FIXTURE INTEGRATED DAYLIGHT DIMMING PHOTOSENSOR

Similar documents
Installing the FSP-211 Sensor in Light Fixture

SELECTABLE MODE HIGH/LOW/OFF PIR FIXTURE INTEGRATED INDOOR/OUTDOOR MOTION/PHOTO SENSOR

HIGH/LOW/OFF PIR OUTDOOR PHOTO/MOTION SENSOR IN IP66 ENCLOSURE FOR FLEXIBLE MOUNTING

HIGH/LOW/OFF PIR OUTDOOR PHOTO/MOTION SENSOR IN IP66 ENCLOSURE WITH BLUETOOTH

High/Low Bay Passive Infrared Occupancy Sensor

LOAD AWG Solid CU Wire Only LINE NEUT FSP-211. High/Low PIR Occupancy Sensor 230 VAC, 50 Hz 1200W max ballast 5E4

DESCRIPTION & OPERATION: PIR OCCUPANCY SENSOR MSWSFSP221B-D FEATURES:

O ccupancy and Light Level Sensor L ow Vo l tage Ceiling Fixture Mount

White Paper - Photosensors

This document is intended for Lighting Control Systems professionals

with Light Level, Isolated Relay and Manual On features

Single-zone Daylighting Control Sequences of Operation. Topic: DLM Operation with LMLS-400 Photosensor, v2.xx Issue: # TB185 Date: March 10, 2012

Lumen Output (3500K) Lumen Efficiency (3500K)

EasyAir office sensor standalone SNS100

GR i. design guide. Control Panel. MicroPanel-iDH and -idim. Switches. Photosensor. The MicroPanel-iDH or -idim. Accessories

EasyAir Office sensor advanced grouping SNS200

EasyAir Office sensor advanced grouping SNS200

TekLink TL100 with Passive Infrared Sensing System Overview

RSS Rectilinear Suspended Series

v3 360 Passive Infrared Line Voltage Occupancy Sensor

Sensors. Datasheet. EasyAir SNS200

Sensors. Datasheet. EasyAir SNS200

Installation Instructions

LCC1653, LCC1656, LRI1653 Datasheet ActiLume DALI System

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

CX-100. Installation Instructions. PIR Occupancy Sensor SPECIFICATIONS

FC-SENSOR, FC-VSENSOR, FCJ-010, FCJ-ECO

Sensors. EasySense. Fixture-Mount (with Ceiling-Mount Option)

FSP-211 DIGITAL HIGH/LOW PIR FIXTURE INTEGRATED SENSOR

CONTENTS OF THE BOX. *PIR sensor only **Dual Technology and PIR sensors only. Description PIR Ultrasonic Dual Technology

2 Pendant Adjustment. Pendant Slider Plate. 3/4 (19mm) IP, (29mm) O.D. Knockouts. 1/2 (13mm) IP, (22mm) O.D. Knockout

ViveT PowPak Fixture Controls

Energy Saving Module (HG-ESM-01)

Sensors. EasySense. Fixture-Mount for Basic Grouping

Sensors. EasySense. Fixture-Mount for Basic Grouping

Dialight Daylight Harvesting Sensor User Guide

Sensors. EasySense. Fixture-Mount for Advanced Grouping

Sensors. EasySense. Fixture-Mount Advanced Grouping for Evokit

Indoor Contact Input Photosensor

Sensors. EasySense. Fixture-Mount for Advanced Grouping

CXB Series SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Luminaire TO INSTALL: INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION

Sensors. EasySense. Fixture-Mount for EvoKit

SeriesTWO RGB Fluorescent Fixtures. Installation and Instruction Manual

High Bay Occupancy Sensor for Use with Electronic Ballast HID Luminaires

Human Centric Lighting System

Fixture Built-in Sensor Daylight Harvest Version

Operating mode. distance. 7 m Light ON Dark ON (selectable) 2 m [100 mm] (See note 1.) 100 mm (wide view)

Installation Instructions

Dual Technology Wall Mount Occupancy Sensor

Installation Instructions

Cost Effective Simplified Controls for Daylight Harvesting

Installation Instructions

diode led 24VDC COMMERCIAL GRADE SPECIFICATION SHEET RECEIVE A UL LISTED DRIVER WHEN ORDERING THE LO-PRO JUNCTION BOX & DRIVER COMBO ON PAGE 2.

