3 db max. = Max. frequency where the voltage drops to 3 db below its setting THD 3 db = The total harmonic distortion at 3 db max. frequency THD < 1.5% = The frequency below which the THD is less than 1.5%. Voltage 3 db max THD 3 db THD < 1.5% N6751A & N6752A.5 Vp-p 4 Hz 12% 44 Hz 1. Vp-p 22 Hz 21% 44 Hz 2.5 Vp-p 9 Hz 25% 265 Hz 5. Vp-p 5 Hz 27% 16 Hz 5. Vp-p 34 Hz 22% 25 Hz N6753A & N6755A.2 Vp-p 23 Hz 1% 13 Hz.4 Vp-p 15 Hz 15% 8 Hz 1. Vp-p 98 Hz 19% 48 Hz 2. Vp-p 58 Hz 21% 3 Hz 2. Vp-p 4 Hz 12% 32 Hz N6754A & N6756A.6 Vp-p 28 Hz 8.% 16 Hz 1.2 Vp-p 14 Hz 15% 8 Hz 3. Vp-p 6 Hz 17% 3 Hz 6. Vp-p 4 Hz 2% 2 Hz 6. Vp-p 344 Hz 12% 3 Hz 26 N6731B-N6784A DC Power Modules Specifications Guide

Chapter 4 Agilent N676xA Precision Power Modules Performance Specifications... 28 Supplemental Characteristics... 29 Autoranging Characteristic... 31 Output Impedance Graphs... 31 Arbitrary Waveform Generator Maximum Bandwidth... 34 Unless otherwise noted, specifications are warranted over the ambient temperature range of to 4 C after a 3-minute warm-up period. Specifications apply at the output terminals, with each module's sense terminals internally connected to its output terminals (local sensing). Refer to the Agilent N67 or N675 Service Guide for the setup conditions for all performance specifications. Supplemental characteristics are not warranted but are descriptions of performance determined either by design or by type testing. All supplemental characteristics are typical unless otherwise noted. N6731B-N6784A DC Power Modules Specifications Guide 27

Performance Specifications N6761A/N6762A N6763A/N6765A N6764A/N6766A DC Ratings: Voltage - 5 V - 2 V - 6 V Current NOTE 1-1.5 A / - 3 A - 5 A - 2 A / - 17 A Power 5 W / 1 W 3 W / 5 W 3 W / 5 W Low programming ranges (V & I) 5.5 V; 1 ma Low measurement ranges (V & I) 5.5 V; 1 ma 2 V; 1.5 A 6 V;.5 A Output Ripple and Noise (PARD): (from 2 Hz 2 MHz) CV peak-to-peak 4.5 mv 5 mv 6 mv CV rms.35 mv 1 mv 1 mv Load Effect (Regulation): (Applies for any output load change, with a maximum load-lead drop of 1V/lead. The load lead drop reduces the maximum available voltage at the load.) Voltage.5 mv 2 mv 2 mv Current 3 µa (@ 7 V) 65 µa (@ 7 5V) 12 ma 5 ma Source Effect (Regulation): Voltage.5 mv.5 mv 1.2 mv Current 3 µa 5 ma 2 ma Programming Accuracy: (@ 23 C ±5 C after 3 minute warm-up. Applies from minimum to maximum programming range at any load.) Voltage, high range.16% + 6 mv.3% + 5 mv.3% + 12 mv Voltage, low range.16% + 1.5 mv Current, high range.4% + 2 µa.1% + 15 ma.75% + 4 ma Current, low range.4% + 3 µa (@ 7 V).4% + 55 µa (@ 7 5 V) Voltmeter/Ammeter Measurement Accuracy: (@ 23 C ±5 C. Applies when measuring 496 data points with a 2.48 μs time interval.) Voltage, high range.16% + 6 mv.3% + 1 mv.3% + 25 mv Voltage, low range.16% + 1.5 mv.3% + 1.5 mv.3% + 5 mv Current, high range.4% + 16 µa.1% + 1 ma.1% + 5 ma Current, low range.3% + 15 µa (@ 7 V).5% + 1.1 ma NOTE 2.5% +.75 ma NOTE 2.3% + 55 µa (@ 7 5 V) 2 µa current range (Option 2UA).5% + 1 na Load Transient Recovery Time: (time to recover to within the settling band following a load change - from 6% to 1% and from 1% to 6% of full load for model N6761A - from 5% to 1% and from 1% to 5% of full load for model N6762A through N6766A) Voltage settling band ± 75 mv ± 3 mv NOTE 3 ± 9 mv NOTE 4 Time < 1 µs < 1 µs < 1 µs 1 Output current is derated 1% per C above 4 C. 2 Applies when measuring currents that remain within the low range. Due to thermal settling, when transitioning from measuring full-rated output current (the worst case), to measuring the current within the low range, the low range accuracy specification is typically met within 5 seconds after the current has transitioned into the low range. Accuracies within this 5 second settling period are typically 2X the specified accuracy or better. 3 When relay option 76 or 761 is installed on Models N6763Aand N6765A, the settling band is ±2 mv. 4 When relay option 76 or 761 is installed on Models N6764Aand N6766A, the settling band is ±35 mv. 28 N6731B-N6784A DC Power Modules Specifications Guide

