The all-new Raptor tank gauging system Always ready for your next challenge safety EFFICIENCY ACCURACY
Welcome to a new era in tank gauging Big words, we know. But Raptor really takes tank gauging to another level. You will be better equipped to handle the ever-increasing demands on efficiency, safety and accuracy. Raptor is a complete and flexible tank gauging system, giving you total freedom. Ready to improve efficiency The Raptor system is based on the open industry standard Fo u n d at i o n fieldbus. This makes it easy to install exactly the devices you need today as well as adding or replacing units tomorrow. Having access to reliable and accurate tank content information in real time is key to high plant efficiency, as your operators can handle even more tanks, fill the tanks higher and better utilize the storage capacity. Raptor takes you to top efficiency and lets you stay there. Ready to improve safety With no moving parts, radar technology is fundamentally reliable. But Raptor takes safety further than ever before. The gauge with a 2-in-1 feature can, for example, be delivered to meet SIL 3 requirements for overfill prevention. Ready to improve accuracy For decades, Rosemount Tank Radar gauges have been the obvious choice when precision is critical. Raptor builds upon this legacy by offering level measurement accuracy of ±0.5 mm (0.02 in.). But even if accuracy is important, the need can vary. That is why Raptor includes gauging solutions all the way from operational control to custody transfer performance with full inventory management functionality. Radar Level Gauge Non-contact radar gauge for applications with high requirements on level measurement and overfill prevention. Smart Wireless Gateway Connects wireless devices on the tanks with the host system. TankMaster Tank gauging software for inventory and custody transfer functions. Calculations can be based on API, ISO and other major industry standards.
Future-proof design New level of safety Renowned accuracy
Whatever your next step, Raptor will be ready with LPG/LNG antenna Pressurized or cryogenic liquefied gas Strong echo even under surface boiling conditions There are always new challenges to face in distance communication to the control a tank storage facility. Expansion or refurbishing projects mean you have to connect other major fieldbus standards. Wireless room can be made via our TRL2 fieldbus or new equipment to your installation. This is data transmission is also an option. This is also the case when you replace damaged especially valuable when it is necessary or outdated technology. Raptor lets you to cross roads or when distance or ground meet your challenges so you can maintain conditions make cabling expensive. high plant efficiency and protect the value of your tank gauging investment. Upgrade gradually There are numerous tank farms with gauging Practically unlimited based on older technology, even in fairly Thanks to the use of an open communications recent installations. But don t worry. Raptor standard (Foundation fieldbus), Raptor lets can emulate gauges from other manufacturers. This means you can add Raptor units you combine gauging devices freely within your system. The bus-powered, two-wired to your existing system. Tankbus is self-configured and intrinsically safe allowing cabling without conduits Open and scalable which means lower installation cost. Long- Two-wire bus or wireless Emulation capabilities The precision instruments of tank gauging with horn antenna Fixed roof tanks without still-pipe 200 400 mm (8-16 in.) nozzles Oil products and chemicals except for sticky liquids with parabolic antenna Best choice in tanks without still-pipe Demanding environments with sticky or condensing liquids such as asphalt with still-pipe array antenna New or existing still-pipes Crude oil tanks with floating roofs Gasoline tanks with/without inner floating roofs
Smart Wireless Gateway 2230 Alternative Connection to DCS 5400 2240S 3051S 2160/65/75 Field Communication Unit Tank Hub 2240S Multi 5400T Radar Level Gauge Input 644 2240S 2230 Graphical Radar Level Gauges Field Display To DCS THUM 644 with Spot 2180 Field Bus Modem 2240S Multi 5300 Tank Hub Input 5300T Radar Smart Level Gauges Wireless 5400T Radar 644 with SpotTHUM Level Gauge 644 3051S 644 3051S Pressure 2230 Graphical Average 5400/5300 Field Display Sensor Alternative WLS Water 2230 Level Sensor 5300T Connection Radar to DCS Level Gauges Smart Wireless THUM www Average Sensor Radar Level Gauges Tank Hub TankMaster PC Workstation in Network 3051S Pressure TankMaster.net for web access WLS Water Level Sensor 2240S MultiInput 5400 Radar Level Field Communicator 1 5300 Guided Wave Radar 2230 Graphical Field Display 2120 Liquid Level Switch 565 Multiple Spot 765 Multiple Spot with Sensor Water Level Sensor 3051S Pressure 2 4 3 5 7. 6 8 0 644 with Spot 9 - Smart Wireless THUM
Taking safety to a higher level Lawmakers, corporate management, members of the community demands for increased safety come from just about everywhere. Raptor allows you to meet existing and future requirements and protect plant assets, the environment and human lives. World s first high precision SIL 3 radar In addition to measuring level, a Radar Level Gauge can be used for overfill and dry-run prevention. Together with other radar devices and switches (see examples below) and tank hubs you can achieve SIL 2/SIL 3 certified level alarm functionality. The is also available with two independent radar gauges in one housing (2-in-1) enabling SIL 3. Radar never sleeps The Raptor radar level gauges are always in operation. This is not the case with passive devices like traditional switches, where you can only be sure they are working at the very instant you run a test. With two separate gauges, you can compare the results and immediately spot if one gauge is not working. Wide range of overfill prevention options Unique 2-in-1 feature SIL 2 and SIL 3 safety Continuous surveillance + (2-in-1) + 5300/5400 + 2120 Dual radar gauges for level and overfill measurements. SIL 2 certified with the possibility to achieve SIL 3 safety level. Two radar gauges in one housing independent level and overfill measurements. SIL 2 and SIL 3 safety. Radar level gauge and radar level transmitter independent level and continuous high-level alarm. Suitable for SIL 2 safety. Radar level gauge and point level switch. Suitable for SIL 2 safety.
