Contemporary Collection

Similar documents
Contemporary Collection

U1500E Gas Fireplace

Contemporary Collection

Regency Bellavista B41XT-1 Gas Fireplace

HZO60 Outdoor Decorative Fireplace

Manual FOR YOUR SAFETY. Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance.

Never fill any required clearance space with insulation or any other building materials surrounding the chimney.

HEARTH PRODUCTS KITS AND ACCESSORIES VERTICAL TERMINATION KITS FOR SECURE FLEX VERTICAL VENTING

SOUTHWEST KIVA 24 FIREPLACE Prefabricated Masonry Wood Burning Firebox and Metal Frame

TYPE "B" GAS VENT. Do not connect gas vent to a solid or liquid fuelled appliance or any appliance requiring a chimney.

Zero Clearance Fireplace 36 ELITE-ZC INSTALLATION MANUAL. Listed Tested to: U.L. 127 and portions of U.L & 907. Part # $10.

Zero Clearance Fireplace 44 ELITE-ZC INSTALLATION MANUAL. Listed Tested to: U.L. 127 and portions of U.L & 907. Part # $10.

contemporary gas fireplaces

ECOVENT USA CHIMNEY MODEL EV-SHT 5"-8" DIAMETER INSTALLATION INSTRUCTIONS

C Series. Cool Surface System INSTRUCTION MANUAL FRONT VENT [ ] PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE

ICC INDUSTRIAL CHIMNEY COMPANY INC. ST-JEROME, QUÉBEC, CANADA, J7Y 4B7 TEL: (450) FAX: (450)

Kiva Fireplace WOOD BURNING INSTALLATION MANUAL

GAS FIREPLACES TRADITIONAL. TRADITIONAL GAS FIREPLACES

INSUL-FLUE is used to reduce the danger of radiant heat from smoke pipe, flue pipe, gas vents, etc. igniting combustibles.

GAS FIREPLACES TRADITIONAL. TRADITIONAL GAS FIREPLACES

GAS FIREPLACES TRADITIONAL. TRADITIONAL GAS FIREPLACES

DURATECH CHIMNEY 5"-8" DIAMETER INSTALLATION INSTRUCTIONS

ICC INDUSTRIAL CHIMNEY COMPANY INC. ST-JÉRÔME, QUÉBEC, CANADA, J7Y 4B7 TEL: (450) FAX: (450) INSTALLATION AND OPERATION INSTRUCTIONS

The following manual is for the 80ZC cabinet ONLY. If you require information on the Model 80 unit that fits inside this cabinet, please download the

GE Monogram. Installation. Instructions. 36" Vent Hood. Model ZV750. Call anywhere in the US and Canada -

150 MM FREE STANDING WOOD FIRE FLUE KIT INSTALLATION INSTRUCTIONS

650 C TEMP/GUARD CHIMNEY SIZES ºC TEMP/GUARD CHIMNEY

VERTICAL BALANCED FLUE SYSTEM INSTALLATION INSTRUCTIONS

Installation & Maintenance Instructions

DURA-PLUS (SDP) INSTALLATION AND OPERATION INSTRUCTIONS MH7399

WOOD FIRE FLUE KIT AND ACCESSORIES MANUAL

Our non-positional lock system on the Selkirk. The Locktab is located on the female end of the gas vent.

INSTALLATION INSTRUCTIONS for PYROCLASSIC FIRES LTD. 100mm SLOPING CEILING FLUE KIT

Kiva Fireplace GAS BURNING INSTALLATION MANUAL WITH DOUBLE WALL AIR COOLED CHIMNEY

Installation Instructions. All-Fuel Chimney System 5 to 8 diameter. DuraTech

Earthcore Air-Cooled ECO-Steel Chimney is not designed for use on products that operate at continuous temperatures in excess of 1000 F.

LE7000 Provincial Built-in (Zero Clearance) Kit Instructions.

