Low Voltage AIRGUARD. A proven, rugged product for harsh environments

Similar documents
LV AIRGUARD. P r o ble m. ife? No S. a proven, rugged product for harsh environments

Top Drive Service Loops. Conventional, Enhanced and Superior Solutions for Drilling Applications

CORFLEX VFD CORFLEX VFD Part Number: Drive Cable

CIR (Crush & Impact Resistant) VFD Power Cable

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

14 AWG 2 AWG: 600 Volt

3/C UL AIRGUARD UL Type MV-105 (Replacement for Continuously Corrugated and Welded (CCW) Type Cables*)

CCW. Continuously Corrugated Welded Cable. Armored Cable for Hazardous Locations

VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS

3/C UL AIRGUARD UL Type MV-105 (Replacement for Continuously Corrugated and Welded Type Cables*)

METAL CLAD WIRING SYSTEM

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

DLO Flexible Power Cable

AIRGUARD CATALOG. Low and Medium Voltage Cable Products and Accessories

AIRGUARD CATALOG. Low and Medium Voltage Cable Products and Accessories

600 Volt MULTICONDUCTOR XLPE MC Low Voltage Commercial & Industrial Cables

INDUSTRIAL CABLES DESIGNED FOR LONGER SERVICE LIFE IN HARSH ENVIRONMENTS

GEXOL WORLD CLASS OIL & GAS CABLES

VFD CABLES 100% EMI CONTAINMENT HIGHLY FLEXIBLE & DURABLE

600 Volt MULTICONDUCTOR EPR MC Low Voltage Commercial & Industrial Cables

n 100% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible

Instrumentation Cables

CCW Continuously Corrugated Welded Cable ARMORED CABLE FOR HAZARDOUS LOCATIONS

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

ÖLFLEX FORTIS 55 Highly Flexible and Extremely Oil-Resistant Tray Cable; -40 C Flexible/-55 C Stationary

OLFLEX. Flexible Tray Cable MARYLAND METRICS. LAPP products are available from

MEDIUM VOLTAGE

5-46kV 3/C TRXLPE ARMORTEK Medium Voltage Commercial & Industrial Cables

SIMpull THHN, it slips and slides - all with NoLube.

5-35kV 1/C EPR MV-105 POWER (Tape Shield) Medium Voltage Commercial & Industrial Cables

THHN12STGN500 THHN 12 STR Green 500

THHN2BK2500 THHN 2 STR Black 2500

Descriptions RoHS Compatible; Applicable Standard ASTM B3, ASTM B8, ASTM B787, Federal Specification A-A-59544, NFPA 70, NEMA WC-70

THHN12S0LWHBL500 THHN 12 Sol White/Blue Striped 500

Descriptions RoHS Compatible; Applicable Standard ASTM B3, ASTM B8, ASTM B787, Federal Specification A-A-59544, NFPA 70, NEMA WC-70

TIGER BRAND MINING CABLES

THHN6WH500 THHN 6 STR White 500. Features Conductor Size Current Rating 55 AMPERE (60 DEG C), 65 AMPERE (75 DEG C), 75 AMPERE (90 DEG C)

SKINTOP ÖLFLEX CLICK & VFD CLICK FLEX. Products for Variable Frequency Drive Applications. ake the right connection

MV-105 Power. (Tape Shield) 5-35kV 1/C EPR. Design Parameters. Description. Options. Installations

Addison Medium Voltage Cables

Over 35 Years of Service. Our Commitment. Dedicated to Our Customers. Product Expertise and Specialized Services. Strategic Partnerships

Extremely Oil-Resistant & Flexible Tray Cable with UL & CSA; Unshielded & Shielded. Complete the Installation. SKINTOP Strain Relief page 488

CATALOG OF PRODUCTS. Your Best Supplier of Electrical Cables

Medium Voltage Power Cables

Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking

5-35kV 1/C TRXLE MV-90 POWER (wire shield) Medium Voltage Commercial & Industrial Cables

High Voltage Cables Prysmian Group

SUPERIOR MARINE CABLE SOLUTIONS

2. CONDUCTORS. 2.1 Strand Types. 2.2 Coatings Tensile Strength of Copper Wire Copper Strand Properties. 2.5 Aluminum Strand Properties

