PRODUCT DATA. PULSE Multichannel Sound Power Type 7748 Version 1.2

Similar documents
PRODUCT DATA USES. BENEFITS Normal incidence parameters are determined Fast and accurate measurements. Type 4206A. Type Type 4206T 50 Hz 1.

NON-SELLABLE PRODUCT DATA

PRODUCT DATA. Sound Intensity Calibrator Type 4297

Mr. Wolfgang Metzen was trained as a mechanical

PRODUCT DATA. Sound Intensity Probe Kit Type 3599 Sound Intensity Microphone Pair Type 4197 Dual Preamplifier Type 2683

APPLICATION NOTE 3560/7702. Introduction

PRODUCT DATA. Pocket Front-end Type 3560 L PULSE Lite Software Types 7781, 7782, 7783

PRODUCT DATA. Piezoelectric Accelerometer Miniature Triaxial DeltaTron Accelerometers Types 4524, 4524 B

PRODUCT DATA. Sound Intensity Probe Kit for 2260 Type 3595 Sound Intensity Microphone Pair Type 4197 Dual Preamplifier Type 2683

P R O D U C T D A T A

PRODUCT DATA. Falcon Range 1/4-inch Microphone Preamplifier Type 2670

PRODUCT DATA. DIRAC Room Acoustics Software Type Photo courtesy of Muziekcentrum Frits Philips, Eindhoven, The Netherlands

NON-SELLABLE PRODUCT DATA. Order Analysis Type 7702 for PULSE, the Multi-analyzer System. Uses and Features

PRODUCT DATA. PULSE Vibration Check System for Aircraft Engines Type 3641 including PULSE Standard Configuration 3560-B-T57

PRODUCT DATA. DC Response Accelerometers Types 4570, 4571, 4572, 4573, 4574, and 4575

PRODUCT DATA. Noise Monitoring Terminals Types 3597 C, 3637 A/B and 3631

APPLICATION NOTE How to Deal with Electrical Noise and Interference in the Measuring Chain using a NEXUS

Automated Frequency Response Measurement with AFG31000, MDO3000 and TekBench Instrument Control Software APPLICATION NOTE

High-voltage Differential Probes TMDP THDP THDP P5200A - P5202A - P5205A - P5210A

PRODUCT DATA. PULSE Reflex Angle Domain Analysis Type Uses and Features

Agilent U1881A and U1882A Power Measurement Application for Agilent InfiniiVision and Infiniium Oscilloscopes

Two-Way Radio Testing with Agilent U8903A Audio Analyzer

PRODUCT DATA. Applications. Uses

PRODUCT DATA. Type channel Human Vibration Front-end Type 1700

Technical Documentation

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide

Process Control Calibration Made Easy with Agilent U1401A

PRODUCT DATA. NEXUS Conditioning Amplifiers for Very High Input Types 2692-C and 2692-D

io n Data Sheet or The P5205 is a 100 MHz Active Differential Probe capable of measuring fast rise times of signals in floating circuits. This 1,300 V

KickStart Instrument Control Software Datasheet

U1881A and U1882A Power Measurement Application for InfiniiVision and Infiniium Oscilloscopes

U1881A and U1882A Power Measurement Application for InfiniiVision and Infiniium Oscilloscopes

Visual Triggering. Technical Brief

High-voltage Differential Probes

R&S ENV216 Two-Line V-Network For disturbance voltage measurements on single-phase EUTs

Getting Started with the LabVIEW DSP Module

30 A AC/DC Current Probe TCP0030A Datasheet

PRODUCT DATA. Sound Intensity Probe Kit Type 3599 including Sound Intensity Microphone Pair Type 4197 and Dual Preamplifier Type 2683

Keysight Technologies Essential Capabilities of EMI Receivers. Application Note

12.5 Gb/s Driver Amplifier LABware Module PSPL8001 Datasheet

Don t Let EMI/EMC Compliance Certification Slow You Down TUTORIAL

Verifying Power Supply Sequencing with an 8-Channel Oscilloscope APPLICATION NOTE

