Agilent J7211A/B/C Attenuation Control Units

Similar documents
Two-Way Radio Testing with Agilent U8903A Audio Analyzer

Solutions for Solar Cell and Module Testing

N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes

Agilent U9397A/C FET Solid State Switches (SPDT)

Agilent 87222C/D/E Coaxial Transfer Switches dc to 26.5, 40, 50 GHz

UWB Antenna Measurements with the 20 GHz E5071C ENA Network Analyzer

Agilent N8480 Series Thermocouple Power Sensors. Technical Overview

Agilent U9391C/F/G Comb Generators

Agilent Maximizing Measurement Speed Using P-Series Power Meters

Agilent Correlation between TDR oscilloscope and VNA generated time domain waveform

Agilent 87075C Multiport Test Set

Keysight Technologies N9398C/F/G and N9399C/F DC Block. Technical Overview

Agilent 87405B. Preamplifier 10 MHz to 4 GHz. Technical Overview. Features. Benchtop/General Purpose Use

Agilent AN Balanced Circuit Measurement with an Impedance Analyzer/LCR Meter/Network Analyzer Application Note

Keysight Technologies 8490G Coaxial Attenuators. Technical Overview

Agilent NFA Noise Figure Analyzer

Agilent 8762F Coaxial Switch 75 ohm

Process Control Calibration Made Easy with Agilent U1401A

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Agilent E4438C/E8267D Option 422 Scenario Generator for GPS

Keysight Technologies U9391C/F/G Comb Generators. U9391C (10 MHz to 26.5 GHz) U9391F (10 MHz to 50 GHz) U9391G (10 MHz to 67 GHz) Technical Overview

Keysight Technologies P9400A/C Solid State PIN Diode Transfer Switches

Agilent 8761A/B Microwave Switches

Agilent U1881A and U1882A Power Measurement Application for Agilent InfiniiVision and Infiniium Oscilloscopes

Keysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview

Agilent MXG Signal Generators

Keysight Technologies N9398C/F/G and N9399C/F DC Block. Technical Overview

Keysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview

Techniques to Achieve Oscilloscope Bandwidths of Greater Than 16 GHz

Agilent N9310A RF Signal Generator. All the capability and reliability of an Agilent instrument you need at a price you ve always wanted

Agilent 87104/87106A, B, C Multiport Coaxial Switches dc to 4 GHz, dc to 20 GHz, dc to 26.5 GHz

Agilent MXG Signal Generators

Agilent N4000A, N4001A, N4002A SNS Series Noise Sources 10 MHz to 26.5 GHz

A Time-Saving Method for Analyzing Signal Integrity in DDR Memory Buses

Agilent E6651A Mobile WiMAX Test Set

Advanced Test Equipment Rentals ATEC (2832)

Agilent 84904, 6, 7K/L Programmable Step Attenuators

Advanced Measurement Techniques for RF Amplifiers Using Unique Functions of the Agilent E5071C ENA. Application Note

Solar Array Simulation System Integration

Multiport Solutions for E5071C ENA RF Network Analyzers Using External Switches. Application Note

Agilent U1240 Series Handheld Digital Multimeters

Agilent 81180A Arbitrary Waveform Generator

Agilent N9342C Handheld Spectrum Analyzer (HSA)

Agilent 87204/87206A, B, C Multiport Coaxial Switches dc to 4 GHz, dc to 20 GHz, dc to 26.5 GHz


Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Agilent U2000 Series USB Power Sensors. Data Sheet

Agilent N8262A P-Series Modular Power Meter and Power Sensors. Data Sheet

Agilent NFA Noise Figure Analyzer

Evaluating Oscilloscope Bandwidths for your Application

Agilent 4294A Precision Impedance Analyzer, 40 Hz to 110 MHz. Configuration Guide

MEMS On-wafer Evaluation in Mass Production Testing At the Earliest Stage is the Key to Lowering Costs

