AUTOMOTIVE CURRENT SENSOR DHAB S/18. Datasheet

Similar documents
AUTOMOTIVE CURRENT SENSOR DHAB S/25. Datasheet

AUTOMOTIVE CURRENT TRANSDUCER DHAB S/15

AUTOMOTIVE CURRENT SENSOR HC6H300-S

AUTOMOTIVE CURRENT TRANSDUCER HC6H1000-S

AUTOMOTIVE CURRENT SENSOR HC6H500-S. Datasheet

AUTOMOTIVE CURRENT TRANSDUCER HC6F600-S

HC2F100-SN CLIPS AUTOMOTIVE CURRENT TRANSDUCER HC2F100-SN CLIPS. Datasheet

AUTOMOTIVE CURRENT TRANSDUCER HC6F700-S

AUTOMOTIVE CURRENT TRANSDUCER HC2F100-SN CLIPS

AUTOMOTIVE CURRENT TRANSDUCER HAH1DR 300-S

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY DHAB S/157

AUTOMOTIVE CURRENT TRANSDUCER HAH3DR 700-S02

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY DHAB S/124

AUTOMOTIVE CURRENT TRANSDUCER HAH3DR 700-S00

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1DR 200-S

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1DRW 300-S

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HSW S01

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH3DR 1100-S07

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH3DR 800-S03/SP2

AUTOMOTIVE CURRENT TRANSDUCERS OPEN LOOP TECHNOLOGY

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH3DR 800-S0C

AUTOMOTIVE CURRENT TRANSDUCER HAB 60-S/SP5

Current Sensor: ACS750xCA-100

Current Sensor: ACS752SCA-050

Current Sensor: ACS750xCA-050

Current Sensor: ACS755SCB-200

AUTOMOTIVE CURRENT TRANSDUCER FLUXGATE TECHNOLOGY CAB 300-C/SP3-XXX

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Current Transducer CTSR 1-P = 1A

Current transducer FHS 40-P/SP600

Current Sensor: ACS754SCB-200

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

Limited Availability Product

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

Current Sensor: ACS754xCB-100

Last Time Buy. Deadline for receipt of LAST TIME BUY orders: May 1, 2008.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

Typical Application C BYP C F 3 R F

Discontinued Product

HO 50-S/SP30, HO 100-S/SP30, HO 150-S/SP30, HO 200-S/SP30, HO 250-S/SP30 and HO 200-S/SP31

For the electronic measurement of current: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit.

Typical Application VCC IP+ ACS755 GND C F 3 R F

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

Ref: HO 50-S/SP33, HO 100-S/SP33, HO 150-S/SP33, HO 200-S/SP33, HO 250-S/SP33

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

I PN. Ref: HO 50-S, HO 100-S, HO 150-S, HO 200-S, HO 240-S, HO 250-S

Ref: HLSR 10-P/SP3, HLSR 20-P/SP3, HLSR 40-P/SP3, HLSR 50-P/SP3

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

AUTOMOTIVE CURRENT TRANSDUCER CAB 300-C/SP2

Typical Application VCC IP+ ACS755 GND C F 3 R F

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Ref: HLSR 10-SM, HLSR 16-SM, HLSR 20-SM, HLSR 32-SM, HLSR 40-SM, HLSR 50-SM

Ref: HLSR 10-SM/SP33, HLSR 20-SM/SP33, HLSR 32-SM/SP33, HLSR 40-P/SP33, HLSR 50-SM/SP33

= 1000 V. Voltage transducer DVC 1000-P V P N

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

I PM. Current Transducer ITZ 5000-SB FLEX ULTRASTAB = 5000 A

CPCO Series (160mm) DC-AC Current Probe, Clamp On ±4000A, ±8000A, ±12000A,

V P N. Voltage transducer DVM 2000-B = 2000 V

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Voltage transducer DVL 50

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Current transducer FHS 40-P/SP600

Data Sheet. Hall effect transducers, current and voltage

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Unipolar voltage - Current output 4-20 ma Ref: DVL 50-UI, DVL 150-UI, DVL 250-UI, DVL 500-UI, DVL 750-UI, DVL 1000-UI, DVL 1500-UI

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

= 600 V. Voltage transducer DVM 600 V PN

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

High Performance Current Transducer ITL 900-T = A

Linear Current Sensor with differential outputs

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and secondary circuit.

I P. /dt. di p V S+ Applications. Standards. 1) IEC ed1.0: 2007; IEC : ed1.0: 2012

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

CPCO Series DC-AC Current Probe, Clamp On, 160mm, ±1000A ±2000A ±4000A ±8000A ±12000A, ±16000A

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit.

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit.

