Current and voltage measuring relays RXIK 1, RXEEB 1 and RXIB 24

Similar documents
Transformer and generator time-overexcitation relay and protection assemblies RXLK 2H and RALK

Time relay RXKA 1. (xx jpg) RXKA 1

Harmonic restraint earth fault or single-phase overcurrent protection

Transformer differential protection

Phase and neutral overcurrent protection

Compact current relay and protection assemblies RXHL 401 and RAHL 401

Earth fault protection for isolated neutral systems with frequency converters

Time over/underfrequency relay with protection assemblies

RARIC Shaft current protection

Time-overcurrent relays and protection assemblies

)HDWXUHV Voltage restraint overcurrent stage with five different inverse or definite time characteristics

Modular multifunction generator protection

Transformer differential protection RADSB

Stabilized Differential Relay SPAD 346. Product Guide

Types CDG 11 and CDG 16 Inverse Time Overcurrent and Earth Fault Relay

INDICATOR TYPE RXSK 2H

Instantaneous Overcurrent Relay

CDV 22, 62. Voltage Controlled Overcurrent Relay GRID PROTECTION

All-or-nothing relay RH(M) 1000 in plug-in case and case for top-hat rail or wall mounting

Catalogue 1SFC en, Edition 3 November 2003 Supersedes Catalogue 1SFC en, Edition 2 November Arc Guard System TVOC

SPAD 346 C Stabilized differential relay

XUA1 AC Voltage and phase balance relay. (August 1996) Manual XUA1 (Revision New)

Overcurrent Protection / 7SJ45

SPAE 010, 011 High Impedance Protection Relay

Fault indicator. Application. SPEF 3A2 C 1MRS MBG Issued: April 1999 Status: Updated Version: B/ Data subject to change without notice

Relion 605 series Self-Powered Feeder Protection REJ603 Product Guide

ABB Automation Products AB

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

High-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

XI1-I Time overcurrent relay. (Januar 2007) Manual XI1-I (Revision New)

XR1 Rotor Earth Fault Relay. Manual XR1 (Revision C)

Electronic relays. Monitoring. Monitoring

Multimeter 500CVD21 RTU500 series

DEIF A/S. Insulation monitor. Type SIM-Q

Three-phase monitoring relay

Mors Smitt Industrial Technology. High performance plug-in relays

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

Static Breaker Back-up Relay Type SBC Relay SBC231B

XP2-R Power and reverse power relay. (January 2006) Manual XP2-R (Revision New)

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

POWER TRANSDUCERS ACTIVE AND REACTIVE SERIES: T-W WATT T-V VAR

XP2-R Power and Reverse Power Relay

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 29000

N. TEST TEST DESCRIPTION

IRI1-ER - Stabilized Earth Fault Current Relay. Manual IRI1-ER (Revision A)

IRI1-ER - Stabilized Earth Fault Current Relay

Functional Range. IWE - Earth Fault Relay. C&S Protection & Control Ltd.

XU2-AC AC voltage relay. (Februar 1997) Manual XU2-AC (Revision New)

XUA1 - AC Voltage and phase balance relay

RXFK 2H and RAFK Time over/underfrequency relay and protection assemblies

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

RAIDK, RAIDG, RAPDK and RACIK Phase overcurrent and earth-fault protection assemblies based on single phase measuring elements

Company Replaces previous document Document ID Issue E.ON Elnät Sverige AB Ny engelsk utgåva D

Plug-in microprocessor controlled multifuncional relay with automatic shorting of c.t.

DEIF A/S. Insulation monitor. Type SIM-Q/SIM-Q LF

Protection Basics Presented by John S. Levine, P.E. Levine Lectronics and Lectric, Inc GE Consumer & Industrial Multilin

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

7PG21 Solkor R/Rf Pilot Wire Current Differential Protection Energy Management

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

3 Pole high impedance differential relay 7VH83

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Line protection REL 100

SIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Three-phase monitoring relays CM-PFE and CM-PFE.2

APPLICATION: The heart of the system is a DSR 100 Digital Static Regulator used in conjunction with standard SCR based rectifier bridges.

