DUK. Ultrasonic Flowmeter/ -Monitor/-Counter/-Dosing Unit

Similar documents
DUK. Compact Ultrasonic Flowmeter

DVZ. Vortex Flowmeter Compact. for low viscosity liquids

DUK COMPACT ULTRASONIC FLOWMETER

Operating Instructions for Ultrasonic Flowmeter/ -Monitor/ - Counter/ -Dosing Unit. Model: DUK

TUR. Turbine Wheel Flowmeter. Plastic Model for Liquids. Measuring Ranges: GPM or GPM (Water)

Electromagnetic flowmeter in all metal design Model MIM

LTS. Resisitve Temperature Sensor hygienic design. Temperature. Measuring range: C Accuracy Class A according to DIN IEC 751 p

KAL-K. Electronic Flow Monitor. for liquids. Range: approx cm/s. p max : 100 bar. Temperature of medium: C Option: 0...

Magnetic Inductive Flowmeter

Level Sensors Reed Contact Chain

Coriolis Massflowmeter

Liquid Level Switches

Measuring range: l/h water m³/h air (20 C, bar) Connection: Flange DN 15...

Full Metal Variable Area Flowmeter and Counter Model BGF

LCI. Inductive Conductivity/ Concentration and Temperature Transmitter. Compact or separate version

BGN. All Metal Variable Area Flowmeter and Counter. for liquids and gases

KDS. All Metal Variable Area Flowmeter. for Liquids and Gases

DVZ COMPACT VORTEX FLOWMETER

Operating Instructions for Compact Vortex Flow Meter. Model: DVZ

Electronic Flow Monitor

MIM. Electromagnetic Flowmeter. Compact, All-metal Design

Coriolis Mass Flow Meter Model TM

Temperature Transmitters

ALGERIA, ARGENTINA, AUSTRALIA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHILE, CHINA,

Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040) Material: (316 L) / (316 Ti)/ Hastelloy C-22

S 4. Vane Flow Meter, Monitor, Counter, Batching System. in modular design for liquids. Measuring accuracy: ± 2.5% f.s. : 100 bar; t max : 80 C.

COMPACT-LINE. Transmitter for ph-value

NGR. Guided Wave Radar Level Transmitter

Operating Instructions for Compact Magnetic-Inductive Flow Meter. Model: MIK

TME. Coriolis Massflowmeter. for liquids and gases kg/h kg/h water. p max. : PN40 t max : C

Frame through-beam sensors

Insertion Thermocouples with Bayonet Lock

MIK COMPACT MAGNETO-INDUCTIVE FLOWMETER

Through-beam ring sensors

PSD. Digital Pressure Sensor. LED Display with Switch & Analog Outputs

COMPACT-LINE. KOBO-RP Transmitter for ORP Model ARM-Z

EXPERT-LINE. KOBO-pH. Transmitter for ph-value and ORP Model APM-X

BGF. All-Metal Armored Variable Area Flowmeter and Totalizer. for Horizontal or Vertical Mounting

Vane Flow Meter, Monitor, Counter, Batching System in Modular Design for Liquids

The compact test- disconnect terminal interface system for protection and secondary technology

COMPACT-LINE. KOBO-pH Transmitter for ph-value Model APM-Z

OVZ. Oval Wheel Flow Meter. for viscous liquids l/min liquid. Measuring accuracy: ± 2.5% f.s. p max : 40 bar; t max : 80 C

MIM. Electromagnetic Flowmeter. Compact, All-metal Design

BGF. Full Metal Variable Area Flow Meter and Counter. for horizontal and vertical mounting. Special versions up to 600 bar

DMH. Magnetic Inductive Flowmeter. for Conductive Fluids

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement

DOG-4. Oscillation Flowmeter. for gases. Measuring ranges: m 3 /h air. : PN 40; t max. p max : 120 C

Vane Flow Meter, Monitor, Counter, Batching System in Modular Design for Liquids

NBK-04. Level Indicator for Tank-Top Mounting

Process Control HPP-25

INSERTION paddle wheel flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement

DUC. Ultrasonic Flowmeter for Liquids. Portable or Stationary

Flow - Rotor. Characteristics. Applications. Mechanical-magnetical, Infrared. Quantity measurement for filling processes

Digital flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement

Table of Contents Executive Summary 29

Digital flow transmitter for continuous flow measurement

Process-Controller HPP-25

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

Operating Instructions for Microwave Level Switch. Model: LNM

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,

Level switch Nivotemp NT-EL, NT-ELD

Regulatory status for using RFID in the UHF spectrum 3 May 2006

Digital batch controller

Inclinometer Selection Guide

Who Reads and Who Follows? What analytics tell us about the audience of academic blogging Chris Prosser Politics in