LUMINAIRE ID SIZE CENTER OPTICS SIDE OPTICS LIGHT SOURCE NUMBER OF LAMPS VOLTAGE BALLAST ELECTRICAL MOUNTING FINISH CONTROLS OPTIONS

LED Wattage. Color Temp. 350 ma 35LA 55LA 70LA 90LA ma 50LA 80LA 105LA ma 140LA ma 75LA 105LA LA

Overview of Smart Building Automation, Photosensor and Occupancy Sensor Technology

ActiLume 1-10V. OEM application guide

Footcandles. Light. Maintain. Level. Min. Light Level

EBDHS-MB-AT-DD. RF ceiling PIR presence detector DALI / DSI dimming. Product Guide. Overview. Features

E3S-CR62/67. Ideal for detecting transparent glass and plastic containers. Transparent bottle sensor. Features

FUNTRONIX SCORE-N-TIME TM GAMEROOM EDITION ELECTRONIC SCOREBOARD WITH REAL ALARM CLOCK & DATE. OPERATING MANUAL Model SNT-125G

Infrared Wall Mount Occupancy Sensor

Dual Technology Wall Mount Occupancy Sensor

ZoneLite setup remote handset. Daylight Linking & Daylight Dependency control

Emergency PHM Series. Emergency PowerHUBB Node - Master/Control/Tunable White. Dimensional Data. Ordering Information (Example: PHM4PC EM)

Table of Contents. Proximity Sensors. IEC Limit Switches. Encoders. Current Sensors. Section 17

Application Notes Photoconductive Cells

Distance-setting Photoelectric Sensor

IRIS \ IRIS-I QUICK SET-UP GUIDE STEP 1 INSTALL

GE Sensing. Introduction. Wiring Diagrams (Typical) Field Calibration. Installing the Sensor

Philips Ledalite Phone: Fax: Web: Programming Guide Version 2.0

VEER takes a detour from the ordinary, infusing texture and form into a sleek new direct/ indirect luminaire.

Applications. HBT02 Transceiver Node. Features. Note: This datasheet is intended for information related to the hardware only.

ASSEMBLY AND INSTALLATION INSTRUCTIONS

Taxonomies, Classifications, and Categories Residential dimmers, motion sensors, controls, & photo cells Wireless occupancy/vacancy sensor

LIGHTING Common terminology 2. Sources and luminaires 3. Controls

LRF20CR2BPWH Ceiling MNT Wireless Occ Sensor

Product Specifications

Distance-setting Photoelectric Sensor

Data sheet. Function description. Benefits

CONTINUOUS DIMMING MOTION SENSOR & COMPATIBLE REMOTE PROGRAMMER MSITXLRD509 & RMTITXSRP280

E3Z-LS. Distance-settable Photoelectric Sensor. Ordering Information. Sensors. Accessories (Order Separately)

Efficiency higher than 85% Power Factor >92% Case TC* Protection Storage Humidity

WATTSTOPPER OEM SENSOR GUIDE INTEGRATED LIGHTING CONTROLS. designed to be better.

L.T.F All-In-One Dimmable LED UNIdriver - CLASS 2

Z4D-F. LED-type Micro Displacement Sensor with Many Features in a Compact Body. Micro Displacement Sensor. Ordering Information.

Daylight Control Package

Catalog Number LSBT. Example: LSBT6C8T5WD1-BZ QMB. Optics. Type II Type III Type IV Type IV Automotive Type V Medium Type V Wide T2 T3 T4 T4A T5M T5W

OCC Motion Sensor. Guide: how to program and use

Radiometric and Photometric Measurements with TAOS PhotoSensors

QUANTUM PHOTO-METER LX OPERATING INSTRUCTIONS. ... Three decimal points only displayed Overrange reading. Adjust Range. ( X 1000will light up)

ABB i-bus EIB Light controller LR/S and light sensor LF/U 1.1

EBDSPIR-AT-DD. RF ceiling PIR presence detector DALI / DSI dimming. Product Guide. Overview. Features

Catalog # Project. Comments. Prepared by. Warranty Five year warranty. 51mm mm 27 = 2700K 30 = 3000K 35 = 3500K 40 = 4000K

PRELIMINARY. S050W-054C1400-L03-UN-D2 50W Programmable Driver. Electrical Specifications. Protections. Environmental Specifications.

