SELCO T-Line Generator Control, Protection and Monitoring

Similar documents
SIGMA S6100 S/LS Module

T4500 AUTO SYNCHRONIZER T4800 LOAD SHARER T4900 VAR LOAD SHARER

Numbering System for Protective Devices, Control and Indication Devices for Power Systems

Automatic synchronising relay

Installation and start up instructions. Synchroniser type FAS-115DG uni-line H (UK) Synchronisation of generator to busbar

GX 340 SERIES (AUTOMATIC VOLTAGE REGULATOR)

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

V AC Meas. current (In): A. Frequency range: Hz. Measuring system:

Installation and start up instructions. Paralleling relay type HAS-111DG uni-line G (UK) Synchronisation of generator to busbar

Installation and start up instructions. Synchroniser type FAS-113DG uni-line F (UK) Synchronisation of generator to busbar

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

DEIF A/S. Description of options. Option H3 Serial communication Profibus DP Multi-line 2 version 2. Description of option. Functional description

DATA SHEET. Paralleling relays, HAS-111DG ANSI code 25

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

Excitation Systems THYRIPART. Compound-Excitation System for Synchronous Generators. Power Generation

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

SPECIFICATION, CONTROLS AND ACCESSORIES

DEIF A/S. Description of options. Option H1 Serial communication CAN open. Description of options. Functional description. Tables.

Excitation Systems RG3 - T4. Transistorized Excitation Systems for Synchronous Generators. Power Generation

NORTH CAROLINA INTERCONNECTION REQUEST. Utility: Designated Contact Person: Address: Telephone Number: Address:

Overview. HighPROTEC Line. POWER DISTRIBUTION Controlling the Power of Energy PROTECTION AND CONTROL RELAYS FOR YOUR POWER SYSTEMS

P. O. BOX 269 HIGHLAND, ILLINOIS, U.S.A PHONE FAX

Time over/underfrequency relay with protection assemblies

DATA SHEET Reverse power relays, RMP-121D ANSI code 32

Fixed Series Compensation

D I G I T A L V O L T A G E R E G U L A T O R

S11 Adjustable Speed Drive Engineering Specification

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

VF-nC1 Adjustable Speed Drive Engineering Specification

Excitation Systems. Service Generators SIPOL. Transistorized Excitation Systems for Synchronous Generators. Power Generation

Installation and start up instructions. Detection of vector shift. Detection of over- and underfrequency. Generator disconnection on mains failure

SPECIFICATION, CONTROLS AND ACCESSORIES

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2

Design a Power System Simulator Model and Implement the Generator and Motor Controlling

Utility Interconnection and System Protection

Multimeter 500CVD21 RTU500 series

HEP300 ELECTRONIC POTENTIOMETER USER MANUAL

BE1-32R, BE1-32 O/U DIRECTIONAL POWER RELAY

PARAMETER LIST PARAMETER LIST

815-BR SERVO AMPLIFIER FOR BRUSH SERVOMOTORS

Training Fees 4,000 US$ per participant for Public Training includes Materials/Handouts, tea/coffee breaks, refreshments & Buffet Lunch.

E3 Adjustable Speed Drive Engineering Specification

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

200ADM-P. Current Injection System with Phase Shift A 3.000s 2.000A 50.00Hz 0.0. Features

System Protection and Control Subcommittee

FUJI Inverter. Standard Specifications

Option H2, Modbus communication Automatic Gen-set Controller H SW version 2.33.X

Catalogue 1SFC en, Edition 3 November 2003 Supersedes Catalogue 1SFC en, Edition 2 November Arc Guard System TVOC

IDAHO PURPA GENERATOR INTERCONNECTION REQUEST (Application Form)

Issued: September 2, 2014 Effective: October 3, 2014 WN U-60 Attachment C to Schedule 152, Page 1 PUGET SOUND ENERGY

ENGINEERING DATA SUBMITTAL For the Interconnection of Generation System

GENERATOR INTERCONNECTION APPLICATION Category 5 For All Projects with Aggregate Generator Output of More Than 2 MW

6.9 Jump frequency - Avoiding frequency resonance

Product Data Sheet 8452/2HHP. The engineer's choice

Specifications of ASDA A2-E_220V Series

Drives 101 Lesson 3. Parts of a Variable Frequency Drive (VFD)

State of North Dakota Engineering data submittal Page 1 For interconnection of distributed generation to Otter Tail Power Company

DEIF A/S. Description of options. Option H1, CAN open communication Basic Gen-set Controller. Description of option. Functional description

Power systems Protection course

Rexroth Frequency Converter Fe 0.75 kw to 7.5 kw / 400 VAC

AI-517-B1. Analog Input Module (open < 3.8 ma)

Advanced Test Equipment Rentals ATEC (2832)

Instructions AVC125-10: Voltage Regulator. Voltage Range. Maximum Continuous Burden. Voltage Range. Nominal Frequency

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Aggregated Generating Facilities Technical Requirements

GTT 25A - 40A - 60A - 90A - 120A POWER SOLID STATE RELAYS WITH ANALOG CONTROL

Power System Protection Where Are We Today?

