NFPA 1901 Lighting Applications Guide

Similar documents
CHAPTER VII ELECTRIC LIGHTING

APPENDIX GLOSSARY OF TERMS

Use timers, motion detectors, remote controls, and photocells to reduce waste.

Lesson 1 - Cookies. You will use the cookie by placing it in front of the flashlight to create a shape of light on the wall.

Lighting for seniors

Northwest façade of building

Lumen Method Calculation Assignments Due: Tuesday, November 28, 9:00am

GUIDELINES FOR GOOD EXTERIOR LIGHTING PLANS

LED Lighting. For COLD STORAGE and WAREHOUSING

1.4 Rollins Center Performance Hall

daylight Spring 2014 College of Architecture, Texas Tech University 1

Community Design Standards

DOUGLAS COUNTY ZONING RESOLUTION Section 30 Lighting Standards 3/10/99. -Section Contents-

EXTERIOR LIGHTING DESIGN

NOT SO SCARY LIGHTING MATH

15 Million Candlepower Handheld Spotlight - 35 Watt HID Lumens - Spot / Flood Combo

CHAPTER 18 Lighting Regulations

Tove. High Performance Linear System Wall Mounted

PAYBACK STARTS NOW INDUSTRIAL LIGHTING PRODUCT CATALOG

General Information 11A-1. A. General. B. Industry Outlook. Design Manual Chapter 11 - Street Lighting 11A - General Information

TECHNOLOGY INFORMATION SHEET

Energy and Calculating Light. Lighting Needs Power: Electrical Systems. Lighting Needs Power: Wires Distribute Electricity

NOT SO SCARY LIGHTING MATH

HOME SCIENCE CHAPTER 3: LIGHTING IN THE HOME Class: X

INDEPENDENCE VISITOR CENTER PHILADELPHIA, PA

REVISIONS Summary of Change. 6/1/12 All Replaced entire document with new revision

An Introduction to Interior Lighting Design

Turtle Friendly Lighting: Technical Advice Note

CELESTIAL CORONA LOW VOLTAGE LINEAR LIGHTING

APPENDIX IV.A.3 Technical Memo Summarizing and Analyzing Illustrative Athletic Field Lighting Plan (January 2010)

Chapter 24 Outdoor Lighting Ordinance

Light In Architecture

Here is a glossary of terms about Lighting that is great knowledge to understand when growing cannabis, whether indoors our outside in a greenhouse.

NOT SO SCARY LIGHTING MATH NOT SO SCARY LIGHTING MATH

A. Title Article XXXXV together with the amendments thereto, shall be known and may be cited as the Town of Riverhead Lighting Ordinance.

American National Standard

CMGT 352 Electrical Estimating Discussion #03 Commercial Building Electrical Systems Lighting. Lighting Terminology

Optimizing Machine Tool Lighting

Section 27.5 Outdoor Lighting

1000 Watt Metal Halide Light - Hot Restrike - Multi-tap Ballast - Spot or Flood

Light layering involves using several types of light in one room to serve different purposes. The basic layers are: 1 Ambient lighting 2 Task

FWC SEA TURTLE LIGHTING GUIDELINES

Evaluation of High Intensity Discharge Automotive Forward Lighting

December 29, 2016 Page 1

LdG-2 Lighting design Guide for Vertical Surfaces


CITY of ALBUQUERQUE SIXTEENTH COUNCIL

Lux-Ray LED Series Low-profile, sleek look light fixture NEMA-3R

4000 Watt - Metal Halide - Three Stage Light Tower - 30 Feet

Lighting Terminologies Introduction

7 Million Candlepower Handheld Spotlight Watt Halogen - Spot & Flood Combo - 12V Spotlight

The Quality of Light TM. LineLight. Metaphase Technologies Inc. LL040710

LED SERIES SPECTACOLOUR FLOOD RGB SPECTACOLOUR FLOOD RGB

spacing, efficiency, uniformity, and aesthetic appearance of light patterns for final design for the construction document phase.

Project: EIR for Carondelet High School Sports Complex

STAR POWER TM REFLECTOR MADE IN THE U.S.A.

LED Recessed Lighting

HBL Series High Bay LED

Lighting Terminology Wolf Lake Drive, suite 105, Bartlett, TN O F

BEACON TM PROJECT: TYPE: BSL PSU

Shade and Shadow. Lights Dark Brother. Lighting Design is Shade and Shadow. Light and Shadow a unity.