E3S-CL. Distance setting photoelectric sensor in metal housing. Features

TECHNOLOGY INFORMATION SHEET

LL-105-R LED Dimmer & 0-10V Bridge Setup Guide

Satellite LED Plus Pro Instructions

Catalog # Project. Comments. Prepared by. Warranty Five year warranty mm mm 6 152mm -27 = 2700K -30 = 3000K -35 = 3500K -40 = 4000K

Transcription:

FIXTURE INTEGRATED DAYLIGHT DIMMING PHOTOSENSOR Product Overview The is a fixture-integrated dimming photosensor. It provides a continuous dimming signal to a 0-10 VDC dimming ballast, based on daylight levels. The is a closed loop system; it considers both daylight and electric light when determining dimming levels. It uses a sliding control algorithm to maintain the desired illuminance levels for separate night and day target s. The slowly Nighttime Auto button for automatic dimming Daytime Night Auto Day LED indicates button activation di Raise/lower light levels raises or lowers the electric lights to avoid sudden changes that can annoy occupants. After the photosensorequipped fixture is installed, final setup adjustments are made using the remote control setup tool. After commissioning, the automatically adjusts the electric lights to meet target illuminance levels. The is a low voltage device used in conjunction with a Wattstopper FS-PP power pack. Diffuser Photosensor Beauty ring 0-10V dimming cables, 12 AWG, 105 C, 600V Models Specifications and Features Operating voltage: 24 VDC Power consumption: 9mA @ 24VDC Max sink current: 50 ma Dimensions: 1.57 x 0.98 x 0.84 (40mm x 25mm x 21.4mm) LxWxD Weight: 64.4 grams (2.27 ounces) Operating temperature: 32 to 104 F (0 to 40 C) Operating humidity: 5-95%, non-condensing Full range dimming: 0.2 VDC (min.) to 10 VDC (100% lighting) output voltage Includes 6 (1.83m) lead with connector and 1 (0.3m) bare leads for 0-10 VDC signal RJ-45 wire length: 6 (1.83m) Maximum ballast control: 50 Sliding control algorithm Photopic curve accurately measures light as perceived by human eye Precise control of lighting to maintain desired light level Optional occupant remote for increased user satisfaction and maximum energy saving UL and cul listed Indoor use only Five year warranty Materials ABS, flame retardant Meets materials restrictions of RoHS Factory Defaults Requires configuration using LSR-301S LED indicates button activation Auto button for automatic dimming Photosensor Setup Remote Connecting cable 24 AWG, 80 C, 300V LSR-301-P er Auto Raise/lower light levels connector LSR-301-P Personal Remote 1

Detection Features Window Light Fixture 70º Field of view Spatial Response The spatial response describes the sensitivity of the photosensor to incident radiation from different directions. By having a 70 degree field of view, the optical signal sensed by the is very representative of the overall work plane illuminance, and it is less affected by normal activity in the room, such as occupant interference or temporary changes to room reflectances. Typical Daylit Zone, about 12' (3.6m) Normalized Response % 100 80 60 40 20 0 Test device V(λ) 400 600 800 1000 Wavelength (nm) Spectral Response The features an advanced photocell component. For the first time in a photosensor, the photocell s response matches the human perception of light. It measures energy only in the visual range, instead of measuring energy over a wider range than the visual spectrum as do most photocells. Most photocells measure infrared and ultraviolet energy as well, and over-report daylight because it contains large amounts of these types of energy. In research conducted by the Lighting Research Center (LRC), it was estimated that over-reporting daylight illumination could result in controlled light levels being 40% lower than desired. By eliminating this source of error, the greatly improves performance. 100% led Lights Night Algorithm The uses a sliding control algorithm. This means it has separate night and day s. Each represents the desired photocell signal under that condition. To determine the correct dimming level for any given photocell reading, it calculates the level based on the slope of the line between the two s. The result is accurate dimming that maintains the task illumination. 0 0 Measured Lights Day 100% Sliding does require adjustment twice, once with no daylight present, usually at night, and once with daylight present. However, the greatly simplifies the adjustment procedure with individual adjustment buttons on the commissioning/set-up remote. 2