GO... with the Leader! Advanced Digital Cable is the manufacturing leader of cable for the traffic industry

A. Product Description: Stranded conductor insulated wire.

Product Index. 1 Copper Building Wire Products Flexiloy Aluminum Wire and Cable Products Power and Control Tray Cable Products 31 39

Airport Cables & Connectors

IMSA TRAFFIC SIGNAL CABLE

3M Electrical Markets Division 3M Cold Shrink Silicone Rubber Splices QS-III. Easy Installation. High reliability.

Shrink temperature of 120 C. Rated for 600V, 90 C continuous use. T&B recommended up to 1kV. HS Series Specifications

Republic Wire Inc. Our Raw Materials Make A Quality Difference. Diversity Of Products Meets Customer Needs

Heat-Shrinkable Tubing

COPALUM Terminals and Splices (For Solid & Stranded Aluminum or Copper Wire)

Underground System Design TADP 547

5-46kV 3/C TRXLPE POWER CSA Medium Voltage Commercial & Industrial Cables

High Performance Wire and Cable

SPEC 44. Wire and cable

5-35kV 1/C TRXLE MV-90 POWER (Tape Shield) Medium Voltage Commercial & Industrial Cables

Ground Clamps Cable Tray

QSLVM2500 QSLV-M Cold Shrink Insulator

BX /2 Solid Ac/BX Aluminum Cable

JCN cables. The. splice is an

American Electrical Institute

Wisconsin Contractors Institute Continuing Education

OKONITE CABLES STOCK CATALOG In Stock for Immediate Delivery

Lutze Inc. Flexible Control Cables USA Selection Guide V. 2.6

Conductors and Raceway Design

Article 250 Grounding & Bonding

Shrink temperature of 120 C. High-impact, abrasion, corrosion and chemical resistance. Rated for 600V, 90 C continuous use

CHAPTER 15 GROUNDING REQUIREMENTS FOR ELECTRICAL EQUIPMENT

Mongoose PT Platform Shale Shaker

Servo Cable Selection

Field Instrument Cable. Electrical Noise

Cable Solutions for Servo and Variable Frequency Drives (VFD)

Professional Electrician Pliers

ÖLFLEX HEAT. Cable Solutions for Extreme Temperature

WIRE & CABLE. 99 Wire Low fire hazard wire and cable

ÖLFLEX 409 P. Heavy duty control cable with PUR jacket

Copper Core & Coil Transformer

Screened servo cable with PUR outer sheath for highly dynamic power chain application - certified

Wire and Cable. 99 Wire Dual Wall 120ºC rated, Modified Polyester Low fire hazard wire and cable. Features & Benefits

TONGFENG FLEXIBLE CONDUIT TONGFENG FLEXIBLE CONDUIT

Professional Electrician Pliers

JULY Standards are finally approved by the Standards High Council of Iranian Ministry of Petroleum.

Jake Leahy s Electrical Code Connection. A look at Grounding and Bonding of Electrical Services Article Florida Building Code 5 th Edition

SPEC 55 Wire and Cable High-performance wire and cable insulation system for 65 C to 200 C

Wire Gauge Chart. Cigar Lighter 10 to 12. Dome Light 1. Radio 2 to 4. Gauges 0.7 to 1. Instrument Lights 1.5 to 3

Module 2 Unit 6, 7, 8

SECTION WIRE AND CABLES. A. The CONTRACTOR shall provide wires and cable, complete and operable, in accordance with the Contract Documents.

