MaxxFlow HTC. Product Information. Flow Measurement for Dry Bulk Solids

Similar documents
MaxxFlow HTC Flow measurement for dry bulk solids

MaxxFlow HTC Flow Measurement for Dry Bulk Solids

SolidFlow 2.0. Solid mass flow measurement. Product Information. SWR engineering Messtechnik GmbH enveatm a trademark of Environnement S.

Manufactured by M-Sens 2 Online-Moisture Meter for Solids. Moisture % Product Information.

ProGap Microwave barrier

Operating Instructions. MaxxFlow HTC Measurement of Bulk Solids for High Flow Rates

Technical Specification FLUXUS ADM 8127B

OPTIFLUX 5000 Technical Datasheet

Electromagnetic flowmeters and switches DWM 1000/2000

J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS. DB_Magnetic_Inductive_Flow_Sensors 05/2016

WATERFLUX 3000 Quick Start

WATERFLUX 3000 Quick Start

OPTIFLUX 5000 Technical Datasheet

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

Ambient Conditions. Operating Conditions. Pressure

TIDALFLUX 2300 F Technical Datasheet

WATERFLUX 3070 Technical Datasheet

Technical Information Nivector FTC968, FTC968Z

Technical Specification FLUXUS ADM 8x27

Rosemount TGU 65 Tank Radar Gauge, Still Pipe Antenna

Flow - Rotor. Characteristics. Applications. Mechanical-magnetical, Infrared. Quantity measurement for filling processes

OPTIMASS 1000 Technical Datasheet

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

Weighing Instruments

Level sensor Magnetostrictive, high-resolution measuring principle For sanitary applications, model FLM-H

[Pick the date] Moisture Sensor

Bulk Flow Meter LB 442 CONTACTLESS MEASUREMENT

Level Sensors Reed Contact Chain

Digital conductivity transmitter

Level Measurement Techniques In A Modern Quarry

Magnetic Inductive Flow Sensors VMI Series

KFS. Flap-type flow meter. Design and range of application

Digital flow transmitter for continuous flow measurement

Weighing Instruments. Applications. Characteristics. DMS strain gauges (load cells), DMS amplifier

UFM 800 W, C Ultrasonic flowmeter for water and wastewater

Liquid Level Switches

Drinking water monitoring

DOG-4. Oscillation Flowmeter. for gases. Measuring ranges: m 3 /h air. : PN 40; t max. p max : 120 C

prosonic T FMU230, FMU231

Digital inductive conductivity transmitter

Rotamass TI Coriolis Mass flow meter

Serie NW - Acoustic Wave. Option list. Applications / Overview

INSTRUCTION MANUAL VIBRATION SWITCH CVS 100 LC

ph or ORP Transmitter

Target disk flowmeter for liquids and gases

OPTIFLUX 1000 Technical Datasheet

MICROWAVE MOISTURE SENSOR WITH WIRELESS DATA TRANSMISSION FL-WAPP

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

6GHz Intelligent Radar Level Meter Product Manual. Model:KRD520 SERIES

DIGITAL LENGTH GAUGES

SCHMIDT Flow Sensor SS SS FB

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

Wind Transmitter First Class

Electromagnetic Flow Transmitter

Float Switches with Permanent Magnet For Vertical Installation Model RSM

Digital batch controller

OPTISONIC 7300 Technical Datasheet

SAT.. Electromotoric actuators for valves ACVATIX. with a 5.5 mm stroke and 300 N positioning force

SALES SERVICE +358 (0)

Magnetic Inductive Flow Sensors induq. Series VMI

Ultrasonic level transmitter, non-contact

Digital flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits

ChuteMaster Microwave-blocked chute detection and point level instrument

Size : Connection End : Min Temperature : Max Temperature : Materials : Cast iron body

Coriolis Massflowmeter

SN+ MID MASTER + APPLICATION WATER METERS

SITRANS F flowmeters. SITRANS F System information MAGFLO electromagnetic flowmeters 4/9

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

Flow Measurement SITRANS F M

INLINE flowmeter for continuous flow measurement

Coriolis Mass Flow Measuring System promass 40 E

Target disk flowmeters Series DP Metallic flowmeter for liquids and gases

Capacitive levels controllers

Design and applications

Insertion Flow sensor for continuous flow measurement

BATCHFLUX 5500 C Technical Datasheet

OEM radar transmitter, for aggressive media level measurement

GS.No.GBN062E-5. GENERAL SPECIFICATIONS Sensor unit

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters. 4/18 Siemens FI

6.00 INFRARED ANALYZER

INLINE flowmeter for continuous flow measurement

SONO 1500 CT Ultrasonic flow sensor

Density meter DWF. Device description. Device description DWF Page 1 of 22

T10FS. Data Sheet. Torque Flange. Special features. Installation example T10FS. B en

