Silicon Photomultiplier

Similar documents
Silicon Photo Multiplier SiPM. Lecture 13

Characterisation of SiPM Index :

Silicon Carbide Solid-State Photomultiplier for UV Light Detection

Tutors Dominik Dannheim, Thibault Frisson (CERN, Geneva, Switzerland)

A Measurement of the Photon Detection Efficiency of Silicon Photomultipliers

An Introduction to the Silicon Photomultiplier

Photon Count. for Brainies.

SILICON PHOTOMULTIPLIERS: FROM 0 TO IN 1 NANOSECOND. Giovanni Ludovico Montagnani polimi.it

Direct Measurement of Optical Cross-talk in Silicon Photomultipliers Using Light Emission Microscopy

SPMMicro. SPMMicro. Low Cost High Gain APD. Low Cost High Gain APD. Page 1

PoS(PhotoDet 2012)058

Direct Measurement of Optical Cross-talk in Silicon Photomultipliers Using Light Emission Microscopy

SiPMs for solar neutrino detector? J. Kaspar, 6/10/14

Introduction to silicon photomultipliers (SiPMs) White paper

Redefining Measurement ID101 OEM Visible Photon Counter

PoS(PhotoDet 2012)022

AND9770/D. Introduction to the Silicon Photomultiplier (SiPM) APPLICATION NOTE

AFBR-S4N44C013-DS100. Data Sheet. NUV-HD Silicon Photo Multiplier. Features. Description. Applications

InGaAs SPAD freerunning

SensL B-Series Silicon Photomultipliers for TOF- PET. NDIP2014 Kevin O Neill 4 th July, 2014

Recent Development and Study of Silicon Solid State Photomultiplier (MRS Avalanche Photodetector)

Geiger-mode APDs (2)

A BaF2 calorimeter for Mu2e-II

InGaAs SPAD BIOMEDICAL APPLICATION INDUSTRIAL APPLICATION ASTRONOMY APPLICATION QUANTUM APPLICATION

Timing Resolution Performance Comparison for Fast and Standard Outputs of SensL SiPM

Red, Green, Blue (RGB) SiPMs

AFBR-S4N44P163-DS102. Data Sheet. 4 4 NUV-HD Silicon Photo Multiplier Array. Description. Features. Applications

PRELIMINARY. Specifications are at array temperature of -30 C and package ambient temperature of 23 C All values are typical

Type Features Applications. Enhanced sensitivity in the UV to visible region

Silicon Photomultiplier Evaluation Kit. Quick Start Guide. Eval Kit SiPM. KETEK GmbH. Hofer Str Munich Germany.

Near Ultraviolet (NUV) SiPMs

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

OPTI510R: Photonics. Khanh Kieu College of Optical Sciences, University of Arizona Meinel building R.626

Detectors for microscopy - CCDs, APDs and PMTs. Antonia Göhler. Nov 2014

Engineering Medical Optics BME136/251 Winter 2018

The Benefits of Photon Counting... Page -1- Pitfalls... Page -2- APD detectors... Page -2- Hybrid detectors... Page -4- Pitfall table...

OFCS OPTICAL DETECTORS 11/9/2014 LECTURES 1

J-Series High PDE and Timing Resolution, TSV Package

arxiv: v2 [physics.ins-det] 17 Oct 2015

High collection efficiency MCPs for photon counting detectors

Highlights of Poster Session I: SiPMs

Optical Receivers Theory and Operation

NON-AMPLIFIED PHOTODETECTOR USER S GUIDE

Andrea WILMS GSI, Helmholtzzentrum für Schwerionenforschung, Darmstadt, Germany

Homework Set 3.5 Sensitive optoelectronic detectors: seeing single photons

Advancement in development of photomultipliers dedicated to new scintillators studies.

A flexible compact readout circuit for SPAD arrays ABSTRACT Keywords: 1. INTRODUCTION 2. THE SPAD 2.1 Operation 7780C - 55

DETECTORS Important characteristics: 1) Wavelength response 2) Quantum response how light is detected 3) Sensitivity 4) Frequency of response

Silicon Photomultipliers

TCSPC at Wavelengths from 900 nm to 1700 nm

Advanced Materials Research Vol

PoS(PhotoDet 2012)016

A New Single-Photon Avalanche Diode in 90nm Standard CMOS Technology

PCS-150 / PCI-200 High Speed Boxcar Modules

Silicon Photomultipliers. Dieter Renker

CHAPTER 9 POSITION SENSITIVE PHOTOMULTIPLIER TUBES

CMOS 0.18 m SPAD. TowerJazz February, 2018 Dr. Amos Fenigstein

Review of Solidstate Photomultiplier. Developments by CPTA & Photonique SA

Characterization of SiPMs for Large Scale Applications

Contents. The AMADEUS experiment at the DAFNE collider. The AMADEUS trigger. SiPM characterization and lab tests

