Excel 800 / Excel Web II CABLE SPECIFICATIONS

Similar documents
W7070A2000 ZAPP WIRELESS RECEIVER

ECB-103 BACnet B-ASC 10-Point Programmable Controllers

EY-EM 527: Remote I/O module, ecolink527

EY-EM 522, 523: Remote I/O module, ecolink522, 523

DO NOT USE UNIT POWER

A local 3.5 mm network jack allows a convenient way to connect an installation or diagnostic tool to the network without disconnecting any wires.

Supercal 531 Multi function Integrator that lives up to Your highest expectations

BAS Integration Manual

B850 Boiler House Energy Monitor

B850 Boiler House Energy Monitor

269 Troubleshooting Guide 11/4/98 1

Excel 15 S7760A COMMAND DISPLAY

MNL-5Rxx. Application. Model Chart. TAC I/A Series MicroNet MN 50 Controller Installation Instructions

M7061 ROTARY VALVE ACTUATORS

Power connections, minimum and maximum wiring capabilities, tightening torque

Modbus communication module for TCX2: AEX-MOD

2.7. IT system floor-standing distribution cabinet Series -IPS-F/EDS

Excel 10 W7761A Remote Input/Output Device

ISOMETER IRDH575. Approvals

DATA SHEET. CIO multi-inputs. CAN bus-based I/O module

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

PEM353. Universal measuring device

Contents. Warranty and Disclaimer 2 Introduction 3

Applications: Power generation, Cogeneration, Stationary power Large engines

Rexroth Frequency Converter Fe 0.75 kw to 7.5 kw / 400 VAC

For information transmission at dry and moist production sites, in and under plaster, outdoors for fixed installation.

UniStream Uni-I/O Modules

NX Series Inverters. HVAC Pocket Programming Guide

NetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00

r ADDENDUM FOR REAR-OF-BOARD VERSION LFS - R

Data Acquisition Modules/ Distributed IO Modules

HITEK POWER XR KW X-RAY POWER SUPPLY MODULE

Temperature Controller model MFC-301/T-Dry. Version for Dry Transformers and Motors. Technical Manual. Licht

NI REM Remote I/O Overview DATASHEET. Temperature Input Module for Remote I/O

Excel 10 W7751B,D,F VAV Controllers

2017 Advanced Energy Industries, Inc. HITEK POWER MV2000 SERIES MEDIUM-VOLTAGE HIGH-CURRENT POWER SUPPLIES

TD_485 Transceiver Modules Application Guide 2017

NI 2865A 0.3 A Matrix Cards for NI SwitchBlock

This data sheet is only valid in association with the IL SYS INST UM E user manual.

POINTAX 6000L2 Point Recorder

DIGEM f 96 x 48 EK. Applications. Description

S200 I/O System Units

Contents. Warranty and Disclaimer 2

Programming restrictions when operating SM 331; AI 8 x RTD with PROFIBUS masters which only support DPV0.

Isolated RTD Modules Product Specifications and Installation Data

Introduction. Protocol Definitions. The RS-485 Standard. APPLICATION NOTE 3884 How Far and How Fast Can You Go with RS-485?

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9853E 2-Port, High-Speed CAN Module

CCE Image may differ from the actual product By Martin Labbé, eng., Jasmin Goupil & Louis Perreault

MINI 048 / JUN 2003 PAGE 1. Temperature I/O Module HE500OCS048 / HE500OCS078 HE500RCS078

Guidelines for Wiring and Commissioning of the Hardware Service Tool STL

Installation Instructions for the SNDJ-CNT-G01/SNDJ-CNT-G02 Frequency Measurement and Switching Instruments ISSUE WARNING

FP-RTD-122. Features OPERATING INSTRUCTIONS. 8-Channel, 3-Wire RTD and Resistance Input Module

EMU Electronic AG. Jöchlerweg 4 CH-6340 Baar Switzerland Telefon +41 (0) Fax +41 (0)