EH2741 Communication and Control in Electric Power Systems Lecture 2

Operating Instructions

ADJUSTABLE SPEED DRIVES. W7 Series. 18 Pulse

Two-phase Digital Stepper Motor Driver SD Low Vibration Low Noise Low Power. Characteristics. Performance Index. Product Codes:

Synchronisation meters for manual or semiautomatic synchronisation Synchronization Meters SQ0114/SQ0104 Synchronization Meters SQ0214/SQ0204

Orbital GFI Inverter Series

These drawings and single line diagrams provide an outlook of Basler Electric solutions for Excitation System installations and retrofit

Variable Frequency Drive / Inverter (0.4 ~ 280kW)

Option D1 Voltage/var/cos phi control Description of option Functional description

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

APPLICATION: The heart of the system is a DSR 100 Digital Static Regulator used in conjunction with standard SCR based rectifier bridges.

PROTECTION of electricity distribution networks

IRT AT-Small. Technical Manual. quality IN MOTION. quality IN MOTION

SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS

For additional PowerFlex 4 and 40 data and general drive information, refer to the following publications:

OPERATING, METERING AND EQUIPMENT PROTECTION REQUIREMENTS FOR PARALLEL OPERATION OF LARGE-SIZE GENERATING FACILITIES GREATER THAN 25,000 KILOWATTS

METRAClip87 and 88 Clamp Multimeters

APPENDIX B: Generation Interconnection Application Form

PID500 FULL FEATURED PID TEMPERATURE CONTROLLERS

General Purpose Drives

AS440 AUTOMATIC VOLTAGE REGULATOR (AVR)

PRC Generator Relay Loadability. Guidelines and Technical Basis Draft 4: (June 10, 2013) Page 1 of 75

Initial Application Form for Connection of Distributed Generation (>10kW)

Phase and neutral overcurrent protection

POWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS.

Smart Power Relay E I...

The new Yaskawa Varispeed G7 Inverter

Generator Advanced Concepts

OPERATING, METERING, AND EQUIPMENT PROTECTION REQUIREMENTS FOR PARALLEL OPERATION OF LARGE-SIZE GENERATING FACILITIES GREATER THAN 2,000 KILOWATTS

High Performance Process & Temperature Controllers

DynaDrive INFORMATION MANUAL SDFP(S)

Protective Relays Digitrip 3000

ADJUSTABLE SPEED DRIVES VF-S11 Sords Electric

PRC Generator Relay Loadability. Guidelines and Technical Basis Draft 5: (August 2, 2013) Page 1 of 76

Transcription:

SELCO T-Line Generator Control, Protection and Monitoring SYNCHROSCOPE TOO SLOW SYNC TOO FAST BUS GEN www.selco.com

Selco T-Line The Selco T-line offers a complete range of system components for generator control, protection and power monitoring. The units are for DIN rail mounting or screw mounting in switchboards. Since the units are working on identical principles and have similar design and adjustment schemes, they are easily installed or replaced. All units are available in a number of versions varying in supply voltage and other functions, hence meeting specific customer requirements to a large extend. Synchronizing and load/power control The SELCO T-Line range includes various Auto Synchronizers and Load Sharers for load/power control. The Auto Synchronizers perform automatic synchronization of incoming generators in a minimum of time. The Load Sharers provide automatic load sharing and system frequency control for generators running in parallel. Two solutions are available: One for synchronizing and load sharing on generators with conventional governors (and electronic speed controllers via an intermediate motorized potentiometer). The other for connection directly to all types of electronic speed controllers. For synchronizing SELCO also supplies Synchroscopes for illuminated indication of the phase difference. Also available is a VAr Load Sharer for automatic load sharing of the reactive power or for power factor control on generators running in parallel with the grid (utility). Cogeneration Application T4500 Grid M8100 T4500 B9300 T4500 Busbar T4800 T4800 G G Synchronizing Parallel Running Generators to the Grid or a Shaft Generator

