Line Tuners. Total Relay Communications

Similar documents
E (Capacitor Voltage Transformers) Transformer section of the Trench catalogue. Product Range

Current Transformers. Type OSKF

Inductive Voltage Transformers. Types VEOT and VEOS

Combined Instrument Transformers. Types IVOKT and TMC

Earth-Fault Compensation Controller EFC30 / EFC40

LOPO. Low Power Instrument Transformers. For Medium Voltage Switchgear

Excellence in Instrument Transformers

with our customers. marketplace. Trench is an international market leader, with strengths that

r ADDENDUM FOR REAR-OF-BOARD VERSION LFS - R

INSTRUMENT TRANSFORMERS. Product Spectrum

Coil Products Beginnings 1960 State of the Art. Customer partnership around the globe. Continuous innovation since 1900

Transmission Lines and Feeders Protection Pilot wire differential relays (Device 87L) Distance protection

Conducted Spurious Emission into VSWR Measurement Method

R-F Skewed Hybrids. Type H1SB and H1SB-R. & R-F Balanced Hybrids Type H1R, H3X and Type H1RB, H3XB and Type H1RB-40. System Manual CH44 VER03

USER MANUAL. Integration Kit BKIT MCINT BKIT MCIHT. Integration Kit for: Maxwell Technologies Ultracapacitor Cells

Central Electronics Model 600L Linear Amplifier

Capacitive voltage transformers

Easy-To-Use Graphic Interface

Keysight Technologies Using a Network and Impedance Analyzer to Evaluate MHz RFID Tags and Readers/Writers

Application Note MX860803A/MX860903A. cdma Measurement Software. MS8608A/MS8609A Digital Mobile Radio Transmitter Tester

Read-only Transponder TK5530

Bulk Flat Flexible Cables FLEXLINK

VARISPEED-616G5 OPTION CARD DIGITAL REFERENCE CARD DI-16H2 INSTRUCTIONS

Hands On Relay School 2017

communication networks Power Line Carrier Communication. Design and Engineering.

Process Control HPP-25

STUDY AND COMPARISON OF VARIOUS COMMUNICATION BASED PROTECTIVE RELAYING SCHEMES FOR ELECTRICAL POWER TRANSMISSION SYSTEM

TRANSIENT EMISSION SET AUTOMOTIVE TRANSIENT EMISSION MEASUREMENTS AS PER ISO

Copper Lines and High Speed

Quadrupole Power Supply Unit QPS400-3

DIRECT/INDIRECT HEALTHCARE & SENIOR CARE LIGHTING

Appendix S: PROTECTION ALTERNATIVES FOR VARIOUS GENERATOR CONFIGURATIONS

Capacitive voltage transformers

2-channel speed sensor GEL 247 Compact sensor for harsh applications

onlinecomponents.com

W FXS LS/GS Channel Unit 600 Ohms

CP6 6 Band Trap Vertical 80-6m

Solutions for PET Air Conveyors

PB1651PWM1 Module. User s Guide

USER MANUAL. Maxwell Technologies. Integration Kit. Models: BKIT MCINT BKIT MCIHT.

USER MANUAL. Maxwell Technologies Ultracapacitor Energy Storage Modules. Models: BMOD0058 E016 B02 BMOD0006 E160 B02. Document

MINAC Series Single and Twin. Mobile Induction Heating Equipment PRODUCT DESCRIPTION

Keysight Technologies Network Analyzer Measurements: Filter and Amplifier Examples. Application Note

Keysight 8474B/C/E Planar-Doped Barrier Diode Detectors 0.01 to 50 GHz. Data Sheet

Frequency Domain Analysis of Capacitor Transient Overvoltages

Precision Spectra OMG

OFFICIAL WARWICK AMP OWNER MANUAL

Keysight Technologies Essential Capabilities of EMI Receivers. Application Note

Comparison of MS2830A and NF Analyzer for Noise Figure Measurement

USER MANUAL. Maxwell Technologies BOOSTCAP Ultracapacitor Energy Storage Modules for Low Duty Cycle Applications

CTR2 / CTR2-AD CALIBRATION TARGET AND VERIFICATION ADAPTER FOR ESD

Low-power Flasher IC with 18-m Shunt U6432B

AC Dielectric Test Sets

Proper Bias-T Usage to Avoid PPG Damage

LPR Series PCB Snap-In Large Capacitors

Single Line Diagram of Substations

CTR2 / CTR2-AD CALIBRATION TARGET AND VERIFICATION ADAPTER FOR ESD

SHIMADZU GENERAL RADIOGRAPHIC SYSTEM

Next Generation Earth Stations Pointing the Way

Keysight 8762F Coaxial Switch 75 ohm

RAP Ripple Control Coupling for parallel injection of RC signals in Medium and High Voltage Networks