FCU-503 FAN COIL CONTROLLER WITH RDU-TOUCH INTERFACE

Zentralbaugruppen CPU 222

HITEK POWER XR KW X-RAY POWER SUPPLY MODULE

Installation guide 971 SmartRadar LTi

Highlights Very compact EtherCAT I/O system in IP 20 for plug-in into a circuit board (signal distribution board)

S0 pulse counter. with S-Bus interface. Main features: Order number. Technical Data. Mounting

General Specifications

EP-5111, EP-5112, EP-5212, EP-5261, EP-5311, EP-5422, EP-5442

FM 355 CONTROLLER MODULE

INPUT RESISTANCE OR CLAMP VOLTAGE. 2 Years 23 C ±5 Voltage mv 3 10 nv > 10 G

ECL-VAV-N. Features & Benefits

UniStream Built-in. Technical Specifications US7-B5-RA28, US7-B10-RA28 US7-B5-TA30, US7-B10-TA30

OPERATING MANUAL SERIES R B F 400 VAC BRUSHLESS RACK SYSTEM

Fast Buffer LH0033 / LH0033C. CALOGIC LLC, 237 Whitney Place, Fremont, California 94539, Telephone: , FAX:

Instruction Manual TABLE OF CONTENTS 1 PRINCIPLE OF OPERATION Limitations INSTALLATION Mains connection...

OPERATING MANUAL SERIES R B F BRUSHLESS RACK SYSTEM

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide

USB-2404-UI Specifications

UniStream 5" Technical Specifications US5-B5-RA28, US5-B10-RA28

Liquid Level Sensors. M-Series Magnetostrictive Sensors

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

UL CONDITIONS OF ACCEPTABILITY

24V dc Analog Block I/O Module

SIMATIC. ET 200S distributed I/O 2AI U HF analog electronic module (6ES7134-4LB02-0AB0) Preface. Properties 1. Parameters 2.

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY

CONTA-ELECTRONICS. Converter Units

General Specifications

Product Information: ExTR Reference No. GB.FME.ExTR

1 Introduction. 1.1 General installation information

Efficiency higher than 85% Power Factor >92% Case TC* Protection Storage Humidity

RAD-IN/OUT-8D. Digital extension modules for the bidirectional wireless system. INTERFACE Data sheet _en_05. 1 Description

KNC-PLC-K506 Series FEATURES DESCRIPTION FEATURES

Passive Current Transducers for Sinusoidal Alternate Currents From A/0...5 A MCR-SLP-1/5-UI-0(-SW)

INTELLIGENT DIGITAL MULTI POWER METER [DIC-MPM]

National Instruments Switches

Position Indicator model MFC-300/IP. Technical Manual. Licht

EC centrifugal fan - RadiCal

Fault indicator. Application. SPEF 3A2 C 1MRS MBG Issued: April 1999 Status: Updated Version: B/ Data subject to change without notice

2601 System SourceMeter 2602 Multi-Channel I-V Test Solutions

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide

Schlöder GmbH - EMC Test and Measurement Systems Model #

Hardware Manual. PCD3.F240/PCD2.F2400 LON interface module for TP/FT-10 channel. Hardware Manual PCD3.F240/PCD2.F2400, LON interface module

RS-485 HUB GT for Profibus, Sinec L2, Bitbus, etc. Article No S-485-HUBGT-230-xx-x. Operation and Installation Manual

Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0

FRnet Remote I/O Modules

Transcription:

HONEYWELL EXCEL 5000 OPEN SYSTEM Excel 800 / Excel Web II CABLE SPECIFICATIONS PRODUCT INFORMATION U.S. Registered Trademark Copyright 2014 Honeywell Inc. All Rights Reserved EN0B-0689GE51 R0114