Supplemental Characteristics Programming Ranges: N6761A / N6762A N6763A / N6765A N6764A / N6766A Voltage, high range 15 mv 51 V 1 mv 2.4 V 25 mv- 61.2 V Voltage, low range 12 mv 5.5 V Current, high range 1 ma 1.53 A/1 ma 3.6 A 5 ma 51 A 2 ma 2.4A/2 ma 17.3A Current, low range.1 ma.1 A NOTE 1 Programming Resolution: Voltage, high range 88 µv 1.5 mv 4.2 mv Voltage, low range 9 µv Current, high range 6 µa 16.3 ma 6.5 ma Current, low range 2 µa Measurement Resolution: Voltage, high range 44 µv 25 µv 6 µv Voltage, low range 44 µv 25 µv 6 µv Current, high range 3 µa 5 µa 25 µa Current, low range 1 µa 2 µa 1 µa 2 µa current range (Option 2UA) 4 na Programming Temperature Coefficient per C: Voltage, high range 18 ppm + 14 µv 23 ppm + 95 µv 23 ppm + 218 µv Voltage, low range 4 ppm + 7 µv Current, high range 33 ppm + 1 µa 25ppm + 129 µa 25ppm + 52 µa Current, low range 6 ppm + 1.5 µa Measurement Temperature Coefficient per C: Voltage, high range 23 ppm + 4 µv 23 ppm + 53 µv 23 ppm + 73 µv Voltage, low range 3 ppm + 4 µv 25 ppm + 53 µv 25 ppm + 73 µv Current, high range 4 ppm +.3 µa 25 ppm + 21 µa 25 ppm + 7 µa Current, low range 5 ppm +.3 µa 27 ppm + 21 µa 27 ppm + 7 µa Current, 2 µa range (Option 2UA) 1 ppm + 3 na/ C N675 Mainframe Oscilloscope Measurement Accuracy: (@ 23 C ±5 C, accuracy of any individual point in the trace) Voltage.16% + 16 mv.3% + 13 mv.3% + 32 mv Current, high range with Correction On NOTE 2.4% + 1 ma Current, high range.4% + 1 ma.1% + 16 ma.1% + 8.4 ma Current, low range.3% +.175 ma.5% + 6.6 ma.5% + 2.6 ma Up-programming Time with full resistive load: (Time from 1% to 9% of total voltage excursion) Small voltage step V to 1 V V to 6 V/ V to 1 V V to 15 V/ V to 29 V Time.6 ms.4 ms/.5 ms.35 ms/.7 ms Large voltage step V to 5 V V to 2 V V to 6 V Time 2.2 ms 1.5 ms 2 ms Up-programming Settling Time with full resistive load: (Time from start of voltage change to.1% of full scale value) Small voltage step V to 1 V V to 6 V/ V to 1 V V to 15 V/ V to 29 V Time.9 ms.8 ms/1. ms.8 ms/1.4 ms Large voltage step V to 5 V V to 2 V V to 6 V Time 4 ms 3 ms 4.2 ms N6731B-N6784A DC Power Modules Specifications Guide 29

Supplemental Characteristics (continued) N6761A / N6762A N6763A / N6765A N6764A / N6766A Down-programming Time with no load: (time from start of voltage change to output voltage <.5 V) Small voltage step 1 V to V 6 V to V/1 V to V 15 V to V/29 V to V Time.3 ms.55 ms/1. ms.6 ms/1.2 ms Large voltage step 5 V to V 2 V to V 6 V to V Time 1.3 ms 1.8 ms 2.2 ms Down-programming Settling Time with no load: (time from start of voltage change to.1% of full scale value) Small voltage step 1 V to V 6 V to V/1 V to V 15 V to V/29 V to V Time.45 ms.8 ms/1.3 ms.8 ms/1.5 ms Large voltage step 5 V to V 2 V to V 6 V to V Time 1.4 ms 2 ms 2.3 ms Down-programming Time with Capacitive load: (time from start of voltage change to output voltage <.5 V) Small voltage step 1 V to V 6 V to V/1 V to V 15 V to V/29 V to V Time 4.5 ms 2.2 ms/4.5 ms 2.3 ms/5.5 ms Large voltage step 5 V to V 2 V to V 6 V to V Time 23 ms 8.5 ms 1 ms Capacitive load NOTE 3 1 µf 47 µf 68 µf Down-programming Capability: Continuous power 7 W 12.5 W 12.5 W Peak current 3.8 A 15 A 6 A Over-voltage Protection: Accuracy.25% +.25 V.25% +.15 V.25% +.3 V Accuracy with Option 761.25% +.25 V.25% +.45 V.25% +.6 V Accuracy with Option 76.25% +.45 V.25% +.6 V Maximum setting 55 V 22 V 66 V Response time Output Ripple and Noise: (PARD) 5 µs from occurrence of over-voltage condition to start of output shutdown CC rms: 2 ma 1 ma 4 ma Common Mode Noise: (from 2 Hz 2 MHz; from either output to chassis) rms 5 µa 5 µa 75 µa peak-to-peak < 2 ma < 2 ma < 3 ma Remote Sense Capability: Series and Parallel Operation: Outputs can maintain specifications with up to a 1-volt drop per load lead. The load lead drop reduces the maximum available voltage at the load. Identically rated outputs can be operated directly in parallel or be connected for straight series operation. Auto-series and auto-parallel operation is not available. Minimum Output Turn-On Delay: (Time from when any Output On command is received until the output starts turning on) Without relay option 32 ms NOTE 4 18 ms 18 ms With relay Option 76 58 ms NOTE 4 44 ms 44 ms 1 If you are operating the unit below 255 µa in constant current mode, the output may become unregulated with the following load conditions: The load resistance is <175 mω and the load inductance is >2 µh. If this occurs, an UNRegulated flag will be generated and the output current may rise above the programmed value but will remain less than 255 µa. 2 Correction On compensates for current flowing into the output capacitor during voltage transients 3 Modules can discharge the specified capacitive load from full scale to V at a rate of 4 times/second. 4 In Current priority mode, minimum delay is 23 ms without relays and 45 ms with relay Option 76. 3 N6731B-N6784A DC Power Modules Specifications Guide