Keysight Technologies Active Differential Probes U1818A 100 khz to 7 GHz U1818B 100 khz to 12 GHz. Technical Overview

Keysight Technologies USB Preamplifiers

Agilent N8700 Series System DC Power Supplies

7 Hints That Every Engineer Should Know When Making Power Measurements with Oscilloscopes.

Agilent U1700 Series Handheld LCR Meters

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide

Discovering New Techniques of Creating, Editing, and Transferring Arbitrary Waveforms

Keysight Technologies PXI Programmable Step Attenuator Module

Agilent N9342C Handheld Spectrum Analyzer (HSA)

Agilent U3400 Series 4½ and 5½ Digit Digital Multimeters

Agilent N9320B RF Spectrum Analyzer

Agilent N1911A/N1912A P-Series Power Meters and N1921A/N1922A Wideband Power Sensors. Data sheet

Making a S11 and S21 Measurement Using the Agilent N9340A

MIL-STD 1553 Triggering and Hardwarebased Decode (Option 553) for Agilent s InfiniiVision Series Oscilloscopes


Educator s Oscilloscope Training Kit for the InfiniiVision 2000 & 3000 X-Series

Agilent U2741A USB Modular 5.5 Digits Digital Multimeter. Data Sheet

Essential Capabilities of EMI Receivers. Application Note

Agilent Spectrum Visualizer (ASV) Software. Data Sheet

Multipurpose Lab Station by Agilent Technologies

Agilent 2-Port and 4-Port PNA-X Network Analyzer

Agilent Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price. Data Sheet

Agilent Migration from the Agilent 34401A to the Agilent 34405A Digital Multimeter. Application Note

Agilent N9310A RF Signal Generator

N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes

Agilent E4428C and E4438C ESG Signal Generators

Agilent InfiniiMax III probing system

Agilent N4916B De-emphasis Signal Converter

N9051A Pulse Measurement Software

Keysight 8762F Coaxial Switch 75 ohm

Agilent NFA Noise Figure Analyzer

Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price

Keysight Technologies U9391C/F/G Comb Generators. U9391C (10 MHz to 26.5 GHz) U9391F (10 MHz to 50 GHz) U9391G (10 MHz to 67 GHz) Technical Overview

Agilent 86142B and 86146B Optical Spectrum Analyzers

Agilent E5061B Network Analyzer. 100 khz to 1.5 GHz/3 GHz 5 Hz to 3 GHz

MXG Analog Signal Generator Express Configurations

Keysight Technologies 87104/6D Multiport Electromechanical Coaxial Switches

Keysight Technologies Network Analyzer Measurements: Filter and Amplifier Examples. Application Note

Keysight N9310A RF Signal Generator

Agilent ENA 2 and 4 Port RF Network Analyzers

Data Sheet. Agilent M9185A PXI Isolated D/A Converter. DISCOVER the Alternatives... Agilent MODULAR Products. 8/16-Channel 16-bit, ±16 V

Keysight 86205B RF Bridge

Agilent 87415A, 87400A Microwave Amplifiers

Keysight Technologies 87222C/D/E Coaxial Transfer Switches

Keysight Technologies, Inc. Overcome PCB Loss and Deliver a Clean Eye to Your DUT Using Multi-tap De-emphasis

Keysight Technologies N9310A RF Signal Generator

Introduction. Part 1. Introduction...2

EM Insights Series. Episode #1: QFN Package. Agilent EEsof EDA September 2008

Transcription:

Agilent J7211A/B/C Attenuation Control Units DC to 6 GHz, DC to 18 GHz, DC to 26.5 GHz 0 to 101/121 db attenuation range, 1 db step size Technical Overview Key Features 0.03 db insertion loss repeatability per section for the entire 5 million cycles ensures accuracy and reduces calibration intervals Excellent attenuation accuracy and flatness ensure precise measurements Agilent calibrated data correction dislays the exact corrected attenuation value Attenuation sweep function enables the selection of application-specific dwell time and attenuation values LXI Class C compliance provides GPIB, USB and LAN connectivity for easy remote integration Relative attenuation step function allows attenuation to be set relative to any value