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

Advanced Test Equipment Rentals ATEC (2832)

High-Tech Range. IRI1-ER- Stablized Earth Fault Current Relay. C&S Protection & Control Ltd.

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81

Current monitor Type C 551

Type CAEM 21 Battery Earth Fault Relay

Three-phase monitoring relay CM-PBE

Electronic Circuit Breaker with reset input ESS20-1..

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Three-phase monitoring relay CM-PVE

Installation / Monitoring Technique

BE1-87G VARIABLE PERCENTAGE DIFFERENTIAL RELAY

SPECIFICATION FOR OVERCURRENT RELAYS

Three-phase monitoring relays CM-PVS.81

SPECIFICATION, CONTROLS AND ACCESSORIES

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

Excitation Systems THYRIPART. Compound-Excitation System for Synchronous Generators. Power Generation

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

PRODUCT TEST MANUAL 2SY110K28 SYNCHRONISM CHECK RELAY

Type CP-S, CP-C & CP-A Switch mode

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Section L5: PRE-ENERGIZATION TEST PROCEDURES FOR LOAD-ONLY ENTITIES AND TRANSMISSION-ONLY ENTITIES

Type VAEM 22 Negative Potential Biasing Relay

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

MULTI FUNCTION OVER CURRENT AND EARTH FAULT RELAY[50/51X3,50/51N]

XF2 Frequency Relay. Manual XF2 (Revision A)

Three-phase monitoring relay CM-PFS

Automatic synchronising relay

Shortcomings of the Low impedance Restricted Earth Fault function as applied to an Auto Transformer. Anura Perera, Paul Keller

FREJA 306 Relay Testing System

N. TEST TEST DESCRIPTION

Transcription:

Current and voltage measuring relays RXIK 1, RXEEB 1 and RXIB 24 RXIK 1 (RXIK_1.tif) RXEEB 1 (RXEEB_1.tif) RXIB 24 (RXIB_24.tif) Features RXIK low current relay, 50-60 Hz and dc High sensitivity 0,5-2 ma ac Low power consumption in measuring circuit, 20 μw High overload capacity, 125 ma continuously RXIB high speed current relay, 50 or 60 Hz Operate time 4 15 ms Resetting time 5 11 ms 10 ma to 15 A total range for four models Low CT burden and high overload capacity RXEEB low voltage relay, dc High sensitivity 0,1-1,2 and 1-12 V dc 0-0,12 and 0-1,2 V setting of hysteresis Low power consumption in measuring circuit, down to 0,056 μw High overload capacity, 150 V continuously Application The current and voltage measuring relays are mainly intended for power and system industrial applications. The relays should be mounted on terminal bases and combined with auxiliary relays, time relays etc. The current relay RXIK 1 is used where high sensitivity is required, e.g. in the shaft current relay type RARIC, where a variant of RXIK 1 constitutes the measuring unit. When shunt connected, the relay can be used to measure large direct currents. The shunt wires may be long and have small area as the relay power consumption is very low. In conjunction with additional units, special versions of RXIK 1 may be used in e.g. overcurrent relays, neutral point voltage relays and differential relays to operate even at very low frequencies. The current relay RXIB 24 is generally used where highspeed and consistent operate and reset times are required. Its speed and consistency make the RXIB especially suitable for breaker-failure applications where it is important that the set breaker-failure time is not unduly influenced by variations in operate or reset time of the current-measuring relay. The RAICA breaker-failure relay, for example, incorporates the RXIB for its currentmeasuring function. Similarly, the RXIB s speed and precision in both operate and reset time are ideal for high-speed current-blocking relay applications. For example, to supervise the operation of transformer suddenpressure relays, which may operate incorrectly as a result of severe external faults. The RXIB is then used in a protective system which responds rapidly to the external fault condition, operating quickly enough to open the pressure relay trip circuit before the pressure- relay has operated. Additionally, this high-speed relay can be used to improve the security of other sensitive high-speed relays by modifying their pick-up setting without adversely affecting overall operating time. The RXIB should also be considered for high-set direct trip applications because of its high-speed and low transient overreach. The dc voltage relay RXEEB 1 has high sensitivity. The relay can be used in control circuits, to monitor and indicate voltage levels or, via a tachometer generator, rotation speed. The version with normally energized output terminal can also be used in equipment for lifts or cranes where, for safety reasons, failure to operate due to interruption of the auxiliary power supply is not accepted.

