DA850. The all around power DECATHLON

Similar documents
Switching Power Supply SPECIFICATION

OP650 -P. Single rail stepping up to a higher gear OP SERIES

SPECIFICATION. SilverStone Zeus ST75ZF. Switching Power Supply. With Active PFC PS/2 750W

SPECIFICATION SilverStone ST30NF for Standard Switching Power Supply With Active PFC PS/2 Fanless 300W

SSD3000 MODULE 280 WATT 12V FRONT END 8.66 x 1.99 x x 50.5 x 40mm

NIGHTJAR SERIES SST-ST45NF. Optimum fan-less power supply with stability and silence

IS -500RSH1UP. Redundant Power Supply ( 1U- 500W ) SPECIFICATION. Revision: 1.0

AED500H22S Power Supply Product Specification. An APM Electronics USA, Inc. Power Supply Specification For ERP1U Power Supply

AEA300R22S / AEA400R22S-1 Power Supply Product Specification

SPECIFICATION ARP

IX-500R8PD8. Redundant Power Supply ( PS2 MINI - 500W+500W ) SPECIFICATION. Revision: 1.0

SPECIFICATION. SilverStone OLYMPIA OP1000 Switching Power Supply Active PFC

SFX Form Factor SST-SX650-G SST-SX500-G. The standard SFX power supply benchmark

TC-600PD2. Switching Power Supply ( 600W PS2 ATX12V ) SPECIFICATION. Revision: 1.0

ST-250MAK-05E. Switching Power Supply SPECIFICATION

SPECIFICATION SWITCHING POWER SUPPLY BPS-300SP/2U 6-OUTPUT WITH ACTIVE PFC FUNCTION SINGLE POWER 300W BEST POWER SOLUTIONS, INC.

SPECIFICATION SWITCHING POWER SUPPLY SINGLE POWER 250W BEST POWER SOLUTIONS, INC. 9F, NO.196-7, SEC.3, TA-TUNG RD SHI CHIH, TAIPEI, TAIWAN, R.O.C.

SPECIFICATION REDUNDANT POWER SUPPLY HOT-SWAPPABLE 370W+370W

Compliance. Safety Approvals USA Canada Europe. Isolation: General. Dimensions. AC Input CN1 Output CN2 Optional CN3. Weight

PET NA FEATURES DESCRIPTION DATA SHEET

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

STRIDER ESSENTIAL SERIES SST-ST50F-ES230 Power for everything you need

SPECIFICATION REDUNDANT POWER SUPPLY HOT-SWAPPABLE BPS-460RDX 6-OUTPUT 460W+460W BEST POWER SOLUTIONS, INC.

Electrical Specifications

SPECIFICATION. SilverStone. 300W SFX Switching Power Supply FSP300-60GHS Meet 80 Plus Active PFC Circuit Full Range Input Small Size

Electrical Specifications Input

Product Specification

Matrix Power Company MH xxx-va series Specification Document

These medical power supplies are ideal for monitoring, home health equipment as well as surgical devices.

PDAM500 Series 500W Power Supply

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 115VAC to 78% at 90VAC)

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

Electrical Specifications

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

The MBC550 range is ideally suited to a wide variety of medical applications, and also where airflow is limited or not available.

5 x 3 x 0.75 Inches form factor. 275 Watts with Forced Air Cooling. Efficiencies up to 92% Standby Power < 0.5 W

TC-2U70PD8. Switching Power Supply ( 2U 700W 80PLUS) SPECIFICATION. Revision: 2.0

18093-PS PHIHONG TECHNOLOGY CO., LTD. General Specification PSM (DC)

TC-750PD8. Switching Power Supply ( PS2 ATX750W 8 0 PLU S ) SPECIFICATION. Revision: 1.0

150 Watt Industrial (WLT)

Electrical Specifications. Input Current 115 VAC: 1.2 A max. 230 VAC: 0.65 A max.

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

VOF XX - XXX - X

Sirius 250/350 Watts, Single / Multi output AC-DC, modular power solution

C B. Models. Models 2MOPP

Industrial Serie +600S

LB115S 115W Single Output

Doc. EA Model Number:

Output Power Output Voltage (3) Output Current Total Regulation (2) Efficiency (5) Model Number (1,6) 8 W 3.3 VDC 2.50 A 7% 68% AEL15US03 (4) 12 W

LFWLP W 12V 15.00A 25.00A 92%

3 in 1 Dimmable (0-10Vdc, PWM signal, or resistance)

ABC Series power supplies are ideal for telecom, datacom, industrial equipment and other applications.