T4000 Auto Synchronizer T4500 Auto Synchronizer T4900 VAr Load Sharer The T4000 performs automatic synchronizing of an incoming generator with electronic speed controllers in a minimum of time, by controlling the generator speed and the phase between the generator and the busbar. The unit has fixed and variable output for adaptation to a wide range of electronic speed controllers. T4400 Load Sharer The T4500 performs automatic synchronization of an incoming generator in a minimum of time by controlling the frequency via the electric servomotor on a speed governor or via the E7800 Motorized Potentiometer, or T7900 Electronic Potentiometer. Among the features it can control the T4800 Load Sharer to e.g. transfer a load from one or several diesel generators operating in parallel with the grid, or on board a ship, to a shaft generator. The frequency will be aligned by the synchronizer through the load sharers. The unit has voltage matching output with adjustable voltage window. The T4900 provides automatic reactive load sharing (VAr) and system voltage control for parallel running generators. The reactive load and voltage are measured on each generator, compared with the other generators and corrected via the E7800 Motorized Potentiometer or T7900 Electronic Potentiometer, until balance is obtained. The T4900 can also be used for power factor (Cos f) control in parallel operation with the grid. One unit is required for each generator. T5000 Paralleling Relay T4800 Load Sharer The T4400 is a load sharer for generators with electronic speed controllers. It includes a built-in frequency control and an integration function, providing a very high overall stability and compensate for any drift within the engine speed controller. A soft load/unload function is also provided. When activated, the T4400 will slowly increase or decrease speed to transfer load to or from the generator. A built-in relay can automatically trip the circuit breaker when unload is completed. The T4400 has a built-in reverse power protection with selectable limit and time delay. One load sharing unit T4400 is required for each diesel generator in parallel operation. The load sharers are interconnected with a 2-wire cable. When applied with the B9300 Power Reference Unit, one or several generators can be operated in parallel with the grid. The T4800 provides automatic load sharing and system frequency control of generators running in parallel. The load on each generator is compared with the load of the other generators and adjusted via the electric servomotor on the speed governor or a motorized potentiometer until balance is obtained. An unloading function is built into the unit to facilitate smooth transfer of the load from a generator before being taken out of service, by an automatic tripping signal to the breaker. The unit also has reverse power protection. One T4800 unit is required for each diesel generator in parallel operation. More T4800 units interconnected with a 2-wire cable. When applied with the B9300 Power Reference Unit, one or several generators can be operated in parallel with the grid. The T5000 can be used as a synchro nizing aid or as a check synchronizer. It will give a closing signal to the generator circuit breaker when voltage difference, phase difference and frequency difference are within safe limits, thus preventing damage or disturbance to the power plant. E7800 Motorized Potentiometer MOTORIZED E 7800 20 30 10 40 0 50 The E7800 can be used as an intermediate unit between the electronic speed controller and the SELCO automatic synchronizers or load sharers. For voltage regulation it can be applied with the T4900 VAr Load Sharer. 60 70 90 100 80

The E7800 Motorized Potentiometer can also be used as an individual standalone unit for many industrial applications. INSULATION BLACKOUT LOAD DEPENDING START & STOP MASTER TIME CONTROL RE Available for AC or DC supply with the DC versions being equipped with a step motor for adjustable speed. Flush mounted unit with standard measurements of 96 x 96 x 75mm. ALARM INDICATION ALARM INDICATION M8100 Synchroscope REVERSE POWER EXCITATION LOSS REVERSE POWER EXCITATION LOSS SYNCHROSCOPE TOO SLOW SYNC TOO FAST OVERCURRENT OVERCURRENT SHORT CIRCUIT SHORT CIRCUIT BUS GEN TACHO SYNCHRONIZING TACHO SYNCHRONIZING The M8100 provides illuminated indication of the actual phase difference between generator voltage and busbar voltage. ENGINE CONTROLLER LOAD SHARING VAr LOAD SHARING ENGINE CONTROLLER LOAD SHARING VAr LOAD SHARING When obtaining phase accordance, the two green LEDs at 12 o clock will indicate and the generator circuit breaker can be closed. GOVERNOR MOTOR AVR GOVERNOR MOTOR AVR The unit can be supplied with an optional integrated paralleling relay. Flush mounted unit with standard measurements of 96 x 96 x 80mm. B9300 Power Reference Unit Typical equipment applied for three diesel generators and one shaft generator POWER REF. UNIT B9300 0 10 ON The B9300 is applied in connection with SELCO Load Sharers T4400 and T4800, when running in parallel with the grid (utility). The unit determines the power to be supplied from the generators to the grid, adjustable 0-100%. Flush mounted unit with standard measurements of 96 x 96 x 75mm. T7900 Electronic Potentiometer The T7900 Electronic Potentiometer is typically used as an interface between increase and decrease contacts and a device requiring control / adjustment by a voltage or current signal, such as an electronic speed controller. In such applications, the T7900 acts similar to a motorized potentiometer, only the output can be a voltage, a current or a pulse width modulated signal (PWM), while the motorized potentiometer has a resistor output. Basic configuration is easily done by standard dials and dip switches while advanced configuration is accessible by PC. The PC configuration is done by a standard ANSI terminal in clear text. The T7900 can also be used as a programmable power reference unit (like the SELCO B9300). The power reference facility provides programmable increase/decrease ramps as well as eight pre-programmable target settings. A 0-10 VDC output is also provided for remote indication of the output level (0-100 %).