Magnetic-Inductive flow Meter fmi

INLINE flowmeter for continuous flow measurement

Transducer transmitter BILT 4 II 2(1) G. Technical Manual

Digital flow ELEMENT transmitter for continuous flow measurement

Positioner with HART Communication Type 3780

OPTISONIC Ultrasonic flowmeter for liquids in all industrial applications

POSIROT. PRAS3EX Magnetic Angle Sensor. Magnetic Angle Sensors (Dust-Ex-proof) Datasheet

KMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display

Size : Connection Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Refer to manual. Failure to read message could result in personal injury or serious damage to the equipment or both.

Ultrasonic level measuring device, non-contact

OPTISONIC 7300 Technical Datasheet

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver

TMU. Coriolis Mass Flow Meter. for liquids and gas

Transcription:

EN MaxxFlow HTC Product Information Flow Measurement for Dry Bulk Solids

MaxxFlow HTC MaxxFlow HTC MaxxFlow HTC Product Information Use The MaxxFlow HTC is specially developed for the flow measurement of dry bulk solids during high-volume throughput. Due to its completely open profile and its low installation height, the MaxxFlow HTC is especially suitable in situation in which it was previously only possible to use complicated or expensive mechanical solutions, e.g. impact plates or measuring chutes. The installation of the MaxxFlow HTC takes place independently of the direction of the line (vertical/inclined), but always after mechanical conveyor elements, e.g. rotary conveyors or screw conveyors. 120 t/h 80 t/h Rotary conveyor Screw conveyor Function After the conveyor, the material to be measured falls or slides through an inlet path and runs through the sensor. During the throughput, the MaxxFlow HTC records the material type and speed. Since the material falls from a constant height after emerging from the conveyor element, the speed of the product stream is accelerated, but is constant at the installation position of the sensor. Due to this constant speed, the speed measurement does not need to be activated in every case, but can be calculated as a constant depending on the height of the fall. The mass flow is determined as follows: h = constant v = 2 x g x h v = Speed g = Gravity acceleration h = Height of fall Q (kg/s) = K (kg/m 3 ) x v (m/s) x A (m 2 ) Ceramic inner pipe Through the input coupling of a high-frequency, electromagnetic alternating field, a homogenous measuring field is generated in the measuring tube. The measuring tube (interior tube of the sensor) consists of wear-resistant Al 2 O 3 ceramics. Dry bulk solids inside the measuring field reduce the amplitude of the alternating field. This leads to a measuring signal that is in proportion to the concentration of the dry bulk solids in the sensor (kg/m 3 ) If the material speed varies, for example due to a change in initial speed, then this can also be measured. This takes place through a runtime measurement with the help of two additional electrodes behind the interior ceramics tube. 2

Product Information Calibration The recording of the speed is in every case independent of the type of the dry bulk solids that are to be measured, since they can either be calculated or based on a runtime measurement. Thus the speed measurement requires no calibration. This makes a new and simple type of calibration possible: A material sample (approx. 10 Liter = sensor volume) can be poured into the sensor via a filling nozzle in the inlet path above the sensor. There is a knife-gate below the sensor that is closed for the calibration. If the sensor is completely full, then the measured density value must correspond to the bulk density of the material. This bulk density (set point) can simply be determined as a gram per liter weight and entered in the evaluation unit (full calibration). Even with large product flows, the measurement is completely calibrated with a material sample of only about 10 liter. Material drop-tests using calibration points during a running process are thus a thing of the past. The handling of several tons of material as a reference therefore is no longer necessary. System A complete measuring station consists of these components: + Sensor Measuring feeder for installation in the conveyor line Evaluation unit MFE 100 Evaluation unit The measuring feeder is available in sizes DN 150 mm and DN 200 mm. On request the components inlet path (between conveyor element and sensor) and gate valve (for calibration) can also be configured and supplied. The evaluation unit are connected to the sensor using 5-wired, shielded cable. The maximum distance between measuring feeder and evaluation unit is 300 m. DN 150mm DN 200mm 3