Autoranging Characteristic Voltage 5 V N6761A / N6762A 5 W / 1 W Output Voltage 2 V 6 V N6763A / N6764A 3 W Output Voltage 2 V 6 V N6765A / N6766A 5 W Output 33 V Current 6 V 15 V 3 W curve Current 1 V 29 V 5 W curve Current 1 A 1.5 A 2 A 3 A - 5 W - 1 W 15 A 5 A 5 A 2 A 25 A 8.33 A 5 A 17 A Output Impedance Graphs 32 16 IMPEDANCE (milliohms) 8 4 2 1 5 2.5 Magnitude Phase 135 9 45-45 PHASE (degrees) 1 1k 1k FREQUENCY (Hz) 1k Model N6762A, CV Mode, @5V, 2A 8 Magnitude IMPEDANCE (ohms) 4 2 1.5.25 Phase 9 45-45 -9 PHASE (degrees).125 1 1k 1k FREQUENCY (Hz) 1k Model N6762A, CC Mode, @5V, 2A N6731B-N6784A DC Power Modules Specifications Guide 31

IMPEDANCE (milliohms) 8 4 2 1 5 2.5 1.25 Magnitude Phase 9 45-45 -9 8 4 2 1 5 2.5 1.25 Magnitude Phase 135 9 45-45 PHASE (degrees).62.62 1 1k 1k 1k FREQUENCY (Hz) Model N6763A and N6765A, CV Mode, @2 V, 15A 1 1k 1k 1k FREQUENCY (Hz) Model N6763A and N6765A, Option 76, CV Mode, @2 V, 15A IMPEDANCE (ohms).8.4.2.1.5.25 Magnitude Phase 45-45 -9.8.4.2.1.5.25 Magnitude Phase 9 45-45 -9 PHASE (degrees).125-135.125.62.62 1 1k 1k 1k FREQUENCY (Hz) Model N6763A and N6765A, CC Mode, @2 V, 15A 1 1k 1k 1k FREQUENCY (Hz) Model N6763A and N6765A, Option 76, CC Mode, @2 V, 15A 32 N6731B-N6784A DC Power Modules Specifications Guide

.8.8 IMPEDANCE (ohms).4.2.1.5.25.125 Magnitude Phase 9 45-45 -9.4.2.1.5.25.125 Magnitude Phase 9 45-45 -9 PHASE (degrees).62.62 1 1k 1k 1k FREQUENCY (Hz) Model N6764A and N6766A, CV Mode, @6 V, 5A 1 1k 1k 1k FREQUENCY (Hz) Model N6764A and N6766A, Option 76, CV Mode, @6 V, 5A IMPEDANCE (ohms) 8 4 2 1.5.25.125 Magnitude Phase 45-45 -9-135 8 4 2 1.5.25.125 Magnitude Phase 45-45 -9-135 PHASE (degrees).62.62 1 1k 1k 1k FREQUENCY (Hz) Model N6764A and N6766A, CC Mode, @6 V, 5A 1 1k 1k 1k FREQUENCY (Hz) Model N6764A and N6766A, Option 76, CC Mode, @6 V, 5A N6731B-N6784A DC Power Modules Specifications Guide 33

Arbitrary Waveform Generator Maximum Bandwidth NOTE The information in this section only applies when the power modules are installed in an Agilent N675 DC Power Analyzer. The following tables characterize the maximum bandwidth of the arbitrary waveform generator. The maximum bandwidth is based on a sine wave into a resistive load and apples to any output current. The following definitions apply in the frequency tables: V p-p = Voltage peak-to-peak 3 db max. = Max. frequency where the voltage drops to 3 db below its setting THD 3 db = The total harmonic distortion at 3 db max. frequency THD < 1.5% = The frequency below which the THD is less than 1.5%. Voltage 3 db max THD 3 db THD < 1.5% N6761A & N6762A.5 Vp-p 45 Hz 14% 45 Hz 1. Vp-p 36 Hz 14% 45 Hz 2.5 Vp-p 13 Hz 25% 34 Hz 5. Vp-p 6 Hz 25% 25 Hz 5. Vp-p 35 Hz 22% 3 Hz N6763A & N6765A.2 Vp-p 23 Hz 1% 13 Hz.4 Vp-p 15 Hz 15% 8 Hz 1. Vp-p 98 Hz 19% 48 Hz 2. Vp-p 58 Hz 21% 3 Hz 2. Vp-p 4 Hz 12% 32 Hz N6764A & N6766A.6 Vp-p 28 Hz 8.% 16 Hz 1.2 Vp-p 14 Hz 15% 8 Hz 3. Vp-p 6 Hz 17% 3 Hz 6. Vp-p 4 Hz 2% 2 Hz 6. Vp-p 344 Hz 12% 3 Hz 34 N6731B-N6784A DC Power Modules Specifications Guide

Chapter 5 Agilent N6781A, N6782A, N6784A Source/Measure Units Performance Specifications... 36 Supplemental Characteristics... 37 Output Quadrant Characteristic... 42 Output Impedance Graphs... 42 Unless otherwise noted, specifications are warranted over the ambient temperature range of to 3 C after a 3-minute warm-up period. Unless otherwise noted, specifications apply at the mainframe output terminals, with each module's sense terminals internally connected to its output terminals (local sensing). Refer to the Agilent N67 or N675 Service Guide for the setup conditions for all performance specifications. Supplemental characteristics are not warranted but are descriptions of performance determined either by design or by type testing. All supplemental characteristics are typical unless otherwise noted. N6731B-N6784A DC Power Modules Specifications Guide 35

