L = 30 mm L = 150 mm T 90

Similar documents
Temperature Sensors and accuracy Types and Fields of Application. Sheathed sensors Accessories for Sheathed sensors 07.

The Right Temperature Sensor For Any Measuring Task Types and Fields of Application 07.04

Temperature measuring instrument (3-channel)

Temperature measuring instrument (1-channel)

Temperature measuring instrument (2-channel)

Temperature measuring instrument (1-channel)

Temperature measuring instrument (2-channel)

Temperature measuring instrument (2-channel)

TEMPERATURE PROBE. Temperature probe. Handheld instrument. Display / Controller. Logger / EASYBus. Transmitter. Application: NiCr-Ni (Type K)

Precision Thermistor Sensors

Humidity/temperature measuring instrument

Humidity/temperature measuring instrument

testo 735, highly accurate alarm and logger thermometer with measurement site management

Fluke 712B and 714B Temperature Calibrators

Temperature and Humidity Probes. Code Max Temp ( C) Resistance 25 C) Accuracy 0 to 70 C)

n Measurable displacements between n Linearity: max. ± 0.05 % n Housing diameter 12.9 mm n Service life: 10 8 movements

Humidity/temperature measuring instrument

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

Mineral-insulated resistance thermometers to EN

Resistance thermometer Model TR31, miniature design

Resistance Thermometers Model Series TR7X0, Sheathed Design

SureGrip TM. XWWarning

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Torque Sensor Accessories and Services

Senturion XPR04 Proximity Probe

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Versatility for Ventilation and Indoor Air Quality

Digital conductivity transmitter

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

Multi-function measuring instrument

The electronic anti-scale system

Instructions for Preparing OPTICAL GROUND WIRE IN AN ISOLATOR

ENVIRONMENTAL. Operating Temperature: -40ºC to +130ºC. Wire Size. Code Accepted Max Wire Gauge Insulation AWG Solid or Stranded

P R o D u c T I n F o R m at I o n. TDR Level Sensor LFP. The clean solution

Temperature. Characteristics. Applications

Additel 875 Series Dry Well Calibrators

Valve Island with Electronic I/O

STANDARD RTD's INDEX

Digital inductive conductivity transmitter

Pre-Calibrated Models

Ultra Precise Immersion RTD Sensors

Temperature. Characteristics. System Temperature probes. Temperature probes with integrated transmitter. Temperature probes with data logger

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Data Sheet for Angle Sensors

uk.rs-online.com (UK) (International)

SECTION COMMON WORK RESULTS FOR HVAC

Magnetic-Inductive flow Meter fmi

Temperature Sensors. Installation Note. McLaren Electronic Systems McLaren Technology Centre Chertsey Road Woking Surrey GU21 4YH UK

All-round Talent for Ventilation and Room Air Quality

Datasheet Platinum Resistance Pt100 In-head (Push Button) Temperature Transmitter TX203P mA output, default range supplied C

MIL-C-17 Standard RF Coaxial Cable Low Loss & Ultra Low Loss RF Microwave Cable ANTENNA & TEST Cable up to 26.5 GHz

ASSEMBLY INSTRUCTION CONTENT

The transducer component converts the measured signal and displays the actual value.

Technical Information Smartec CLD18

Conductivity sensor for hygienic applications

ELECTRICAL VARIABLES How Split-Core Type Transformers Work. How Optical Probes for Current Meters Work. Current Meter Scanning à la ALMEMO

Multi-function measuring instrument

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC

ASC IMU 7.X.Y. Inertial Measurement Unit (IMU) Description.

Temperature Sensors for Laboratory and Portable Meters

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Technical Information Condumax CLS21D/CLS21

Insertion Thermocouples with Bayonet Lock

NEUROLOGIC RESEARCH CORPORATION

FULL RANGE OF FASTENERS

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

Screw-in resistance thermometers with plug connector

XXXX e. X d.. X X X a

ph or ORP Transmitter

Catalog of CLA force and torque sensors

Fiber Optic Cables Plastic Fiber Optic Cables Glass Fiber Optic Cables

Folding thermometer. We measure it. testo 103 The smallest folding thermometer in its class. Ideally suited for applications in the food sector

Condumax W CLS15 and CLS15D

SILICon IrrADIAnCe SenSor

Precision and High Reliability Thermostats Issue 3. Datasheet. Table of Contents

Indumax CLS50/CLS50D. Technical Information

Temperature Sensor TF-CX. Operating Instructions Melt Temperature Sensor TF-CX. Contents: 2. Identification data

Temperature measuring instrument (1-channel)

METRAClip85 and 86 Clamp Multimeters

Millikelvin Thermometers MKT 10 MKT 50

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

Resistance thermometer Model TR30, compact design

3 Shielded Compact Ribbon (SCR) Wiremount Plug, XX, and Shell Kit, F200-XXX

Miniature resistance thermometer Model TR33, thread-mounted

Thermocouple & Extension Wire

Rod probe With coaxial tube reference probe

Technical Information Condumax CLS15D/CLS15

THE TOOLS RECOMMENDED Phillips Screwdriver Stripper/Crimper Electrician Pliers ½ open end wrench or ratchet wrench with ½ deep socket Utility knife