Introduction. Part 1. Introduction...2

Programmable Pulse Generators PSPL10050A, PSPL10060A, PSPL10070A Datasheet

PRODUCT DATA. DIRAC Room Acoustics Software Type 7841

Keysight Technologies How to Take Fast, Simultaneous Measurements of Two or More Signals Using BenchVue Software. Application Note

Keysight Technologies Making Field Effect Transistor Characterization Using SMU

Keysight U1882B Measurement Application for Infiniium Oscilloscopes. Data Sheet

Agilent N8480 Series Thermocouple Power Sensors. Technical Overview

Simplifying DC-DC Converter Characterization using a 2600B System SourceMeter SMU Instrument and MSO/DPO5000 or DPO7000 Series Scope APPLICATION NOTE

Keysight Technologies, Inc. UWB Antenna Measurements with the 20 GHz E5071C ENA Network Analyzer. Application Note

Keysight Technologies How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer.

Keysight Technologies Automated Receiver Sensitivity Measurements Using U8903B. Application Note

12.5 Gb/s PatternPro Programmable Pattern Generator PPG1251 Series Datasheet

Tire Pressure Monitoring Systems and Remote/Passive Keyless Entry

16 Gb/s, 30 Gb/s, and 32 Gb/s PatternPro Pattern Generator PPG1600, PPG3000, and PPG3200 Series Datasheet Notice to EU customers

Keysight Technologies RS-232/UART Protocol Triggering and Decode for Infiniium 9000A and 9000 H-Series Oscilloscopes. Data Sheet

10 GHz Linear Amplifier PSPL5866 Datasheet

Creating Calibrated UWB WiMedia Signals

Passive High Voltage Probes P5100A-TPP0850-P5122-P5150-P6015A Datasheet

Keysight Technologies Measuring Group Delay of Frequency Converters with Embedded Local Oscillators. Application Note

High-impedance Buffer Amplifier System

Keysight Technologies DSOX3PWR/DSOX4PWR/DSOX6PWR Power Measurement Options

QuickSpecs. VIVE Pro VR System with Advantage+ Service Pack. Overview

Basics of Using the NetTek YBA250

Passive High Voltage Probes P5100 P5102 P5120 P6015A

Tektronix Logic Analyzer Probes P6800/P6900 Series Datasheet

Ethernet Transmitter Test Application Software TekExpress 10GBASE-T and NBASE-T Datasheet

Process Control HPP-25

UWB Antenna Measurements with the 20 GHz E5071C ENA Network Analyzer

Introduction. Part 1. Introduction...2

Differential Probes P6248 P6247 P6246 Datasheet

MEMS On-wafer Evaluation in Mass Production Testing At the Earliest Stage is the Key to Lowering Costs

Essential Capabilities of EMI Receivers. Application Note

N9051A Pulse Measurement Software

PRODUCT DATA. Sound Intensity Calibrator Type Uses and Features

Keysight Technologies Using an External Trigger to Generate Pulses with the B2960A

Keysight Technologies N9063A & W9063A Analog Demodulation

N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes

PatternPro Error Detector PED3200 and PED4000 Series Datasheet

Frame through-beam sensors

Keysight Technologies Enhance EMC Testing with Digital IF. Application Note

BNC-2121 Connector Accessory for 660X Devices

Discovering New Techniques of Creating, Editing, and Transferring Arbitrary Waveforms

Product Data. Brüel & Kjær B. Artificial Mastoid Type 4930

TriMode Probe Family P7700 Series TriMode Probes

AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet

Keysight Technologies Making Simpler DC Power Measurements with a Digital Multimeter

SOURCE MEASURE UNITS. Make Multiple Measurements Accurately Using a Single Instrument All While Saving Space, Time and Money