Magnetic Inductive Flow Sensors induq. Series VMI

J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS. DB_Magnetic_Inductive_Flow_Sensors 05/2016

И М. 2 24VAC 50/60Hz, 24-48VDC VAC 50/60Hz

onlinecomponents.com

Brochure More information from

Magnetic Inductive Flow Sensors VMI Series

DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor

Flow - Rotor. Characteristics. Applications. Mechanical-magnetical, Infrared. Quantity measurement for filling processes

1204 Reflected Wave Reduction Device

ABB Oy, KPM. Sakeusmittaukset paperikoneen massanvalmistuksessa

Online data sheet FFUS15-1N1IO FFU FLOW SENSORS

Monthly Summary of Troop Contribution to UN Operations

M-2111 Series Ultrasonic Flow Meter

SUPER RGB Sensor. Lustre Detection Sensor Head. is newly developed. CZ-V20 Series. It can detect lustre without being affected by colours CZ-V20

Catalogue NE 0506 FIXTURING SYSTEM. Modular Zero-Point Fixturing for Pallets, Workpieces and Fixtures

Process Control Calibration Made Easy with Agilent U1401A

High-Accuracy Surface Scanning Method

Welcome to the IFR Press Conference 30 August 2012, Taipei

MICROFUSION SINGLE PHASE SCR POWER CONTROLLERS

RCM DIRECT READING FLOWMETER

Indicator (4digit) (5digit) 8-pin plug counter

NUS-4. Ultrasonic Level Transmitter. for Liquids and Solids

WFS Fork Sensors. Agile and flexible ideal mounting for labeling applications. P r o d u c t I n f o r m at i o n

INTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE:

stripax The professional stripping tool

2018/2019 HCT Transition Period OFFICIAL COMPETITION RULES

W 140: Miniature Photoelectric Switch Series with Large Scanning Ranges

FLOWave SAW-Flowmeter

Brunata Optuna H. Properties. Counter

Content. Flow meter F2-UN. Description Technical Data Dimension drawings Operation... 8 Mounting instructions...

Ultrasonic level transmitter, non-contact

LENORD. +BAUER... automates motion. Magnetic absolute rotary encoder GEL 2037 with heavy duty flange or tooth wheel adapter

Transcription:

Ultrasonic Flowmeter/ -Monitor/-Counter/-Dosing Unit measuring monitoring analysing DUK Measuring range: 0.08-0. - 630 L /min Accuracy: ±. % of F.S. Range span: 0 p max : 6 bar; t max : 90 C Connection: G ½ G 3, ½ 3 NPT IG Material: brass or st. st..4408 Analogue, frequency and switching s, compact electronic with digital display, dosing and counter electronic KOBOLD companies worldwide: ALGERIA, ARGENTINA, AUSTRALIA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHILE, CHINA, COLUMBIA, CZECHIA, DOMINICAN REPUBLIC, EGYPT, FRANCE, GERMANY, GREAT BRITAIN, HUNGARY, INDIA, INDONESIA, ITALY, MALAYSIA, MEXICO, MOROCCO, NETHERLANDS, PERU, PHILIPPINNES, POLAND, ROMANIA, SINGAPORE, SLOVAKIA, SOUTH KOREA, SPAIN, SWITZER- LAND, TAIWAN, THAILAND, TUNISIA, USA, VENEZUELA, VIETNAM KOBOLD Messring GmbH Nordring -4 D-679 Hofheim/Ts. Head Office: +49(0)69 99-0 +49(0)69 99-3398 info.de@kobold.com www.kobold.com