Description Agilent Technologies J7211A/B/C attenuation control units increase efficiency and throughput of benchtop and ATE testing of wireless components. An ideal solution for R&D and manufacturing, these standalone instruments offer a userdefined attenuation sweep function which lets you set the desired attenuation range, step size, number of cycles and attenuation configuration based on your application s requirements. This function, combined with excellent repeatability and accuracy, facilitates the design, validation and manufacture of WiMAX TM and WLAN components; and eases mobile handset base transceiver station (BTS) handover testing. Exceptional 0.03 db insertion loss repeatability per section with excellent attenuation accuracy and flatness ensure precise measurements. This reduces calibration intervals which lowers the cost of test for the entire 5 million lifecycle. Designed in a half-rack, 2 unit high-form factor, the J7211A/B/C are packed with features and functions that are easily accessible via the soft keys and the rotary knob located on the front panel. LXI Class C compliancy provides GPIB, USB and LAN connectivity for easy remote control and triggering. Calibration data is stored in the instrument s memory for fast, easy retrieval. Applications Mobile receiver sensitivity test Control PC Golden radio Golden transceiver RF Attenuation control unit DL UL Shielded fixture DUT Figure 1. Test setup for mobile receiver sensitivity test using a golden radio Control PC Communication test set RF Attenuation control unit DL UL Shielded fixture DUT Figure 2. Test setup for mobile receiver sensitivity test using a communication test set Figure 1 and 2 show test setups for measuring receiver sensitivity. The receiver sensitivity test measures a receiver s performance using known signal conditions including: modulation and coding type, SNR, and power input levels. Using the specified conditions, receivers must be able to decode data bits with a specified bit error rate (BER) at different input power levels. 2

Many manufacturers have opted to use costly, high-end signal generators to get accurate power levels across a wide range. However, although these instruments usually provide > 0.4 db accuracy, at lower power levels where receiver sensitivity tests are being carried out, the accuracy is often ± 1 db. The power level of the test signal is important as a small change in the input power level can greatly affect the BER performance of the receivers. For more information, refer to the application note Power Accuracy in Receiver Sensitivity Test, literature number 5989-8768EN. Figures 1 and 2 show you how to use an external attenuator to get fast and accurate power levels for mobile receiver sensitivity test. The J7211A/B/C attenuation control units are used with a signal generator to provide extremely accurate power measurements. Calibration can be done at one relatively high power level, for instance 0 dbm, and then the signal level is stepped down through the attenuation control unit. In this way, the power level from the source can be kept at a constant eliminating power level linearity problems in the test signal. Corrected attenuation data is provided at each attenuation level of the attenuation control unit s frequency range (from DC to 6/18/26.5 GHz), this gives you the exact input power level for each DUT. This also ensures test signal accuracy at very low power levels where a slight difference in the input test signal level has an adverse effect on DUT performance. The attenuation control unit s superb repeatability of 0.03 db per section ensures the accuracy and stability of the input power. Generally, this method improves amplitude accuracy, reduces the output noise floor of the test stimulus, and ensures a consistent and linear performance of the input signal regardless of its level. Because the packet error rate (PER) and frame error rate (FER) are highly sensitive to the input power level, this will have high impact on the yield of the receiver test. WiMAX 1 st adjacent channel interference Signal generator Test base station A BS Attenuator 1 Power combiner Directional coupler A SS Subscription station M BS M SS Test data to transmit Attenuator 2 Optional gating signal Average power meter Attenuator 3 Received data Figure 3. Test setup for 1 st adjacent channel interference Figure 3 shows the test setup for WiMAX 1 st adjacent channel interference. The adjacent channel interference test measures the signal in the adjacent channel to ensure that the receiver meets the specifications shown in Tables 1 and 2. 3