Agilent 8762F Coaxial Switch 75 ohm

Comparison of MS2830A/MS2840A and NF Analyzer for Noise Figure Measurements

MS9740A Optical Spectrum Analyzer New function introduction

SYSTEMS SOLUTIONS Smart multi-utility metering


Product Introduction. MF2400C Series. Microwave Frequency Counter

Product Introduction. MF2400C Series. Microwave Frequency Counter

Specification Sheet FRi-122/64

The machine tool business of SKF. The profile

Installation Solutions. Cable assembly according to Siemens 6FX standard

DeltaMyc. Fluorescence Lifetime Mapping Microscope. Affordable Fluorescence Lifetime Imaging Microscopy (FLIM)

Flasher, 18-mΩ Shunt, Frequency Doubling Disabling U6433B

Keysight Technologies N2792A/N2818A 200 MHz and N2793A/N2819A 800 MHz Differential Probes. Data Sheet

WHITEPAPER. Advantages of Christie Vive Audio planar ribbon and line array technologies for cinema sound

Keysight Measuring High Impedance Sources Using the U8903B Audio Analyzer. Application Note

CX-A6 Amplifier Installation & User Guide V8.0

Soldering Guide: Small and Medium Ultracapacitor Cells

CX-A6 Amplifier Installation & User Guide V9.0

BCA. Combiners and Filters for FM Broadcast and TV Systems

PRODUCT SPECIFICATIONS

12.5 Gb/s Driver Amplifier LABware Module PSPL8001 Datasheet

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Inductors, Chokes, Reactors, Filters

SGMF(T) series. Onsite Mobile AC High Voltage Test System. Applications:

Onsite Mobile AC High Voltage Test System

Ohmic Voltage Sensor GSER 16

Unit 2. Single Line Diagram of Substations

Handheld 3.3GHz Spectrum Analyzer

Mixing Amplifier MA 247MR

Keysight E5063A ENA Series Network Analyzer

/04 2-Wire Foreign Exchange Office (2W FXO) Channel Units

Keysight Technologies N9398C/F/G and N9399C/F DC Block. Technical Overview

SPINNER PMR Portfolio

ELECTRONIC LOUDSPEAKER SYSTEM CONTROLLER TX3 USER MANUAL

MD 200A High voltage differential probe

MBR10xCT Series TO-220AB

LE160 LE320 Linear Equalizer Datasheet Tektronix Linear Equalizer

THIS DOCUMENT IS FOR MAINTENANCE PURPOSES ONLY AND IS NOT RECOMMENDED FOR NEW DESIGNS

Input Return Loss, db > 26 Narrowband to Narrowband Isolation, db > 30

Transcription:

Total Relay Communications

PLC and Components Introduction...1-1 CL02B Resonant...2-1 CL03A Wide-band...3-1 CL13, CL14 Tuning Components...4-1 Carrier Frequency Hybrids...4-5 Balance Combiners...4-9 Lead-in Conductors...4-10 Component Listings...4-11 Data subject to change without notice

Efficient coupling of power line carrier signals into high voltage transmission lines. CL02/CL03 Application Transfer-trip and line relaying Directional or phase comparison Voice communication CL03 Efficient coupling of PLC signals to power lines CL02B are resonant line tuners CL03A are wide band line tuners CL02 DESCRIPTION Line tuning equipment, associated coupling capacitors, and line traps provide an efficient means to couple power line carrier (PLC) signals onto a high voltage overhead transmission line or power cable. Line tuners are also used in carrier bypass circuits to route PLC signals around discontinuities, such as transformers, breakers, and disconnect switches. The CL02B and CL03A are designed to deliver maximum power to the high voltage line at the selected PLC frequencies and to attenuate unwanted frequencies. All tuners provide a very high attenuation to 60 Hz currents and voltages. An impedance matching transformer (IMT) in the tuner allows matching of various overhead line impedances to the low coaxial cable and equipment impedance. This provides a high return loss path, or low reflective power, in the desired passband range of frequencies. A low impedance IMT is available for power cable applications. Resonant and wide-band line tuners provide a choice of frequency ranges and power ratings in various coupling arrangements. The entire PLC frequency range, from 30 to 500 khz can be accommodated. Power ratings up to 200 W are available. Wide-band tuners are available with up to five resonant circuits for maximum coupling bandwidth for power cables, and for use with small coupling capacitors at lower carrier frequencies. Each line tuner is housed in an outdoor cabinet. Page 1-1 Data subject to change without notice