ULTRA-TEMP TM. INSTALLATION INSTRUCTIONS & MAINTENANCE GUIDE (Canada Only) MODEL. (5 to 8 inches dia.) FACTORY-BUILT INSULATED CHIMNEY

ProBuilder Linear CoolSmart TV (42PB - sku# )(54PB - sku# )(72PB - sku# )

EXCEL FACTORY BUILT CHIMNEY INSTALLATION AND MAINTENANCE INSTRUCTIONS

Installation Instructions. All-Fuel Chimney System 5 to 8 diameter. DuraTech

SECURE-TEMP ASHT + CANADA OUR PRODUCTS LIVE UP TO OUR NAME, WARNING... 2 GENERAL INFORMATION, USA & CANADIAN APPLICATIONS.. 11

FACTORY BUILT INSULATED CHIMNEY

TECHNICAL GUIDE BEONSTONE PANELIZED STONE SIDING

MM700R Recess Box Kit Addendum

Accentra 52i Pellet Insert Zero Clearance Cabinet Part #

SLP-LPC. Installation & Operating Instructions. SLP-LPC Preparation

Installation Instructions. All-Fuel Chimney System 10 to 24 diameter. DuraTech

Chaska 34, Chaska 335s, Chaska 29, Chaska 25

CHASKA 34, CHASKA 335S, CHASKA 29, CHASKA 25

YOUR LIFE. YOUR FIRE. Ortal Curved & Islands Fireplaces Installation Manual. Ortal USA - Version: 1.3 November, 2017 SKU: KPMANCIRISLUS17B

Crave Series. Direct Vent Gas Fireplaces

10. Vents, Baffle Guard and Blocking

Regency Horizon HZ30E Contemporary Direct Vent Gas Fireplace

MM540 Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

Dura-Lock Roof System

Versatrac R-System Stock Extrusions, Clips and Accessories

60/100 Concentric Flue System Parts

ProBuilder Series CoolSmart TV (42PB - sku# )(54PB - sku# )(72PB - sku# )

HowtoPlans..org. 12'x20' Garden Shed Plan

PLEASE READ AND UNDERSTAND THE REQUIREMENTS BEFORE PROCEEDING

Versatrac R-System Stock Extrusions, Clips and Accessories

CHASKA 34, CHASKA 335S, CHASKA 29, CHASKA 25

SINGLE TRACK BYPASS (patent pending) barn door hardware

Installation Instructions For Slider Casement Air Conditioners

kééç=eéäé\ =KKK`çåí~Åí=ìë=~íW çêiîáëáí=ìë=çåäáåé=

Installation Guide Classic Series Wood Siding

HowtoPlans..org. DuraMax 8'x12 Garden Shed Plan

Fireside Retreat. Craftsman-Style BEFORE

NEW HOME WARRANTY A REFERENCE GUIDE FOR TYPICAL WALL AND WINDOW DETAILS (RAINSCREEN SYSTEM) SHOWN AS FIBRE CEMENT CLADDING

ZERO CLEARANCE MANUAL

Installation Instructions

ULTRA-TEMP TM. INSTALLATION INSTRUCTIONS & MAINTENANCE GUIDE (Canada Only) MODEL. (5 to 8 inches dia.) FACTORY-BUILT INSULATED CHIMNEY

Vertical Offset Base and Safety Rail System Installation Instructions

MantelMount. TM1A Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

GLOSSARY OF TERMS SECTION 8

gas fireplace inserts

Household Appliances. Over-the-Range Microwave. Installation Instructions. For Models: HMV9302, HMV9305, HMV9306, HMV9307

MM750 Installation Instructions

MM340 Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

FLEXIBLE CHIMNEY LINER PRODUCT CATALOGUE

Installation Guide for Andersen 400 Series Tilt-Wash Transom and 200 Series Narroline Transom Windows

YOUR LIFE. YOUR FIRE. Ortal Curved & Islands Fireplaces User s Manual

GAS FIREPLACES INSERTS. GAS FIREPLACES INSERTS

Piping & Equipment Identification

DuraPlus. Installation Instructions. All-Fuel Chimney System. C o m p l e t e V e n t i n g S o l u t i o n s

HowtoPlans..org. Skyline 10'x14' Garden Shed Plan

Installation Instructions. All-Fuel Chimney System. DuraPlus

HR175 Sash Replacement Kit Installation Instructions

HowtoPlans. 24'x8' Walk In Chicken Coop Plan. Designed for up to 50 chickens. .org

GAS FIREPLACES INSERTS. GAS FIREPLACES INSERTS

HRI4E REGENCY HORIZON MEDIUM GAS INSERT STANDARD FEATURES. HRI4E shown with Regular Backing Plate, Vignette Faceplate in Platinum and Black Crystals.

Type B Gas Vent GV-25 CATALOG FEATURES. Round and oval gas vent pipe and fittings for residential, commercial and industrial applications.

