LIGHTNING ARRESTOR. September 2017 WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED

Similar documents
TECHNICAL SPECIFICATION

POTENTIAL TRANSFORMER

SPECIFICATION No SS-135/ kv METAL OXIDE SURGE ARRESTERS WITHOUT GAPS

GENERAL TECHNICAL SPECIFICATION (Turnkey Work)

CAPACITOR VOLTAGE TRANSFORMER

GENERAL TECHNICAL SPECIFICATION

شركة كهرباء محافظة القدس المساهمة المحدودة JERUSALEM DISTRICT ELECTRICITY CO. LTD.

1.0 mh, 3150 A LINE TRAP

EARTHING TRANSFORMER

Type DMX-N Surge Arresters Maximum System Voltage 2 to 36 kv

36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE)

Energy Division. Bowthorpe LV/MV Surge Arresters

COMBINED METERING TRANSFORMERS (OUT DOOR TYPE) FOR 11kV & 33kV SYSTEMS

Technical Specification For 33 KV, Single Phase, Dead Tank Type Out Door Current Transformer Of Different Ratio

TECHNICAL SPECIFICATION OF ELECTRICAL MATERIALS CT & PT GROUP C

EE 1402 HIGH VOLTAGE ENGINEERING

TECHNICAL DESCRIPTION TD-77A/3 170 KV COMPACT GAS INSULATED INTEGRATED SUBSTATION MODULES

TECHNICAL SPECIFICATION FOR 22 KV CURRENT TRANSFORMERS

AMENDMENT NO. 1 SEPTEMBER IS (Part 1) : 2001/IEC (1991) SURGE ARRESTORS

GTP NO-16 GUARANTEED TECHNICAL PARTICULARS FOR 33kV, 200A, 50 Hz AB SWITCH, 3 POLE, SINGLE BREAK TYPE

Effective February 2017 Supersedes January 2012 (CP1122)

S. C. Electric Cooperative s Specification for a Single-Phase, Single Bushing Overhead Distribution Transformer (Revised 10/2013)

Secondary Arresters. Figure 1. Type L secondary surge arrester rated 175 Vac, 125 Vdc.

VariSTAR Type AZL heavy-duty distribution-class MOV arrester

TECHNICAL SPECIFICATION FOR 11KV, 3C x95mm mm 2 AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED)

MGVCL/MM/ /2082/11KV AB CABLE TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES

51-SDMS-02 SPECIFICATIONS FOR DISTRIBUTION TRANSFORMERS UP TO 36KV 400/230 VOLTS

COOPER POWER. UltraSIL Polymer-Housed VariSTAR Type U2Surge Arrester for Systems through 275 kv IEC 10-kA; Line Discharge Class 2 SERIES

Our experience. Our products

Technical Specification. for 1.1 KV Copper Control Cable

Title: Southern States Type SLS Smart Sectionalizer Solid Dielectric Three Phase Sectionalizer. Product Specification Guide TABLE OF CONTENTS

SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA)

GURANTEED TECHNICAL PARTICULARS OF BACK CLAMP FOR LT CROSS ARM

Analysis of Major Changes to Arrester Standards IEC STEVE BREWER

The NOVA Recloser shall be designed and tested in accordance with the following standards as applicable:

SPECIFICATION SS-140/9. 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION AND PVC JACKET

400 kv EARTHING SWITCH

XLPE CABLE (33KV) September Engineering Department WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED

VI 3 - i TABLE OF CONTENTS

GUJARAT ENERGY TRANSMISSION CORPORATION LTD. SARADAR PATEL VIDYUT BHAVAN, RACE COURSE, BARODA TECHNICAL SPECIFICATIONS

3EK8 distribution class surge arresters. Catalogue HP-AR Version siemens.com/arresters

SPTS 1 - Ratings and General Requirements for Plant, Equipment and Apparatus for The ScottishPower System and Connection Points to it.

TECHNICAL SPECIFICATION OF 11 KV THREE PHASE FOUR WIRE, THREE CTs COMBINED METERING CTPT SET OF ACCURACY CLASS 0.5s

Insulation Co-ordination For HVDC Station

50-SDMS-01 SPECIFICATIONS FOR

Substation Design Volume VII

1.1_KV PVC insulated PVC sheathed multicore Aluminium Cable (armoured & unarmoured)

Eaton s Cooper Power Series DEADFRONT ARRESTERS

CHAPTER 10 HIGH VOLTAGE TESTING OF ELECTRICAL APPARATUS

012: 2015 CEB SPECIFICATION GALVANIZED STEEL WIRE (EXCEPT SHIELDING WIRE FOR TOWER LINE APPLICATION)

Device Under Test: ALTEA VS- 24-I VS-24-I. 0 24/09/12 First issue A. Peretto L. Peretto 1 24/06/16 All text review E. Scala L. Peretto J. L.