AEE. Canada. Australia

Armoured Instrumentation Cables to BS6883

Connection technology for wireless communication systems

EXTRA-PREMIUM GRADE PVC JACKET FOR EXTENDED CABLE LIFE. 24 AWG (0,23mm 2 ), 7/32 (7x0,20mm), Insulation Thickness: 0.010" (0,25mm)

For tough, seaworthy wire

Transcription:

Low Voltage AIRGUARD A proven, rugged product for harsh environments

Linking the future As the worldwide leader in the cable industry, Prysmian Group believes in the effective, efficient and sustainable supply of energy and information as a primary driver in the development of communities. With this in mind, we provide major global organisations in many industries with best-in-class cable solutions, based on state-of-the-art technology. Through two renowned commercial brands Prysmian and Draka based in more than 50 countries, we re constantly close to our customers, enabling them to further develop the world s energy and telecoms infrastructures, and achieve sustainable, profitable growth. In our energy business, we design, produce, distribute and install cables and systems for the transmission and distribution of power at low, medium, high and extra-high voltage. In telecoms, the Group is a leading manufacturer of all types of copper and fibre cables, systems and accessories covering voice, video and data transmission. Drawing on over 130 years experience and continuously investing in R&D, we apply excellence, understanding and integrity to everything we do, meeting and exceeding the precise needs of our customers across all continents, at the same time shaping the evolution of our industry. solutions to support the OGP industry around the world In applications ranging from drilling, extraction and storage equipment to platform and processing facilities operation, Prysmian s state-of-the-art cable systems support many major customers in the oil, gas and petrochemical industry, along with related businesses. Whether they re deployed in Brazil, the Gulf of Mexico, the North Sea or South-East Asia, our cable solutions are proving their value in harsh offshore and onshore environments; helping customers minimize environmental impact and achieve sustainable, profitable growth.

Low Voltage AIRGUARD has been designed to reduce installation costs in the field while improving the overall cable performance as compared to Type MC and MC-HL alternatives, which can often be costly, time consuming, and difficult to install. Low Voltage AIRGUARD is rated for installations in cable tray for exposed runs (Type TC-ER), conduit, and direct burial. It exceeds the stringent crush and impact resistance of UL 2225 for MC-HL cables and is permitted for use in Class I Division 1 and Zone 1 hazardous locations (TC-ER-HL) in accordance with National Electrical Code (2014) Sections 501.10(A)(2)(3) and 505.15(B)(i). Prysmian s patented AIRGUARD design affords far greater protection against water ingress and chemical attack than traditional MC Armored s. It also provides users the ease of installation of a tray cable while providing better mechanical and environmental protection than traditional metal clad cables. SPECIFICATIONS Low Voltage AIRGUARD Prysmian s Low Voltage AIRGUARD Power s are primarily designed for applications in the harsh environments found in the heavy industrial and offshore markets. Its rugged polymeric AIRBAG armor and chemical barrier protection package makes it the ideal cable choice for tough harsh environmental conditions. AIRGUARD provides the solution to the deficiencies often encountered with MC-HL cables including armor breakage encountered during installation and in applications requiring recurring bending after installation, as well as poor performance in areas of high vibration (e.g. motor connections). It also provides a safer and lower installed cost alternative to MC-HL cables due to faster, No Knife/ No Saw cable preparation and substantially reduced cost of cable glands. ASTM B3 & ASTM B8 ICEA S-82-558 (NEMA WC70) UL 44 (XHHW-2) 600V UL 1202/FT-4 UL 1277 NEC Article 336.10(7) UL 2225 NEC Article 501.10(A)(2)(3) NEC Article 505.15(B)(1)(i) Class B Soft Drawn Concentric Lay Stranded Bare Copper s Rating XHHW-2 Multiple s Direct Buried Sunlight Resistant Oil Resistant Flame Retardant TC-ER Exposed Run Rating CSA 22.2 No. 03 MSHA -40oC/ -35oC Cold Bend/ Cold Impact Mine Safety & Health Administration TC-ER- HL TC-ER- HL Class I Division 1 TC-ER-HL Class I Zone 1