Photosensor Placement and Commissioning The photosensor-equipped fixtures are commissioned under two conditions, Night and Day. Either adjustment may be completed first. The red LED under the photosensor s lens flashes continuously until the Night and Day adjustments are both completed. Then, it can begin automatic dimming. Conditions for Setup Set up photosensor-equipped fixtures after all furnishings are installed. Placement of furnishings affects the way light reflects from various surfaces. Furniture, floor and wall coverings must be installed and clean. All light fixtures must be installed and fully operational. Window coverings must be installed, clean and operable. Remove unnecessary objects such as tools and installation materials from the photosensor s view. Do not block primary sources of electric light or daylight from reaching the photosensor s view. Window blinds: If installed in the area, adjust them to maximize daylight while not allowing direct beam sunlight to enter the controlled area. At night, adjust them so they block lighting from outdoor fixtures. Lights from other areas: If non-dimmed lights in adjoining areas contribute to the light viewed by the photosensor, these lights must be on during both Day and Night adjustments. Target Illuminance Levels Determine the illuminance required in the controlled space. In some applications, a footcandle target may be specified for the controlled space. If this is the case, use a light meter to take measurements before and during the commissioning process. Choose a reference location in the controlled area that is most likely to have the lowest illuminance level during daylight conditions and is located farthest from the window or skylight. If the illuminance level is too low, select another location, or measure the illuminance level on a brighter day. If no target illuminance is specified, adjustments can be based on user perception or preferences. Adjustment Procedure Initial adjustments to the photosensor are done using the 5-button remote control. The LED on the should light every time you press a button on the remote. The remote s green LED also flickers for the duration of the press. (up arrow) Press to increase light output. (down arrow) Press to decrease light output. Night Press to begin and end the Night adjustment process. Auto Press to begin automatic dimming. Day Press to begin and end the Day adjustment process. Day Adjustment Make this adjustment when daylight is providing illumination that is typical of the daytime conditions at the reference location in the controlled area. Nighttime Auto button for automatic dimming Daytime 1. Press the Day button once. The s green LED flickers. 2. Press or to adjust electric lights to the appropriate light level. 3. If an illuminance target is specified by the lighting designer, use a light meter at the workplane to verify the footcandle value. 4. Once the appropriate illuminance level is reached, press and HOLD the Day button for 3 seconds. The acknowledges setting of the Day target by lighting the green LED twice for 3 seconds each time. Night Adjustment Make this adjustment when there is no daylight illumination at the reference location. To complete the night commissioning during the day, the night environment must be simulated by blocking all sources of daylight. 1. Press the Night button once. The s s green LED flickers. 2. Press or to adjust light level. If an illuminance target is specified by the lighting designer, use a light meter at the workplane to verify the footcandle value. 3. Once the target level has been reached, press and HOLD the Night button for 3 seconds. The acknowledges setting of the Night target by lighting the green LED twice for 3 seconds each time. Begin Automatic Dimming Night Auto Using the LSR-301-P, the user can raise the target illuminance level by up to 25% of the target illuminance level set with the during commissioning, or reduce target illuminance to the minimum level for the connected lamp/ballast. Pressing the (up arrow) or (down arrow) temporarily raises or lowers the target illuminance level. The controls the lights to maintain the new target level until another button is pressed. Pressing Auto cancels the user adjusted target illuminance level. The returns to automatic dimming using the levels set with the. Day Photosensor Setup Remote LED indicates button activation Raise/lower light levels 3

Dimensions.90 (22.87mm) 1.57 (39.88mm).72 (18.29mm) 1.0 (25.4mm).98 (24.89mm).57 (14.48mm) Installing the Sensor and FS-PP Power Pack in Light Fixture Mount the so the fixture s lamp output (candlepower distribution) is outside the sensor s peak sensitivity area. 1. Install the FS-PP as directed in the installation instructions provided with the power pack. 2. Determine an appropriate mounting location for the inside the light fixture. Cut a 3/4 diameter hole through the sheet metal in the bottom of the fixture. 3. A beauty ring and thumbscrew collar are supplied to secure the lens through the fixture wall. Depending on the wall thickness and curvature, the installer may need to use the thumbscrew collar on the inside or outside of the fixture, or not at all. Remove the beauty ring and thumbscrew collar from the lens pipe. 4. Insert the lens from the inside of the fixture, through the hole in the bottom of the fixture. If the lens extends too far outside the fixture, use the thumbscrew collar to adjust the depth. Tighten it to the outside of the fixture or tighten it against the sensor body before inserting the lens through the fixture wall. Then, put the beauty ring onto the lens pipe and tighten it securely. Tighten Fixture wall FS-PP Fixture wall Beauty ring only Thumbscrew collar + beauty ring Thumbscrew collar + beauty ring 4