Performance Specifications N6781A N6782A N6784A DC Ratings: Voltage 2 V / 6 V 2 V / 6 V ± 2 V / ± 6 V Current NOTE 1 ± 1 A / ± 3 A ± 1 A / ± 3 A ± 1 A / ± 3 A Power 2 W 2 W 2 W Auxiliary Voltage Measurement Input: ± 2 V Output Voltage Ripple & Noise (PARD) from 2 Hz 2 MHz: (Measured at front panel terminals, with full load, in Voltage Priority mode. Output Bandwidth setting = Low) CV peak-to-peak 12 mv 12 mv 12 mv CV rms 1.2 mv 1.2 mv 1.2 mv Load Effect (Load regulation): (For any load change, based on a load lead drop 1. V. The load lead drop reduces the maximum available voltage at the load.) Voltage, 2 V range 7 μv 7 μv 7 μv Voltage, 6 V range 4 μv 4 μv 4 μv Current, 3 A range 1 μa 1 μa 1 μa Current, 1 A range 5 μa 5 μa 5 μa Current 3 ma range 5 μa 5 μa Current 1 ma & 1 ma range NOTE 2 5 μa Source Effect (Line regulation): Voltage, all ranges 3 μv 3 μv 3 μv Current, all ranges 6 μa 6 μa 6 μa Programming Accuracy @ 23 C ±5 C: (After a 3 minute warm-up. Applies from minimum to maximum programming range at any load.) Voltage, 2 V range.25% + 1.8 mv.25% + 1.8 mv.25% + 1.8 mv Voltage, 6V range.25% + 6 μv.25% + 6 μv.25% + 6 μv Voltage 6 mv range NOTE 2.25% + 2 μv.25% + 2 μv.25% + 2 μv Current 3 A & 1 A range.4% + 3 μa.4% + 3 μa.4% + 3 μa Current 3 ma range NOTE 2.3% + 15 μa.3% + 15 μa Current 1 ma range NOTE 2.3% + 12 μa Current 1 ma range NOTE 2.25% + 5 μa Resistance for 2 V, 1 A output range.1% + 3 mω Resistance for 6 V, 3 A output range.1% + 1.5 mω Measurement Accuracy @ 23 C ±5 C: (Applies when measuring the default value of 4883 data points with a 2.48 μs time interval.) Voltage 2 V range.25% + 1.2 mv.25% + 1.2 mv.25% + 1.2 mv Voltage 1 V range.25% + 75 μv.25% + 75 μv.25% + 75 μv Voltage 1 mv range.25% + 5 μv.25% + 5 μv.25% + 5 μv Current 3 A range.3% + 25 μa.3% + 25 μa.3% + 25 μa Current 1 ma range.25% + 1 μa.25% + 1 μa.25% + 1 μa Current 1 ma range NOTE 3.25% + 1 na (11 na).25% + 1 na (11 na).25% + 1 na (11 na) Current 1 μa range NOTE 3.25% + 8 na (2 na).25% + 8 na (2 na).25% + 8 na (2 na) Auxiliary Voltage Measurement Input.25% + 5 mv Load Transient Response Time in Voltage Priority mode: (Time to recover to within settling band for a load change from.1 A to.9 A in the 2 V range; from.1 A to 1.5 A in the 6 V range.) Settling band for 2 V, 1 A output range ± 1 mv ± 1 mv ± 1 mv Settling band for 6 V, 3 A output range ± 2 mv ± 2 mv ± 2 mv Recovery time 35 μs 35 μs 35 μs 1 Output current is derated 1% per C above 3 C. 2 6 mv range is only available in Voltage Priority mode; 3 ma, 1 ma, 1 ma ranges are only available in Current Priority mode. 3 Values in parentheses apply when power modules are installed in Agilent N675A mainframes. 36 N6731B-N6784A DC Power Modules Specifications Guide

Supplemental Characteristics N6781A, N6782A N6784A Minimum Current and Voltage Compliance limits: Minimum current limit for 2 V range in Voltage Priority mode 1 ma 1 ma Minimum current limit for 6 V range in Voltage Priority mode 2 ma 2 ma Minimum voltage limit for 3 A range in Current Priority mode 1 mv 1 mv Minimum voltage limit for 1 A range in Current Priority mode 2 mv 2 mv Programming Range & Resolution: Voltage, 2 V range to 2.4 V; 2 μv -2.4 V to 2.4 V; 2 μv Voltage, 6 V range to 6.12 V; 6 μv -6.12 V to 6.12 V; 6 μv Voltage, 6 mv range to 612 mv; 6 μv -612 mv to 612 mv; 6 μv Current, 3 A range -3.6 A to 3.6 A; 5 μa -3.6 A to 3.6 A; 5 μa Current, 1 A range -1.2 A to 1.2 A; 5 μa -1.2 A to 1.2 A; 5 μa Current, 3 ma range -36 ma to 36 ma; 3 μa Current, 1 ma range -12 ma to 12 ma; 1 μa Current, 1 ma range -1.2 ma to 1.2 ma;.1 μa Resistance, for 2 V / 1 A range (N6781A only) -4mΩ to +1Ω;.5mΩ Resistance, for 6 V / 3 A range (N6781A only) -4mΩ to +1Ω;.25mΩ Programming Accuracy Temperature Coefficient (per C): Voltage, 2 V range.2% +12uV.2% +12uV Voltage, 6 V range.15% +4uV.15% +4uV Voltage, 6 mv range.15% +1uV.15% +1uV Current, 3 A range.25% +22uA.25% +22uA Current, 1 A range.25% +22uA.25% +22uA Current, 3 ma range.25% +14uA Current, 1 ma range.25% +1uA Current, 1 ma range.25% +.5 μa Measurement Resolution: Voltage, 2 V range 2 μv 2 μv Voltage, 1 V range 1 μv 1 μv Voltage, 1 mv range 1 μv 1 μv Current, 3 A range 5 μa 5 μa Current, 1 ma range 1 μa 1 μa Current, 1 ma range 1 na 1 na Current, 1 μa range.1 na.1 na Auxiliary Voltage Measurement Input (N6781A only) 8 μv Measurement Accuracy Temperature Coefficient (per C): Voltage, 2 V range.25% +25 uv.25% +25 uv Voltage, 1 V range.2% +2.5 uv.2% +2.5 uv Voltage, 1 mv range.25% +2.5 uv.25% +2.5 uv N6731B-N6784A DC Power Modules Specifications Guide 37