CHAPTER 11 HPD (Hybrid Photo-Detector)

Light Collection. Plastic light guides

Lecture 12 OPTICAL DETECTORS

Optical Communications

Use of a Hybrid Photo Detector (HPD) in the MAGIC micro power LIDAR system

MICRO PIXEL AVALANCHE PHOTODIODE AS ALTERNATIVE TO VACUUM PHOTOMULTIPLIER TUBES

Application Notes: Discrete Amplification Photon Detector 5x5 Array Including Pre- Amplifiers Board

Development of Photon Detectors at UC Davis Daniel Ferenc Eckart Lorenz Alvin Laille Physics Department, University of California Davis

Solid State Photomultiplier: Noise Parameters of Photodetectors with Internal Discrete Amplification

SiPMs as detectors of Cherenkov photons

IRST SiPM characterizations and Application Studies

Nuclear Instruments and Methods in Physics Research A

FACTOR: first results on SiPM characterization

SINPHOS SINGLE PHOTON SPECTROMETER FOR BIOMEDICAL APPLICATION

RECENTLY, the Silicon Photomultiplier (SiPM) gained

Photons and solid state detection

Today s Outline - January 25, C. Segre (IIT) PHYS Spring 2018 January 25, / 26

Working in Visible NHMFL

Study of Silicon Photomultipliers for Positron Emission Tomography (PET) Application

Characterizing a single photon detector

Scintillation Counters

arxiv:hep-ex/ v1 19 Apr 2002

Spectroscopy in the UV and Visible: Instrumentation. Spectroscopy in the UV and Visible: Instrumentation

C30902 and C30921 Series High-speed solid state detectors for low light level applications

Boston Electronics Corporation 91 Boylston Street, Brookline MA USA (800) or (617) fax (617)

How to Evaluate and Compare Silicon Photomultiplier Sensors. October 2015

arxiv: v3 [astro-ph.im] 17 Jan 2017

Solid-State Photomultiplier in CMOS Technology for Gamma-Ray Detection and Imaging Applications

HF Upgrade Studies: Characterization of Photo-Multiplier Tubes

AN ADVANCED STUDY OF SILICON PHOTOMULTIPLIER

Characterization of a prototype matrix of Silicon PhotoMultipliers (SiPM s)

event physics experiments

Experiment 10. The Speed of Light c Introduction Apparatus

Overview Full Featured Silicon Photomultiplier Module for OEM and Research Applications The is a solid state alternative to the Photomultiplier Tube (

Ground-based optical auroral measurements

R & D for Aerogel RICH

A Study of Silicon Photomultiplier Sensor Prototypes for Readout of a Scintillating Fiber / Lead Sheet Barrel Calorimeter

Photomultiplier & Photodiode User Guide

Detectors for Optical Communications

NMI3 Meeting JRA8 MUON-S WP1: Fast Timing Detectors High Magnetic Field µsr Spectrometer Project at PSI Status Report

Transcription:

Silicon Photomultiplier Operation, Performance & Possible Applications Slawomir Piatek Technical Consultant, Hamamatsu Corp.

Introduction Very high intrinsic gain together with minimal excess noise make silicon photomultiplier (SiPM) a possible choice of a photodetector in those applications where the input light is in the photon-counting range. 2

Introduction This webinar is a high-level review of SiPM s structure, operation, and opto-electronic characteristics, followed by a discussion of some possible applications. 3

Outline Structure and operation Opto-electronic characteristics Applications + Automotive ToF LiDAR + Flow cytometry + Radiation detection and monitoring Summary and conclusions 4

SiPM Structure and Operation of a SiPM Portraits of SiPMs (images not to scale) 5

Side view Top view SiPM structure SiPM is an array of microcells p + n + p+ π Single microcell = R Q oxide APD electrical equivalent circuit of a microcell 6

SiPM structure Cathode... R Q APD single microcell Anode All of the microcells are connected in parallel 7

SiPM specifications Active area: 1.3 1.3 6 6 mm 2 Microcell size (pitch): 10 10, 15 15, 25 25, 50 50, 75 75 μm 2 Number of microcells: (active area)/(microcell size), from 100 s to 10,000 s Overvoltage: ΔV = V BIAS V BD ; recommended by the manufacturer 8