A connection between the test base station (BS) and the subscriber station (SS) is set up as shown in Figure 3. Attenuators 1 and 2 are used to adjust the signal level between the useful and interfering signals. Attenuator 3 is used to adjust the absolute signal level at the receiver and can be held at a constant value of 10 db. The signal generator transmits a signal on the first adjacent channel that is similar to the useful signal. The losses for the coupler and the connecting waveguides are measured and the attenuators are calibrated. When measuring the power, you need to take into account the effect of the coupler, the losses and the duty cycle. After the system is calibrated, set attenuator 2 to its maximum value and turn the signal generator off. The downlink QPSK data is generated and attenuator 1 is adjusted for BER = 10 3. See Tables 1 and 2. Increase the signal power by 3 db and measure the power. Switch the signal generator on and decrease the attenuator 2 until BER = 10 3 is achieved. Then turn off the test BS and measure the power of the interfering signal. The procedure is repeated for the other modulation schemes, 1 db degradation and BER = 10 6. Table 1. 1 st adjacent channel interference BER = 10-3 1 db degradation 3 db degradation QPSK -5 db -9 db 16-QAM +2 db -2 db 64-QAM +9 db +5 db Table 2. 1st adjacent channel interference BER = 10-6 1 db degradation 3 db degradation QPSK -1 db -5 db 16-QAM +6 db +2 db 64-QAM +13 db +9 db s s describe the instrument s warranted performance. Supplemental and typical characteristics are intended to provide information useful in applying the instrument by giving typical, but not warranted performance parameters. Product model J7211A J7211B J7211C Frequency range DC to 6 GHz DC to 18 GHz DC to 26.5 GHz Attenuation range 0 to 121 db 0 to 121 db 0 to 101 db Attenuation step size 1, 5 and 10 db 1, 5 and 10 db 1, 5 and 10 db Insertion loss (at 0 db) 2.5 db DC to 6 GHz: 2.5 db DC to GHz: 2.5 db 6 to 18 GHz: 5.0 db 6 to 18 GHz: 4.0 db 18 to 26.5 GHz: 5.0 db Return loss (VSWR) 14 db (1.50) DC to 6 GHz: 14 db (1.50) DC to 6 GHz: 16 db (1.35) 6 to 18 GHz: 10 db (1.90) 6 to 18 GHz: 11 db (1.78) 18 to 26.5 GHz: 7 db (2.61) RF repeatability per section 0.03 db 0.03 db 0.05 db Maximum power input 1 W (+30 dbm) Switching speed 20 ms Operating life 5 million cycles (guaranteed) Connectivity GPIB, USB, LAN (LXI Class C) Connector type SMA/Type-N SMA/Type-N 3.5 mm 4

J7211A/B/C Supplemental s and Characteristics Supplemental characteristics are intended to provide useful information. They are typical but non-warranted performance parameters. J7211A/B/C Attenuation Control Units Power 100 to 240 Vac, automatic selection, 50/60 Hz 50 VA maximum Main supply voltage fl uctuations are not exceed 10 percent of the nominal supply voltage Connector type Pin depth specifications s (mm) (inches) Type-N 50 ohm female 4.750 to 5.258 0.187 to 0.207 MIL-C-39012 SMA female 0.000 to 0.254 0.000 to 0.010 MIL-C-39012 3.5 mm female 0.000 to 0.076 0.000 to 0.003 IEEE STD 287 GPC Attenuation Accuracy (+/- db; referenced from 0 db setting) J7211A/B Attenuation setting for step ranges (db) DC to 6 GHz 6 to 18 GHz 1 to 2 0.3 0.7 3 to 4 0.4 0.7 5 to 6 0.5 0.8 7 to 10 0.6 0.8 11 to 20 0.7 1.4 21 to 40 1.2 2 41 to 60 1.8 2.8 61 to 80 2.4 3.6 81 to 100 3 4.4 101 to 121 3.3 5.3 Additional Functions Function Attenuation sweep function J7211C Attenuation setting for step ranges (db) DC to 6 GHz 6 to 18 GHz 1 to 2 0.35 0.4 3 to 6 0.55 0.7 7 to 10 0.7 0.8 11 to 20 1.2 1.4 21 to 40 1.4 1.6 41 to 60 1.9 2.5 61 to 80 2.5 2.7 81 to 101 3.7 4.0 Description Provides user-defi ned parameter setting for application-specifi c testing Key parameter settings: Delay time before START Attenuation range Attenuation step size (1 to 10 db; 1 db incremental) Attenuation start, stop and dwell time (100 ms to 10 s; 100 ms incremental) Number of attenuation cycles (1000 cycles maximum) Forward and backward attenuation cycles Relative attenuation step function Enables testing relative to any preset attenuation value Display of data correction value Displays correction value for attenuation using stored calibration data 5