Design The RXIK 1 is a static, sensitive, high-speed ac and dc overcurrent relay with two changeover contacts. It consists mainly of a level detector with an amplifier, a potentiometer, RC-circuits and regulating (zener) diodes. The operate value is set with a knob at the front. To reduce the risk of undesired operation upon high frequency signals, the input has an RC circuit which causes the operate value of the relay to increase with the frequency. The output circuit has a smoothing filter which ensures stable function of the output relay. The measuring input is galvanically connected with the terminal for the auxiliary voltage (±12 V dc). Therefore the auxiliary voltage should be supplied via galvanically isolated converters. Suitable converters are RXTUG 22H for dc and RXTUB 2 for ac voltage. RXIK 1 can be used for measuring in both voltage and current circuits. The input is therefore connected both to current terminals 31 and 41 and to voltage terminals 21 and 22. A short-circuiting connector, type RTXK, is supplied with ac current measuring relays. The connector is mounted on the rear of the terminal base (not supplied). The relay current measuring is fed through the RTXK so that the current transformer secondary circuit is automatically short-circuited when the relay is removed from the terminal base. If the shortcircuiting function is not required, e.g. if RXIK 1 is connected to a shunt, connection can be made to the current terminals (31 and 41) via a connector RTXI or to the voltage terminals (21 and 22). The relay occupies one seat (2U 6C). The RXIB 24 is a static, high-speed ac overcurrent relay. It consists mainly of an air-gapped input current transformer with three setting taps on the primary side, voltage converter, rectifier, level detector, potentiometer for setting, and amplifier (which drives a reed-type output relay with one make contact). The voltage from the input CT is converted to a three-phase quantity to reduce the ripple volt-age at the output of the rectifier circuit. This technique reduces filtering requirements, thus contributing to the relay s high speed on both operate and reset. The operating value is set by means of the potentiometer knob which can be continuously adjusted from one to three times the scale factor (I s ). The scale factor (I s ) is changed by reconnecting a lead to one of three positions on a screw-type CT tap block, located at the lower right side of the module face plate. In order to avoid opening the CT secondary circuit, reconnection of the scale factor is only to be carried out when the relay is withdrawn from the terminal base. There are four sets of Reconnectible scale factors available: Scale factor, I s 10; 25; 50 ma 0,1; 0,25; 0,5 A 0,2; 0,5; 1 A 1; 2,5; 5 A Two variants of RXIB are available with respect to auxiliary voltage. One can be reconnected (via a screw-type block at the upper right side of the face plate) for dc 36 and 48-55 V, the other for dc 110-125, 220 and 250 V. Auxiliary voltage is normally supplied directly from the station battery. A short-circuiting connector, type RTXK, is supplied with ac current relay modules. This connector mounts on the rear of the terminal base (not supplied). The relay current measuring circuits is fed through the RTXK so that the current transformer secondary circuit is automatically short-circuited when the relay is removed from the terminal base. The relay occupies two seats (2U 12C). The RXEEB 1 is a static dc voltage relay with electronic output. It measures the absolute voltage or only the positive or negative dc voltage. The relay requires auxiliary voltage dc ±24 V or 48 V with the supply galvanically isolated from the input signal source. Auxiliary output relays suitable for use with RXEEB 1 are RXMA 1, RXMB 1, RXMC 1, RXMT 1, RXMM 1 or RXME 1. The relay occupies one seat (2U 6C). 2 Current and voltage measuring relays 1MRK508018-BEN Revision: B