NI 6624 Calibration Procedure

LE160 LE320 Linear Equalizer Datasheet Tektronix Linear Equalizer

Measuring Vgs on Wide Bandgap Semiconductors APPLICATION NOTE

AC/DC Current Probe TCP0150 Datasheet

AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet

A Time-Saving Method for Analyzing Signal Integrity in DDR Memory Buses

Keysight Redefines 50 GHz Portability. Get a $30k Credit When You Move Up to FieldFox

MBR10xCT Series TO-220AB

Data Sheet. Agilent M9185A PXI Isolated D/A Converter. DISCOVER the Alternatives... Agilent MODULAR Products. 8/16-Channel 16-bit, ±16 V

7 Hints That Every Engineer Should Know When Making Power Measurements with Oscilloscopes.

Keysight Technologies Making Current-Voltage Measurement Using SMU

Transcription:

PRODUCT DATA PULSE Multichannel Sound Power Type 7748 Version 1.2 Multichannel Sound Power offers the easiest way yet to measure sound power and other important sound characteristics of products according to the widely used ISO 3744, 7779, and 11201 standards, or according to user-defined settings. Type 7748 controls PULSE, the Multi-analyzer System, making it the first sound power system to offer powerful multichannel and multi-analysis capabilities together in one package. The program is based on an easy-tofollow flowchart that guides you step by step through every part of the measurement process, from setup, calibration and measurement to displaying results and generating reports. Type 7748 also includes advanced batchmeasurement capabilities for saving time and improving the consistency and quality of your results. 7748

Uses and Features USES FEATURES Uses PULSE, the Multi-analyzer System Type 3560 to make multichannel, multi-analysis measurements Determination of sound-pressure-based sound power according to ISO 3744 (1994), the most general and frequently used standard for measuring the sound power of a wide range of products Determination of sound-pressure-based sound power assuming an essentially free field over a reflecting plane but not according to any standard Determination of the directivity index at every measurement surface microphone position Measurement of sound pressure levels and calculation of the impulsive noise index at operator and bystander (workstation) positions according to ISO 7779 (1999) and ISO 11201 (1995) Detection of discrete tones at workstation positions according to ANSI S1.13 (Prominence Ratio) and ISO 7779 (1999) (Tone-to-Noise Ratio) Runs under Microsoft Windows Runs with both Stationary PULSE Type 3560 A and Portable PULSE Type 3560 C Clear and intuitive user interface based on a flowchart that leads you through the initial setup, calibration, measurement, and displaying and reporting of results Advanced batch-measurement capabilities Measurements in single or multiple passes: division into passes occurs automatically according to system resources and channel number license. Manual setup is possible Automatic notification of non-compliance with ISO standards Easy to generate reports in Microsoft Word Easy export of data to Microsoft Excel for further post-processing On-line, context-sensitive Help and User Manual Introduction A combination of increasing legislation and customer pressure is making noise emissions a significant product differentiator. For instance, in the European Union, some EU directives, which set requirements that must be met by certain categories of product sold in the EU, include requirements for declarations of noise emission. Directive 1998/ 37/EC (Machinery Directive), which applies to any machine with moving parts, requires the declaration of sound pressure levels and sound power levels when the sound pressure level exceeds 85 db. Directive 2000/14/EC, which applies to equipment used outdoors (mainly construction and garden equipment), requires declaration of the guaranteed sound power level, measured based on the methods of ISO 3744 (1994). When speaking of product sound measurements driven by customer demands, not only is the sound power level of concern, but also characteristics of the sound field that can cause great discomfort to the human listener, such as audible discrete tones and impulsive noise. Discrete tones are audible sounds of a single frequency; impulsive noise is noise of short duration and relatively high amplitude. 2