DDP400 SERIES KEY FEATURES DESCRIPTION MARKET SEGMENTS AND APPLICATIONS

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

Watts HCP Series

SPECIFICATION ESD FSP500-60GHC. Released Date:2012/12/26-15:25:33

Medical / Industrial AC-DC Power Supply 1200W with 5V/2A Standby / MEB-1K2A series

General. Environmental. EMC & Safety

420 W High Line Output Power. Rugged Industrial Construction. -40 C to +70 C Operation. 5 V Standby. Screw Terminals. SEMI F47 Compliant

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

Model and Output Power Output Nominal Voltage Package Option Means of Protection Grade. 12 V DC: -US12 Open Frame: -OF. 24 V DC: -US24 U-Chassis: -UC

These medical power supplies are ideal for, monitoring, home health equipment as well as surgical devices.

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

This convection-cooled series is designed for use in commercial and industrial environments in temperatures up to 50 C.

SPECIFICATION ESD FSP300-60GHT,(85)F. Released Date:2016/05/18-15:38:12

SPECIFICATION ESD FSP600-80PSA(SK) Released Date:2017/02/08-10:47:01

HEC-100RTA-48QSCA Rev A1.0

70 Watt Switching Medical Grade Switching Power Supply with Active PFC CONTENTS 1. GENERAL CIRCUIT TOPOLOGY...2

HEC-45LTN-45PFAS Rev A

Features. Regulated Converter. RAC02-SE/277/W 2 Watt Single Output. RAC02- SE/277/W Wired. AC/DC Converter

AC/DC Power Supply Series APPLICATION NOTE

HEC-150RTN-48QSCA. A. Features. B. Description. C. Models. D. Electronic Specifications - Input Specifications

POWER DS Watts Distributed Power System. Data Sheet

ECP225-A Series. 225 Watts. AC-DC Power Supplies. Models & Ratings

Line Reg Load Reg Ripple Efficiency *Model Number Output V Output I (nom/max) (nom/max) & Noise (min/nom)

SPECIFICATION ESD FSP460-60HCN. Released Date:2011/04/01-15:26:46

ABC Series power supplies are ideal for telecom, datacom, industrial equipment and other applications.

NLP65 SERIES 75 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.26

IP67 DESCRIPTION KEY FEATURES MARKET SEGMENT AND APPLICATIONS TRC ELECTRONICS, INC

REDUNDANT AC 300W POWER SUPPLY. Technical Specifications TD-AC-300W-MAX

TECHNICAL DATASHEET MDS Medical AC-DC Open Frame 065APS18 B Highlights & Features Safety Standards Model Number: Unit Weight Dimensions (W x L x H):

Features. Regulated Converter. RAC02-SE/277 2 Watt Single Output RAC02- SE/277. AC/DC Converter

Electrical Specifications. Adjustment range Main output ± 5% Total regulation (line and load) ± 2.0% ± 5.0% Turn-on 120 Vac Input 2.0 s max.

AC/DC Power Supply Series APPLICATION NOTE

CLP0112 Open Frame Power Supply Vac input; 12Vdc output; 150W Output Power

HEC-30/35LTA-33TDAA Rev A

SPECIFICATION ESD Released Date:2012/12/20-10:56:04

Series AMSRL1-78JZ Up to 12 Watt DC-DC Switching Regulator

Medical Safety Approvals (-M versions) Industrial Heavy Duty Terminals. Output Power up to 1500 W. High Power Density - 18W/in 3

HEC-35LTA-XXTSAA Rev A

NEVO+1200M. 6 x6 x W. 1.2kg DATA SHEET MAIN FEATURES

The MDU150 Series provides the same benefits as the MPU150 Series, with nominal 48 volt DC input.

Power Factor (2) 600 ma 90 ~ 305 Vac Vdc 34.2 W 86% 0.95 LUC-040S060RSP. Efficiency (2) Parameter Min. Typ. Max. Notes

3 x 2 x 0.75 Inches Form factor. PCB Mount option available. 40 Watts Convection. Approved to EN/IEC Efficiencies 85% Typical

General. Environmental. EMC & Safety

Note1: Efficiency is tested at nominal input and full load at +25 C ambient Note2: Max Cap Load is tested at nominal input and full resisitive load

Features. Regulated Converters. RACM Watt Enclosed Case Style Single Output. RACM150- S/ _ Fan Option (1) Single. AC/DC Converter.