INTERNATIONAL STANDARD

The Variable Threshold Neutral Isolator (VTNI)

TS RES - OUTSTANDING ISSUES

(TECHNICAL SPECIFICATIONS & GTP FORMATS) 11KV METERING UNITS

Surge Arresters. VariSTAR Type AZS Normal Duty Distribution Class MOV Arrester

APDRP SCHEME, WESCO. Technical Specification for Distribution Transformers ( 11/0.4KV ) PART 1: GENERAL

All the standards referred to the most current issue, including all amendment supplements. as of the date of the bid.

IEC Type Test Report Report No. EU1517-H-00.1 H4 Series Porcelain-housed Arrester 20,000 A Line Discharge Class 4

SOUTHERN ELECTRICITY SUPPLY COMPANY OF ODISHA LIMITED (SOUTHCO UTILITY)

MINISTRY OF ELECTRICITY

51-SDMS-04 SPECIFICATIONS FOR. DISTRIBUTION TRANSFORMERS UP TO 36 kv WITH ALUMINUM WINDINGS FOR DUAL SECONDARY 400/230 V AND 230/133 V

Form-IV. Form of Inspection/Test Report. (Under Regulation 43)

TECHNICAL SPECIFICATION OF LT SHACKLE BOLT (G. I. BOLT) WITH NUT AND SPRING WASHER

CEYLON ELECTRICITY BOARD SRI LANKA. Procurement of Plant

SUPPLY OF CARRIER PROTECTION COUPLER TYPE NSD-50

A Review Comprehension: Guideline for Testing of HV, EHV and UHV Substation Equipment

ELECTRICAL NETWORKS SPECIFICATION TECHNICAL SPECIFICATION FOR A 230V/110V AND 400V/110V TRANSFORMER

High voltage engineering

Transformers connected via a cable Overvoltage protection

WIRELESS INSULATOR POLLUTION MONITORING SYSTEM

UltraSIL Polymer-Housed VariSTAR Normal-Duty, Heavy-Duty and Riser Pole Distribution-Class Arresters

PROCEDURE FOR INSPECTION OF ELECTRICAL INSTALLATIONS ABOVE 250KVA

SURGE ARRESTERS AND TESTING. Keith Hill Doble Engineering Company

11-SDMS-03 REV. 02 SPECIFICATIONS FOR

7. INSPECTION AND TEST PROCEDURES

SPECIFICATION FOR 11 KV CLASS, 24/15.7, 30/19.7 & 45/29.5 AMPS SPECIAL DESIGN TRANSFORMERS.

Tab 8 Surge Arresters

Gas-Insulated Medium-Voltage Switchgear siemens.com/8dab12

The RSM shall be extensively used in field & laboratory for verification of the accuracy of all types of single-phase energy meters.

NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata , Tel : ; Fax :

TECHNICAL SPECIFICATION OF 11 KV AND 22 KV THREE PHASE FOUR WIRE, THREE

SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches

UltraSIL Polymer-Housed Evolution Distribution Class Surge Arrester Certified Test Report

3. COMBINED TRANSFORMERS Oil-paper insulation

CEYLON ELECTRICITY BOARD SRI LANKA. Procurement of Plant

Plant Client Contract Code Document ID Contract No. TECHNICAL SPECIFICATIONS DC SHUNT Rev 00 Page 1 of 2

Single-Phase Mini Pad-Mounted Transformer Specification: Energy+ MPDL

Comparison of CAN/CSA C88.1, IEEE C /01 & IEC 60137

VBS TBS KTS BSS LFS UFS

Technical Specifications for Portable 3-Ø Power Analyzer

VariSTAR Type AZU heavy-duty distribution-class under-oil MOV surge arrester

ANSI DESIGN TEST REPORT Report No. EU1295-H-00 Type PVN Station Class Surge Arrester

3EE2 Special-Purpose Surge Arresters for the Protection of Motors, Generators and Furnace Transformers

WESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868)

POSI-BREAK Metal Oxide Varistor Elbow (M.O.V.E.) Surge Arrester

Group F : Sl. No. - 1) 33/0.403 KV, 100 KVA Station Transformer GUARANTEED & OTHER TECHNICAL PARTICULARS. Table : A

EI HIGH VOLTAGE INSULATION TESTING POLICY

Howard Smart Transformer Specification Guide

EE High Voltage Engineering UNIT IV - MEASUREMENT OF HIGH VOLTAGES AND HIGH CURRENTS PART-A 1. Mention the techniques used in impulse current

Transcription:

LIGHTNING ARRESTOR September 2017 Engineering Department WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED Regd. Office: VidyutBhawan, Block DJ, SectorII, Bidhannagar, Kolkata 700091. CIN: U40101WB2007SGC113474; Website: www.wbsetcl.in WBSETCL / TECH SPEC / Rev.2 Page 1 of 11 Lightning Arrestor

TECHNICAL SPECIFICATION FOR LIGHTNING ARRESTORS 1. SCOPE : a) This Specification covers design, manufacture, testing at manufacturer's Works of all classes of gapless Lightning Arrestors complete with fittings and accessories. b) These arrestors shall be of heavy duty, station class and gapless zinc Oxide type. c) Arrestors shall be hermetically sealed units suitable for outdoor installation on selfsupporting base or structures to be supplied by the bidder. 2. STANDARD : Arrestors shall conform in general to IEC994 document or its latest amendment and IS/IEC as follows: i) IEC994 : Gapless Lightning Arrestor ii) IS 3070 PIII : Metal Oxide Surge Arrestors without gaps for AC Systems. iii) IEC 99 PIII : Artificial Pollution Testing of Lightning Arrestor iv) IEC 270 : Partial Discharge Measurement. v) IS 2071 : Methods of H V Testing vi) IS 6209 : Methods for Partial Discharge Measurement vii)is 5621 : Hollow Insulators for use in electrical equipments 3. I) DEVIATION : Normally the offer should be as per Technical Specification without any deviation. II) MODIFICATION : If any modification felt necessary to improve performance, efficiency and utility of equipment, the same must be mentioned in the 'Modification schedule' with reasons duly supported by documentary evidences and advantages. Such modifications suggested may or may not be accepted, but the same must be submitted along with PreBid Queries. The modifications not mentioned in Schedule will not be considered. 4. DUTY REQUIREMENT : The Surge Arrestors are being provided to protect the following equipment whose insulation levels are indicated in the table given below : WBSETCL / TECH SPEC / Rev.2 Page 2 of 11 Lightning Arrestor

Equipment to be protected Power Transformer Instrument Transformer Circuit Breaker Isolator Phase to ground Isolator Across open poles Switching surge (KVp) for 420KV System L1 for 420KV System (KVp) L I for 245 KV system (KVp) L I for 145 KV system (KVp) L I for 36 KV system (KVp) ± 1050 ± 1300 ± 950 ±550 ±170 ± 1050 ± 1425 ± 1050 ±650 ±170 ± 1050 ± 1425 ± 1050 ±650 ±170 ± 1050 ± 1425 ± 1050 ±650 ±170 ± 900 (/+ 345) ± 1425 (/+ 240) ±1200 ±750 ±195 Reactor ± 1050 ± 1300 XLPE cable ± 1050 ± 1425 ± 1050 ±650 ±170 a) The Lightning Arrestors shall be capable of discharging Lightning and switching surges and temporary power frequency over voltages.the Surge Arrestor shall be capable of discharging over voltages occurring during switching of unloaded transformers, Reactors and long lines. b) The Arrestors shall be capable of withstanding Maximum Continuous Operating Voltages (M.C.O.V). c) The Arrestors supplied shall be suitable for heavily polluted atmosphere. d) The reference current of the Arrestors shall be high enough to eliminate the influence of grading and stray capacitance on the measured reference voltages. e) The Surge Arrestor shall be suitable for duty cycle of circuit breaker in this system. 5. FITTINGS & ACCESSORIES : a) Arrestors of rating 120 KV and above shall be complete with insulating base for connection to surge counter having provision for bolting to flat surface of structure. Arrestor rating of 42 KV shall be directly mounted on structure as there is no surge counter. b) For arrestors of rating 120 KV and above, selfcontained discharge counters suitably enclosed for outdoor use shall be provided for each single pole unit and placed on the Arrestor Structure, but requiring no auxiliary or battery supply for operation. The Cyclometer counter reading shall clearly visible through an inspection window. The counter terminals shall be robust and of adequate size and shall be so located that incoming and outgoing connections can be made with minimum no. of bends. The inspection window shall be sealed instead of screwed to prevent ingress of moisture. c) Suitable leakage current monitor on each pole of the arrestors with appropriate connections shall be supplied to measure leakage currents, for monitoring of 120 KV and above class of arrestor. The reading of Milliammeter and counters shall be visible through an inspection glass panel. WBSETCL / TECH SPEC / Rev.2 Page 3 of 11 Lightning Arrestor