Excel 800 I/O module signal type signal level low-impedance passive sensor type of connected device, e.g. min. no. of wires min. crosssection cable spec. max. cable length at min. cross-section note 10 VDC RTD 24.9 kohm sensor resistance PT1000-1 PT1000-2 PT3000 BALCO500 NI1000TK5000 Slow binary input 2 0,5 mm² 400 m shielded GND high-impedance passive sensor Analog Input XF821A, XF821AU XFL821A, XFL821AU 10 VDC 24.9 kohm XS821-22 or XSU821-22 cable cross-section: 0.25 1.50 mm² Vi 199.9 kohm (8.7 VDC if connection interrupted) sensor resistance NTC20K NTC10K 2 0,5 mm² 400 m shielded GND high-impedance active signals Vi 199.9 kohm 0(2) 10 VDC or 0(4) 20 ma via external 499 Ω resistor T7560A1026 T7560C1006 AQS51-KAM C7110D1009 SAF25 2 + 1 1.0 mm² 1.5 mm² 2.5 mm² 0.5 mm² (only with 24VAC via NYM or J- Y(ST)Y) 70 m 100 m 170 m 400 m 3 rd wire for 24 VAC power supply of active sensor; control signal shielded GND EN0B-0689GE51 R0114 2

Excel 800 I/O module signal type signal level Analog Output XF822A, XF822AU XFR822A, XFR822AU XFL822A, XFL822AU XFLR822A, XFLR822AU XS821-22 or XSU821-22 cable cross-section: 0.25 1.50 mm² Binary Input XF823A, XF823AU XFL823A, XFL823AU XS823 or XSU823 cable cross-section: 0.25 1.50 mm² Relay Output XF824A, XF824AU XFR824A, XFR824AU XFR825A, XFR825AU XFL824A, XFL824AU XFLR824A, XFLR824AU XS824-25 or XSU824-25 cable cross-section: 0.25 1.50 mm² 0(2) 10 VDC / 1 ma 0 VDC / 10 VDC if configured as binary output dry contact input totalizer relay contact XFR825 models use 2 relays to control a floating actuator Per NO contact: 19 250 VAC current at cos φ 0.6: 4 A 1 29 VDC 4 A resistive, 1 A inductive, min. load 50 mw Per NC contact: 19 250 VAC current at cos φ 0.95: 2 A, current at cos φ 0.6: 1 A 1 29 VDC 4 A resistive, 1 A inductive, min. load 50 mw Total per module: 19 250 VAC current at cos φ 0.6: 12 A 1 29 VDC 12 A resistive, 3 A inductive 0(2) 10 VDC open contact voltage 16 22 VDC, max 2 ma current for closed contact max. 20Hz pulse on: min. 25 ms pulse off: min. 25 ms bounce: max. 5ms 230 VAC 24VAC type of connected device, e.g. M7410E1002 ML7420/21 dry contact, e.g., end position from actuator totalizer with open collector output EXCEL 800 / EXCEL WEB II CABLE SPECIFICATIONS PRODUCT INFORMATION min. no. of wires 2 + 1 min. crosssection 1.0 mm² 1.5 mm² 2.5 mm² 0.5 mm² (only with 24VAC via NYM or J- Y(ST)Y) cable spec. H05V-K or similar shielded max. cable length at min. cross-section 70 m 100 m 170 m 400 m 20 m 400 m pump, fan, MT4-230 2 Calculate depending on required current ( max relay current) according to DIN57100 3 for floating M6410L, ML6420A part 523 or local guidelines. actuator MT4-024 2 M7410C, ML6425A, M6061A 3 for floating actuator 1.5 mm², 2.5 mm² H05V-K or shielded or NYM or NYM-J 100 m (1.5 mm²) or 170 m (2.5 mm²) note 3 rd wire for 24 VAC power supply of active sensor; control signal shielded Inside cabinets; follow EMC guidelines -- cable specification dependent on use (inside the cabinet, field wiring) and necessary voltage (24V/230V) 3 EN0B-0689GE51 R0114