Description The new KOBOLD type DUK fl ow meters are used for the measurement, monitoring, metering and dosing of low viscosity fl uids. The devices work on the principle of the difference in running times. This is based on the fact that ultrasonic waves in a medium are infl uenced by the speed of fl ow. Two sensors mounted opposite one another in the pipeline function simultaneously as transmitter and receiver of ultrasound signals. If there is no fl ow, then the running times of both signals are identical. If the medium is fl owing, then the running time of the signal against the fl ow is longer than that with the fl ow. The running time difference, which is determined by a microprocessor, is proportional to the speed of fl ow. T V m C L Electronic The devices can be equipped with a switching, a frequency or an analogue. In addition, a compact circuit can be selected that features a digital display, a switching and an analogue. The device series is rounded off by an optionally available dosing and meter circuit. The meter circuit indicates the momentary fl ow rate in the fi rst line of the display and the partial or total quantity in the second line. A dosing circuit controls simple fi lling tasks and similarly measures fl ow rates, total amounts and fi lling amounts. The analogue and two relay s can be used for further processing of the signals. T Advantages High range span of :0 Small pressure loss High repeat accuracy ± 0.% of F.S. Independent from density and temperature Areas of Application Machine building Automotive Robotic Cooling Hot water Technical Data Sensor Measuring principle: Range: Medium: Viscosity: Accuracy: Repeat accuracy: Mounting position: ultrasonic see table liquids with max. % solid max. 3 mm²/s ±. % of F.S. ±0. % of F.S. In-/Outlet: Media temperature: - 0... +90 C Ambient temperature: - 0... + 70 C Response time: in all directions, fl ow in direction of the arrow (horizontal: electronic on top or below) 0 x DN approx. 0... s (depending on electronic version) Pressure: 0 6 bar Pressure loss: max. 0 mbar at F.S. Protection: IP 6 Wetted Parts Sensor housing: brass or st. st..4408 Sensors: PEEK Seal: NBR, other on request Measuring Ranges and Weights Model Measuring range [L / min] Size [G / NPT] DUK-...S30x DUK- F3xo DUK-...Lxx3 DUK-...C3xx DUK-...Exxx DUK-...Gxxx DUK with ADI 4 V DUK with ADI 30 / / 48 V DUK-xx4 0.08-0 ½" approx. 80 g approx. 00 g approx. 000 g approx. 0 g approx. 700 g DUK-xx 0.6-40 ¾" approx. 00 g approx. 0 g approx. 00 g approx. 30 g approx. 900 g DUK-xx6 0. - 63 " approx. 40 g approx. 60 g approx. 600 g approx. 70 g approx. 3300 g DUK-xx8 0.6-0 ½" approx. 30 g approx. 0 g approx. 00 g approx. 360 g approx. 400 g DUK-xx9-0 " approx. 3800 g approx. 4000 g approx. 390 g approx. 00 g approx. 60 g DUK-xxB. - 630 3" approx. 700 g approx. 7300 g approx. 70 g approx. 8400 g approx. 890 g www.kobold.com No responsibility taken for errors;

DUK-...S300, DUK-...S30D Duo-LED for switch status Switching (..S300): relay SPDT, max. A / 30 V DC Switching (..S30D): active 4 V DC, N/C and N/O Switch point: 0... 90 % of f.s. in 0 %- steps that can be confi gured by the customer using a rotary switch Power supply: 4 V DC ± 0 % Power consumption: 30 ma Electrical connection: plug M, -pin DUK-...F300, DUK- F390 Impulse : PNP, Open Collector, max. 00 ma Frequency at F.S.: 00 Hz ( F300) 0 000 Hz ( F390) proportional to fl owrate Power supply: 4 V DC ± 0 % Power consumption: ma Electrical connection: plug M, -pin DUK-...L303; DUK-...L343 Output: 0(4)-0 ma, 3-wire Power supply: 4 V DC ± 0 % Power consumption: max. 4 ma Electrical connection: plug M x DUK-...L443 (usage with AUF-3000) Output: 4-0 ma, 3-wire Power supply: 4 V DC ± 0 % Power consumption: max. 4 ma Electrical connection: plug DIN 4360 DUK-...C3xx (Compact electronic) 3-digit LED Analogue : 0(4)...0 ma adjustable (only DUK-...C34x) Switching : () semiconductor PNP or NPN, set at factory Contact function: N/C-N/O-frequency programmable (approx. 400 Hz at F.S., uncalibrated) via buttons Power supply: 4 V DC ± 0 % Power consumption: approx. 00 ma Electrical connection: plug M x DUK-...Exxx (Counter electronic) LCD, x 8 digit, illuminated total, part and fl ow quantities, units selectable Analogue 0(4)...0 ma adjustable Switching : relays, max. 0 V/ A /000 VA via 4 buttons Functions: reset, MIN/MAX memory, fl ow monitor, monitoring for part and total quantity, language Power supply: 4 V DC ± 0 %, 3-wire Power consumption: approx. 70 ma Electrical connection: cable connection or M plug more technical details see data sheet ZED in the brochure Z DUK-...Gxxx (Dosing electronic) LCD, x 8 digit, illuminated dosing-, total-, and fl ow quantity, units selectable Analogue 0(4)...0 ma adjustable Switching : relays, max. 0 V / A / 000 VA via 4 buttons Functions: dosing (relay S), start, stop, reset, fi ne dosing,correction amount, fl ow switch, total quantity, language Power supply: 4 V DC ± 0 %, 3-wire Power consumption: approx. 70 ma Electrical connection: cable connection or M plug more technical details see data sheet ZED in the brochure Z DUK with ADI electronic bar graph, 3.-digit digital or combination display; batch system Analogue : 0(4)... 0 ma, 0 0 V Switching : x relays / SPDT max. / 30 V AC, A resistive load max. 30 V DC / A or Open-Collector - 0 V DC, I total. = 0 ma via 3 buttons Power supply: 30 //48/4 V AC, 4 V DC Electrical connection: pluggable terminal block cable gland more technical details see data sheet ADI electronic in the brochure Z No responsibility taken for errors; www.kobold.com 3