Supplemental Characteristics (continued) Measurement Accuracy Temperature Coefficient (continued) Current, 3 A range Current, 1 ma range Current, 1 ma range Current, 1 μa range Auxiliary Voltage Measurement Input (N6781A only) Voltage Programming Speed & Settling Time: N6781A, N6782A.25% +14 ua.25% +.4 ua.2% +5 na.2% +.55 na.7% +2 uv N6784A.25% +14 ua.25% +.4 ua.2% +5 na.2% +.55 na At the specified Bandwidth setting. Low High1 High2 High3 Low High1 High2 High3 Rise Time (from 1% to 9% of step) 2 V range with a -1 V step 6 V range with a -4 V step 6mV range with a -5 mv step Settling Time (to.1% of step) 2 V range with a -1 V step 6 V range with a -4 V step 6mV range with a -5 mv step High Frequency Output Voltage Noise: 3 μs 3 μs 4 μs 85 μs 85 μs 1.2 ms 15 μs 2 μs 75 μs 45 μs 55 μs 22 μs 2 μs 22 μs 3 μs 65 μs 65 μs 85 μs 12 μs 5 μs 5 μs 24 μs 16 μs 17 μs 3 μs 3 μs 4 μs 85 μs 85 μs 1.2 ms 15 μs 2 μs 75 μs 45 μs 55 μs 22 μs 2 μs 22 μs 3 μs 65 μs 65 μs 85 μs 12 μs 5 μs 5 μs 24 μs 16 μs 17 μs At the specified Bandwidth setting. Low High1 High2 High3 Low High1 High2 High3 CV peak-to-peak (from 2 Hz 2 MHz;) 2 V range with no load 6 V & 6 mv range with no load CV rms (from 2 Hz 2 MHz;) 2 V range with no load 6 V & 6 mv range with no load Low Frequency Output Voltage Noise: CV peak to peak (from.1 Hz 1 Hz) 2 V range 6 V range 6 mv range CV rms (from.1 Hz 1 Hz) 2 V range 6 V range 6 mv range Voltage Programming Small Signal Bandwidth: (All ranges) 12 mv 12 mv 1.2 mv 1 mv 12 mv 12 mv 1.2 mv 1 mv 4 mv 4 mv 4 mv 3 mv 12 mv 12 mv 12 mv 12 mv 4 mv 4 mv 4 mv 3 mv.5 mv.5 mv 1.2 mv 1.2 mv.5 mv.5 mv.3 mv.3 mv 1 mv 1 mv.3 mv.3 mv 1 μv 5 μv 2 μv 2 μv 1 μv 5 μv At the specified Bandwidth setting. Low High1 High2 High3 Low High1 High2 High3 3 db typical with no load cap with 1μF load cap with 6.8μF load cap with 15μF load cap 1 db typical with no load cap with 1μF load cap with 6.8μF load cap with 15μF load cap DC to DC to DC to DC to DC to DC to DC to DC to 1.4 khz 2.9 khz 7 Hz 1 khz 29 khz 6 khz 21 khz 4 khz 15 khz 22 khz 11 khz 14 khz 8.6 khz 14 khz 4.3 khz 6 khz 1.4 khz 2.9 khz 7 Hz 1 khz 29 khz 6 khz 15 khz 22 khz 21 khz 4 khz 11 khz 14 khz 8.6 khz 14 khz 4.3 khz 6 khz 38 N6731B-N6784A DC Power Modules Specifications Guide

Voltage Measurement Noise: Peak value 2 V range 1 V range 1 mv range Voltage Measurement Settling Time: (All ranges) Supplemental Characteristics (continued) N6781A, N6782A 3 mv 25 μv 5 μv N6784A 3 mv 25 μv 5 μv Settling Time with no range change 4 μs 4 μs Voltage Measurement Small Signal Bandwidth: (All ranges) 3 db typical with seamless ranging Off with seamless ranging On 1 db typical with seamless ranging Off with Seamless ranging On Auxiliary Voltage Measurement Input: (N6781A only) Differential input resistance Maximum continuous differential input without damage Maximum voltage from chassis common Maximum conversion rate Voltage Priority Transient Characteristic: (6 V range only) DC to 3 khz DC to 27 khz DC to 17 khz DC to 15 khz 1 MΩ ± 6 V ± 24 VDC 1k samples/second DC to 3 khz DC to 17 khz At the specified Bandwidth setting. Low High1 High2 High3 Low High1 High2 High3 At the specified Settling band. Recovery time with no load cap with 1μF load cap with 6.8μF load cap with 15μF load cap Current Programming Speed & Settling Time: Rise Time (from 1% to 9% of step) 3 A range with a -3 A step 1 A range with a -1 A step 3 ma range with a -3mA step 1 ma range with a -1mA step 1 ma range with a -1mA step Settling Time (to.1% of step) 3 A range with a -3 A step 1 A range with a -1 A step 3 ma range with a -3mA step 1 ma range with a -1mA step 1 ma range with a -1mA step High Frequency Output Current Noise: (All ranges) 4 mv 5 mv 3 mv 2 mv 4 mv 5 mv 3 mv 2 mv 3 μs 14 μs 1 μs 2 μs 2.8 μs 3.2 μs 3.5 μs 3 μs 3 μs 4 μs 1 μs 25 μs 15 μs 35 μs 3 μs 14 μs 1 μs 2 μs 2.8 μs 3.2 μs 4 μs 5 μs 3 μs 3 μs 3 μs 3 μs CC rms (from 2 Hz 2 MHz;) 2 μa 2 μa Low Frequency Output Current Noise: CC rms (from.1 Hz 1 Hz) 3 A & 1 A ranges 1 ma range 2 μa 5 na 1 μs 25 μs 15 μs 35 μs N6731B-N6784A DC Power Modules Specifications Guide 39