Transcription:

DECATHLON DA80 The all around power Class-leading single rail with 70A @ 0 C 00% modular cables Dual PCI-E 8 pin connector & quad PCI-E 6 pin connectors Quiet running 0mm fan Support for ATX V. & EPS V Active PFC Efficiency greater than 80%

0 SPECIFICATION SilverStone DECATHLON DA80 Switching Power Supply With Active PFC PS/ Modular 80W. General This is the specification of Model DA80; it is intended to describe the functions and performance of the subject power supply. This PS/ 80 watts switching power supply with Active PFC (Power Factor Correction) capability, meets EN6000-- and equips Full Range Input features.. AC Input Specifications -. AC Input Voltage, Frequency and Current ( Rating: 00V-0Vac, 7-6Hz, -7A ) The power supply must operate within all specified limits over the input voltage range in Table. Harmonics distortion of up to 0% THD must not cause the power supply to go out of specified limits. Parameter Voltage (V) Voltage (0V) Frequency Minimum 90 Vac 80 Vac 7 Hz Norminal 00-0Vac 00-0Vac 0 / 60 Hz Maximum Vac 6Vac 6 Hz Max. Current A 7A Table - AC Input Voltage and Frequency -. AC Inrush Current The power supply must meets inrush requirements of any rated AC voltage, during turn on at any phase of voltage, during a single cycle AC dropout condition, during repetitive On/Off cycling of AC, and over the specified temperature range. The peak inrush current shall be less than the rating of its critical components (including input fuse, bulk rectifiers, and surge limiting device). -. Input Power Factor Correction ( Active PFC) The power factor at full load shall be 0.99 at nominal input voltage. -. Input Current Harmonics When the power supply is operated in 90-6Vac of Sec.., the input harmonic current drawn on the power line shall not exceed the limits set by EN6000-- class "D" standards. The power supply shall incorporate universal power input with active power factor correction. -. AC Line Dropout An AC line dropout of 7 or less shall not cause any tripping of control signals or protection circuits. If the AC dropout lasts longer than 7 the power supply should recover and meet all turn on requirements. The power supply shall meet the regulation requirement over all rated AC voltages, frequencies, and output loading conditions. Any dropout of the AC line shall not cause damage to the power supply. An AC line dropout is defined as a drop in AC line to 0VAC at any phase of the AC line for any length of time. < -

DECATHLON DA80. DC Output Specification -. Output Current / Loading The following tables define two power and current rating. The power supply shall meet both static and dynamic voltage regulation requirements for minimum load condition. Output Voltag Max. Load Min. Load +V 0A.0A +.V 8A 0A 70A A -V 0.A 0A Max. Combined 80W 70A Total Output 80W 6W Table - Output Loads Range Note Maximum continuous total DC output power should not exceed 80 W. +VSB A 0.A 0W -. DC Voltage Regulation, Ripple and Noise The power supply output voltages must stay within the following voltage limits when operating at steady state and dynamic loading conditions. All outputs are measured with reference to the return remote sense (ReturnS) signal. The +V,+.V,, -V and +VSB outputs are measure at the power supply connectors references to ReturnS. The +V and +.V is measured at its remote sense signal (+VS, +.VS) located at the signal connector. Output Voltage +V +.V -V +VSB Load Reg. +/-% +/-% +/-% +/-0% +/-% Line Reg. ±% ±% ±% ±% ±% Ripple & Noise 0mV 0mV 0mV 0mV 0mV Table 7 - Regulation, ripple and noise. Ripple and Noise shall be measured using the following methods: a) Measurements made differentially to eliminate common-mode noise b) Ground lead length of oscilloscope probe shall be 0. < - inch. c) Measurements made where the cable connectors attach to the load. d) Outputs bypassed at the point of measurement with a parallel combination of 0uF tantalum capacitor in parallel with a 0.uF ceramic capacitors. e) Oscilloscope bandwidth of 0 Hz to 0MHz. f ) Measurements measured at locations where remote sense wires are connected. g) Regulation tolerance shall include temperature change, warm up drift and dynamic load -. Timing Requirements These are the timing requirements for the power assembly operation. The output voltages must rise from 0% to within regulation limits (Tvout_rise) within to 70. The +V, +.V and output voltages should start to rise at about the same time. All outputs must rise monotonically. The +V output needs to be greater than the +.V output during any point of the voltage rise. The +V output must never be greater than the +.V output by more than.v. Each output voltage shall reach regulation within 0 (Tvout_on) of each other during turn on of the power supply. Each output voltage shall fall out of regulation within 00 (Tvout_off) of each other during turn off. Figure and figure show the turn On and turn Off timing requirement. In Figure, the timing is shown with both AC and PSON# controlling the On/Off of the power supply. 0