Technical data RXIK 1 Current scale, I s Operate value dc Input impedance 0,5-2 ma, 50-60 Hz approx. 1,35 x set value 82 ohm Overload capacity Resetting ratio ac 125 ma cont. 500 ma in 1 s > 99% dc > 80% Operate time 10-30 ms at 1,3 x I s Resetting time approx. 200 ms at 10 x I s Auxiliary voltage ±12 V ±20% Permitted ambient temperature Power consumption: Current circuit Auxiliary voltage Insulation tests: Dielectric test Impulse test Disturbance tests: Power frequency test Fast transient test 1 MHz burst test Dimensions Weight -20 C to +55 C approx. 20 mva at lowest value 0,7 W before operation 1,3 W after operation 2,0 kv 50 Hz 1 min 5 kv 1,2/50 ms, 0,5 J 0,5 kv 50 Hz 4-8 kv 2 min 2,5 kv 2 s 2U 6C modules 0,2 kg Contact data: No. of contacts Max. system voltage ac or dc Current carrying capacity continuously during 1 s Making and conducting capacity with an inductive load L/R > 10 ms during 200 ms during 1 s Breaking capacity ac PF > 0,1 dc L/R < 40 ms 48 V 110 V 220 V 2 change-over 250 V 4 A 10 A 20 A 10 A 0,5 A 0,2 A 0,1 A Current and voltage measuring relays 1MRK508018-BEN Revision: B 3

Technical data RXIB 24 Total scale range Rated frequency, f n 10 ma-15 A 50 or 60 Hz Auxiliary voltage, EL 36, 48-55 or 110-125, 220, 250 V dc + 20% Operate time at instantaneous current change from 0 to 1,1 x set value 10-15 ms 2,5 x set value 4-6 ms Resetting ratio > 70% Resetting time at instantaneous current change to 0 from 1,1 x set value 5 ms 70 x set value 10-11 ms Consistency of operate value/setting and graduation error (% of highest setting) Percent change in operate current: at frequency change within f n ±5 Hz per C temperature change per % auxiliary voltage change Transient overreach at lowest/highest setting Permitted ambient temperature <1/<5 (<1/<10 for I s = 5 A) -2,5%/Hz < 0,15% 0,05% 10/10% at t > 10 ms -25 C to +55 C Power consumption Auxiliary voltage circuit at rated dc voltage 48/55 V 110/125 V 220/250 V Before operation 0,7/1,2 0,5/0,7 1,6/1,8 After operation 1,2/1,6 W 1,1/1,4 W 2,3/2,6 W Current circuit Overload capacity and power consumption Cont. 1 s 0,5 s I = I s Overload Power cons. A A A mva 10 ma 25 ma 50 ma 0,1 A 0,25 A 0,5 A 0,2 A 0,5 A 1 A 1 A 2,5 A 5 A 0,30 0,70 1,2 2,7 6,5 10 6,8 11 15 15 20 20 4,4 12 15 33 100 180 180 350 350 5,7 15 19 43 130 300 300 300 450 450 5 6 7 6 7 9 6 9 18 18 55 150 Insulation tests: Dielectric test, Voltage circuits to contact circuits and earth Current circuits to other circuits and earth Impulse voltage test Disturbance tests: Power frequency test Fast transient test 1 MHz burst test 2,0 kv, 50 Hz, 1 min 2,5 kv, 50 Hz, 1 min 5,0 kv, 1,2/50 ms, 0,5 J 0,5 kv, 50 Hz, 2 min 4-8 kv, 2 min 2,5 kv, 2 s 4 Current and voltage measuring relays 1MRK508018-BEN Revision: B