Supplemental Characteristics (continued) Current Programming Small Signal Bandwidth: (All ranges) 3 db - for all except 1 ma & 1 ma ranges - for 1 ma & 1 ma ranges 1 db - for all except 1 ma & 1 ma ranges - for 1 ma & 1 ma ranges Current Measurement Noise: Peak value 3 A range 1 ma 1 ma 1 μal Current Measurement Settling Time: Settling Time with no range change or when up-ranging 3 A range 1 ma range 1 ma range 1 μa range (up- ranging ) Settling Time when down-ranging down-ranging to 1 ma range down-ranging to 1 ma range down-ranging to 1 μa range N6781A, N6782A DC to 12 khz DC to 75 khz 4 μa 2 μa 2 μa 2 na 45 μs 45 μs.5 ms 1.5 ms 45 μs 2 μs 3.5 ms N6784A DC to 12 khz DC to 1 khz DC to 75 khz DC to 5 khz 4 μa 2 μa 2 μa 2 na 45 μs 45 μs.5 ms 1.5 ms 45 μs 2 μs 3.5 ms Current Measurement Small Signal Bandwidth: NOTE 1 3 db typical with seamless ranging Off 3 A range 1 ma range 1 ma range 1 μa range DC to 29 khz DC to 29 khz DC to 1 khz DC to 75 Hz DC to 27 khz DC to 27 khz DC to 1 khz DC to 75 Hz 3 db typical with seamless ranging On 3 A range 1 ma range 1 ma range 1 μa range DC to 26 khz DC to 26 khz DC to 1 khz 1 db typical with seamless ranging Off 3 A range 1 ma range 1 ma range 1 μa range DC to 16 khz DC to 16 khz DC to 6 khz DC to 4 Hz DC to 16 khz DC to 16 khz DC to 6.5 khz DC to 4 Hz 1 db typical with seamless ranging On 3 A range 1 ma range 1 ma range 1 μa range DC to 14 khz DC to 14 khz DC to 6 khz Common Mode Current from 2 Hz 2 MHz: (With output connected to chassis) CC peak-to-peak < 1 ma < 1 ma CC rms <1 μa <1 μa 4 N6731B-N6784A DC Power Modules Specifications Guide

Over-voltage Protection: Supplemental Characteristics (continued) N6781A, N6782A N6784A Accuracy.5% + 2 mv.5% + 2 mv Maximum setting 24 V 24 V Response time (From occurrence of over-voltage to start of shutdown) <3 µs <3 µs Current Priority Transient Characteristic: (3 A range) Voltage step 1 V to 4 V 1 V to 4 V Current settling band 5 ma 5 ma Recovery time NOTE 2 12 μs (24 μs) 2 12 μs (24 μs) Current Priority Transient Characteristic: (1 A range) Voltage step.5 V to 2 V.5 V to 2 V Current settling band 1 ma 1 ma Recovery time NOTE 2 12 μs (24 μs) 12 μs (24 μs) Remote Sense Capability: Series and Parallel Operation: Outputs can maintain specifications with up to a 1-volt drop per load lead. The load lead drop reduces the maximum available voltage at the load. Not supported Minimum Output Turn-on Delay: (Time from when any Output On command is received until the output starts turning on.) With output turn-off mode set to Low impedance 25.6 ms 25.6 ms With output turn-off mode set to High impedance 24.7 ms 24.7 ms 1 When using an Agilent N675A mainframe and connecting through the front panel binding posts, additional output capacitance causes large measurement peaking/overshoots when the load impedance is greater than ~1 kω. This does not apply to Agilent N675B mainframes. When using an N675A or N675B mainframe and connecting directly to the module connector, there are slight measurement peaking/overshoots when the load impedance is greater than ~1 kω. 2 Values in parentheses apply when power modules are installed in Agilent N675A mainframes. N6731B-N6784A DC Power Modules Specifications Guide 41

Output Quadrant Characteristic N6781A, N8782A, 2 W Voltage +2 V N6784A, 2 W Voltage +1 A +2 V +6 V +3 A +6 V -3 A -1 A Key Sourcing power +1 A +3 A Current -6 V -3 A Current Sinking power -2 V -1 A Note 1 Note 1. When sinking power, Agilent Model N6784A can operate at the maximum rated output power for only a limited amount of time. The unit monitors the temperature of the internal power devices and latches the output off if the output power causes the temperature to exceed its safe limit. A protect clear is required to resume normal operation. The condition is annunciated by the OT status bit. Refer to the downprogrammer derating figure for the values of the safe limit boundaries. Output Impedance Graphs 42 N6731B-N6784A DC Power Modules Specifications Guide

Chapter 6 Agilent N6783A-BAT, N6783A-MFG Application-Specific Power Modules Performance Specifications... 44 Supplemental Characteristics... 45 Output Quadrant Characteristic... 46 Unless otherwise noted, specifications are warranted over the ambient temperature range of to 4 C after a 3-minute warm-up period. Specifications apply at the output terminals, with each module's sense terminals internally connected to its output terminals (local sensing). Refer to the Agilent N67 or N675 Service Guide for the setup conditions for all performance specifications. Supplemental characteristics are not warranted but are descriptions of performance determined either by design or by type testing. All supplemental characteristics are typical unless otherwise noted. N6731B-N6784A DC Power Modules Specifications Guide 43