Wiring Diagrams COM N/O N/C ISOLATED RELAY OUTPUTS TO LOAD TO SENSOR 03500r1 Model: Fixture Sensor Power Pack FS-PP V2 120/277/347VAC, 60Hz @120VAC 5A (N/O) 3A (N/C) @277VAC 4.3A (N/O) 2.5A (N/C) LISTED @347VAC 3.4A (N/O) 88T9 Santa Clara, CA 800.879.8585 2A (N/C) Appliance 03392r2 Strip Gauge 12-18AWG CU wire only AC INPUT GROUND NEUTRAL LINE Ground Line 120/277/347 Volts AC Inputs to Dimming Violet Grey To connect with FS-PP power pack, plug in from into TO SENSOR receptacle on FS-PP. Connect violet and grey wires from to 0-10V inputs on dimming ballast or driver. Line (120/277/347VAC) Ground COM N/O N/C ISOLATED RELAY OUTPUTS TO LOAD TO SENSOR 03500r1 Model: Fixture Sensor Power Pack FS-PP V2 120/277/347VAC, 60Hz @120VAC 5A (N/O) 3A (N/C) @277VAC 4.3A (N/O) 2.5A (N/C) LISTED @347VAC 3.4A (N/O) 88T9 Santa Clara, CA 800.879.8585 2A (N/C) Appliance 03392r2 Strip Gauge 12-18AWG CU wire only AC INPUT GROUND NEUTRAL LINE Line FS Occupancy Sensor Switched Dimming Violet FS-C3 (3') or FS-C1 (10') FS-C4 6 cables Grey To add occupancy-based, automated on/off control, combine the sensor with an FS occupancy sensor. Connect wiring as shown. 5

Wiring Diagrams Line (120/277/347VAC) Manual OFF Switch Ground COM N/O N/C ISOLATED RELAY OUTPUTS TO LOAD TO SENSOR 03500r1 Model: Fixture Sensor Power Pack FS-PP V2 120/277/347VAC, 60Hz @120VAC 5A (N/O) 3A (N/C) @277VAC 4.3A (N/O) 2.5A (N/C) LISTED @347VAC 3.4A (N/O) 88T9 Santa Clara, CA 800.879.8585 2A (N/C) Appliance 03392r2 Strip Gauge 12-18AWG CU wire only AC INPUT GROUND NEUTRAL LINE Line To add manual off control using a local switch, connect wiring as shown. Switched Dimming Violet Grey 6 cables Sequence of Operation The is designed to mount to a light fixture and dim a single zone of lights. To immediately begin automatic dimming after the Night and Day adjustments are BOTH completed, press the Auto button. Otherwise, ten minutes after the last adjustment keypress, the following will occur: If only the Night has been adjusted, the signal to the ballast will remain at the level to which it was adjusted. The red LED will continue to flash. If only the Day has been adjusted, the signal to the ballast will go to full output (10VDC). The red LED will continue to flash. If both Night and Day s have been established, the will begin automatic dimming. The red LED will flash until both the Day and Night s are properly adjusted. The Night must always require more electric light output than the Day. If it does not, the red LED on the will flash to indicate an invalid. Ordering Information Catalog # Master Pack Details Inner Pack Details Master Case dimensions (inches) Inner Case dimensions (inches) Pack Weight Pack Quantity Length Width Height (pounds) Quantity Length Width Height 200 16.35 12.75 20.27 38.4 50 19.75 7.88 8.25 9.12 250 N/A N/A N/A N/A N/A N/A N/A N/A N/A LSR-301-P 250 N/A N/A N/A N/A N/A N/A N/A N/A N/A FS-PPv2 100 21.14 19.72 10.31 21.8 N/A N/A N/A N/A N/A Catalog # Color Description Input Voltage White Fixture Integrated Daylight Dimming Photosensor 24 VDC White Setup Remote (required) Two AAA batteries (included) LSR-301-P White Occupant Remote Two AAA batteries (included) FS-PP v2 White Fixture Sensor Power Pack 120/277/347 VAC; 60Hz Information supplied above is subject to change. Harmonization code: 8542310000. Country of origin: China. Weight (pounds) Pub. No. OEM-208 09/2016 6