WIRE AND CABLE SECTION M WIRE AND CABLE. TEW / TEWN and TR-64 Wire. SPT1 / SPT2 / SEW1 AND SEW2 Wire. SVT / SJT / SO AND SOOW Cords

Similar documents
SECTION Q WIRE AND CABLE Wilson Avenue, Toronto, Ontario, Canada, M9M 1A1 Ph: Fax:

THHN12STGN500 THHN 12 STR Green 500

Descriptions RoHS Compatible; Applicable Standard ASTM B3, ASTM B8, ASTM B787, Federal Specification A-A-59544, NFPA 70, NEMA WC-70

THHN12S0LWHBL500 THHN 12 Sol White/Blue Striped 500

THHN2BK2500 THHN 2 STR Black 2500

THHN6WH500 THHN 6 STR White 500. Features Conductor Size Current Rating 55 AMPERE (60 DEG C), 65 AMPERE (75 DEG C), 75 AMPERE (90 DEG C)

Descriptions RoHS Compatible; Applicable Standard ASTM B3, ASTM B8, ASTM B787, Federal Specification A-A-59544, NFPA 70, NEMA WC-70

SIMpull THHN, it slips and slides - all with NoLube.

Servo Cable Selection

GROUNDING EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA

MEDIUM VOLTAGE

Power-limited Circuit Cable. Features & Applications: Specification. Power-limited Circuit Cable

Wire Gauge Chart. Cigar Lighter 10 to 12. Dome Light 1. Radio 2 to 4. Gauges 0.7 to 1. Instrument Lights 1.5 to 3

EXTRA-PREMIUM GRADE PVC JACKET FOR EXTENDED CABLE LIFE. 24 AWG (0,23mm 2 ), 7/32 (7x0,20mm), Insulation Thickness: 0.010" (0,25mm)

Airport Cables & Connectors

CIR (Crush & Impact Resistant) VFD Power Cable

WIRE&CABLE FILS&CÂBLES S I N C E

CATEGORY 5E MULTIPAIR WIRE

Caledonian. Profibus L2 Indoor BUS CABLE. Application: Construction:

Wire and Cable. 99 Wire Dual Wall 120ºC rated, Modified Polyester Low fire hazard wire and cable. Features & Benefits

ÖLFLEX. Lift & Crane Cable LIFT & CRANE CABLE


Extremely Oil-Resistant & Flexible Tray Cable with UL & CSA; Unshielded & Shielded. Complete the Installation. SKINTOP Strain Relief page 488

Switchgear Wire. Specification Table. Page <1> 31/08/10 V1.0. : Varies with colour and packing.

FLEXIBLE POWER & GROUNDING. Braid Solutions

WIRE & CABLE. 99 Wire Low fire hazard wire and cable

3-10. General Quick Selection Introduction 3-Cordsets PannelConnect Safety. Connection. Network Media

Addison. Profibus SK Indoor + Outdoor BUS CABLE. Application: Construction:

WIRE & CABLE FILS ET CÂBLES ALAMBRES Y CABLES. 63 Technical information. 64 Primary Wire. 66 Brake Cable & Portable Extension Cable

SUBMITTAL COVER SHEET

2. CONDUCTORS. 2.1 Strand Types. 2.2 Coatings Tensile Strength of Copper Wire Copper Strand Properties. 2.5 Aluminum Strand Properties

The STrongeST Link to your SucceSS... From ViSion to FiniShed ProducT

Table Of Contents. 11, 12 Thermostat Cable 39

CABLES FOR MOTION CONTINUOUS-BENDING HI-FLEX ELECTRICAL CABLES TOTALTRAX TURN-KEY SYSTEMS PRE-ASSEMBLED CABLES STRAIN RELIEF DEVICES

Electrical Characteristics Nominal electrical characteristics are shown in Table 1. Attenuation, Comply with ANSI T1.102; discrete values Table 1a.