POWER FERENCE FREQUENCY VOLTAGE POWER FREQUENCY DEVIATION T2000 Reverse Power Relay φ ALARM INDICATION ALARM INDICATION REVERSE POWER EXCITATION LOSS OVERCURRENT SHORT CIRCUIT REVERSE POWER EXCITATION LOSS OVERCURRENT SHORT CIRCUIT The T2000 will, during parallel operation, prevent the generator from running as a motor, thus protecting the prime mover e.g. a diesel engine and unloading the remaining generators by tripping the generator breaker. T2100 Excitation Loss Relay TACHO SYNCHRONIZING SYNCHRONIZING ENGINE CONTROLLER LOAD SHARING VAr LOAD SHARING VAr LOAD SHARING φ GOVERNOR MOTOR AVR MOTOR AVR The T2100 protects against partial or complete excitation loss on the synchronous generator. If a generator under parallel operation has a low excitation, a high inductive current is running into the generator. This current is detected and the faulty generator breaker is tripped, thus avoiding overload on the other generators with a possible blackout of the system. Generator protection and power monitoring The Selco T-line range also includes a wide selection of protection relays and units for monitoring of the bus-bar and generator voltage, frequency and insulation, as well as detection of blackout. The trip levels and the delays before trip are easily adjustable using dials at the front cover. Some units also furnish an adjustable hysteresis setting. T2200 3 Phase Overcurrent Relay The T2200 has a broad application, where all 3 phases or any single phase current detection will function as protection, control or monitoring. The relay detects the highest of the 3 input currents and, when the preset value is exceeded, an output relay will be activated after a preset time delay.

Complete Protection of Generators T2700 Overload Relay P (kw) T2500 Overcurrent and Short Circuit Relay The relay detects the highest of the 3 input currents and, when the preset values are exceeded the output relays will be activated after preset time delays. T2500 3 Phase Overcurrent and Short Circuit Relay I x Cos f f I I x Sin f Q (kvar) T2100 Excitation Loss Relay Generator s Permitted Area of Operation T2000 Reverse Power Relay This figure illustrates the complete protection of a generator. The green shaded area illustrates the permitted area of operation for a generator. This information is normally supplied by the generator manufacturer. The vertical axis represents the active power, and the horizontal axis represents the reactive power. The active power is represented by I x Cos f. The T2700 Power Relay measures I x Cos f, and when it becomes too high, the relay will trip, indicated by the upper horizontal red line. The T2500 is intended for protection of generators, power transmissions and consumer supply against thermal damage and faults caused by high currents, with consequent tripping of the system breaker. The relay detects the highest of the 3 input currents and, when the preset values are exceeded, the output relay will be activated after preset time delays. T2600 Dual Current Relay The Reverse Power relay measures -I x Cos f, representing the active power in the negative direction, and it will trip for reverse power. The T2100 Excitation Loss Relay measures -I x Sin f, representing the reactive power in negative direction, and it will trip when exceeding the level represented by the red vertical line. The T2500 Overcurrent and Short Circuit Relay measures the magnitude of the current and thus protects against current levels outside the area of the red circle. T2300 3 Phase Short Circuit Relay The T2300 is intended for protection of generators, power transmissions and consumer supply against damage caused from short circuit by tripping the circuit breaker. The relay detects the highest of the 3 input currents and, when the preset value is exceeded, an output relay will be activated instantly (100 msec.) or after a preset time delay. T2400 3 Phase Dual Overcurrent Relay The T2400 furnishes 2 combined overcurrent relays, intended for protection or monitoring of generators, power transmissions and consumer supply. A typical generatorapplication is to let one of the overcurrent functions trip the generator breaker and to let the other overcurrent function trip a nonessential service. Both overcurrent functions could be used to trip 2 levels of nonessential loads. (Widely used in marine applikations) The T2600 determines load depending start and stop levels of a standby diesel generator. When load increases on the running diesel generators more than e.g. 90%, adjustable, for a preset time, a start signal to call for the standby diesel gene rator will be provided. If the load decrea ses below e.g. 45%, adjustable, for a preset time, a stop signal will be provided to stop the standby diesel generator. The T2600 can serve an installation with up to 3 diesel generators. With an extension unit additional generators can be served.