Item Description MIN MAX Units Tvout rise Output voltage rise time from each main output.(+vsb < 70) 70 Tvout on All main output must be within regulation of each other within this time. 0 Tvout off All main output must leave regulation within this time Table 0 - Output Voltage 00 Item Tsb on-delay Description Delay from AC being applied to +VSB being within regulation. MIN MAX 00 Units Tac on-delay Delay from AC being applied to all output voltages being within regulation. 00 Tvout holdup All main output voltage stay within regulation after loss of AC 8 Tpwok holdup Delay from loss of AC deassertion of PWOK. 7 Tpson on delay Delay from PSON# active to output voltage within regulation limits. 00 Tpson pwok Delay from PSON# deactive to PWOK being deasserted. 0 Tpwok on Delay from output voltage within regulation limits to PWOK asserted at turn on. 00 00 Tpwok off Delay from PWOK deasserted to output voltages (+V, +.V, ) dropping out of regulation limits. Tpwok low Duration of PWOK being in the deasserted state during an off/on cycle using AC or the PSON# signal.. 00 Tsb vout Delay from +VSB being in regulation to O/Ps being in regulation at AC turn on. Table - Turn On/Off Timing 0 000 0

DECATHLON DA80 AC Input AC Off AC On Vout Tvout_holdup Tac_on-delay Tpwok_low Tsb_on-delay PWOK Tpwok_on Tpwok_off Tpwok_holdup Tsb_on-delay Tpwok_on Tpwok_off Tpson_pwok +VSB Tsb_vout Tsb_holdup Min.>70 PSON# Tpson_on_delay AC turn on/off cycle PSON turn on/off cycle Figure : Turn On/Off Timing -. Remote On/Off Control : PSON# The PSON# signal is required to remotely turn on/off the power supply. PSON# is an active low signal that turns on the +V, +.V, and -V power rails. When this signal is not pulled low by the system, or left open, the outputs (except the +VSB and V bias) turn off. This signal is pulled to a standby voltage by a pull-up resistor internal to the power supply. Type PSON# = Low PSON# = High Accepts an open collector/drain input from the system. Pull-up to VSB locted in power supply. Power ON Power OFF Table - PWOK Characteristic -. Efficiency The efficiency is specified at 0% and 0% loading conditions to help reduce system power consumption at typical system loading conditions. Loading 00% of maximum 0% of maximum 0% of maximum Minimum 77% 80% 7% -6. +VSB (Standby) The +VSB output is always on (+V Standby) when AC power is applied and power switch is turned on. The +VSB line is capable of delivering at a maximum of A for PC board circuit to operate. 0

. Protection Protection circuits inside the power supply shall cause only the power supply's main outputs to shutdown. If the power supply latches off due to a protection circuit tripping, either a AC cycle OFF for sec, or PSON# cycle HIGH for sec must be able to restart the power supply. -. Over Current Protection This power supply shall have current limit to prevent the +V, +.V, and outputs from exceeding the values shown in table. The current limit shall not trip under maximum continuous load or peak loading as described in Table. The power supply shall latch off if the current exceeds the limit. The latch shall be cleared by toggling the PSON# signal or by cycling the AC power. The power supply shall not be damaged from repeated power cycling in this condition. The -V and +VSB outputs shall be shorted circuit protected so that no damage can occur to the power supply. Voltage +V +.V Minimum 0% 0% 0% Maximum 60% 60% 60% Shutdown Mode Latch Off Latch Off Latch Off Table -Over Current protection -. Over Voltage Protection The power supply shall shut down in a latch off mode when the output voltage exceeds the over voltagelimit shown in Table. Voltage +V +.V VSB Minimum +.7V +.9V +.V.7 Maximum +6.V +.V +.V 6. Shutdown Mode Latch Off Latch Off Latch Off Auto recovery Table -Over Voltage protection. -. Short Circuit Protection The power supply shall shut down in a latch off mode when the output voltage is short circuit.. Environmental Requirements -. Temperature Operating Temperature Range: 0 ~ 0 ( ~ ) Non-Operating Temperature Range: -0 ~ 70 (-0 ~ 8 ) 0