Panel Installation Instructions

FASTENERS BUILDING DEPARTMENT

Installation Guide. Model #400. Corporate Office: 349 Highland Road East Macedonia, Ohio

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS

Woodburning appliances price list

CATALOG. Stainless Steel Flexible Chimney Liner

Woodburning appliances price list

Transcription:

HZ5E Gas Fireplace Model HZ5E-NG1 HZ5E-LP1 Fuel Type Natural Gas Propane Gas Minimum Supply Pressure 5 W.C.(1.5 kpa) 1 W.C. (.98 kpa) Manifold Pressure - High 3.5 W.C. (.87 kpa) 1 W.C. (.9 kpa) Manifold Pressure - Low 1.6 W.C. (. kpa) 6. W.C. (1.59 kpa) Orifice Size #3 DMS #9 DMS Minimum Input Altitude -5 ft. (-137m) Maximum Input Altitude -5 ft. (-137m) 9, BTU/h (8.5 kw) 3, BTU/h (8.79kW) 1,5 BTU/h (1.16 kw) 37, BTU/h (1.8 kw) Vent Sizing 5 Inner / 8 Outer 5 Inner / 8 Outer Approved Venting Systems Flex Vent Systems: Rigid Pipe Vent Systems: FPI AstroCap Flex Vent Simpson Direct Vent Pro Selkirk Direct-Temp Metal-Fab Sure Seal Unit Dimensions: Faceplate & Door Frame Dimensions:

CLEARANCES The clearances listed below are Minimum distances unless otherwise stated: A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions. Caution Requirements The top, back and sides of the fireplace are defined by standoffs. The metal ends of the standoff may NOT be recessed into combustible construction. WARNING Fire hazard is an extreme risk if these clearances (air space) to combustible materials are not adhered to. It is of greatest importance that this fireplace and vent system be installed only in accordance with these instructions. Clearance: Dimension Measured From: A: Mantel Height (min.) " (58mm) Top of Fireplace Opening B: Sidewall (on one side) " (1mm) Side of Fireplace Opening C: Ceiling (room and/or alcove) -7/8" (138mm) Top of Fireplace Opening D: Mantel Depth (max.) 13" (33mm) 3" Above Fireplace Opening E: Alcove Width 83" (18mm) Sidewall to Sidewall (Minimum) F: Alcove Depth 36" (91mm) Front to Back Wall (Maximum) G: To Floor 8-7/8" (733mm) Top of Fireplace Opening Note " No hearth required Heat Release Kit The HeatWave Duct Kit and the Heat Release Kit have different clearance and framing requirements, check the HeatWave and Heat Release manual for details. Flue Clearances to Combustibles Horizontal - Top 3" Horiztonal - Side " Horiztonal - Bottom " Vertical " Passing through wall/ floor/ceiling - when firestop is used. 1-1/" C D F F B A B G E Installed Close to Floor Installed Close to Ceiling NON-COMBUSTIBLE REQUIREMENTS Wood Stud 6-1/" (1537mm) Metal Stud (header) Wood Stud 19-7/8" (55mm) Non-combustible Material -1/ (57mm) Non-combustible Material -5/8 5-7/8 Non-combustible Material Non-combustible Material -3/8 (179mm) 3-7/8" ( 99mm) 5-1/ (1mm)

FRAMING DIMENSIONS NOTE: If not purchasing the optional steel stud kit - adhere to the same framing if purchasing steel studs elsewhere. The use of the optional kit is highly recommended as it was designed specifically for the product to facilitate ease of installation. Framing Dimensions Description HZ5E A Framing Height 6-5/8 (118mm) B Framing Width 6 (15mm) C* Framing Depth* 3-3/ (63mm) D Minimum Height to Combustibles 51 (195mm) E Corner Wall Depth 69" (1753mm) F Corner Facing Wall Width 97-9/16 (78mm) G Vent Centerline Height (1118mm) H Non-combustible facing height (58mm) I Gas Connection Opening Height 1-1/ (38mm) J Gas Connection Height (1mm) K Gas Connection Inset 7-1/ (18mm) L Gas Connection Opening Width 3-1/ (83mm) * Framing depth measurement is noted with the side nailing strips set as far forward on the firebox as possible. The side nailing strips can be adjusted back up to 3-1/8 to allow for varying thicknesses in non-combustible material & wall finishes. Important: The minimum framing dimensions given for height, width and depth must be maintained even if using non combustible materials. Dangerous operating conditions will occur if minimum framing dimensions are not adhered to.