Another important parameter that characterises the sound field is directivity, which is defined as the spatial variation of the sound field. A sound field is highly directive if a disproportionately large amount of sound generation occurs in a relatively small area, such as around an exhaust pipe. Multichannel Sound Power is an OLE-based application that interfaces with PULSE, the Multi-analyzer System Type 3560 to use its advanced features to calibrate, measure, display results and generate reports. Flowchart Fig. 1 The Multichannel Sound Power flowchart. The colours for each step indicate the current status. If an error occurs, such as a faulty calibration or a microphone overload, the appropriate status monitors (the diamond shapes on the flowchart) and/ or steps turn red or yellow according to the type of error. You then click the status monitor s Action button for help on any problems encountered The basis of Multichannel Sound Power s Windows interface is a flowchart that is used to set up and execute Type 7748 projects and then generate reports of the results. A Type 7748 Project exists as a working path in which all project data are stored, including setup parameters, environmental corrections, calibration results, background noise measurements, batch-item measurements, and report templates. Below is a description of how the Multichannel Sound Power flowchart leads you from the start to finish of surface and workstation measurements with a number of easy-tofollow steps. Project Setup All setup steps on the flowchart prior to Front-end Setup may be carried out remotely from the computer running PULSE. The first step in the Multichannel Sound Power flowchart is Project Setup. Here you decide whether to measure according to existing standards or your own custom configuration and whether to measure at the measurement surface and/or the workstation positions. All physical parameters for the measurement surface and workstation positions are also configured here. Finally, you can configure a batch list for any number of measurement items that use an identical setup and define the allowed deviation of background noise level and calibration results before and after a batch measurement. Measurement Setup PULSE is a multi-analyzer system, meaning that multiple analysis types such as CPB (i.e., 1/n-octave), FFT, or Overall analysis can be configured and executed simultaneously from the Multichannel Sound Power software. In Measurement Setup, you specify the analysis parameters for the types of measurement to be made. This includes the CPB analysis parameters for the sound pressure measurements that are used to calculate sound power, and FFT and Overall analysis parameters used to determine discrete tones and impulsiveness respectively. 3

Fig. 2 Selecting a hemispherical measurement surface in Multichannel Sound Power. Once you have entered the radius of the hemisphere, simply click on Microphone Coordinates and an illustration (top or side view) appears. You can then choose to view the rectangular and/or spherical coordinates of all surface microphone positions Environmental Corrections Here, environmental correction factors K2 and K3 are entered to account for the influence of the test environment at the measurement surface and specified workstation positions respectively. Environmental corrections can also be imported from other projects. Environmental Corrections OK? If the correction factors exceed the tolerances for the measurement defined in Project Setup, the Environmental Corrections OK? status monitor will turn red to indicate that the correction factors are too high for the selected frequency range. A red indicator does not mean you cannot continue with the measurement, rather it indicates that the measurement made will not be acceptable according to the standard s or user-defined tolerances. Front-end Setup A pass is a part of a measurement in which only some of the microphone positions are measured and/or certain types of analysis carried out. Any measurement configuration can be measured with any PULSE configuration, the only consideration being the number of passes (and therefore time) needed to complete a single measurement. This means that you can acquire an economical, entry-level system to which you can easily add more microphones, input modules and calculation power in the future to speed up measurement time. 4

Fig. 3 Front-end Setup, with a chart for configuring the front-end address and pass information for each microphone position When you reach this step of the flowchart, the PC must be connected to the front-end. In Front-end Setup, you configure the physical connections and conditioning for the microphones on the front-end. Multiple passes can be manually or automatically configured according to the front-end configuration and the number of channels for which your license is valid. After clicking OK, the software will warn you if further serialisation of the measurement is necessary, according to the system resources available. See the specifications for a detailed description of the calculation power required for the specified analysis as a function of the number of channels. Front-end Setup OK? When OK is clicked in Front-end Setup, the software checks PULSE for the selected setup parameters and loads a dedicated PULSE project to ensure that sufficient processing resources are available. If there are no problems, Front-end Setup OK? turns green and you can continue with the next step. If not, it turns red, in which case you can click the Action button to the right to display Help on the specific problem encountered. Calibration Once the measurement parameters and PULSE have been properly set up, the next step is calibration. When making a new calibration, Multichannel Sound Power minimises and PULSE LabShop appears on the screen with the Calibration Master ready to calibrate. Once finished, the gain adjustments and status results appear in a calibration table in Multichannel Sound Power where they can either be accepted or rejected individually. Previous calibrations can also be imported from other projects. Measurements Fig. 4 Measurements offers simplicity and flexibility regardless of your PULSE configuration. The figure shows how status is indicated for measurements throughout Multichannel Sound Power Now you are ready to measure. The Batch List appears and indicates the status for all items. Before measuring, you can autorange the channels on the front-end first for the background noise level and then while the measurement object is operating to find the correct input levels. The first entry on the batch list is always the background noise because measuring it allows the software to adjust the results to obtain the true sound power of the objects (batch items) measured. A background noise measurement can also be imported from another project. To measure, you simply turn on the measurement object, select the correct batch item from the list, select a pass (if more than one) and click Start. Passes can also be set to be measured automatically for individual batch items. Batch items and passes can be measured in any order. In addition, as a time-saver if you have a limited number of microphones, one or more passes can be made on all batch items before changing the microphone positions to measure the other passes. 5