RXIB 24 Dimensions Weight 2U 12C modules 0,7 kg Contact data: No. of contacts Max. system voltage dc/ac Current carrying capacity (for already closed contact) 200 ms/1 s continuously Making and conducting capacity L/R 1 make 250/250 V 3/2,5 A > 10 ms, 200 ms/1 s 2/2 A Breaking capacity ac PF > 0,1 max. 250 V dc L/R < 40 ms 24/48 V 110/125 V 220/250 V 2 A 0,6 A 1/0,5 A 0,2/0,16 A 0,1/0,08 A RXEEB 1 Operate dc value, adjustable (1-12) x U S Scale factor, U S (Reconnectable) 0,1 V or 1 V Setting and graduation error (% of highest setting) < 5 Hysteresis, adjustable (the difference between operate value and reset value) Overload capacity continuously Input resistance: Input voltage < 12 V For input voltages > 12 V < 150 V Output dc voltage Permitted output current Operate time at instantaneous voltage change from 0 to: 1,3 x set value 2 x set value Auxiliary dc voltage, EL (0-1,2) x U S 150 V 180 kohm 100 kohm 24 or 48 V < 100 ma < 30 ms < 25 ms ±24 V or 48 V Permitted auxiliary voltage deviation -20% to +10% Permitted ambient temperature Power consumption auxiliary voltage circuit measuring circuit, highest/ lowest setting Percent change in operate and reset voltage: per % auxiliary voltage change 1-12 V 0,1-1,2 V per C temperature change Insulation test: Dielectric test Impulse voltage test Disturbance test: 1 MHz burst test common mode differential mode Dimensions Weight -20 C to +55 C excl. aux. relay 1,6 W 0,8 mw/0,056 mw < 0,05%/% < 0,15%/% < 0,15%/ C Not applicable 5,0 kv, 1,2/50 ms, 0,5 J 2,5 kv, 2 s 1,0 kv, 2 s 2U 6C modules 0,25 kg Current and voltage measuring relays 1MRK508018-BEN Revision: B 5

Ordering and terminal diagrams Specify for each relay; Type Quantity Ordering No. Scale range RXIK 1 Ordering No. RK 418 004-AA 13 12 11 16 15 14 I > 28 18 + 12V 12V 0 21 31 41 + I (96000147.eps) RXIB 24 Ordering No. selection table; Ordering No. RK 413 140-.. RK 413 141-.. Rated auxiliary dc voltage V (EL) 36, 48-55 V 110-125, 220, 250 V 115 114 + I > 224 225 EL 131 141 I (96000148.eps) Please note that the ordering number is completed with letters from the selection table below, depending on measuring frequency and scale range. Letter selection table Frequency Scale range (A) 0,01-0,15 0,1-1,5 0,2-3 1-15 50 Hz BB BC BD BE 60 Hz CB CC CD CE Example: A 48 V dc relay with 1-15 A setting range for 50 Hz has the ordering number RK 413 140-BE. RXEEB 1 With normally non-energized output terminal RK 427 102-AD With normally energized output terminal RK 427 102-BD Us = 0,1 V Us = 1 V ±U ±U -U Connect 18 to 28 Connect 25 to 26 Connect 25 to 24 17 27 25 24 26 18 28 U > 15 13 11 0 24V 24V+ 21 1) (96000149.eps) 1) 48V output relay 6 Current and voltage measuring relays 1MRK508018-BEN Revision: B

References References Breaker failure relay RAICA RARIC shaft current relay RXMB 1, RXMC 1 auxiliary relays RXMA 1, RXME 1, RXMM 1, RXMT 1 auxiliary relays COMBIFLEX accessories incl. power supply COMBIFLEX connection and installation components 1MRK 505 005-BEN 1MRK 502 003-BEN 1MRK 508 006-BEN 1MRK 508 015-BEN 1MRK 513 004-BEN 1MRK 513 003-BEN Current and voltage measuring relays 1MRK508018-BEN Revision: B 7

Contact us ABB AB Substation Automation Products 721 59 Västerås, Sweden Phone: +46 (0) 21 32 50 00 www.abb.com/protection-control Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. ABB AB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained herein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in part is forbidden without prior written consent of ABB AB. 1MRK508018-BEN Revision:B ABB India Limited Plot no. 4A, 5 & 6, II Phase Peenya Industrial Area Bangalore - 560 058. India Phone: +91 80 2294 9632 Facsimile: + 91 80 2294 9188 Copyright 2013 ABB. All rights reserved.