1. Construct the wood framing, ensure the inside dimensions are 63" W x 5-1/*" H OPTIONAL FRAMING KIT OPTIONAL FRAMING KIT 5-1/" 63" Flat side out (78-15) 5. Secure horizontal steel header with screws per diagram. Bend both nailing strips from the sides of the appliance until positioned as shown below. Determine the overall combined thickness of the non-combustible board +finished material being used. The nailing strips can be adjusted 3-1/8". (78-16) 3. Adjust nailing strips by loosening screws on each nailing strip - adjust and retighten the screws. Attach both vertical studs (78-15) and secure using 6 screws ( at bottom, at top and on the sides) as shown 6. Slide the unit in position. Hook up gas, venting and electrical and fan (if purchased) prior to installing the remaining horizontal steel studs. 7. Secure 3 horizontal steel studs (78-16) with screws on each end. at the top and one at the bottom as shown. NOTE: Ensure the flat side of the steel stud is facing the wood framing. 1 3

FRAMING & FINISHING 1) Frame in the enclosure for the unit with framing material. IMPORTANT: Header must be metal stud. All other framing may be of combustible type such as x / x6 framing materials. Note: When constructing the framed opening, please ensure there is access to install the gas lines when the unit is installed. ) For exterior walls, insulate the enclosure to the same degree as the rest of the house, apply vapour barrier and drywall, as per local installation codes. (Do not insulate the fireplace itself.) WARNING: Failure to insulate and add vapor barriers to the inside of the exterior wall will result in operational and performance problems including, but not limited to: excessive condensation on glass doors, poor flame package, carbon, blue flames etc. These are not product related issues. 3) The unit does not have to be completely enclosed in a chase. You must maintain clearances from the vent to combustible materials: See "Clearances" section. Combustible materials can be laid against the side and back standoffs and the stove base. ) When finishing around the faceplate, if material such as brick, stone, etc. extend past the faceplate depth due to the finished material exceeding 3-1/8" - the minimum opening dimensions noted below must be adhered to, this is to ensure removal of the faceplate. Faceplate and Door Frame-Perfect Edge Design Important: Determine the nailing strip position by determing the facing material being used. Examples: 1/" non-combustible wall board for clean finish = -5/8" adjustment. 1/" non-combustible wall board + 1/" tile = 1" of finished material = -1/8" adjustment. Note: For material such as brick, stone, etc that extends 3-1/8" or less, the minimum opening dimensions noted below must be adhered to when finishing around the unit. This is to ensure the removal of the faceplate and for the safe operation of this appliance. Depending on the material used for finishing, the nailing strips must be set accordingly so that the finished material is always at the 3-1/8" edge of the flange. 5-7/8-5/8 Unit shown without faceplate for Illustrative purposes only NOTE: The Verona Glass Surround (not shown) requires a: 6-1/16" W x 8 5/8" H opening

MANTEL CLEARANCES Due to the extreme heat this fireplace emits, the mantel clearances are critical. Combustible mantel clearances from top of front facing are shown in the diagram on the right. Note: A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non-combustible board. 3 1 1 1 8 6 13" (33mm) Combustible Material Note: Ensure the paint that is used on the mantel and the facing is "High Quality" or the paint may discolour. 3 ½" (89mm) 1" (5mm) Drywall 1 3 1 Metal Stud (On Edge) Non-combustible facing. Must be supported using steel stud or Standoff the framing kit 8-1/8 To Unit Base Legs Top of Fireplace Opening MANTEL LEG CLEARANCES Combustible mantel leg clearances as per diagram: MANTEL LEG (1mm) Non-Combustible 7" " 1.5" (38mm) Allowable mantel leg projection 5-1/ (1mm) 8 (3mm) 11 (79mm) 6

Contemporary Collection VENTING ARRANGEMENTS ALLOWABLE VERTICAL TERMINATIONS FOR HZ5E-NG1 The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations, using two 9 o elbows, with Rigid Pipe Venting Systems for Natural Gas. Two 5 o elbows equal to one 9 o elbow. Maximum of four 5 o elbows allowed. Vent must be supported at offsets. Firestops are required at each floor level and whenever passing through a wall. Maintain clearances to combustibles as listed in the Clearances section. Refer to the Vent Restrictor Position section for details on how to change the vent restrictor from the factory setting of Set 1 to Set or Set if required. Note: Must use optional flue adaptor when using Rigid Pipe (Part # 77-99) Horizontal (Feet) 6 8 1 1 1 16 18 38 36 3 3 Maximum: ft. (1.m) 3 Vent Restrictor on Set 8 6 Vertical Height (Feet) 18 16 Vent Restrictor on Set Maximum: 7 ft. (8.m) 1 1 1 Vent Restrictor on Set 1 (factory setting) Please note min. 1 foot between 9 o elbows is required. 8 6 Min. (1118mm) Minimum 8 6 (.6m) Minimum length of pipe between elbows 1 (35mm) Max. 1 (3m)(centerline to centerline)