ELECTRONIC WIRE,CABLE AND TUBING FOR THE TWENTY-FIRST CENTURY AND BEYOND

Lutze Inc. Flexible Control Cables USA Selection Guide V. 2.6

TIGER BRAND MINING CABLES

CATALOG OF PRODUCTS. Your Best Supplier of Electrical Cables

FOR INTERCONNECT AND CROSS-CONNECT APPLICATIONS

Industrial Data Solutions Industrial Data DeviceBus for ODVA DeviceNet Cables

GEXOL WORLD CLASS OIL & GAS CABLES

For tough, seaworthy wire

High Temperature Flexible Control Cable

SECTION WIRE AND CABLES. A. The CONTRACTOR shall provide wires and cable, complete and operable, in accordance with the Contract Documents.

CCW. Continuously Corrugated Welded Cable. Armored Cable for Hazardous Locations

Industrial Data Solutions Industrial Ethernet Cables Category 5e DataTuff Twisted Pair Cables Heavy Duty Sunlight- and Oil-Resistant Jackets

SPEC 44. Wire and cable

Screened servo cable with PUR outer sheath for highly dynamic power chain application - certified

ÖLFLEX 409 P. Heavy duty control cable with PUR jacket

Creating. There is one basic question every customer needs to address when creating custom

Continuous Flex Data Cable

Standard Lengths of. Code Ft. m

Wiring Techniques for Wiring a Lamp

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

Ground Clamps Cable Tray

SINGLE CORE CABLE-2491X PVC H05V-K CABLE 300/500V

Profibus-PA. Profibus-PA. Process Automation. Over-Molded Cables Receptacles Field Wireables Accessories. UL File #: E

Connection by Compression

Analog Multi-Pair Snake Cable

Detailed Specifications & Technical Data

Connection by Compression

LGH High Voltage Connectors

Welding Cables Rubber Insulated

Copper Compression Lugs Conductor Size #8

IMSA TRAFFIC SIGNAL CABLE

ÖLFLEX HEAT. Cable Solutions for Extreme Temperature

CY CONTROL FLEXIBLE PVC INSULATED / TINNED COPPER WIRE BRAID (TCWB) / PVC SHEATHED

Communication, Control, and Industrial Cable

CORFLEX VFD CORFLEX VFD Part Number: Drive Cable

MIL-C-17 Standard RF Coaxial Cable Low Loss & Ultra Low Loss RF Microwave Cable ANTENNA & TEST Cable up to 26.5 GHz

GO... with the Leader! Advanced Digital Cable is the manufacturing leader of cable for the traffic industry

FieldLink MC at 20 x outer diameter Torsion

ÖLFLEX FORTIS 55 Highly Flexible and Extremely Oil-Resistant Tray Cable; -40 C Flexible/-55 C Stationary

Product Index. 1 Copper Building Wire Products Flexiloy Aluminum Wire and Cable Products Power and Control Tray Cable Products 31 39

DeviceNet Series. Cables Cordset Accessories Receptacles Receptacle Accessories Junction Blocks

ENVIRONMENTAL. Operating Temperature: -40ºC to +130ºC. Wire Size. Code Accepted Max Wire Gauge Insulation AWG Solid or Stranded

High Temperature Flexible Control Cable OLFLEX

Over 35 Years of Service. Our Commitment. Dedicated to Our Customers. Product Expertise and Specialized Services. Strategic Partnerships

HOOK-UP WIRE A STYLE TO SUIT ANY NEED

Data sheet C6 A RJ45 field plug pro 360

Detailed Specifications & Technical Data

Data sheet C6 A RJ45 field plug pro

OLFLEX. Flexible Tray Cable MARYLAND METRICS. LAPP products are available from

CCW Continuously Corrugated Welded Cable ARMORED CABLE FOR HAZARDOUS LOCATIONS

02 WIRE AND CABLE WIRE AND CABLE FILS ET CÂBLES ALAMBRES Y CABLES. Primary Wire Dispenser

5-pole M12 connector. Connecting cable: cab-m12/5-g-2m. LED (red) for dirt accumulation indication