When every drop counts, you can count on radar technology Thanks to Raptor s measurement accuracy, you get precise data for custody transfer, inventory management, and loss control. The level measurement accuracy of ±0.5 mm (0.02 in.), together with the highest precision average tem perature measurement, ensures exact net volume calculations. In cases where medium accuracy is sufficient, we offer a number of cost-effective gauging instruments. Works everywhere The Raptor system suits all kinds of applications and tanks: pressurized and non-pressurized, with fixed or floating roofs, with or without still-pipes. This makes Raptor the perfect choice for refineries, tank terminals, fuel depots, LNG plants and more. More accurate billing, better tank utilization and higher safety are some of the benefits. No moving parts also make the gauges reliable, virtually maintenance-free and long lasting. Simply put, the money you invest in Raptor is soon paid back and turned into years of profits. Accuracy of ±0.5 mm (0.02 in.) Precise net volume calculations All tank storage applications The best there is With Raptor you enjoy precise tank gauging. The pioneer in radar-based tank gauging We invented radar tank gauging, delivered our first radar level gauge in 1975 and have since then delivered over 100 000 units all over the world more than anyone else. Rosemount Tank Gauging representatives are located worldwide, providing you with service and support from highly trained service engineers in more than 80 countries.... for marine tankers (1975) World market leader Proven performance Always close at hand We introduced the world s first radar level gauge with 2-in-1 and 3-in-1 (2002) for on-shore tanks with custody transfer accuracy (1984) with SIL 2 certification (2007) with wireless communications (2009) with 2-in-1 and SIL 3 safety (2010)
Rosemount is a registered trademark of Rosemount Inc. Fo u n d a t i o n is a trademark of the Fieldbus Foundation. The Emerson logo is a trademark and servicemark of Emerson Electric Co. The contents of this publication are presented for information purposes only, and while efforts have been made to ensure their accuracy, they are not to be construed as warranties or guarantees, expressed or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice. Rosemount Tank Radar AB accepts no responsibility for any errors that may appear in this publication. Emerson Process Management Rosemount Tank Gauging Box 13045 SE-402 51 Gothenburg SWEDEN Phone: +46 31 337 00 00 Fax: +46 31 25 30 22 E-mail: sales.rtg@emerson.com www.rosemount-tg.com North America: Rosemount Tank Gauging North America Inc. Houston, Texas. Tel: 800-722-2865. E-mail: sales.srt.hou@emerson.com MIDDLE EAST: Rosemount Tank Gauging Middle East SPC, Bahrain. Tel: +973 17 22 66 10. E-mail: rtgme.sales@emerson.com INDIA: Rosemount Tank Gauging India Pvt. Ltd., Pune. Tel: +91 20 67211500. E-mail: pune@tankradar.co.in ASIA PACIFIC HEADQUARTERS: Emerson Process Management Asia Pacific Pte Ltd, Singapore. Tel +65 6777 8211. E-mail: specialist-itg.rmt-ap@ap.emersonprocess.com OTHER COUNTRIES: Find your local representative at www.rosemount-tg.com Rosemount Tank Radar AB. Ref.No. 207020en, Rev AA, August 2010