Contemporary Collection VENTING ARRANGEMENTS ALLOWABLE VERTICAL TERMINATIONS FOR HZ5E-LP The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations, using two 9 o elbows, with Rigid Pipe Venting Systems for Propane. Two 5 o elbows equal to one 9 o elbow. Maximum of four 5 o elbows allowed. Vent must be supported at offsets. Firestops are required at each floor level and whenever passing through a wall. Maintain clearances to combustibles as listed in the "Clearances" section. Refer to the "Vent Restrictor Position" section for details on how to change the vent restrictor from the factory setting of Set 1 to Set or Set 5 if required. Note: Must use optional flue adaptor when using Rigid Pipe (Part # 77-99). Horizontal (Feet) 6 8 1 1 1 16 18 38 36 3 3 Maximum: ft. (1.m) 3 Vent Restrictor on Set 5 8 6 Vertical Height (Feet) 18 16 Vent Restrictor on Set Maximum: 7 ft. (8.m) Please note min. 1 foot between 9 o elbows is required. 1 1 1 Vent Restrictor on Set 1 (factory setting) 8 6 Min. (1118mm) Minimum 8 6 (.6m) Minimum length of pipe between elbows 1 (35mm) Max. 1 (3m)(centerline to centerline)

VENTING ARRANGEMENTS ALLOWABLE HORIZONTAL TERMINATIONS The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 9 o (two 5 o elbows equal one 9 o elbow). Note: Must use optional rigid pipe adapter (Part# 77-99) when using Rigid Pipe Venting Systems. HZ5E-NG1 Horizontal (Feet) 6 8 1 1 1 16 18 18 16 Vent Restrictor on Set 3 Vertical Height (Feet) 1 1 1 8 Vent Restrictor on Set Vent Restrictor on Set 1 (factory setting) 6 (1118mm) Minimum Height Requirement HZ5E-LP1 Horizontal (Feet) 6 8 1 1 1 16 18 18 16 Vertical Height (Feet) 1 1 1 8 Vent Restrictor on Set Vent Restrictor on Set 1 (factory setting) 6 (1118mm) Minimum Height Requirement

These venting systems, in combination with the HZ5E, have been tested and listed as a direct vent system by Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram from the Exterior Vent Termination Locations section. FPI Kit # Length Contains: #96-615 Feet 1. 8 flexible liner (Kit length). 5 flexible liner (Kit length) 3. spring spacers #96-618 6 Feet. thimble 5. AstroCap termination cap 6. screws #96-616 1 Feet 7. tube of Mill Pac 8. plated screws 9. S.S. screws #8 x 1-1/ drill point 1. vinyl siding standoff Rigid Pipe Vent Systems offer a complete line of component parts for installation of both horizontal and vertical installations. Many items are offered in decorative black, as well as galvanized finish. The minimum components required for a basic Horizontal Termination are: 1 AstroCap XL Termination Cap 1 9 o Elbow 1 Rigid Pipe Adaptor 1 Wall Thimble 1 Length of rigid pipe to suit wall thickness The minimum components required for a basic Vertical Termination are: 1 Vertical Termination Cap 1 Rigid Pipe Adaptor 1 Lengths of pipe to adequately penetrate roof 1 Ceiling Firestop 1 Flashing 1 Storm Collar Wall thickness is measured from the back standoffs to the inside mounting surface of termination cap. For siding other than vinyl, furring strips may be used, instead of a vinyl siding standoff, to create a level surface to mount the vent terminal. The Terminal must not be recessed into siding. Measure the wall thickness including furring strips. If a Vinyl Siding Standoff is required (it must be used with vinyl siding), measure to outside surface of wall without siding and add inches. Vertical Terminal 5 dia. flue pipe 8 dia. Flue pipe Vinyl Siding Standoff Wall Thimble (Mandatory in all Horizontal T erminations) spring spacer TM AstroCap XL Termination Cap (Part #96-63/P) Vent Guard - if required* (Part #96-56/P) Storm Collar Flashing Ceiling Firestop Pipe Length Pipe Length Vinyl Siding Standoff (Optional) Pipe Length Vent Guard -if required* (Part #96-56/P) AstroCap XL Termination Cap (Part #96-63/P) Wall Thimble (Mandatory in all Horizontal Terminations) o 9 Elbow Rigid Pipe Adaptor (77-99)