Product Information Configuration For the configuration of the sensors, the knowledge of the maximum volume flow is fundamentally important in order to configure the measuring point in such a way that the dry bulk solids can flow through the sensor unhindered and the product flow is not influenced. The diagrams in figure 1 and 2 show the maximum conveyable volume depending on material speed for the two sensor sizes DN 150 mm and DN 200 mm. The sensor cross-section in both cases is filled to 50 %. Example: If the max. mass flow amounts to 80 t/h, and if the material has a bulk density of 0.8 t/m 3, then the maximum volume flow amounts to 100 m 3 /h. When using a MaxxFlow HTC DN 150 mm, a speed of approx. 3 m/s would be necessary. When using a MaxxFlow HTC DN 200 mm, a speed of approx. 1.7 m/s will be required. Figure 3 shows that for these speeds to be reached, an inlet path of 0.5 respectively 0.15 m will be necessary between the conveyor and the sensor. m³/h m³/h MaxxFlow DN 150 throughput at max. 50 % fill level 300.0 250.0 200.0 150.0 100.0 50.0 0.0 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 m/s Speed of fall Figure 1 MaxxFlow DN 200 throughput at max. 50 % fill level 300.0 250.0 200.0 150.0 100.0 Turndown and measuring range Which sensor type is being used depends on the available standing installation height and the turndown or the desired measuring range. The sensor itself has an installation height of 290 mm (DN 150 mm) or 310 mm (DN 200 mm). To equip the measuring point from the above example with a DN 150 mm sensor, an installation height of 500 mm + 290 mm = 790 mm would be necessary. The turndown, i.e. the ratio between the end and the beginning of the measuring range, amounts to 1:5 for all MaxxFlow HTC sensors. With regard to the example provided, it is possible to measure with a MaxxFlow HTC DN 150 mm between 20 m 3 /h and 100 m 3 /h. m 50.0 0.0 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 m/s Speed of fall Figure 2 m Inlet path 1.2 1.0 0.8 0.6 0.4 0.2 0 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 m/s Speed of fall Figure 3 4

268,7 294 Product Information A MaxxFlow HTC DN 200 mm can also be used for this measuring task. Care must be taken that the angle for the contractions of the inlet path at a height of 0.15 m does not become too flat. The angle α (see figure 4) must be at least 60 in order to guarantee a flawless product flow. If the inlet path (height of fall) must be enlarged to maintain the demand after an angle > 60, then it must be noted that the lower limit of the measuring range moves upward. If for example an inlet path of 0.3 m would become necessary, then the speed would be approx. 2.5 m/s and thus the maximum volume for a MaxxFlow HTC DN 200 mm 150 m 3 /h. With a turndown of 1:5, the lower measuring range limit would then be 30 m 3 /h. Figure 4 α 60 α Inlet path Advantages installation free of obstacles in the cross-section, therefore no dead spots independent of the arragement of the line (vertical or inclined) simple refitting dust proof zero-contact measuring procedure (no mechanics) maximum material temperature 120 C pressure-resistant up to 10 bar on request abrasion-resistant ceramic inner pipe Dimensions 36 23,5 8 x Ø 22 Ø 150 8 x Ø 22 Ø 340 10 M8 Ø 240 Ø 285 Ø 295 Ø 200 290 Flange EN 1092-1 01 A / DN 150 / PN 10 / 150 310 Flange EN 1092-1 01 A / DN 200 / PN 10 / 200 5

Product Information Technische Daten Sensor Housing Steel St52, powder-coated (optional stainless steel 1.4541) NW 150/200 mm, Flange according EN 1092-1 Evaluation unit Power supply 110 / 240 V AC, 50 Hz, optional 24 V DC Power consumption 20 W / 24 VA Protection category IP 65 to EN 60 529/10.91 Inner pipe Ceramic Al 2 O 3 Protection category Operating temperature Max. working pressure Working frequency Transmitting power Weight Dimensions Accuracy IP 65; ATEX: Cat. 3 D Sensor pipe: -20 +120 C Sensor electronic: 0 + 60 C 1 bar, optional 10 bar 88 khz Max. 2 mw Depending to model NW 150: B = 420 mm, H = 290 mm NW 200: B = 480 mm, H = 310 mm ± 2 5 % (in calibrated measuring range) Operating temperature -10 +45 C [14 113 F] Dimensions 225 x 237 x 174 (W x H x D) Weight Approx. 2.5 kg Cable glands 3 x M16 (4.5-10 mm Ø) Terminal clamp wire size 0.2-2.5 mm 2 [AWG 24-14] Current output signal Alarm output Error output Data backup Impulse output 2 x 4 20 ma (0 20 ma), load < 700 Ω Relay with toggle switch - max. 250 V AC, 1 A Flash memory Open collector - max. 30 V, 20 ma RS 485 interface ModBus SWR engineering Messtechnik GmbH Gutedelstraße 31 79418 Schliengen (Germany) Fon +49 7635 82 72 48-0 Fax +49 7635 82 72 48-48 www.swr-engineering.com (All rights reserved.) 6 EN 25/11/11