AEE. Canada. Australia

Multi-Paired Cable Product Finder

Thermocouple & Extension Wire

DLO Flexible Power Cable

Micro-Change. Cordset Family

Discrete. Coaxial. Composite. Digital. Page 1. Page 14. Page 18. Page 43

USB 2.0-IP67 Water Resistant Connector System

GameChanger Cable. Unshielded Twisted Pair Riser Rated - CMR PRYWB (legacy part no)

Product Description Color

LV AIRGUARD. P r o ble m. ife? No S. a proven, rugged product for harsh environments

CP CABLE. SPECIFICATIONS: 1. CONDUCTOR: Bare, soft drawn copper, Class B stranding per ASTM B INSULATION: High molecular weight polyethylene.

File E13288 Vol. 1 Sec. 24 Page 1 Issued: Vol. 22 Sec. 2 Revised: and Report

Install & Go Cat.8 S/FTP Trunk Cable Assembly Description

Transcription:

SECTION M TEW / TEWN and TR-64 Wire SPT / SPT2 / SEW AND SEW2 Wire SVT / SJT / SO AND SOOW Cords Clear Braided Multi Conductor Cable M2 M3 M4 M5

M2 TEW / TEWN AND TR-64 WIRE TEW and TEWN - Single Conductor Hook up wire for internal wiring of appliances and lighting fixtures PART NO. TEW-8/6 BC TEW-6/26-BC TEW-4/4-BC TEWN-8/6 BC AWG Size 8 6 4 8 Conductor Stranding 6 26 4 Voltage 600V 600V 600V 600V Temperature Rating 05 C / -20 F 05 C / -20 F 05 C / -20 F 05 C / -20 F Nom. Insulation Thickness (in.) 0.030 0.030 0.030 0.05 Nom. O.D of Wire (in.) 0.0 0.20 0.36 0.082 Colors see below see below see below see below Approx LBS/MFT 9 lbs 2 3 lbs 2 9 lbs 2 7 lbs 2 Ampacity 0 3 5 0 UL Approved Approved Approved Approved CSA Approved Approved Approved Approved Conductor Material Bare Copper Bare Copper Bare Copper Bare Copper Insulation Material PVC PVC PVC PVC & Nylon Available Colors - add Suffix to Part Number - BLK - Black - WHT- White - GRN - Green - BLU - Blue - YEL - Yellow - RED - Red - BRN - Brown - PUR - Purple - GRY - Grey - ORG - Orange Available Spools - add Suffix to Part Number - S75-75 meter spool -S300-300 meter spool TR-64 AND CLEAR GROUND WIRE - Single Conductor Hook up wire for internal wiring of appliances and lighting fixtures PART NO. TR64-8/6-TC GOLD-GRND 8/6-BC-GRN-STR SIL-GRND 8/6-TC-GRN-STR AWG Size 8 8 8 Conductor Stranding 6 6 6 Voltage 300V - - Temperature Rating 90 C - - Nom. Insulation Thickness (in.) 0.5 0.5 0.5 Nom. O.D of Wire (in.) 0.078 0.078 0.078 Colors see below Gold / Green Tracer Silver / Green Tracer Approx LBS/MFT 8 lbs 2 8 lbs 2 8 lbs 2 Ampacity 0 0 0 UL Approved - - CSA Approved - - Conductor Material Tinned Copper Bare Copper Tinned Copper Insulation Material PVC PVC PVC Available Colors - add Suffix to Part Number - BLK - Black - WHT- White - GRN - Green - BLU - Blue - YEL - Yellow - RED - Red - BRN - Brown - PUR - Purple - GRY - Grey - ORG - Orange FOR MORE INFORMATION PLEASE CALL -800-66-960 (HEAD OFFICE) -888-762-5384 (USA)