Amplitude [mv] SiPM operation V BIAS > V BD K A R L G time [ns] Example of single-photoelectron waveform (1 p.e.) Gain = area under the curve in electrons 9

Amplitude [mv] SiPM operation Fast component RC time constant of the slow component depends on microcell size (all else being equal) Slow component Recovery time t R 5 times the RC time constant t R is on the order of 10 s to 100 s ns but in practical situations, it is also a function of detection bandwidth time [ns] 10

Arb. SiPM operation Current pulses due to photons The output of an SiPM is a chronological superposition of current pulses SiPM also outputs current pulses even in absence of light: dark counts (dark current) time 11

Arb. Dark Counts Current pulses due to photons and dark counts are indistinguishable Dark-count pulses are indistinguishable from those due to photons The rate of dark counts depends on overvoltage, temperature, and size of the active area time 12

Arb. Crosstalk 2 p.e. crosstalk event time Primary discharge can trigger a secondary discharge in neighboring microcells. This is crosstalk. Crosstalk probability depends on overvoltage 13

Operation light V BIAS 1, 2, 3,. counter If the pulses are distinguishable, SiPM can be operated in a photon counting mode. V BIAS SiPM 0 100 V or I If the pulses overlap, the SiPM can be operated in an analog mode. The measured output is voltage or current. 14

SiPM detection circuits V BIAS V BIAS C R C R R F SiPM R L V/V V out SiPM + TIA - V out 15

SiPM Performance and characteristics 16

Characteristics of a SiPM Photon detection efficiency Gain Temperature effects Crosstalk probability Dark current & dark counts Linearity & dynamic range 17

Photon detection efficiency [%] Photon detection efficiency Photon detection efficiency (PDE) is a probability that an incident photon is detected. It depends on: - wavelength - overvoltage - microcell size Peak PDE 20% 50% wavelength [nm] 18

Photon detection efficiency [%] Photon detection efficiency 30 Examples of PDE curves for 25 SiPMs optimized for NIR, VIS, and UV response. 20 15 10 5 wavelength [nm] 19

Gain Gain S13720, 1.3 1.3 mm 2 25 μm Crosstalk prob. & PDE Gain of SiPM is comparable to that of a PMT. Excess noise very low: F ~ 1.1, mostly due to crosstalk Gain depends linearly on overvoltage Overvoltage [V] 20

Gain [ 10 6 ] Gain versus temperature Does gain of an SiPM depend on temperature? Yes if the bias voltage is fixed Otte et al. (2016) Reverse bias voltage [V] 21

Gain variation [%] Gain versus temperature Does gain of an SiPM depend on temperature? No if the overvoltage is fixed Fixed overvoltage Temperature [ C] 22

Crosstalk S13720, 1.3 1.3 mm 2 25 μm Crosstalk prob. & PDE P CT increases with overvoltage Crosstalk is the main contributor to excess noise F (1+P CT ) Overvoltage [V] 23

Dark current [A] Dark Current S13720, 1.3 1.3 mm 2 Example of dark current versus overvoltage 25 μm DCR = I D /eμ Overvoltage [V] I D = 1 10-7 A (at 7 V) μ = 1.2 10 6 (at 7 V) -> DCR 520 khz or once per about 2 μs 24

Output current [A] Linearity and dynamic range S13720, 1.3 1.3 mm 2 Example of output current versus incident light level. 25 μm Photon irradiance (at 850 nm) = 4.3 10 18 P[W] P = 10-8 W > 4.3 10 10 photons per second Linearity depends on the number of microcells for a given active area Incident light level (850 nm) [W] 25

SiPM, PMT & APD This webinar will compare and contrast SiPM with a photomultiplier tube (PMT) and APD. Let s briefly review the operation of a PMT and APD Examples of a PMT (left) and APD (right). 26

100 mv/div Operation of a PMT K e P R f I K D 1 D 2 D 3 D 4 D 5 D 6 I P C 1 C 2 C 3 R 1 R 2 R 3 R 4 R 5 R 6 R 7 Typical voltage divider V ~ 1000 V 2 ns/div 27

SiPM versus PMT Solid state versus vacuum tube technology Comparable gains Comparable excess noise Comparable photosensitivity in the spectral overlap region Greater optimization for PMTs Dark count rate per unit active area larger in SiPM E & B field immunity in SiPM 28