Fig. 5 Real-time measurement display. While measuring, you can select any microphone position(s) and view the real-time progress by clicking Show Monitor. This reduces the size of the Multichannel Sound Power window so that it only fills the lefthand side of the screen and displays PULSE LabShop on the right with realtime graphs for any combination of the microphones being used. As passes are completed, the status is indicated for measurement surface and workstation positions Measurements OK? While measuring, Multichannel Sound Power continuously updates the Batch List with the status of the measurements. Measurements OK? is a more general status monitor that turns red if the background noise level recorded for the batch is too high, or if an overload occurs during measurement. Clicking the Action button to the right provides help on the specific problem encountered. Validation This step allows you to confirm the validity of the background noise measurement and calibration results used for the batch before accepting all the results for the batch of measurements. Say, for example, that you perform the last of ten measurements, recalibrate, and find that one or more of the microphones has a radically different gain adjustment than it did before. The entire batch of measurements should then be repeated until you can get pre-measurement and post-measurement calibration results that are within the allowed gain deviation you have defined for the batch. The same should be followed if if you discover that the background noise level has dramatically changed since starting the batch of measurements. 6

Reporting Fig. 6 Reporting. Multichannel Sound Power provides a vast array of reporting options for any combination of results for individual microphone positions or averaged over the entire surface. Just select which items to report on and click Generate Reports and a report is automatically generated in Microsoft Word In Reporting, you generate reports in Microsoft Word. Whether the measurement surface and workstation measurements are valid or invalid because of, for example, excessive background noise or large environmental corrections, all reporting options are always available. For the entire batch, you can generate reports based on the setup, calibration results and validation information that is of interest. For the individual items, you can generate reports that show measurement results you have selected (as indicated in Fig. 6). Data can also be exported to Microsoft Excel spreadsheets for further post-processing. Results During the measurement process, Multichannel Sound Power generates a set of results that can be viewed in PULSE software using its advanced display features. When you open Results, PULSE LabShop appears on the right side of the screen and displays whatever result types you select for any number of batch items. You can view averaged values for the entire measurement surface, or values for individual measurement surfaces and workstation positions. Again, the status is shown for the selected individual microphones on the measurement surface, the selected workstation positions and the selected batch items as a whole. 7

Fig. 7 Results. This window offers an ideal way to scan results before reporting or to check and compare batch items On-line, Context-sensitive Help Multichannel Sound Power comes equipped with extensive, on-line Help capabilities, including a quick reference to the relevant ISO standards and glossary of terms. Contextsensitive Help is available for every menu item, flowchart step, window, etc., in the program. The Help system includes guided tours that guide you from start to finish through the entire process of giving your product a sound power rating and directivity characteristics, sound pressure level, impulsiveness and discrete-tone rating at workstation positions. Demo projects, complete with measurement data for typical measurements are supplied with Multichannel Sound Power for investigating the software s broad functionality. 8