T2700 Power Relay T3000 Frequency Relay T3200 Insulation Monitor φ The T2700 is intended for detection of power level for protection, control and monitoring purposes. The relay detects the magnitude of the power and, when the preset value is exceeded, an output relay will be activated after a preset time delay. T2800 Overcurrent or Earth Fault Relay The T3000 is intended for effective frequency monitoring on generators, busbars or other distribution systems. The relay contains the functions under frequency and over frequency, time delayed, and 2 individual output relays, one relay for each function. T3100 and T3300 Voltage Relays The T3200 is intended for continuous insulation monitoring on 3 phase insulated networks on board ships. The relay continuously monitors two systems galvanically separated from each other, e.g. the busbar and the lighting system or two busbar systems. The unit features two output relays for alarm purposes and two analog outputs for instrument readings. T3500 Frequency Deviation Relay The T2800 has a broad application as an earth fault or a single phase overcurrent detection relay. It has a wide setting range for protection, control or monitoring. The relay detects the magnitude of the current and, when the preset value is exceeded, an output relay will be activated after a preset time delay. T2900 3 Ph. Differential Current Relay The T3100 and T3300 are intended for effective voltage monitoring on generators, busbars or other distribution systems. The relays contain the functions under voltage and over voltage, time delayed, and 2 individual output relays, one for each function. T3100 is for monitoring on one phase and T3300 is for 3 phase monitoring. T8400 Blackout Limiter Rate of change of frequency (ROCOF) relay, df/dt relay. The T3500 will monitor the frequency of the connected busbar. In case there is a rapid change of frequency, the relay will trip. 11 12 13 14 15 16 17 18 19 20 POWER RELAY 3-PHASE DIFF. CURRENT RELAY T2900 0.16 0.04 xi N 0.28 0.4 1 4 SEC. 7 10 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 The T2900 3 Phase Differential Relay is intended as a protection relay for generators, power transmissions and consumer s supply by tripping the main circuit breaker. The T2900 measures the differential current of each of the 3 phases. The relay detects the highest of the 3 input currents and, when the preset values are exceeded, the output relay will be activated after preset time delays. The T8400 enables fast clearing of a blackout. If a blackout occurs, the first generator to have more than 90 % voltage will make the generator breaker close. It is possible to monitor up to 4 generators with 1 unit, and up to 8 generators with 2 units.

About SELCO Since the origin in 1960, SELCO technology has provided the electrical power generation market with high class equipment, living up to the major international standards. Generator Control, Protection & Monitoring Generator protection: Short circuit, overcurrent, reverse power, excitation loss, engine protection. Generator controls: Synchronizing, frequency control, active and reactive load sharing, load control, power management, engine control. Generator monitoring: Voltage, frequency, power, insulation. Alarm Annunciation and Indication Monitoring of current, temperature or pressure Indication of alarms Logging of alarms and events Arc Detection Arc detecting relay Current relay Time relay SELCO Worldwide The SELCO equipment has been thoroughly tested by certified laboratories with regard to high vibration levels, heat, cold, humidity, salt mist, EMC emission and immunity as well as other parameters. SELCO products are in accordance with all significant international standards and have been approved and certified by the major marine classification societies. SELCO Denmark SELCO representation Area of supply Main Office: SELCO A/S Betonvej 10 DK- 4000 Roskilde Denmark Tel.: + 45-70 26 11 22 Fax: + 45-70 26 25 22 e-mail: selco.dk@selco.com www.selco.com SELCO China Ltd. Room 428 550 Mincheng Road 200135 Shanghai Pudong China Tel.: + 86-2150281391 Fax: + 86-2150282025 e-mail: tp_he@selco-china.com.cn SELCO ME L.L.C P.O. Box 52898 Dubai United Arab Emirates Tel.: + 971-4 3413660 Fax: + 971-2 3413770 e-mail: selco.ae@selco.com SELCO SE Asia Pte. Ltd. 50, Tuas Lot, Tuas Avenue 11, #3-25 Singapore 639107 Singapore Tel.: +65 6316 2204 Fax: +65 6316 2203 e-mail: selco.sg@selco.com Q1006-103UK Cool Gray A/S