Operation of an APD self-quenching avalanche APD biased below breakdown voltage photon holes electrons Single photon can lead up to about 100 of electron-hole pairs I PH R L Thus gain up to ~100 Avalanche is self-quenching V BIAS 29

log(gain) SiPM versus APD Differ in construction Gain = 1 linear region Geiger region Gain SiPM >> Gain APD F SiPM << F APD V BD V BIAS APDs SiPMs 30

Possible applications of SiPMs Automotive time-of-flight LiDAR Flow cytometry Radiation detection and monitoring 31

Automotive time-of-flight LiDAR How far is this tree? LiDAR LiDAR = Light Detection and Ranging 32

Automotive ToF LiDAR: basic concept start pulse fast photodetector emitted pulse laser beam splitter emission optics w = cτ to target timer returned pulse after Δt stop pulse collection optics 33

Automotive ToF LiDAR: basic concept Measure round-trip time-of-flight Δt Range (distance to the reflection point) = cδt/2; here c is the speed of light By scanning the surroundings, a 3D map can be constructed 34

Characteristics of received light Wavelength: 905 nm or 1550 nm Pulse: duration 2 5 ns No. of photons per returned pulse: 100 s 10,000 s on detector s active area Repetition frequency: khz - MHz DC photon background 35

Photodetector requirements High quantum efficiency at 905 nm and/or 1550 nm (affects detection range) High detector (intrinsic) gain (reduces importance of electronic noise) Small excess noise (affects timing error) Small time jitter (affects distance resolution) APD has been a default detector. Could SiPM be a better choice? 36

Photon detection efficiency [%] Quantum efficiency [%] Photosensitivity S13720 SiPM S10341 Si APD Wavelength [nm] Wavelength [nm] 37

Gain Gain Intrinsic gain S13720 SiPM Overvoltage [V] S10341 Si APD Reverse voltage [V] 38

Excess noise factor Excess noise S13720 SiPM Crosstalk probability [%] S10341 Si APD Overvoltage [V] F 1+P CT = 1.06 Gain F (Gain) 0.3 = 3.2 for gain = 50 39

Time jitter There are two contributions to timing jitter: 1. Classical jitter variation in response time, often reported for a single photon illumination. This contribution is on the order of 100 ps for SiPMs and APDs 2. Time-walk effect. For a constant trigger level, timing depends gain variation and signal intensity. 40

arb. Time jitter For a given light level SiPM has smaller time-walk effect because of its lower excess noise. trig. level Different trigger times: time walk effect time 41

Take-away points 1. SiPMs are likely to compete successfully with APDs at 905 nm because of their higher gain and much lower excess noise. Empirical evidence is forthcoming. 2. Sensitivity at 905 nm will improve in a new generation SiPMs 3. SiPMs with sensitivity at 1550 nm are being developed. 42

Flow cytometry Studying biological cells with light 43

Flow cytometry (basic concept) flow Side-scatter photodetector Data processing Laser flow Forward-scatter photodetector 44

Flow cytometry fluorescent dye Excitation light Fluorescent light cell Flow cytometry also uses fluorescence tagging to study cells 45

Flow cytometry Used to study and sort biological cells Side-scatter signal vs. forward scatter signal depends on cell properties Fluorescence is also employed (dyes attached to cells) to produce a variety of plots using fluorescence signal(s) The optical system employs a combination of lasers (different wavelengths), optical filters, and photodetectors 46

Side scatter signal Flow cytometry data Side scatter vs. forward scatter plot the most fundamental in flow cytometry Cell s characteristics such as size, complexity, or refractive index affect the relative strengths of side scatter and forward scatter signals Forward scatter signal 47

Characteristics of received light Wavelength: can be selected depending on cell sizes and fluoresce Pulses duration dependent on sheath flow speed and cell size and is on the order of μs. No. of photons per pulse varies from few to thousands Rate of pulses in khz 48

Side-scatter photodetector requirements High photodetection efficiency (affects S/N of detection) High intrinsic gain (reduces importance of electronic noise) Minimal excess noise (affects accuracy of the scatter plots; random noise) High linearity (affects accuracy of the scatter plot; systematic errors) High dynamic range (affects accuracy of the scatter plot; systematic errors) PMT is commonly used. Could SiPM be a better choice? 49

PDE [%] Cathode radiant sensitivity [ma/w] Photosensitivity S13360 3 3 mm 2, 25 μm 14,400 microcells H10720 QE 28% at 450 nm Wavelength [nm] Wavelength [nm] 50

Gain Gain Gain S13360 3 3 mm 2, 25 μm 14,400 μcells H10720 Overvoltage [V] Control voltage [V] 51