Performance Specifications N6783A-BAT N6783A-MFG DC Ratings: Voltage - 8 V - 6 V Current NOTE 1 2 to +3 A 2; to +3 A Power 24 W 18 W Low current measurement range 15 ma 15 ma Output Ripple and Noise (PARD): (from 2 Hz 2 MHz) CV peak-to-peak 8 mv 8 mv CV rms 1.5 mv 1.5 mv Load Effect (Regulation): (For any output load change, with a maximum load-lead drop of.5v/lead. The load lead drop reduces the maximum available voltage at the load.) Voltage 6 mv 6 mv Current 2 ma 2 ma Source Effect (Regulation): Voltage 2 mv 2 mv Current 1 ma 1 ma Programming Accuracy: (@ 23 C ±5 C after a 3 minute warm-up. Applies from minimum to maximum programming range at any load.) Voltage.1% + 1 mv.1% + 1 mv Positive Current.1% + 1.8 ma.1% + 1.8 ma Negative Current @ 2 A.2% + 1.8 ma Measurement Accuracy: (@ 23 C ±5 C. Applies when measuring the default value of 124 data points with a 2.48 μs time interval.) Voltage.5% + 5 mv.5% + 5 mv Current high range.1% + 6 µa.1% + 6 µa Current low range.1% + 75 µa.1% + 75 µa Load Transient Recovery (Time to recover to within settling band for a load change from.15 A to 1.5 A and from 1.5 A to.15 A at 6 V output) Voltage settling band NOTE 2 ± 75 mv ± 75 mv Time NOTE 2 < 45 µs < 45 µs 1 Output current is derated 1% per C above 4 C. 2 When relay Option 761 is installed, the settling band is ± 9 mv. The time is < 75 µs. 44 N6731B-N6784A DC Power Modules Specifications Guide

Supplemental Characteristics Programming Ranges: N6783A-BAT N6783A-MFG Voltage 15 mv to 8.16 V 15 mv to 6.12 V Positive Current 5 ma to 3.6 A 5 ma to 3.6 A Negative Current 5 ma to 2 A Fixed at 2 A Programming Resolution: Voltage 2.5 mv 2.5 mv Positive Current 1 ma 1 ma Negative Current 1 ma Measurement Resolution: Voltage 3 µv 3 µv Current high range 1 µa 1 µa Current low range (.15 A) 5 µa 5 µa Programming Temperature Coefficient per C: Voltage 25 ppm + 5 µv 25 ppm + 5 µv Current 25 ppm + 1 µa 25 ppm + 1 µa Measurement Temperature Coefficient per C: Voltage 25 ppm + 4 µv 25 ppm + 4 µv Current high range 25 ppm + 2.5 µa 25 ppm + 2.5 µa Current low range (.15 A) 25 ppm + 1.5 µa 25 ppm + 1.5 µa Maximum Up-Programming and Down-Programming Time with Full Resistive Load (Time from 1% to 9% of total voltage excursion) Voltage Settling from V to Full Scale 4. ms 4. ms Voltage Settling from Full Scale to V 4. ms 4. ms Maximum Up-Programming and Down-Programming Settling Time with Full Resistive Load (Time from start of voltage change until voltage settles within.1% of the full-scale voltage of its final value) Voltage Settling from V to Full Scale 2 ms 2 ms Voltage Settling from Full Scale to V 2 ms 2 ms Over-voltage Protection: Accuracy without disconnect relays.25% + 75 mv.25% + 75 mv Accuracy with disconnect relays.25% + 275 mv.25% + 275 mv Nominal range 1 V 1 V Programmable delay time 6 µs 5 ms 6 µs 5 ms Over-Current Protection: Programmable delay time 255 ms 255 ms Nominal Range 5 ma 3.6 A 5 ma 3.6 A Output Ripple and Noise: (PARD) CC rms: 4 ma 4 ma Common Mode Noise: (From 2 Hz 2 MHz; from either output to chassis) Rms 1 ma 1 ma Peak-to-peak 6 ma 6 ma N6731B-N6784A DC Power Modules Specifications Guide 45

Remote Sense Capability: Series and Parallel Operation: Supplemental Characteristics (continued) Down-programming Capability: (Current down-programming capability is reduced at output voltages below.5 V) N6783A-BAT N6783A-MFG Outputs can maintain DC specifications with up to a.5-volt drop per load lead. Maximum sense lead resistance is limited to 3mΩ/lead. Identically rated outputs can be operated directly in parallel. N6783A modules cannot be used in series with other N6783A modules or any other N67xx module. Auto-series and auto-parallel operation is not available. Continuous power 12 W 12 W Continuous current 2 A 2 A Output Quadrant Characteristic N6783A-BAT N6783A-MFG Voltage +8 V (BAT) +6 V (MFG) -2 A +3 A Current Key Sourcing power Sinking power Negative current not programmable on N6783A-MFG 46 N6731B-N6784A DC Power Modules Specifications Guide