Specifications Multichannel Sound Power Type 7748, version 1.2 Type 7748 is an application for use with PULSE, the Multianalyzer System Type 3560. Version 1.2 runs with Portable PULSE Type 3560 C provided that PULSE FFT & CPB Analysis Type 7700 is installed SYSTEM REQUIREMENTS The PC requirements for Portable PULSE, Type 3560 C, must be fulfilled PULSE FFT & CPB Analysis Type 7700 (Version 5.2 or later) must be installed SVGA Monitor with 1024 768 resolution (or better) 128MB RAM (or better) Modules Supported Generator, 4/2-ch. Input/Output Module Type 3109 (includes microphone polarization voltage) 6-ch. Input Module Type 3032 A (includes microphone polarization voltage) 6-ch. Input Module Type 3032 B (does not include microphone polarization voltage) Multiple Type 2827 front-end configuration is supported: LAN switch UA 0190 is required Measurement Type 7748 can make a number of different measurements for microphones placed on a measurement surface or located at workstation positions. Measurements can be performed in a single pass or by using multiple passes NUMBER OF MICROPHONE POSITIONS Measurement Surface: 1 to 32 Workstations: 1 to 5 The number of channels allowed for a single-pass measurement depends on the Type 7700 license ANALYSIS Measurement results in Type 7748 are based on CPB, Overall and FFT Analysis. CPB Analysis: Used for calculating Sound Pressure and Sound Power Levels: Filter Bandwidth: 1/1- or 1/3-octave Centre Frequency Range: 16 Hz 20 khz (1/3-octave) 16 Hz 16 khz (1/1-octave) Overall Bands: L and A Acoustic Weighting: L- and A-weighting as post-processing Averaging Mode: Linear Averaging Time: 1 86400 s (24 hours) Overall Analysis: Used for calculating Overall Levels and Impulsiveness: Frequency Span: 1.563 25.6 khz Acoustic Weighting: Linear, A or C Detectors: Linear, Impulse, Peak Averaging Mode: Linear Averaging Time: 1 86400 s (24 hours) FFT Analysis: Used for determining Discrete Tones: Frequency Lines: 50 6400 Frequency Span: 1.56 Hz 25.6 khz Averaging Mode: Linear Number of Averages: 1 100000 Results Type 7748 offers a large number of result types for the measurement surface and at the workstation positions. MEASUREMENT SURFACE Entire Surface: Sound Power Level Sound Pressure Level as measured corrected for background noise and/or measurement environment Background Noise Criteria (compares the measured Sound Pressure Level of the item to the Background Noise) Environmental Correction Factors, K2 Individual Microphone Positions: Sound Pressure Level as measured corrected for background noise and/or measurement environment Background Noise Criteria (compares the measured Sound Pressure Level of the item to the Background Noise) Directivity Index WORKSTATION POSITIONS Sound Pressure Level as measured corrected for background noise and/or measurement environment corrected and averaged over all bystander positions Background Noise Criteria (compares the measured Sound Pressure Level of the item to the Background Noise) Environmental Correction Factors, K3 Overall Level Linear, Impulse or Peak detection L, A or C acoustic weighting Impulsive Noise Index calculated as L pai L pa, L pcpeak L pc according to ISO 7779 (1999) and ISO 11201 (1995) FFT Autospectrum Discrete Tones Tone-to-Noise Ratio according to ISO 7779 (1999) Prominence Ratio according to ANSI S1.13 Reporting Integrated reporting with Microsoft Word 7.0 or later Export of Data to Microsoft Excel 7.0 or later 9