Enhanced Performance with no cutting tools required & no kinks Low Voltage AIRGUARD Features No Knife? No Saw? No Problem! installation makes terminating & splicing safer for electricians, and it greatly reduces the chances of damage to the conductors. Low Voltage AIRGUARD provides users the ease of installation of a tray cable Superior crush and impact resistance as compared to MC-HL cables when tested in accordance with UL-2225 Smaller minimum bending radius as compared to metal clad cables Prysmian s patented Polymeric AIRBAG armor eliminates the concern of kinking or breaking of corrugated aluminum armor during installation or subsequent bending in service that is often associated with Type MC-HL cables Reduced installation costs due to increased flexibility, ease of pulling, faster and safer cable preparation Use of less costly cable glands with significantly reduced installation time AIRBAG layer provides superior protection from the ingress of harmful fluids, hydrocarbon and chemicals Rated for installation in cable tray, for exposed runs (Type TC-ER), conduit, duct, direct burial, and aerial applications in Class I Division 2, Zone 2, and unclassified locations Permitted for use in Class I Division 1 and Zone 1 hazardous locations (Type TC-ER-HL) in accordance with National Electrical Code (2014) Sections 501.10(A)(2)(3) & 505.15(B)(i) Rated for -40C/ -35C cold bend/ cold impact per CSA 22.2 No. 03 SPECIFICATIONS ASTM B3 & ASTM B8 UL 44 (XHHW-2) ICEA S-95-658 (NEMA WC 70) IEEE 1202 (Flame Retardant) ICEA S-73-532 (NEMA WC57) UL 1277 (TC-ER) ICEA S-82-552 (NEMA WC55) UL 2225 (TC-ER-HL) MSHA

Low Voltage AIRGUARD Advantages Reduced installation cost while improving the overall cable performance in harsh environments! Strippability No Knife!? No Saw? No Problem! The ability to strip a cable quickly without damaging the phase conductors is critical in reducing installation cost. The combination of Low Voltage AIRGUARD S unique design and strategically placed rip cords allows it to be stripped up to two or three times faster than Metal Clad cables without the worry of nicked or damaged phase conductors. Low Voltage AIRGUARD cables do not require the use of a saw (as in the case of CCW cables) which results in increased personnel safety and reduces the potential for damage to the underlying core. Outer Sheath AIRBAG Ground Wires Fillers s Extruded Filler Belt EMI Shield (VFD Constructions Only) Rip Cords VFD Chemical Resistance Heavy Industrial plants require cable that will stand up to corrosive chemicals and hydrocarbons. Whether installing in a direct burial application, in tray, or in the air, Low Voltage AIRGUARD s proprietary Polymeric Layer provides the best protection in the market for the broadest range of chemicals. Mechanical Resistance AIRGUARD is known for its Mechanical Strength. When Prysmian s R&D engineers were designing Prysmian s new Low Voltage AIRGUARD it was imperative that the traditional toughness of the prior MV designs be passed on to the Low Voltage AIRGUARD in crush tests. It is stronger than metallic armored cables. Flame Not propagating a fire is a critical design of any cable for the industrial market. Low voltage AIRGUARD passes all the industry standard flame tests, including IEEE 1202, FT-4 and IEEE 210,000 BTU flame test. VFD Low Voltage AIRGUARD VFD cables are designed with three symmetrically placed ground wires and an aluminum or copper sheath to contain the generation of high frequency electromagnetic interference (EMI) imposed on the cable when installed in a circuit containing a Variable Frequency Drive. In the event of catastrophic cable damage, this shield, plus the 3 ground wires, should contain any arcing and effectively conduct system fault current to ground. VFD designs up to 2kV are also available. Product Range Low Voltage AIRGUARD is available in 600V Power, Control & Instrumentation, from #16 AWG to 1000 kcmil. Standard stocked items include instrumentation cables, control cables to 37/C, and power cables to 3/C 750 kcmil. Accessories Glands Prysmian s Bicon offers a gland suitable for use with TC-ER- HL cables. Bicon s 424BT family of glands is putty-sealed, Explosion Proof and rated for Class I, Division 1 hazard locations. Prysmian Flexi-Peeler Stripping Tool Stripping Patterns: Circular, spiral and lengthwise OD Range: 0.18 to 1.57 Part : 4320-1030