SEW / SEW2 / SPT AND SPT2 WIRES M3 SF / SEW Wire - Single Conductor SEW wire is used for internal wiring of lighting fixtures, motors or appliances where a higher temperature rated wire (200ºC) is needed. PART NO. SF- / SEW-8/7 SF-2 / SEW2-8/7 SF-2 / SEW2-6/7 SF-2 / SEW2-4/7 AWG Size 8 8 6 4 Conductor Stranding 7 7 7 7 Voltage 300V 600V 600V 600V Temperature Rating 200C 200C 200C 200C Nom. Insulation Thickness (in.) 0.05 0.030 0.030 0.030 Nom. O.D of Wire (in.) 0.095 0.23 0.34 0.48 Colors see below see below see below see below Approx LBS/MFT 8 lbs 2 lbs 2 5 lbs 2 2 lbs 2 Ampacity 6 6 8 7 UL Approved Approved Approved Approved CSA Approved Approved Approved Approved Conductor Material Tinned Copper Tinned Copper Tinned Copper Tinned Copper Insulation Material Silicone Rubber / Glass Braid Silicone Rubber / Glass Braid Silicone Rubber / Glass Braid Silicone Rubber / Glass Braid Available Colors - add Suffix to Part Number - BLK - Black - WHT - White - RED - Red - GRN- Green SPT- and SPT-2 Cord Lamp Cord is intended to be used in household appliances, including lamps, radios and fans. PART NO. SPT-8/2-4BC SPT2-8/2-4BC AWG Size 8 8 No. of Conductors 2 2 Conductor Stranding 4 4 Voltage 300V 600V Temperature Rating 05 C 05 C Nom. Insulation Thickness (in.) 0.030 0.045 Nom. O.D of Wire (in.) 0.0 X 0.25 0.40 X 0.360 Colors see below see below Approx LBS/MFT 7 lbs 2 33 lbs 2 Ampacity 0 0 UL Approved Approved CSA Approved Approved Conductor Material Bare Copper / Tinned for Silver Bare Copper / Tinned for Silver Insulation Material PVC PVC Available Colors - add Suffix to Part Number - BLK - Black -WHT - White - GLD - Gold - SIL- Silver - BRN - Brown FOR MORE INFORMATION PLEASE CALL -800-66-960 (HEAD OFFICE) -888-762-5384 (USA)

M4 SVT / SJT / SO AND SOW CORDS SVT and SJT Cord SJT CORD: SJT cord is designed for heavy power tools, equipment, portable lighting, power bars. SVT CORD: Vacuum Cleaner Cord is intended for use on household appliances, lamps, floor care appliances, radios and fans. PART NO. SJT-8/2-05C SVT-8/3-05C SJT-8/3-05C SJT-6/3-05C SJT-4/3-05C AWG Size 8 8 8 6 4 No. of Conductor 2 3 3 3 3 Conductor Stranding 6 4 6 26 4 Voltage 300V 300V 300V 300V 300V Temperature Rating 05 C 05 C 05 C 05 C 05 C Nom. Insulation / Jacket Thickness (in.) 0.030 / 0.030 0.05 / 0.030 0.030 / 0.030 0.030 / 0.030 0.030 / 0.030 Nom. O.D of Wire (in.) 0.290 0.255 0.305 0.330 0.365 Colors see below see below see below see below see below Approx LBS/MFT 40 lbs 2 38 lbs 2 52 lbs 2 65 lbs 2 85 lbs 2 Ampacity 0 0 0 3 8 UL Approved Approved Approved Approved Approved CSA Approved Approved Approved Approved Approved Conductor Material Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Insulation Material PVC PVC PVC PVC PVC Jacket Material PVC PVC PVC PVC PVC Available Colors - add Suffix to Part Number - BLK - Black - WHT - White SO and SOOW Cord SO and SOOW Cord is intended for power tools power equipment, small motors, portable appliances and machinery. The rubber or EPR insulation feature excellent resistance to oil and moisture and offers high flexibility for indoor and outdoor use. PART NO. SO-8/3-90C SO-6/3-90C SOOW-8/3-90C SOOW-6/3-90C SOOW-4/3-90C AWG Size 8 6 8 6 4 No. of Conductor 3 3 3 3 3 Conductor Stranding 6 26 6 26 4 Voltage 600V 600V 600V 600V 600V Temperature Rating 90 C 90 C 90 C 90 C 90 C Nom. Insulation / Jacket Thickness (in.) 0.030 / 0.060 0.030 / 0.060 0.030 / 0.060 0.030 / 0.060 0.045 / 0.080 Nom. O.D of Wire (in.) 0.365 0.390 0.365 0.390 0.560 Colors see below see below see below see below see below Approx LBS/MFT 83 lbs 2 07 lbs 2 80 lbs 2 95 lbs 2 70 lbs 2 Ampacity 0 3 0 3 8 UL Approved Approved Approved Approved Approved CSA Approved Approved Approved Approved Approved Conductor Material Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Insulation Material Rubber or EPR Rubber or EPR Rubber or EPR Rubber or EPR Rubber or EPR Jacket Material Rubber or EPR Rubber or EPR Rubber or EPR Rubber or EPR Rubber or EPR Available Colors - add Suffix to Part Number - BLK - Black FOR MORE INFORMATION PLEASE CALL -800-66-960 (HEAD OFFICE) -888-762-5384 (USA)