Processing Requirements for Portable PULSE (No. of Beats) The following tables contain specifications for the minimum number of beats a) required for the specified analysis as a function of the number of microphones. See the System Data for Software for Portable PULSE (BU 0229) for a definition of beats and Analysis Engine Measurement Surface: 1/1-octave CPB Analysis Centre Frequency Span (Hz) Number of Microphones 2 4 6 8 9 10 12 16 16k 25 50 75 16 8 k 25 25 50 50 75 75 75 Measurement Surface: 1/3-octave CPB Analysis Centre Frequency Span (Hz) Number of Microphones 2 4 6 8 9 10 12 16 20k 25 50 75 16 16k 25 50 75 16 12.5 k 25 50 75 16 10k 25 25 50 50 75 75 75 Workstations: 1/1-octave CPB Analysis Workstations: FFT * Analysis Centre Frequency Span (Hz) No. of Microphones 1 2 3 4 5 Frequency Span (khz) No. of Microphones 1 2 3 4 5 16 16k 25 25 50 50 75 16 8 k 25 25 25 25 50 Centre Frequency Span (Hz) Workstations: 1/3-octave CPB Analysis No. of Microphones 1 2 3 4 5 16 20k 25 25 50 50 75 16 16k 25 25 50 50 75 16 12.5k 25 25 50 50 75 * 67% overlap 25.6 25 25 25 25 25 Frequency Span (khz) Workstations: FFT * and Overall ** Analysis No. of Microphones 1 2 3 4 5 25.6 25 25 50 50 75 12.8 25 25 25 25 50 * 67% overlap ** Peak detection included 16 10k 25 25 25 25 50 a) Note: A PULSE CPB & FFT AnalyssissType 7700 license enables 50-beat performance (PII 600 MHz is required) A Type 7707 Analysis Engine licenses must be added to upgrade the system to 75 beats (PIII 900 MHz is required) 10

Ordering Information Type 7748-X 1 PULSE Multichannel Sound Power Recommended PULSE Solutions SOLUTION 1: ENTRY LEVEL Type 7700-N2 PULSE FFT & CPB Analysis, 2-ch. license M1-7700-N2 PULSE Annual Software Maintenance and Support Agreement Type 2827 Portable Data Acquisition Unit Type 7533 LAN Interface Module Type 3032 A 6-ch. Input Module PIII 600 MHz PC or better (Windows and Microsoft Office required) Type 3560-C Portable PULSE Acquisition Front-end SOLUTION 2 Type 7700-N8 PULSE FFT & CPB Analysis, 8-ch. license 7700-N8 PULSE Annual Software maintenance and Support Agreement Type 7707-N PULSE Unlimited Analysis Engine 2 Type 2827 Acquisition Front-end 2 Type 7533 LAN Interface Module 2 Type 3032 A 6-ch. Input Module UL 0190 LAN Switch 2 AO 0451 Triaxial Cable (0.2 m) PIII 900 MHz PC or better (Windows and Microsoft Office required) 2 Type 3560-C Portable PULSE Acquisition Front-end 1.X specifies license: N for node locked, F for floating TRADEMARKS Microsoft and Windows are registered trademarks of Microsoft Corporation in the United States and/or other countries Brüel & Kjær reserves the right to change specifications and accessories without notice 11

HEADQUARTERS: DK-2850 Nærum Denmark Telephone: +45 45800500 Fax: +45 45801405 bksv.com info@bksv.com Australia (+61) 2 9889-8888 Austria (+43) 1 865 74 00 Brazil (+55)11 5188-8166 Canada (+1) 514 695-8225 China (+86) 10680 29906 Czech Republic (+420) 267021100 Finland (+358) 9-755 950 France (+33) 169 907100 Germany (+49) 421 17 87 0 Hong Kong (+852) 2548 7486 Hungary (+36) 1 215 83 05 Ireland (+353) 1 807 4083 Italy (+39) 0257 68061 Japan (+81) 3 3779 8671 Republic of Korea (+82) 2 3473 0605 Netherlands (+31)318 55 9290 Norway (+47) 66 77 11 55 Poland (+48) 22 816 75 56 Portugal (+351) 21 47 11 4 53 Singapore (+65) 377 4512 Slovak Republic (+421) 25 4430701 Spain (+34) 916590820 Sweden (+46) 84498600 Switzerland (+41) 18807035 Taiwan (+886) 22 713 9303 United Kingdom (+44) 14 38 739 000 USA (+1) 800 332 2040 Local representatives and service organisations worldwide BP 1751 13 03/08