I P. /dt. di p V S Applications. Standards 1) IEC : 2007; IEC : ) IEC : 2016; IEC : 2017

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

DS2000ICLA. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Low Cost 100 g Single Axis Accelerometer with Analog Output ADXL190*

V P N. Voltage transducer DVM 4200 = 4200 V

Series AM50E-NZ 50 Watt DC-DC Converter

DL2000ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.

DQ600ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1 ppm. MPS for particles accelerators

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit.

AC/DC current clamps (1/2) E N series

Transcription:

AUTOMOTIVE CURRENT SENSOR DHAB S/18 Datasheet 070720/1 Page 1/6

Introduction The DHAB family is best suited for DC, AC or pulse current measurement in high power and low voltage automotive applications. It s contains a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). The DHAB family has a dual current range. It gives you the choice of having different peak currents (from +/- 20A up to +/- 600A) in the same housing. Features Open loop transducer using the Hall effect sensor Low voltage application Unipolar +5VDC power supply Primary current measuring range up to ± 100A for range 1 and +/- 600A for range 2 Maximum rms primary admissible current: defined by primary cable to have T < +150 C Operating temperature range: - 40 C < T < +125 C Output voltage: fully ratio-metric (gain and offset) 2 measuring ranges to have a better accuracy. Principle of the DHAB Family The open loop transducers use an Hall effect IC. The magnetic induction B, contributing to the rise of the Hall voltage, is generated by the primary current I p to be measured. The control current I p is supplied by a current source i.e. battery or generator (Fig. 1). Within the linear region of the hysteresis cycle, B is proportional to: I P (B) = constant (a) x I P The Hall voltage is thus expressed by: V H = (K/d) x I x constant (a) x I P Except for I P, all terms of this equation are constant. Therefore: V H = constant (b) x I P The measurement signal V H amplified to supply the user output voltage or current. Advantages Good accuracy for high and low current range Good linearity Low thermal offset drift Low thermal gain drift Hermetic package. Automotive applications VH Battery Pack Monitoring Hybrid Vehicles EV and Utility Vehicles. Primary current Ip Isolated output voltage Fig. 1: Principle of the open loop transducer 0707120/1 Page 2/6

Dimensions DHAB S/18 (in mm. 1mm = 0.0394 inch) System Architecture LEM - DHAB sensor + 5V V C Typical application Schematic interface + 5V 100 nf 47 nf I P Channel 1 R Primary current 10 nf C LOAD R LOAD C Channel 2 R 10 nf C LOAD R LOAD C Bill of materials Plastic case Pins Magnetic core Mass PA 66-GF25 Brass tin platted Channel 1: FeNi alloy Channel 2: FeSi alloy 69.5 g R LOAD C LOAD RC > 10 kω Optional resistor for signal line diagnostic < 100 nf EMC protection low pass filter EMC protection (optinal) Page 3/6 070720/1

Absolute maximum rating (not operating) PARAMETER Symbol Unit Supply continuous over voltage V 8.5 Supply over voltage V 14 1 min Reverse voltage V -14 1 min @ T A = 25 C Output continuous over voltage V 8.5 Output over voltage V 14 1 min @ T A = 25 C Continuous output current I out ma -10 10 Output short circuit duration t c min 2 Storage temperature T S C -40 125 Operating conditions Channel 1 Channel 2 0707120/1 DHAB S/18 PARAMETER Symbol Unit Supply voltage V C V 4.75 5 5.25 Current consumption I C ma 15.00 20 Power up inrush current ma 40 @ V C < 3.5 volts Continuous output current I out ma -1 1 Load resistance R L KΩ 10 Load capacitor C L nf 1 100 Ambient operating temperature PARAMETER T A PARAMETER Symbol Unit Primary current, measuring range I Pchannel 2 A -350 350 Offset voltage 1) V o V 2.50 @ V C 5 volts Sensitivity 1) G mv/a 5.7 @ V C 5 volts Load resistance R L mv 2.5 @ V C 5 volts Clamp low 1) V 0.24 0.25 0.26 @ V C 5 volts Clamp high 1) V 4.74 4.75 4.76 @ V C 5 volts Output internal resistance R OUT Ω 1 10 Frequency bandwidth BW KHz 1 @ -3 db Power up time ms 110 Setting time after over load ms 25 Note: 1) The output voltage V out is fully ratio-metric (that concerns V O, Sensitivity ans clamping), it depends on the supply voltage V C in relative with the following formula: Ip C -10 65 High accuracy -40 125 Reduced accuracy Symbol Unit Primary current, measuring range I Pchannel 1 A -30 30 Offset voltage 1) V o V 2.50 @ V C 5 volts Sensitivity 1) G mv/a 66.7 @ V C 5 volts Load resistance R L mv 2.5 @ V C 5 volts Clamp low 1) V 0.24 0.25 0.26 @ V C 5 volts Clamp high 1) V 4.74 4.75 4.76 @ V C 5 volts Output internal resistance R OUT Ω 1 10 Frequency bandwidth BW KHz 1 @ -3 db Power up time ms 110 Setting time after over load ms 25 Vc 1 5 Vout * * 2 G Vc = x x With G in (V/A) Page 4/6