Flow Meter FC100. Description FC100. Ordering information

Configure-to-Order probes

Condumax CLS15 and CLS15D

mv/v Output MELT PRESSURE TRANSMITTERS I3 SERIES TECHNICAL SPECIFICATIONS

N series General Stationary Surface Probes

9.1 Plastic Fiber Optic Cables. 9.2 Glass Fiber Optic Cables. Volume 8 Sensing Solutions CA E August

Sensors for Vibration, Acceleration, and Shock Measurement. Product Catalog

Series 7777 Meredian II Electrode In-Line or Immersion Mounting

OEM pressure transmitter For mobile working machines Model MH-3

Paddle wheel flow controller for On/Off control

9.2. Fiber Optic Cables.

Measuring and Controlling Unit Multronic OC

Transcription:

NiCr-Ni sensor with handle FTA 120x Silver rivet, level, spring-loaded, Handle: * 138 mm and immersion measurement L = 30 mm L = 150 mm Order no. FTA1201 Order no. FTA1202 NiCr-Ni sensor with handle FTA 122 LxxxxH Silver rivet, level, not electr. isolated and immersion measurement L = 50 mm L = 200 mm Order no. FTA122L0050H Order no. FTA122L0100H Order no. FTA122L0200H NiCr-Ni sensor with handle FTA 121 LxxxxH Silver rivet, level, angled, and immersion measurement L = approx. 50 mm L = approx. 200 mm Order no. FTA121L0050H Order no. FTA121L0200H NiCr-Ni sensor with handle FTA 150 LxxxxH Measuring tip: Operative range -200...+800 C Stainless-steel rivet, level, electrically isolated and immersion measurement L = 350 mm Order no. FTA150L0350H L = 700 mm Order no. FTA150L0700H L = 1250 mm Order no. FTA150L1250H 07.11

NiCr-Ni sensor FTA 109 P NiCr-Ni sensor FTA 104 P Measuring head approx. 15 mm diameter : * 1 s L = approx. 180 mm Sensor with handle Order no. FTA109P Order no. FTA109PH Measuring head approx. 15 mm diameter : * 1 s 07/2017 We reserve the right to make technical changes. L = approx. 180 mm, with 90 angle, approx. 50 mm Sensor with handle Order no. FTA104P Order no. FTA104PH NiCr-Ni sensor with handle FTA 153 LxxxxH Measuring tip: Operative range -200...+250 C Thermal ribbon, crossed, Order no. FTA153L0100H NiCr-Ni sensor with handle FTA 1535 LxxxxH Measuring tip: Operative range -200...+250 C Order no. FTA1535L0100H 07.12

NiCr-Ni sensor with handle FTA 420 LxxxxH Silver disc, spring-loaded, on level surfaces L = 150 mm Order no. FTA420L0150H NiCr-Ni sensor FTA 025 P Measuring tip: Operative range -50...+300 C Fastened by magnet Cable: approx. 2 m PVC Magnet sensor Order no. FTA025P Magnet sensor for surface measurement Klettband: approx. 400 mm, for pipe diameter appr. 10 to 75 mm Operating range: -10... +110 C mounted on sensor tip Magnet sensor with Velcro fastener e.g. for pipework Magnet sensor, including Velcro fastener Order no. FTA025PKB 07.13

NiCr-Ni sensor FTA 131 Magnet sensor NiCr-Ni sensor FTA 026 P Measuring tip: Operative range -50...+100 C Silver rivet, level, spring-loaded, Fastened by magnet Cable: 3 m FEP/silicone Magnet sensor Order no. FTA131 Measuring tip: Operative range -50...+300 C Thermal ribbon, Cable: approx. 0.9 m line, fabric insulation Ribbon sensor Order no. FTA026P NiCr-Ni sensor FTA 8068 Measuring tip: Operative range -50...+120 C Fastened by pipe clamp (spring-loaded) Pipe diameter: 12...25 mm Cable: 1.2 m PVC on pipes Pipe clamp sensor Order no. FTA8068 07.14

NiCr-Ni film thermocouple FTA 683 Measuring tip: Operative range -100 to +200 C Folie, Insulation Kresol with permanently connected FEP / silicone thermal line (stranded wire)** -50 to +200 C, 2 meters, with ALMEMO connector Order no. FTA683 Measuring element without cable, free ends (for your own sensors) Order no. FT0683 NiCr-Ni sensor FTA 390 x Measuring tip: Thermowire, welded, Wire: 1.5 m Insulation, glass fiber, Operative range -25...+400 C Insulation FEP, Operative range -200...+205 C Order no. FTA3900 Order no. FTA39010 Digital infra-red sensor for measuring surface temperature FIAD43 Operative range: -40...600 C, Miniature probe head, with cable and ALMEMO D6 plug and 1 mounting nut Cable length = 1 m Cable length = 3 m For technical data, see page 07.34 Order no. FIAD4332 Order no. FIAD4332L3 DAkkS or factory calibration KI9xxx temperature for digital sensor (see chapter Calibration certificates) Compact infra-red probe head FIA844 Factory calibration KI9xxx temperature for sensor (see chapter Calibration certificates) Operative range: -20...500 C, Probe head, with cable and ALMEMO plug and 2 mounting nuts Cable length = 1 m Cable length = 3 m For technical data, see page 07.36 Order no. FIA844 Order no. FIA844L3 07.15