Low Voltage AIRGUARD Product Range Power - Low Voltage 3/C & 4/C 600 Volt Product and Circuit Thickness of Grounding Ground Wires Diameter (OD) (OD ) Weight Minimum Bending Radius Ampacity (Amps) Gland, Explosion Proof, Class 1 Division 1, Barrier Type Mils # AWG Inches Inches Inches lbs/mft Inches 90 C 394075 3/C #14 AWG 30 3 18 AWG 0.071 0.135 0.620 227 2.5 25 424BT03 394040 4/C #14 AWG 30 1 14 AWG 0.71 0.135 0.660 248 2.7 20 424BT03 394076 3/C #12 AWG 30 3 16 AWG 0.089 0.153 0.660 273 2.7 30 424BT03 394042 4/C #12 AWG 30 1 12 AWG 0.089 0.153 0.705 304 2.9 24 424BT03 394077 3/C #10 AWG 30 3 14 AWG 0.113 0.177 0.715 344 2.9 40 424BT03 394044 4/C #10 AWG 30 1 10 AWG 0.113 0.177 0.765 390 3.1 32 424BT04 394078 3/C #8 AWG 45 3 14 AWG 0.142 0.238 0.860 508 3.5 55 424BT04 394079 3/C #6 AWG 45 3 12 AWG 0.176 0.274 0.980 655 4.0 75 424BT04 *394080 3/C #4 AWG 45 3 12 AWG 0.225 0.321 1.035 851 5.5 95 424BT15 *394081 3/C #2 AWG 45 3 10 AWG 0.83 0.379 1.215 1180 6.1 130 424BT15 *394082 3/C #1/0 AWG 55 3 10 AWG 0.360 0.476 1.435 1649 7.2 170 424BT06 *394083 3/C #2/0 AWG 55 3 10 AWG 0.402 0.518 1.530 1960 7.7 195 424BT06 VFD - Low Voltage 3/C & 4/C 600 Volt Product and Circuit Thickness of Grounding Ground Wires Diameter (OD) (OD ) Weight Minimum Bending Radius Ampacity (Amps) Gland, Explosion Proof, Class 1 Division 1, Barrier Type Mils # AWG Inches Inches Inches lbs/mft Inches 90 C 394039 3/C #14 AWG 30 3 18 AWG 0.071 0.135 0.630 247 7.5 15 424BT03 394041 3/C #12 AWG 30 3 16AWG 0.089 0.153 0.670 296 8.1 20 424BT03 394043 3/C #10 AWG 30 3 14 AWG 0.113 0.177 0.725 364 8.7 30 424BT03 394045 3/C #8 AWG 45 3 14 AWG 0.142 0.238 0.905 544 10.9 55 424BT04 394046 3/C #6 AWG 45 3 12 AWG 0.178 0.274 0.990 696 11.9 75 424BT04 *394047 3/C #4 AWG 45 3 12 AWG 0.225 0.321 1.095 898 13.2 95 424BT15 *394048 3/C #2 AWG 45 3 10 AWG 0.283 0.379 1.225 1236 14.7 130 424BT15 *394049 3/C #1/0 MCM 55 3 10 AWG 0.360 0.476 1.445 1719 17.3 170 424BT06 *394050 3/C #2/0 MCM 55 3 10 AWG 0.402 0.518 1.540 2017 18.5 195 424BT06 *20127515 3/C #4/0 KCM 55 3 8 AWG 0.512 0.63 1.83 3450 13 260 424BT07 *20127514 3/C #250 KCM 65 3 8 AWG 0.558 0.70 1.98 4024 14 290 424BT07 *20127942 3/C #350 KCM 65 3 7 AWG 0.661 0.80 2.22 5312 16 350 424BT08 *20127513 3/C #400 KCM 65 3 7 AWG 0.706 0.85 2.41 6008 17 380 424BT09 *20147056 3/C #500 KCM 65 3 6 AWG 0.789 0.93 2.53 7194 18 430 424BT09 *306451A 3/C #750 KCM 80 3 5 AWG 0.973 1.09 3.02 10518 22 535 -------- PRODUCT NOTES: count includes insulated grounding conductor colored green. Per 2014 NEC TABLE 310.15(B)(16) (formerly Table 310.16) Allowable Ampacities of Insulated s Rated up to and including 2000 Volts, 60 C through 90 C (140 F through 194 F), Not More Than Three Current-Carrying s *s not marked "-HL" (per UL 2225, overall cable diameter must be 1.00 inch or less to be marked "-HL")