d) Grading ring/corona ring shall be provided for Arrester rating of 120KV & above arrester for achieving linear voltage distribution along the Arrester column. Material of Grading ring/corona ring shall be of Al or better quality material. e) Each single pole arrestor shall be provided with suitable name plate, at the base with the following data: i) Name of device ii) Manufacturer's name and trade mark, type and identification iii) Year of manufacture iv) Voltage rating & frequency rating. v) Nominal discharge current vi) MCOV (Maximum Continuous Operating Voltage in KV). vii) Discharge class. viii) Energy Discharge capability (KJ/KV rating) ix) Purchase Order reference. x) Applicable Standard. xi) Pressure Relief current in KA rms (for arrestors fitted with Pressure Relief device) xii) Serial Number f) Required connectors and fixtures for L.A. leakage current monitor and discharge counter shall be supplied along with the L.As. g) Terminal connector shall be suitable for either ACSR Moose (single moose or double moose as per requirement) / ACSR Panther conductor for 400KV, 220 KV, 132 KV and 33 KV system voltage class L.A. having universal take off. Detailed particulars of Clamps and Connectors shall be guided by the specification for Clamps and Connector in this bid document. h) Two ground terminal suitable for G.I flat of required sizes shall be provided on diagonally opposite sides. i) Necessary hardware such as nuts, bolts, spring washers, etc. shall be supplied for different units. j) Surge monitor consisting of discharge counter and milliammeters should be suitable to be mounted on Support Structure of the arrester and should be tested for IP:55 degree of protection. Surge Monitors shall be connected in series with Surge Arrestor at a height approx. 1.5 meter from ground level. The cable used for connecting Surge Arrestor to Surge Monitor and ground is to be insulated from the structure by insulated cable. 6. CONSTRUCTIONAL FEATURES : a) The arrestor elements shall be designed in such a way as to obtain robust construction with excellent mechanical and electrical properties even after repeated operation. The lightning arrestors should be adequately designed to operate satisfactorily under temporary power frequency over voltage as given in Specific Technical Parameters, after discharging two shots of respective long duration surges. Uniform density of zinc oxide element shall be maintained to provide uniform current distribution. b) The lightning Arrestors shall be of adequate Pressure Relief Class as per IEC994, fitted with Pressure Relief Devices and Arc diverting ports to minimise possibilities of shattering of porcelain housing and providing path for flow of rated fault currents in the event of arrestor failure. c) Sufficient creepage distance shall be provided to reduce excessive uneven voltages over the porcelain due to contamination, for which the arrestor shall not fail. WBSETCL / TECH SPEC / Rev.2 Page 4 of 11 Lightning Arrestor

d) Seals shall be provided in such a way that these are always effectively maintained even when discharging the maximum rated lightning current. e) Housing Insulators shall be of porcelain, glazed and completely vitrified and free from blow holes, microcracks or voids.porcelain housing shall be so coordinated that external flashover will not occur due to application of any impulse or switching surge voltage up to the maximum design value for the arrestor. f) The end fittings shall be made of nonmagnetic and corrosion proof material. LAs shall be hermetically sealed. Arrestors shall be suitable for mounting on a support structure. g) There shall be minimum number of arrestor units for lightning arrestors of 120 KV rating and above. For 42KV and below single arrestor unit is preferred. 7. APPLICATION : The lightning Arrestors are used for protection of incoming and outgoing line and also of the power transformers from lightning surge as well as from power frequency over voltage. 8. GROUNDING TERMINALS : Two grounding terminals on diagonally opposite sides of adequate size suitable for connecting G.S. Flat of 50 10mm shall be provided for all voltage classes. 9. GUARANTEE: Electrical characteristics shall be guaranteed by the bidder. In case of failure of materials to meet the guarantee, WBSETCL shall have right to reject the material. Guaranteed Technical Particulars are to be submitted by successful bidder during detailed engineering alongwith submitted drawings/documents. However format for submission of GTP shall be handed over to intending bidders at the time of sale of tender documents. 10. CONTRACT DRAWINGS AND MANUALS : A. In the event of placement of L.O.A., six (6) copies of drawings and descriptive literatures shall be furnished for approval : a) General Outline drawing showing plan, elevation and end views with dimensions & full mounting details with weights. b) Dimensional Drawing showing the Arrestor mounted on its base and where applicable with surge counter and leakage current measuring meter. c) Details of Bushing top terminals. d) Shipping dimension with weights. e) Position of Centre of gravity and clearances with adjacent grounded metallic structures. f) Diagram plate showing electrical connections of the surge counter and leakage current measuring meter where applicable. WBSETCL / TECH SPEC / Rev.2 Page 5 of 11 Lightning Arrestor