DECATHLON DA80 -. Humidity Operating Humidity Range: Non-Operating Humidity Range: 0% ~ 90%RH non-condensing % ~ 9%RH non-condensing 6. Agency Requirements 6-. Safety Certification. Product Safety: RFI Emission: PFC Harmonic: Flicker: Immunity against: -Electrostatic discharge: -Radiated field strength: -Fast transients: -Surge voltage: -RF Conducted -Voltage Dips and Interruptions UL 6090-000Edition, IEC6090-, rd Edition EU Low Voltage Directive (7//EEC) (CB) TUV, CCC FCC Part ( Radiated & Conducted Emissions ) CISPR, rd Edition / EN0: 998 + A: 000) EN6000--:000 EN6000--: 99 + A: 00 EN0: 998 + A: 00 and A: 00 -IEC 6000-- -IEC 6000-- -IEC 6000-- -IEC 6000-- -IEC 6000--6 -IEC 6000-- Table 6 -Safety Certification 6-. AC Input Leakage Current Input leakage current from line to ground will be less than.ma rms. Measurement will be made at 0 VAC and 60Hz. 7. Reliability 7-. Mean Time Between Failures (MTBF) The MTBF of the power supply shall be calculated utilizing the Part-Stress Analysis method of MIL7F or Bell core RPP. The calculated MTBF of the power supply shall be greater than 00,000 hours under the following conditions: Full rated load 0V AC input Ground Benign 7- Warranty Three () years manufacture's warranty. Technical information in this specification is subject to change without notice. The revision of specification will be marked on the cover. 06

8. Connections 8-. AC Input Connector The AC input connector shall be an IEC 0 C- power inlet. This inlet is rated for A/0 VAC. 8-. DC Wire Harness and Connector Requirements (Subject to change without notice; please see appendix: wireharness drawing) P: Motherboard Power Connector Connector housing: - Molex 7 (No.9-0-0) or Equivalent Contact: Molex 6T (No.76-) or Equivalent +. VDC Orange +. VDC Orange + VDC Red 6 + VDC Red 7 8 PW_OK Gray AWG 9 VSB Purple 0 Yellow/Blue stripe Yellow/Blue stripe +. VDC Orange +. VDC;+. VRS+ Orange / Brown / AWG - VDC Blue 6 PS_ON# Green AWG 7 8 9 0 N/C -- -- + VDC Red + VDC ;+ VRS+ Red; Red ; AWG + VDC Red 07

DECATHLON DA80 P: Processor Power Connector Connector housing: 8- Molex 7 (9-0-080) or Equivalent Contact: Molex 6T (9-00-009) or Equivalent 6 7 8 Yellow/black stripe Yellow/black stripe Yellow/ stripe Yellow/ stripe Baseboard Power Connector Connector housing: - Molex 7 (9-0-00) or Equivalent Contact: Molex 6T (9-00-009) or Equivalent Yellow Yellow - HDD / CD-ROM Drive Power Connectors Connector housing: - AMP: -80-0 or Molex 898-0P or Equivalent Contact: Amp 6- or Equivalent + VDC Red Small - : Floppy Disk Drive Power Connectors Connector housing: - AMP: 78- or Equivalent + VDC Red AWG AWG AWG AWG 08

Serial ATA Power Connector This is a required connector for systems with serial ATA devices. Molex Housing #6780000 or Equivalent Molex Terminal #670000 or Equivalen +VDC RED +.VDC Orange Workstation Power Connector for High Power Graphics Cards For workstation systems with high-powered graphics cards an additional power connector to the baseboard may be needed. This connector supplies additional power for the higher power level graphics cards used in workstation applications. Connector housing: 6-pin Molex 9-000 or equivalent Contacts: Molex 9-00-007 or equivalent PCI-Express 6-6 PCI-Express 8-6 7 8 09

DECATHLON DA80 9. Physical Characteristics 9. Power Supply Dimension: 0 mm(w) x 86 mm(h) x 80 mm(d) Mechanical drawing: Please refer to the attached sketch. 0

November, 006 NO.G00