Electrical Connection DUK-...S300 DUK-...S30D N/O common N/C N/C N/O DUK- F3x0, DUK-...L3x3 DUK-...L443 n.c. signal out 3 signal out +V S DUK-...C30* DUK-...C34* switch out 0(4)-0 ma switch out switch out DUK-...E4R, DUK-...G4R Cable Connection DUK-...E34R, DUK-...G34R Plug Connection Wire number DUK-...E4R counter electronic +4 V DC +4 V DC DUK-...G4R dosing electronic 3 0(4)-0 ma 0(4)-0 ma 4 reset part quantity Control * 6 n. c. Control * 7 relay S relay S 8 relay S relay S 9 relay S relay S 0 relay S relay S * Control <-> : Start-Dosing Control <-> : Stop-Dosing Control <-> Control <-> : Reset-Dosing +4 V DC reset/ctr * U 4 3 d.c./ctr * 30 V AC/DC / A U S 7 8 3 6 4 0 (4) - 0 ma out S 4 www.kobold.com No responsibility taken for errors;

Order Details (Example: DUK- G4H S300 L) Model / Housing material Connection* Electronic Flow direction Switching S300 = relay, M-plug S30D = active 4 V DC, M-plug Frequency F300 = M-plug, 00 Hz F390 = M-plug, 0 000 Hz DUK- = brass DUK- = st. st..4408 G4H = G ½ IG GH = G ¾ IG G6H = G IG G8H = G ½ IG G9H = G IG GBH = G 3 IG N4H = ½ NPT IG NH = ¾ NPT IG N6H = NPT IG Analogue L303 = M-plug, 0-0 ma L343 = M-plug, 4-0 ma L443 = DIN-plug, 4-0 ma Compact electronic C30R = x Open Collector, PNP C30M = x Open Collector, NPN C34P = 0(4)-0 ma, x Open Collector, PNP C34N = 0(4)-0 ma, x Open Collector, NPN ADI electronic Display Power supply Output Contacts B = bar graph 0 = 30 V AC 0 = without 0 = without L = from left to right R = from right to left T = from top to bottom B = from bottom to top N8H = ½ NPT IG N9H = NPT IG NBH = 3 NPT IG D = digital K = bar graph/ digital display A = dosing unit 4 = V AC = 48 V AC = 4 V AC 3 = 4 V DC = 0-0 V = 0-0 ma 4 = 4-0 ma = relay SPDT 6 = Open Collector Counter electronic E4R = LCD, 0(4)-0 ma, x relays, m cable E34R = LCD, 0(4)-0 ma, x relays, M-plug Dosing electronic G4R = LCD, 0(4)-0 ma, x relays, m cable G34R = LCD, 0(4)-0 ma, x relays, M-plug * Standard display in L/min, optional: display GPM (code G instead of H) Dimensions DUK-Sensor Model G/NPT SW H L B DUK-xxx4 ½ 30 7 4 ca.7 DUK-xxx ¾ 36 9 6. ca. 76 DUK-xxx6 46 66 ca. 80 DUK-xxx8 ½ 60 69 90 ca. 90 DUK-xxx9 76 74 38 ca. 97 DUK-xxxB 3 0 84 306 ca. No responsibility taken for errors; www.kobold.com

Dimensions DUK- S30x, DUK- F3x0, DUK- L3x3 DUK- L443 8 Mx 60 34 7. 8 DUK- C3xx DUK- ExxR, DUK- GxxR Ø44. 48 90 34 7 8. Mx ca. 6.. 60 7. 34 60 DUK with ADI electronic OBOLD 6 www.kobold.com No responsibility taken for errors;