Indoor Lighting Product Catalogue. We brighten up your life

Lesson: Lighting Levels & De- Lamping Assessment

Project Details: average average footcandles,

Where to Consider Photocontrol for Inside Lighting

Calculite White LED 4 " Adjustable Accent. Professional-grade downlighting

NEW. Lumenfacade Remote. Lumenfacade Stand. Alone NEW NEW. Lumenfacade Remote. LumenfacadeFX RGB. Lumenfacade. Lumenfacade Interior RGB RGB RGB NEW

Guidance Material for ILS requirements in RSA

POST TOP FIXTURE C40T

VG Series LED Parking Structure Luminaire

The Bahen Centre for Information Technology. Lecture Hall Lighting Redesign. Introduction. University of Toronto ~ Toronto, Ontario, Canada

OUTDOOR TRACK (PATENT PENDING)

CS 178 Digital Photography Professor Marc Levoy Stanford University Spring 2011

Space #2: Science Room 1

LM Test Report. for Elec-Tech International Co.,Ltd. LED PAR30 Spot light Model: XX(XX:41-50)

FIXTURE INTEGRATED DAYLIGHT DIMMING PHOTOSENSOR

ARTICLE VIII B OUTDOOR LIGHTING

Basic Lighting Design Seminar

ARCH 3/431 Spring

E LED Lighting BV & Inc. European Office: Tel: +31 (0) , Fax +31 (0) , E mail LEDLighting.com United States Office:

GIOTTO MK2 Quartz Halogen Top Cyclorama Lights

Lighting Design. Debra A. Kennaugh, P.E. Lighting Design by Debra A. Kennaugh, P.E. A SunCam online continuing education course

LIT-2. Lighting Philosophy

UFGS-16553N (Septermber 1999) UNIFIED FACILITIES GUIDE SPECIFICATIONS

Electroluminescent Lighting Applications

Physics of Light. Light: electromagnetic radiation that can produce a visual sensation.

Ronald Reagan Presidential Library. Reagan Country Café

Evolution LED 3 " Calculite Professional-grade downlighting

Super LED F10 HPrp. Led Power 330W PFC 0,96

Maryland SHA LED Lighting. Brian Grandizio PE / Amol Ranade EIT

NOT SO SCARY LIGHTING MATH

The Soft Celiling Luminaire.

D-Series VC. Area Lighting. Outdoor. Outdoor

LUM-TECH LED Housing Architectural Downlight CONCENTRA. Architectural. Downlight

Exhibit Space & Booth Layout Guidelines

soft vue 15 Like Us On:

HID PAR Series. Source Four 150W HID PAR. Connector Designation Use Suffixes below to specify Factory Fitted Connector type

Energy Efficient Lighting

LA DOTD s Nighttime Standards for Construction Operations. Presented by: Tom Ervin Traffic Solutions, Inc.

PAR30S GU W OUTPUT RANGE: VIVID SERIES OUTPUT RANGE: BRILLIANT SERIES COLOR TEMPERATURE RANGE

Transcription:

NFPA 1901 Lighting Applications Guide NFPA Lighting Requirements... -5 Example Vehicles Lighting Terms... 8 Pumper..., 4-5 Summary... 8 Aerial...3, 6-7 The NFPA 1901 standard was revised in 009 and new illumination requirements added for several applications. This guide assists you with installing Havis fixtures to meet these requirements. Havis also provides recommendations for optimal illumination for many applications. To learn more, please contact us at 800-54-9900 or at NFPA@havis.com. www.havis.com 1-800-54-9900

NFPA 1901: Work Perimeter Scene Lighting The goal of any lighting application is to provide the right amount of light to allow emergency responders to perform their jobs as safely as possible. NFPA 1901 identifies specific areas where lighting must be provided. Below are recommendations regarding each requirement: Work area lighting (Section 13.10.1.1): 3 fc at 10 x 10 area behind vehicle. Any Havis Magnafire or Kwik-Strike fixture in any configuration will meet this requirement, so long as the installed height is at least 6 above the ground and the fixture is aimed suitably. Although it is technically possible to meet this requirement with the KR-CCL Series fixture, it is not recommended since it will only illuminate the ground, and not provide useful work lighting to emergency responders. Note that 3 fc is a relatively low illumination level, and is best suited for egress lighting. We recommend increasing the illumination level to at least 5 fc for general-purpose illumination, or 10 fc for working (e.g. operating equipment.) Magnafire fixtures with either HID lamps or 750W and above halogen lamps are optimal for this application. Perimeter lighting (Section 13.10.1.): fc up to 30 from vehicle. Only egress illumination is required, then the optimal solution is to space KR-CCL Series fixtures at regular intervals. Recommended linear spacing is 84 at a mounting height of 0. Recommended linear spacing is 108 at a mounting height of 30. If additional lighting is needed, such as areas where equipment will be taken out of compartments, the Kwik-Strike 4000 Series can also provide effective perimeter lighting to an area of about 0 x 0 when mounted at about 8 above the ground. Hose Bed Lighting (Section 13.10..1): 3 fc For strict adherence to the requirement, uniform diffuse illumination will be required, and the KR-CCL Series fixture spaced at regular intervals will provide optimal results. Recommended linear spacing of KR-CCL Series fixtures is 84 at a mounting height of 30. Hosebeds of 36 width or narrower will require only one row of lighting. Hosebeds of 36 to 96 wide should include two rows of lighting. Illuminating a hosebed is definitely recommended good practice, and 3 fc is reasonable for uniform diffuse illumination. If strict adherence to the NFPA is not necessary, then a single floodlight can be used. Any Havis Magnafire or FX flood fixture will work acceptably. However, if the illumination is not uniformly diffused, then we would recommend increasing the average illumination level to at least 5 fc. Perimeter Lighting Areas within 30 of vehicle fc minimum Per Section 13.10.1. Hose Bed Lighting Entire Area 3 fc minimum Per Section 13.10..1 Work Area Lighting 10 ft x 10 ft at vehicle rear 3 fc minimum Per Section 13.10.1.1 www.havis.com 1-800-54-9900