Excess Noise F 1+P CT (SiPM) Excess noise increases with gain F δ/(δ 1) (PMT; δ gain of the first dynode ) Excess noise decreases with gain 52

Deviation [%] Linearity/dynamic range (PMT) H10720 10% nonlinearity: 75 ma, T P = 500 ns Gain = 2 10 6, QE = 28% No. of incident photons at 450 nm: 4.2 10 5 Output current [ma] 53

Linearity/dynamic range (SiPM) N tot = 14,400; PDE = 25%, t r = 50 ns N γ. PDE = 1.1 10 5 (ideal response) N fired = 0.75 10 5 or 32% below an ideal response 54

Take-away points 1. The major weakness of SiPMs in flow cytometry is limited dynamic range and linearity 2. However, out of dozens of optical channels in a flow cytometer, SIPM can be suitable for some 3. There is a great interest in using SiPMs in flow cytometry but little published work on this subject exists 55

Radiation monitoring and spectroscopy 56

Output Radiation monitoring (basic idea) radiation events Ionizing radiation trigger level Scintillator Photodetector time An event is registered if the output signal exceeds the threshold level. 57

Radiation monitoring (basic idea) 1,2,3 Amplifier Discriminator Counter Used to detect the presence of specific radiation Monitoring devices are often portable and hand-held. Information provided: radiation rate (flux can be derived) 58

Characteristics of received light Wavelength dependent on the choice of scintillator often in the 300 nm 500 nm range Pulses Number of photons per pulse depends on energy of ionizing radiation and type of scintillator Duration of the pulse depends on the size and type of the scintillator (decay time constants range from ns to μs) Frequency of pulses depends on the rate of incoming radiation 59

Photodetector requirements High photodetection efficiency High intrinsic gain Large active area Ability to couple to a scintillator Suitable for portable hand-held devices 60

Radiation spectroscopy R C Charge integrator Ionizing radiation Scintillator Photodetector 61

No. of events Radiation spectroscopy (basic idea) V/V A/D Charge integrator Discriminator Computer Resolution = FWHM E FWHM E Energy Resolution is affected by the properties of the photodetector and the scintillator. 62

Photodetector requirements High photodetection efficiency (affects S/N of the detection and thus resolution) High intrinsic gain (reduces the importance of electronic noise and, thus, better count rate and measurable lower energy levels) Low excess noise (affects energy resolution) High linearity (affects systematic errors and energy range) Ability to couple to a scintillator 63

Radiation detection photodetectors PMTs used to dominate the detector choice in radiation detection, monitoring, and spectroscopy. SiPMs are becoming a viable alternative. Due to a multitude of possible detection scenarios, it is best to perform a side-by-side comparison between an SiPM and a PMT. 64

Number of counts Number of counts SiPM vs. PMT in γ-ray detection SiPM PMT Energy [MeV] Energy [MeV] Example of energy spectra from Grodzicka et al. 2017 [Nuclear Inst. and Methods in Physics Research, A 874 (2017) 137 148] 65

SiPM vs. PMT in γ-ray detection SiPM PMT comparison for different energies and scintillators from Grodzicka et al. 2017 [Nuclear Inst. and Methods in Physics Research, A 874 (2017) 137 148] 66

Take-away points 1. SiPMs provide comparable performance to PMTs in radiation monitoring and spectroscopy 2. It is likely that the majority of hand-held devices will employ SiPMs 3. Side-by-side comparison is the best approach in deciding if an SiPM or a PMT should be used for a given detection application 67

Summary and conclusions High gain, low excess noise, magnetic immunity, and ease of use are some of the highly desirable characteristics of SiPMs There is a great interest in using SiPMs instead of APDs and PMTs in a variety of applications New generation SiPMs will have improved characteristics making the transition more likely 68

Visit Booth #521 & Presentations at PW18 Development of an InGaAs SPAD 2D array for Flash LIDAR Presentation by Takashi Baba, January 29, 2018 (11:00 AM - 11:30 AM) Development of an InGaAs MPPC for NIR photon counting applications Presentation by Yusei Tamura, January 30, 2018 (5:50 PM - 6:10 PM) Photodetectors, Raman Spectroscopy, and SiPMs versus PMTs One-day Workshop with Slawomir Piatek, January 31, 2018 (8:30 AM - 5:30 PM) Free Registration Needed Development of a Silicon hybrid SPAD 1D array for LIDAR and spectrometers Poster session with Shunsuke Adachi, January 31, 2018 (6:00 PM - 8:00 PM) 69

Thank you for listening! Slawomir Piatek piatek@njit.edu 70