Typical Performance 0-1 Insertion loss at 0 db Insertion loss (db) -2-3 -4-5 -6 5 10 15 20 25 30 Figure 4. Agilent J7211A attenuation control unit insertion loss (at 0 db) versus frequency 0-10 Return loss Return loss (db) -20-30 -40-50 -60 5 10 15 20 25 30 Figure 5. Agilent J7211A attenuation control unit return loss versus frequency 0-1 Insertion loss at 0 db Insertion loss (db) -2-3 -4-5 -6 2 4 6 8 10 12 14 16 18 Figure 6. Agilent J7211B attenuation control unit insertion loss (at 0 db) versus frequency 6

0-10 Return loss Return loss (db) -20-30 -40-50 -60 2 4 6 8 10 12 14 16 18 Figure 7. Agilent J7211B attenuation control unit return loss versus frequency 0-1 Insertion loss at 0 db Insertion loss (db) -2-3 -4-5 -6 5 10 15 20 25 30 Figure 8. Agilent J7211C attenuation control unit insertion loss (at 0 db) versus frequency 0-10 Return loss Return loss (db) -20-30 -40-50 -60 5 10 15 20 25 30 Figure 9. Agilent J7211C attenuation control unit return loss versus frequency 7

Environmental s Agilent J7211A/B/C attenuation control units are designed to fully comply with Agilent Technologies product operating environmental specifications. The following summarizes the environmental specifications for these products. Temperature: Operating 0 C to +50 C Storage 40 C to +70 C Humidity: Operating 95% RH at 40 C, 5 days cyclic Storage 90% RH @ 65 C, 25 hours Condensing 95% RH at 40 C, 5 hours (condensation 15 minutes) Shock: End-user handling Half-sine: 203 ms duration, 60 in/s (1.6 ms) delta-v Bench handling Per MIL-PRF-28800F Functional Half-sine: 11 ms duration, 30 grms Transportation Trapezoidal: 18-22 ms duration, 337 in/s (8.56 ms) delta-v Vibration: Operating Random: 0.21 Grms, 5 to 500 Hz, 10 min/axis Survival Random: 2.09 Grms, 5 to 500 Hz, 10 min/axis Swept-sine: 0.5 Grms, 5 to 500 Hz, 10 min/axis Altitude: Operating Non-operating < 4,572 meters (< 15,000 feet) < 4,572 meters (< 15,000 feet) Mechanical Information Dimensions are in mm (inches) nominal, unless otherwise specified. Figure 10. Product dimensions for J7211A/B (SMA connectors) J7211A/B product dimensions (SMA (f) connectors 1 ) Net weight 3.8 kg (8.4 lbs) Dimension (H x W x D) with 103.8 mm x 232.2 mm x 385.7 mm handle and rubber bumper (4.1 inches x 9.1 inches x 15.2 inches) Dimension (H x W x D) without 88.3 mm x 212.7 mm x 362.0 mm handle and rubber bumper (3.5 inches x 8.4 inches x 14.2 inches) 1. Only available for J 7211A/B. 8