Accuracy Channel 1 PARAMETER Symbol Unit Electrical offset current I OEchannel1 ma ±50 @ T A = 25 C Residual current I OMchannel1 ma ±50 @ T A = 25 C Global offset current I Ochannel1 Sensitivity error ε G % ma ±100 @ T A = 25 C -300 300 @ - 10 C < T < 65 C -500 500 @ - 40 C < T < 125 C ±0.5 @ T A = 25 C -2.5 2.5 @ - 10 C < T < 65 C -4 4 @ - 40 C < T < 125 C Linearity error ε L % -1 1 of full range Channel 2 PARAMETER Electrical offset current I OEchannel2 A ±0.7 @ T A = 25 C Residual current I OMchannel2 A ±2.3 @ T A = 25 C Global offset current Symbol I Ochannel2 Unit Sensitivity error ε G % A ±3 @ T A = 25 C -4 4 @ - 10 C < T < 65 C -4.5 4.5 @ - 40 C < T < 125 C ±0.5 @ T A = 25 C -2.5 2.5 @ - 10 C < T < 65 C -4 4 @ - 40 C < T < 125 C Linearity error ε L % -1 1 of full range Note: In case of short circuit of any DHAB output to + batt, a current is reinjected in the power supply. If the output voltage is not protected against this current, this voltage may increase or decrease, which must be taken into account for the second channel. 070720/1 Page 5/6

PERFORMANCE PARAMETERS DEFINITIONS Sensitivity: The Transducer's sensitivity G is the slope of the straight line V out = f (I P ), it must establish the relation: V out (I P ) = V C /5 (G x I P + 2.5) (*) (*) For all symetrics transducers. Output voltage: It's the output voltage when the primary current is null. The ideal value of V O is V C /2. So, the difference of V O - V C /2 is called the total offset voltage error. This offset error can be attributed to the electrical offset (due to the resolution of the ASIC quiescent voltage trimming), the magnetic offset, the thermal drift and the thermal hysteresis. Magnetic offset: The magnetic offset is the consequence of an over-current on the primary side. It's defined after an excursion of I Pmaxi. Linearity: The maximum positive or negative discrepancy with a reference straight line V OUT = f (I P ). Unit: linearity [%] expressed with full scale of I Pmaxi. Reference straight line Response time (delay time) t r : The time between the primary current signal and the output signal reach at 90 % of its final value I [A] V out Non linearity example Max. linearity error Linearity variation in IN % IN Ip Output noise voltage: The output voltage noise is the result of the noise floor of the Hall elements and the linear I C amplifier sensitivity. Offset drift: The error of the offset in the operating temperature εoffset is the relative variation of the offset in the temperature considered with the initial offset at 25 C. The offset temperature coefficient TCV OE (TCI OE ) in the operating temperature is the slope off εoffset = f (T). Sensitivity drift: The error of the sensitivity in the operating temperature Sensitivity Error is the relative variation of the sensitivity in the temperature considered with the initial sensitivity at 25 C. Sensitivity temperature coefficient TCe G. Typical: Theorical value or usual accuracy recorded during the production. Environmental test specifications Low T storage Deviation of the typical global accuracy after the environmental tests: NAME STANDARD CONDITIONS Thermal shocks IEC 60068 Part 2-14 Low T operation at mini supply voltage Hight T operation at maxi supply voltage Temperature humidity bias Mechanical Tests Vibration IEC 60068 Part 2-2 IEC 60068 Part 2-3 Drop test IEC 60068 Part 2-29 EMC Test Rms voltage for AC isolation test Bulk current injectedradiated immunity Electrostatic discharge ISO11452-4 T - 40 C to 120 C /300 cycles not connected T - 40 C / 1000 H supply voltage = 4.75 V T 125 C / 1000 H supply voltage = 5.25 V T 90 C / 95 % RH/ 1000 H supply voltage = 5.25 V Acceleration 30m/s2, 25 C, frequency 20 to 1000 Hz/8h each axis Drop 1m, 2 falls/part, 1part/axis, 3axes, criteria : relative sensitivity error 3% 90 % Ip Is @ I P = 0 A @ ± I P T A = 25 C (-) 40 C < T < 125 C tr 10 % tra t[µs] 0707120/1 Page 6/6