Control - Low Voltage 600 Volt Product and Circuit Thickness Diameter (OD) (OD ) Weight Minimum Bending Radius Ampacity (Amps) Gland, Explosion Proof, Class 1 Division 1, Barrier Type Mils Inches Inches Inches lbs/mft Inches 90 C 394061 5/C #14 AWG 30 0.071 0.135 0.700 278 2.8 15 424BT03 394067 5/C #12 AWG 30 0.089 0.153 0.750 337 3.0 20 424BT03 394073 5/C #10 AWG 30 0.113 0.177 0.820 429 3.4 30 424BT04 394062 7/C #14 AWG 30 0.071 0.135 0.740 327 3.0 15 424BT03 394068 7/C #12 AWG 30 0.089 0.153 0.800 404 3.2 20 424BT04 394074 7/C #10 AWG 30 0.113 0.177 0.915 564 3.7 28 424BT04 394063 9/C #14 AWG 30 0.071 0.135 0.830 399 3.4 17.5 424BT04 394069 9/C #12 AWG 30 0.089 0.153 0.940 538 3.8 21 424BT04 394064 12/C #14 AWG 30 0.071 0.135 0.950 519 3.8 12.5 424BT04 *394070 12/C #12 AWG 30 0.089 0.153 1.030 650 5.2 15 424BT04 *394065 19/C #14 AWG 30 0.071 0.135 1.070 693 5.4 12.5 424BT15 *394071 19/C #12 AWG 30 0.089 0.153 1.165 885 5.9 15 424BT15 *394066 37/C #14 AWG 30 0.071 0.135 1.355 1137 6.8 10 424BT06 *394072 37/C #12 AWG 30 0.089 0.153 1.490 1495 7.5 12 424BT06 Instrumentation - Low Voltage 600 Volt IS/OS s Product and Circuit Thickness Diameter (OD) (OD ) Weight Minimum Bending Radius Ampacity (Amps) Gland, Explosion Proof, Class 1 Division 1, Barrier Type Mils Inches Inches Inches lbs/mft Inches 90 C 394051 1/PR #16 AWG 30 0.059 0.123 0.575 175 6.9 10.0 424BT02 394052 1/TR #16 AWG 30 0.059 0.123 0.595 197 7.2 10.0 424BT02 394053 2/PR#16 AWG 30 0.059 0.123 0.770 311 9.3 10.0 424BT04 394054 4/PR #16 AWG 30 0.059 0.123 0.850 411 10.2 10.0 424BT04 394059 4/TR #16 AWG 30 0.059 0.123 1.050 540 12.6 9.0 424BT15 394055 8/PR #16 AWG 30 0.059 0.123 1.090 664 13.1 9.0 424BT15 *394056 12/PR #16 AWG 30 0.059 0.123 1.275 901 15.3 8.1 424BT06 *394060 12/TR #16 AWG 30 0.059 0.123 1.545 1104 18.6 7.2 424BT06 *394057 24/PR #16 AWG 30 0.059 0.123 1.685 1506 20.3 6.3 424BT07 *394058 36/PR #16 AWG 30 0.059 0.123 1.970 2201 23.7 6.3 424BT07 PRODUCT NOTES: Per 2014 NEC TABLE 310.15(B)(16) (formerly Table 310.16) Allowable Ampacities of Insulated s Rated up to and including 2000 Volts, 60 C through 90 C (140 F through 194 F), Not More Than Three Current-Carrying s * s not marked -HL (per UL 2225, overall cable diameter must be 1.00 inch or less to be marked -HL )

Prysmian Group Linking the future View all of our AIRGUARD products including Medium Voltage at : na.prysmiangroup.com United States - 700 Industrial Drive Lexington, SC 29072 +1-800-845-8507 na.prysmiangroup.com/oil-gas Canada - 137 Commerce Drive R. R #3 Johnstown, Ontario K0E1T1 1-800-845-8507 (US) 1-800-263-4405 (West-CAN) 1-800-361-1418 (East-CAN)