Figure 11. Product dimensions for J7211A/B (Type-N connectors) J7211A/B product dimensions (Type-N (f) connectors 1 ) Net weight 3.8 kg (8.4 lbs) Dimension (H x W x D) with 103.8 mm x 232.2 mm x 398.4 mm handle and rubber bumper (4.1 inches x 9.1 inches x 15.7 inches) Dimension (H x W x D) without 88.3 mm x 212.7 mm x 374.7 mm handle and rubber bumper (3.5 inches x 8.4 inches x 14.6 inches) Figure 12. Product dimension for J7211C (3.5 mm connector) J7211C product dimensions (3.5 mm (f) connector 2 ) Net weight 3.8 kg (8.4 lbs) Dimension (H x W x D) with 103.8 mm x 232.2 mm x 385.7 mm handle and rubber bumper (4.1 inches x 9.1 inches x 15.2 inches) Dimension (H x W x D) without 88.3 mm x 212.7 mm x 362.0 mm handle and rubber bumper (3.5 inches x 8.4 inches x 14.2 inches) 1. Only available for J7211A/B. 2. Only available for J7211C. 9

Ordering Information J7211A Option 001 Option 002 Option UK6 Attenuation control unit, DC to 6 GHz, 0 to 121 db Type-N (f) connector SMA (f) connector Commercial calibration certifi cate with test data J7211B Option 001 Option 002 Option UK6 Attenuation control unit, DC to 6 GHz, 0 to 121 db Type-N (f) connector SMA (f) connector Commercial calibration certifi cate with test data J7211C 1 Option UK6 Attenuation control unit, DC to 26.5 GHz, 0 to 101 db Commercial calibration certifi cate with test data 1. 3.5 mm (f) connectors only. Ordering Information www.agilent.com/find/mta www.agilent.com/find/j7211 Related Literature Power Accuracy in Receiver Sensitivity Test Application Note, literature number 5989-8768EN. 10

Agilent Email Updates www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. www.lxistandard.org LXI is the LAN-based successor to GPIB, providing faster, more efficient connectivity. Agilent is a founding member of the LXI consortium. Agilent Channel Partners www.agilent.com/find/channelpartners Get the best of both worlds: Agilent s measurement expertise and product breadth, combined with channel partner convenience. Remove all doubt Our repair and calibration services will get your equipment back to you, performing like new, when promised. You will get full value out of your Agilent equipment throughout its lifetime. Your equipment will be serviced by Agilent-trained technicians using the latest factory calibration procedures, automated repair diagnostics and genuine parts. You will always have the utmost confidence in your measurements. Agilent offers a wide range of additional expert test and measurement services for your equipment, including initial start-up assistance, onsite education and training, as well as design, system integration, and project management. For more information on repair and calibration services, go to: www.agilent.com/find/removealldoubt www.agilent.com For more information on Agilent Technologies products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus Americas Canada (877) 894 4414 Latin America 305 269 7500 United States (800) 829 4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Thailand 1 800 226 008 Europe & Middle East Austria 43 (0) 1 360 277 1571 Belgium 32 (0) 2 404 93 40 Denmark 45 70 13 15 15 Finland 358 (0) 10 855 2100 France 0825 010 700* *0.125 /minute Germany 49 (0) 7031 464 6333 Ireland 1890 924 204 Israel 972-3-9288-504/544 Italy 39 02 92 60 8484 Netherlands 31 (0) 20 547 2111 Spain 34 (91) 631 3300 Sweden 0200-88 22 55 Switzerland 0800 80 53 53 United Kingdom 44 (0) 118 9276201 Other European Countries: www.agilent.com/find/contactus Revised: October 1, 2009 WiMAX, Fixed WiMAX, Mobile WiMAX, WiMAX Forum, the WiMAX Forum logo, WiMAX Forum Certified, and the WiMAX Forum Certified logo are trademarks of the WiMAX Forum. Product specifications and descriptions in this document subject to change without notice. Agilent Technologies, Inc. 2008, 2009 Printed in USA, October 27, 2009 5989-8323EN