Gauge and Control Lighting All exterior control panels 5 fc minimum Per Section 4.10.1.1 and 16.9. Gauge and control lighting (Sections 4.10.1.1 and 16.9.): 5 fc on controls. The KR-CCL provides optimal lighting quality from a diffused source, so it is recommended to use the KR-CCL at spaced intervals for best illumination effect. Recommended spacing for KR-CCL fixtures mounted directly against a control panel is 34 side-to-side by 56 top-to-bottom. Due to the irregular shape of gauges and controls, KR-CCL fixtures should be offset from the control panel surface whenever possible. The spacings above can be increased by 5% per inch offset from the surface, up to 10 maximum offset. Please note that the NFPA recommended illumination level is reasonable, but may be higher than necessary in some applications. If the surrounding scene is brightly lit and glare may be an issue, then the NFPA-recommended 5 fc level is sufficient. For most applications, fc is adequate, and will reduce the number of fixtures required by about half. Back-lighted gauges are recommended regardless of what illumination level is provided by gauge and control lighting. Water stream lighting (Section 19.18.6): 75,000 cp spot or 10,500 lm flood. All Havis spotlights meet this minimum requirement, including all CD-FX spotlights. Magnafire 3000 and 5000 Series floodlights equipped with 10,500 lm lamps and higher will meet the requirement. This includes 500W halogen and above, and 150W Metal Halide HID. We recommend that every fixture include a lamp rated to at least 1,500 lumens for most applications, and at least 3,000 lumens for lights used at the tips of aerials. In addition to that, we recommend using spot lights with at least a 00,000 cp beam for most applications, and at least 400,000 cp for lights at the tips of aerials. All Havis FX fixtures with spot reflectors will meet the higher recommended illumination level. Note that the CD-FX-HID-1 fixture will provide 50% better light quality and visibility compared to other lights, since it is HID. Water Stream Lighting Spot: 75,000 cp minimum or Flood: 10,500 lm minimum Per Section 19.18.6 www.havis.com 1-800-54-9900 3

Surface lighting (Section 13.10.3): fc on all surfaces. A single KR-CCL Series fixture will illuminate a 30 x 30 x 108 area to at least fc, and will provide excellent diffused illumination. It is good practice to illuminate surfaces, and fc is reasonable for diffuse illumination. If other (non-diffused) light sources, such as floodlights, are used for this application, then we would recommend increasing the illumination level. The maximum should not exceed 10 fc and the minimum should not be less than 3 fc. Interior lighting (Section 13.10.4): Average of fc at seating area. A single KR-CCL Series fixture will illuminate a surface up to 45 below to fc. A KR-DL fixture can be used in the same application with one lamp lit and a clear lens installed. For reading, we recommend supplemental illumination to at least 5 fc by using additional fixtures over the reading areas, or by installing C-MAP maplights at reading areas. The KR-DL is very useful for over-seat lighting, as it already has two lamps, so one lamp can be used to meet egress requirements, while both lamps can be used when needed for reading. Interior Lighting All interior crew areas fc minimum at seating area Per Section 13.10.4 Surface Lighting All exterior surfaces fc minimum Per Section 13.10.3 4 www.havis.com 1-800-54-9900