CLEAR BRAIDED MULTI CONDUCTOR CABLE M5 Clear Braided Multi Conductor Cable Clear Braided Cable is intended for power feed on commercial and residential fixtures which are suspended from above using aircraft suspension cables. The clear insulation and braid offer a matching esthetic look to the cables. PART NO. PC-8/3-BRAID-STR-300V PC-8/3-BRAID-STR-600V PC-8/4-BRAID-STR-300V PC-8/4-BRAID-STR-600V AWG Size 8 8 8 8 No. of Conductor 3 3 4 4 Conductor Stranding 6 6 6 6 Voltage 300V 600V 300V 600V Temperature Rating 05 C 05 C 05 C 05 C Nom. Insulation Thickness (in.) 0.030 0.030 0.030 0.030 Nom. O.D of Wire (in.) 0.245 0.285 0.265 0.280 Colors Clear Clear Clear Clear Approx LBS/MFT 53 lbs 2 57 lbs 2 52 lbs 2 57 lbs 2 Ampacity 0 0 0 0 UL Approved Approved Approved Approved CSA Approved Approved Approved Approved Conductor Material Bare Copper Bare Copper Bare Copper Bare Copper Braid Material Tinned Copper Tinned Copper Tinned Copper Tinned Copper Insulation Material PVC PVC PVC PVC Jacket Material PVC PVC PVC PVC Available Spools - add Suffix to Part Number - S300-300 meter spool PART NO. PC-8/4-BRAID-SOL-600V PC-8/5-BRAID-STR-600V PC-8/5-BRAID-SOL-600V AWG Size 8 8 8 No. of Conductor 4 5 5 Conductor Stranding 6 Voltage 600V 600V 600V Temperature Rating 05 C 05 C 05 C Nom. Insulation Thickness (in.) 0.030 0.030 0.030 Nom. O.D of Wire (in.) 0.280 0.30 0.30 Colors Clear Clear Clear Approx LBS/MFT 58 lbs 2 65 lbs 2 65 lbs 2 Ampacity 0 0 0 UL Approved Approved Approved CSA Approved Approved Approved Conductor Material Bare Copper Bare Copper Bare Copper Braid Material Tinned Copper Tinned Copper Tinned Copper Insulation Material PVC PVC PVC Jacket Material PVC PVC PVC Available Spools - add Suffix to Part Number - S300-300 meter spool FOR MORE INFORMATION PLEASE CALL -800-66-960 (HEAD OFFICE) -888-762-5384 (USA)

FOR CUSTOM ORDERS CONSULT FACTORY