Excel 800 I/O module signal type signal level Transformer CRT2, CRT6 or CRT12 EMEA: compliant to IEC61558-2-6 C-Bus LONWORKS Panel Bus type of connected device, e.g. min. no. of wires min. crosssection cable spec. max. cable length at min. cross-section primary power 230VAC line voltage 2 1.5 mm² H05V-K -- DIN57100 part 523 2 1.0 mm² LiYCY 2 m as short as possible use one twisted pair to connect an analog secondary power 24 VAC field device 2 + 2 1.5 mm² 100 m output and the other 2 3x2x0.8 pairs for the power supply Communication 19200 baud Communication > 19200 baud daisy chain wiring free topology wiring controller, e.g., controller, e.g., LON I/O module, XL10 room controller, LON I/O module, XL10 room controller, indoor: J- Y(St)Y 2x2x0.8 outdoor: A- 2Y(L)2Y 2x2x0.8 note 1200 m shielded twisted pair Belden 9841 1200 m shielded twisted pair 2x2x0.8 or Belden 8471 2x2x0.8 or Belden 8471 900 m or 2700 m 500 m; max. 320 m (400 m for Belden 8471) between any 2 devices max. 40m communication Panel I/O module 2 0.75 mm² power supply 24 VAC Panel I/O module 2 0.75 mm² J-Y-Y 2x2x0.8 3 m use 1 termination XAL -Term on each end of the wiring connect 1 termination XAL-Term use one twisted pair for communication and the other for power supply EN0B-0689GE51 R0114 4

EIA 485 CABLE SPECIFICATIONS The following cable specification is valid for all EIA 485 buses, e.g., Panel Bus and (Excel Web II, only) BACnet MS/TP. Table 1. EIA 485 cable specifications max. length Excel Web II: Panel Bus BACnet MS/TP (depending upon baud rate) Excel 800: 40-800 m 800-1200 m 40 m cable type characteristic impedance distributed capacitance between conductors distributed capacitance betw. conductors and shield twisted pair, shielded (foil or braided shields are acceptable) 100 130 Ω Less than 100 pf per meter (30 pf per foot) Less than 200 pf per meter (60 pf per foot) The following cables fulfill this requirement: AWG 18; J-Y-(St)-Y 2 x 2 x 0,8; CAT 5,6,7 cable (use only one single pair for one bus); Belden 9842 or 9842NH. Excel Web II Panel Bus Considerations RS485-1 (isolated) - Max. Panel Bus length: o 40 meters. Any type of cabling and topology (including star topology) possible. No additional end termination permitted. o 800 meters. Mandatory twisted-pair or telephone cable and daisy chain topology. The Excel Web II Controller must be positioned at one end of the Panel Bus, and an end termination (120 Ω) at the other end. Further, the three-position slide switch must be set to "END." RS485-2 (non-isolated) - Max. Panel Bus length: o 40 meters. Any type of cabling and topology (including star topology) possible. No additional end termination permitted. o 800 meters. Mandatory twisted-pair or telephone cable and daisy chain topology. The Excel Web II Controller must be positioned at one end of the Panel Bus, and an end termination (120 Ω) at the other end. - Must not extend beyond a single building or building floor. Excel Web II BACnet MS/TP Bus Considerations RS485-1 (isolated) Max. BACnet MS/TP bus length: 800-1200 meters, depending on baud rate - see Excel Web II Installation & Commissioning Instructions (Product Literature No.: EN1B-0555GE51) for details. Mandatory shielded, twisted-pair cable. Must conform to EIA-RS485 cabling guidelines. RS485-2 (non-isolated) Max. BACnet MS/TP bus length: 800-1200 meters, depending on baud rate - see Excel Web II Installation & Commissioning Instructions (Product Literature No.: EN1B-0555GE51) for details. Mandatory shielded, twisted-pair cable. Ground noise should not exceed the EIA-485 common mode voltage limit. Must conform to EIA-RS485 cabling guidelines. Should not extend beyond a single building. 5 EN0B-0689GE51 R0114

Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Rolle, Z.A. La Pièce 16, Switzerland by its Authorized Representative: Automation and Control Solutions Honeywell GmbH Böblinger Strasse 17 71101 Schönaich / Germany Phone: (49) 7031 63701 Fax: (49) 7031 637493 http://ecc.emea.honeywell.com Subject to change without notice. Printed in Germany EN0B-0689GE51 R0114