Compartment lighting (Section 13.10.5.1): fc on the floor. The NFPA recommendation is inadequate, because it ignores the importance of using diffused light sources, it does not address the fact that lighting must be on each shelf, and the illumination level recommended should be higher for adequate visibility. In order to provide adequate illumination while also meeting the standard, KR-CCL Series fixtures can be installed and spaced suitably. In order to compute the number of fixtures needed, measure the size of the compartment (L x W) and add them together in feet. Use one KR-CCL Series for every 8 measured. Round to the nearest whole number. For compartments, add one additional light for every 10 measured. For example, a x 4 standard compartment needs one light, and 8 x 4 needs two lights. The calculation above assumes an empty compartment with no shelves. For proper visibility, one light is recommended for each full-compartment shelf installed. This does not necessarily mean additional lights are needed; it only means that the lights should be positioned so that at least one light illuminates each shelf. If there are more shelves than lights, then additional lights would be needed. It is best to space the KR-CCL Series so that half of the light is above one shelf, and the other half is below, and to light each shelf from both sides. For adequate illumination in a compartment that is at least 30% full, a minimum of 5 fc of illumination should be provided on most surfaces. In order to meet the recommended 5 fc level, add one additional KR-CCL Series fixture for every 8 measured using the calculation above. Compartment Lighting All floor areas fc minimum Per Section 13.10.5.1 www.havis.com 1-800-54-9900 5

1 1 1 In-Wall/Perimeter Lighting Water Stream/Aerial Tip Lighting 3 Poles KR-4xxx KR-15xx/5xx KR-18xx/6xx KR-19xx/7xx KR-1xx/8xx KR-xx/9xx KR-3xx/31xx Spotlights: CD-FX-1 CD-FX-HID-1 Floodlights: KR-SB-6xx KR-13xx KR-14xx KR-SB-100 KR-SB-00 KR-SB-300 KR-SB-400 KR-SB-500 KR-SB-800-TM KR-SB-1100 KR-SB-100 5 1 3 6 www.havis.com 1-800-54-9900

4 4 4 4 4 4 xx = Lightheads Available Magnafire 3000 Series 4 Perimeter/Scene Lighting Fixed Mounts: KR-SB-6xx KR-13xx KR-14xx KR-35xx KR-36xx 5 Interior Lighting KR-DL, KR-CCL-x-WP Perimeter Lighting KR-CCL-x-WP 31 70W, 1-4VDC, HID 3 150W, 1-4VDC, 33 350W, 10VAC, HAL 36 750W, 10VAC, HAL 37 750W, 0VAC, HAL 39 900W, 40VAC, Magnafire 5000 Series 51 70W, 1-4VDC, HID 53 350W, 10VAC, HAL 55 500W, 10VAC, HAL 56 750W, 10VAC, HAL 57 750W, 0VAC, HAL 4 4 5 5 www.havis.com 1-800-54-9900 7

Lighting Terms It is important to understand some basic lighting principles while explaining how to use them in this manual. These are some key definitions: Footcandle (fc): This is a level of light on a surface, such as the ground. Below are some examples of what illumination levels are needed for various applications: fc: Enough light to walk safely without tripping (egress) in most circumstances. 5 fc: Enough light to read while sitting or standing still, or perform very basic tasks. 10 fc: Enough light to operate most equipment. 30 fc: Minimum required for typical office-type work. 70 fc: Minimum required for intricate or complex tasks. Note that footcandle levels are not perceived by the human eye in a linear manner. In other words, fc is not necessarily perceived by the human eye to be twice as bright as 1 fc. Lumen (lm): This is a quantity of light, defined at a specific wavelength (color.) This defines how much light is present, although it does not say anything about how well the human eye can actually see the light. A lumen rating also does not indicate how much light will be provided on the ground at any particular location, nor does it indicate the intensity of the light at any location. Candlepower (cp): This is an intensity of light in one direction. Candlepower ratings are only applicable to spot fixtures, and must be used in conjunction with lumen and other ratings to determine if the fixture will produce enough light as well as enough intensity. Key concept: Light quality is just as important as light quantity. Having a large quantity of light is only good if your eyes can actually see the light. Metal Halide HID and CCFL fixtures are capable of producing much higher quality light than halogen/incandescent and some LED fixtures. All Havis fixtures are optimized for maximum visibility, and all recommendations contained herein take that into consideration. If using a competitor s fixture, please note that higher illumination levels may be required in order to achieve the same visibility. For a detailed explanation of lighting technologies and human vision, please visit the Havis website (www.havis.com). Summary This technical bulletin is intended to assist fire departments and vehicle manufacturers with installing Havis fixtures. It is also intended to provide recommendations and guidelines for good illumination in many applications. However, it is not possible to cover every possible installation application, so these guidelines must be considered as reference information only. It is solely the installer s responsibility to ensure that lighting levels are adequate, and if requested by the customer, that all NFPA requirements are met for each application. If any additional assistance is required with a specific application, please contact your local sales representative. For more information, contact NFPA@havis.com. 8 www.havis.com 1-800-54-9900 NFPA-1091_NPR_1-10