Introduction To Line Tuning Data subject to change without notice Page 1-2

Introduction To Line Tuning Page 1-3 Data subject to change without notice

Introduction To Line Tuning Data subject to change without notice Page 1-4

Introduction To Line Tuning Page 1-5 Data subject to change without notice

Introduction To Line Tuning Data subject to change without notice Page 1-6

CLO2B Resonant Page 2-1 Data subject to change without notice

CLO2B Resonant Data subject to change without notice Page 2-2

CLO2B Resonant Page 2-3 Data subject to change without notice

CLO2B Resonant Data subject to change without notice Page 2-4

CLO2B Resonant Page 2-5 Data subject to change without notice

CLO2B Resonant Data subject to change without notice Page 2-6

CLO3A Wide-band Page 3-1 Data subject to change without notice

CLO3A Wide-band Data subject to change without notice Page 3-2

CLO3A Wide-band Page 3-3 Data subject to change without notice

CLO3A Wide-band Data subject to change without notice Page 3-4

CLO3A Wide-band Page 3-5 Data subject to change without notice

CLO3A Wide-band Data subject to change without notice Page 3-6

CLO3A Wide-band Page 3-7 Data subject to change without notice

CLO3A Wide-band Data subject to change without notice Page 3-8

CL13 and CL14 Line Tuning Components Page 4-1 Data subject to change without notice

CL13 and CL14 Line Tuning Components Data subject to change without notice Page 4-2

CL13 and CL14 Line Tuning Components Page 4-3 Data subject to change without notice

CL13 and CL14 Line Tuning Components Data subject to change without notice Page 4-4

CL13 and CL14 Line Tuning Components Page 4-5 Data subject to change without notice

CL14 Line Tuning Components Data subject to change without notice Page 4-6

CL14 Line Tuning Components Page 4-7 Data subject to change without notice

CL14 Line Tuning Components Data subject to change without notice Page 4-8

Balanced Combiner Line Tuning Components Page 4-9 Data subject to change without notice

Lead-in Conductors Data subject to change without notice Page 4-10

CL13 and CL14 Line Tuning Components Page 4-11 Data subject to change without notice

CL13 and CL14 Line Tuning Components Data subject to change without notice Page 4-12

Maintenance Manual ALL INSTRUCTIONS All instructions for installation, alignment and maintenance of the products contained in this brochure are contained on a CD. One CD is shipped with each product. The CD contains all the information and drawings associated with any model configuration. In addition, the CD can sort the specific text and drawings for the exact model purchased. A hard copy of this material covering all models is available upon request. Data subject to change without notice

Trench Facilities The Trench Group is your partner of choice for electrical power transmission and distribution solutions today; and for the development of your new technology solutions of tomorrow. Trench Austria GmbH Paschinger Strasse 49 Postfach 13 A-4060 Linz-Leonding Austria Phone: 43-732-6793-0 Fax: 43-732-671341 Trench Brasil Ltda Via Expressa de Contagem, 2685 Contagem, Minas Gerais CEP 32370-485 Brazil Phone: 55-31-3391-5959 Fax: 55-31-3391-1828 Trench China MWB (Shanghai) Co., Ltd. No. 3658, Jiancheng Road Minhang, Shanghai Peoples Republic of China 200245 Phone: 86-21-54720088 Fax: 86-21-54723118 Trench High Voltage Products Ltd., Shenyang No. 2 Zhengliang Er. Road Jing Shen Xi San Street Dao Yi Economic Development Zone Shenyang 110136 P.R. China Phone: 86-24-89722688 Fax: 86-24-89737200 Trench Limited Bushing Division 432 Monarch Avenue Ajax, Ontario Canada L1S 2G7 Phone: 905-426-2665 Fax: 905-426-2671 Trench Limited Coil Product Division 71 Maybrook Drive Scarborough, Ontario Canada M1V 4B6 Phone: 416-298-8108 Fax: 416-298-2209 Trench Limited Instrument Transformer Division 390 Midwest Road Scarborough, Ontario Canada M1P 3B5 Phone: 416-751-8570 Fax: 416-751-6952 Trench Limited Power Line Carrier Division 815 Middlefield Road, Unit 6A Scarborough, Ontario Canada M1V 2P9 Phone: 416-291-8544 Fax: 416-291-5581 Trench France S.A. 16, Rue du Général Cassagnou B.P. 70 F-68 302 St. Louis, Cedex France Phone: 33-3 89-70-2323 Fax: 33-3 89-67-2663 Trench Germany GmbH Nürnberger Strasse 199 D-96050 Bamberg Germany Phone: 49-951-1803-0 Fax: 49-951-1803-224 Trench Switzerland AG Lehenmattstrasse 353 CH-4028 Basel Switzerland Phone: 41-61-315-51-11 Fax: 41-61-315-59-00 Trench (UK) Limited South Drive Hebburn Tyne & Wear NE 31 1 UW Phone: 44-191-483-4711 Fax: 44-191-430-0633 www.trenchgroup.com E 239.31 Subject to change without notice (05.2006) Printed in Canada.