g) Diagram plate showing electrical connections of the surge counter and leakage current measuring meter where applicable. h) Rating Plate. i) Complete foundation drawings for the structure of Lightning arrestor, where applicable. B. Four (4) sets of approved drawings and operation and maintenance manuals both in hard and soft copy shall be submitted for our record and distribution to site. 11. TEST AT FACTORY AND TEST CERTIFICATES : a) Each LA. shall comply with the requirements of routine test as specified in the relevant IEC:994 & IS:3070 (Part III). b) All Routine test at manufacturer's works shall be carried out for all LA s and Test reports are to be submitted. c) All acceptance tests shall be carried out at the manufacturer's works on every lot offered for inspection as per relevant IEC & IS in presence of representative of WBSETCL. Selection of samples for acceptance test as well as rejection and retesting shall be guided by relevant IEC & IS. The entire cost of acceptance and routine tests that are to be carried out as per relevant IEC & IS shall be treated as included in quoted price of LA. Three (3) copies of test reports shall be submitted for approval and adequate extra copies for distribution to site. d) The contractor shall give at least 15 (fifteen) days advance notice intimating the actual date of inspection and details of all tests that are to be carried out. 12. TEST REPORTS AND TYPE TESTS : Only type tested L.A s are to be offered for 400KV, 220KV, 132KV & 33KV System Voltage conforming to our technical specification and relevant IS and IEC. L.A offered should be similar with ones on which type testing has been carried out as per relevant IS and IEC. Three sets of complete type test reports carried out in Govt. recognized Test House or Laboratory /NABL accredited laboratory shall have to be submitted by successful bidder positively alongwith submission of drawings during detailed Engineering. Successful bidder may require to produce original copies type test reports at the time of detail Engineering if asked by WBSETCL. Each type test report shall comply the following information with test result i) Complete identification, date and serial no. ii) iii) Relevant drawings as documented with test report. Method of application, where applied, duration and interpretation of each test. WBSETCL / TECH SPEC / Rev.2 Page 6 of 11 Lightning Arrestor

SPECIFIC TECHNICAL PARAMETERS SNO DESCRIPTION TECHNICAL PARAMETERS TYPE OF ARRESTOR STATION CLASS HEAVY DUTY GAPLESS i) Nominal system voltage (KV) 400 220 132 33 ii) Highest system voltage (KV) 420 245 145 36 iii) System Neutral Earthing EE EE EE Earth with Earthing Transformer iv) BIL of transformers (KVp) 1300 900 550 170 v) System fault level (KA) for 3 40 31.5 25 50 for 1 sec. sec. For 3 sec. For 3 sec. For 3 sec. vi) Lightning Impulse withstand voltage for arrestor housing (KVp) 1425 1050 650 170 i) Rated Voltage (KV) 360or as specified in the schedule 198 120 42 ii) Maxm. Continuous operating voltage (KVrms) 306 168 102 36 iii) Nominal Discharge Current (KAp) of 8/20 micro second 10/ 20 10 10 10 wave iv) Line discharge class 3 3 3 2 v) Minimum Energy Discharge capability (KJ/KV) at rated voltage. 10 7.5 7.5 5 vi) Temporary over voltage 360 or as specified withstand capability (KVrms) in the schedule for 10.0 secs 198 120 42 vii) Insulation Housing withstand voltages i) Lightning Impulse(Dry) ii) Power frequency(wet) As per IEC 600994 for 10 KA for 5 KA viii) Minimum creepage Distance (mm) 10500 6125 3625 900 ix) Pressure Relief Class A x) (Minimum) High Current Impulse withstand (4/10 micro second wave) KA (peak) 100 100 100 100 xi) Maxm. Lightning Impulse(8/20 microsecond Wave) residual voltage (KVp) 5KA 10KA 800 850 517 550 320 340 112 120 xii) Maxm. switching surge(30/60 microsecond wave) protective level (KVp) WBSETCL / TECH SPEC / Rev.2 Page 7 of 11 Lightning Arrestor