Chapter 7 Agilent N67 Modular Power System Mainframes Supplemental Characteristics... 48 Outline Diagrams... 5 Supplemental characteristics are not warranted but are descriptions of performance determined either by design or by type testing. All supplemental characteristics are typical unless otherwise noted. NOTE Refer to the following documents for information about using and servicing the Agilent N67 Modular Power System Mainframes Agilent Model N675 DC Power Analyzer User s Guide Go to http://cp.literature.agilent.com/litweb/pdf/n675-91.pdf. Agilent Model N675 DC Power Analyzer Service Guide Go to http://cp.literature.agilent.com/litweb/pdf/n675-91.pdf. Agilent Series N67 Low-Profile Modular Power System User s Guide Go to http://cp.literature.agilent.com/litweb/pdf/5969-2937.pdf. Agilent Series N67 Low-Profile Modular Power System Service Guide Go to http://cp.literature.agilent.com/litweb/pdf/5969-2938.pdf. N6731B-N6784A DC Power Modules Specifications Guide 47

Supplemental Characteristics Maximum Power Available for Modules: Values represent combined power rating of all modules installed per mainframe. N67B, N671A, N672A 4 W (for N67B mainframes) 6 W (for N671A mainframes) 12 W (for N672A mainframes) N675A, N675B Front Panel Output Terminals: Maximum current rating 2 A BNC Trigger Connectors: I/O Maximum voltage Digital TTL level compatible 5 V USB Current Ratings: Front panel USB connector Rear panel USB connector 2 ma 3 ma Data Storage: Internal flash memory 8 Mbyte 4 Gbyte (Earlier N675 models have less memory) Protection Response Characteristic: INH input Fault on coupled outputs Command Processing Time: Digital Port Characteristics: Maximum voltage ratings 5 µs from receipt of inhibit to start of shutdown < 1 µs from receipt of fault to start of shutdown 1 ms from receipt of command to start of output change +16.5 VDC/ 5 VDC between pins (pin 8 is internally connected to chassis ground). 6 W Pins 1 and 2 as FLT output Pins 1-7 as digital/trigger outputs (pin 8 = common) Pins 1-7 as digital/trigger inputs and pin 3 as INH input (pin 8 = common) Interface Capabilities: GPIB LXI Compliance USB 2. 1/1 LAN Built-in Web server Maximum low-level output voltage =.5 V @ 4 ma Maximum low-level sink current = 4 ma Typical high-level leakage current = 1 ma @ 16.5 VDC Maximum low-level output voltage =.5 V @ 4 ma; 1 V @ 5 ma; 1.75 V @ 1 ma Maximum low-level sink current = 1 ma Typical high-level leakage current =.8 ma @ 16.5 VDC Maximum low-level input voltage =.8 V Minimum high-level input voltage = 2 V Typical low-level current = 2 ma @ V (internal 2.2k pull-up) Typical high-level leakage current =.12 ma @ 16.5 VDC SCPI - 1993, IEEE 488.2 compliant interface Class C (only applies to units with LXI label on front panel) Requires Agilent IO Library version M.1.1 or 14. and up Requires Agilent IO Library version L.1.1 or 14. and up Requires Internet Explorer 7+ or Firefox 2+ 48 N6731B-N6784A DC Power Modules Specifications Guide

Supplemental Characteristics (continued) Regulatory Compliance: EMC Safety Environmental Conditions Operating environment Temperature range Relative humidity Altitude Storage temperature Acoustic Noise Declaration: This statement is provided to comply with the requirements of the German Sound Emission Directive, from 18 January 1991. N67B, N671A, N672A N675A, N675B Complies with European EMC Directive for test and measurement products. IEC/EN 61326-1 CISPR 11, Group 1, class A AS/NZS CISPR 11 ICES/NMB-1 Complies with Australian standard and carries C-Tick mark. This ISM device complies with Canadian ICES-1. Cet appareil ISM est conforme à la norme NMB-1 du Canada. Complies with European Low Voltage Directive and carries the CE-marking. Conforms to UL 611-1 and CSA C22.2 611-1. Indoor use, installation category II (for AC input), pollution degree 2 C to 55 C (output current is derated 1% per C above 4 C ambient temperature) Up to 95% Up to 2 meters -3 C to 7 C Sound Pressure Lp <7 db(a), At Operator Position, Normal Operation, According to EN 27779 (Type Test). Schalldruckpegel Lp <7 db(a), Am Arbeitsplatz, Normaler Betrieb, Nach EN 27779 (Typprüfung). Output Terminal Isolation: Maximum rating N6781A Note AC Input: Input Ratings Power Consumption Power Factor Fuse N672A Note Net Weight: Mainframe with 4 modules (typical) Single-wide power module (typical) Dimensions: No output terminal may be more than ±24 VDC from any other terminal or chassis ground. When using the AUX measurement input terminals on Model N6781A, no output or input terminal may be more than ±6 VDC from any other terminal and chassis ground. ~ 1 VAC 24 VAC; 5/6/4Hz ~ 1 VAC 24 VAC; 5/6/4Hz 1 VA (N67B) 144 VA 144 VA (N671A) 144 VA (N672A @ < 18 VAC input) 22 VA (N672A @ > 18 VAC input).99 @ nominal input and rated power.99 @ nominal input and rated power Internal fuse - not customer accessible. Internal fuse - not customer accessible. AC mains circuits rated at 1-18 VAC cannot supply enough current to power the N672A mainframe when operated at its full rated power. When connected to a 1-18 VAC mains, internal circuits will limit the power available to modules to 6 W maximum. N67B 12.73 kg / 28 lbs N671A 11.82 kg / 26 lbs N672A 14.9 kg / 31 lbs 1.23 kg / 2.71 lbs Refer to the outline diagrams on the following page. 16 kg / 35 lbs 1.23 kg / 2.71 lbs N6731B-N6784A DC Power Modules Specifications Guide 49

Outline Diagrams 272.6 mm 1.733 in. = airflow 16.9 mm.663 in. 425.6 mm 16.756 in. 23.5 mm.923 in. 17.7 mm.697 in. 177. mm 6.968 in. 5 N6731B-N6784A DC Power Modules Specifications Guide