500 Amps 1000 Amps 2000 Amps xiii) Maxm. Steep Impulse(1/20 MS impulse) residual voltage at 10 KA (KVp) xiv) Partial Discharge(picocoulomb) when energized at 1.05 times its continuous operating voltage. 750 455 280 1050 600 372 130 Not exceeding 10 PC xv) Rated Frequency (Hz) 50 xvi) Minm. visible corona discharge voltage (KVrms) 320 98 xvii) Min. Bending load (kgm) 1000 1000 500 500 xviii) 1 min. p.f. withstand (KVrms) voltage (dry & wet) for 630 460 275 70 arrestor housing xix) Switching Impulse withstand voltage (250/2500 micro second) dry & wet for arrestor housing (KVp) ±1050 xx) Pressure relief Current i) High Current (KA rms) 40 40 40 40 ii) Low Current (KA rms) As per IEC WBSETCL / TECH SPEC / Rev.2 Page 8 of 11 Lightning Arrestor

GUARANTEED TECHNICAL PARTICULARS FOR LIGHTNING ARRESTORS (To be filled in and signed by the Bidder) SL DESCRIPTION FOR 400 KV FOR 220 KV FOR 132KV FOR 33KV 1 LA : GENERAL 1.01 Name of Manufacturer 1.02 Type & Model of the Manufacturer 1.03 Conforming Standard 1.04 Date of Last Type Test 1.05 Diameter of Primary Stud (mm) 1.06 Total Height of the LA 1.07 Total Weight of the LA 1.08 No. of Units per Arrestor 2 LA: VOLTAGE 2.01 Rated voltage of Units 2.02 MCOV 2.03 Switching Surge Impulse withstand voltage with 250/2500 micro sec. wave(kvp) 2.04 Lightning Impulse Residual voltage (KVp) (8/20 microsecond wave) 2.05 Temporary over voltage capability (KVrms) 2.05.1 0.1 seconds 2.05.2 1.0 seconds 2.05.3 10.0 seconds 2.05.4 100.00 seconds WBSETCL / TECH SPEC / Rev.2 Page 9 of 11 Lightning Arrestor

2.05 Residual voltage after passing a steep current (1 microsecond front time) with amplitude equal to Nominal Discharge Current 2.06 Residual voltage for switching impulse currents (front time of about 30 to 60 microseconds) in KV crest at 500/1000 Amps 2.07 Maximum RIV at 1.1 Ur/ 3 voltage at 1 MHz ( Micro volts) 3 LA: CURRENT 3.01 Nominal Discharge Current (KAp) (for a 8/20 microsecond wave) 3.02 High current Impulse withstand capacity(4/10 microsecond) in Kap 3.03 Ir at MCOV 3.04 Ic at MCOV 4 LA : ENERGY 4.01 Minimum energy discharge capability(kj/kv) at 4.02 Long duration discharge class 4.03 Pressure Relief Class 5 Protective Ratio based on Transformer/Reactor BIL. 5.01 5000 Amps 5.02 10,000 Amps 6 LA: HOUSING 6.01 Material of Housing Insulator 6.02 Total Creepage Distance of whole Arrestor housing (mm) 6.03 Cantilever strength of complete Arrestor(Kgf) 6.04 L.A. Housing Insulation Withstand (KV) WBSETCL / TECH SPEC / Rev.2 Page 10 of 11 Lightning Arrestor

6.05 Dry(P.F) 6.06 Wet (P.F) 6.07 Lightning Impulse (Dry) 6.08 Partial Discharge in Pico Coulomb 6.09 Corona Extinction Voltage (KVrms) 6.10 Type of Surge Monitor 6.11 Each ZNO Block Dimensions WBSETCL / TECH SPEC / Rev.2 Page 11 of 11 Lightning Arrestor