A compact, integrated solution for medium voltage connection, transformer and low voltage distribution

Similar documents
Circuit Breakers FAZ / FAZ6. Installation Products for Industrial Applications

Installation Manual. Arc Chamber

Gas-Insulated Medium-Voltage Switchgear siemens.com/8dab12

Advanced Test Equipment Rentals ATEC (2832) CP RC. Resonance circuit for GIS testing

For Medium Voltage Motors, Generators, Switchgear, Bus Duct and Cable Terminations

Low voltage switchgear

Onsite Mobile AC High Voltage Test System

Medium-voltage in-phase regulator system Energy Management

ZS8.4 Air-insulated medium voltage switchgear

Fluid Technology Automation Technology smart buildings Technology

Power Voltage Transformers for Air Insulated Substations. THE PROVEN POWER.

Your passport to success TECHNICAL OVERVIEW

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Compact Substation or Prefabricated Substation Inside Totally Enclosed Weatherproof Enclosure COPYRIGHT REGISTERED

Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations

MEDIUM VOLTAGE COMPACT STARTER TYPE KAE

How to maximize reliability using an alternative distribution system for critical loads

THE TRANSFORMER PEOPLE FOR LIFE. Wilson Transformer Company COMPANY PROFILE. wtc.com.au

VACUTAP VVS COMPACT ON-LOAD TAP-CHANGER FOR GRID APPLICATIONS.

(

Instrument transformers for indoor applications. Product overview. Instrument transformers for indoor applications.

COMPONENTS. Power contactor Type BMS09.08 / BMS18.08

VI 3 - i TABLE OF CONTENTS

IRIS POWER PDTracII. Continuous On-line Partial Discharge Monitoring for Motors, Generators, Dry Type Transformers, and Air-Insulated Switchgear.

More flexibility for the manufacturing industry

Three-phase short-circuit current (Isc) calculation at any point within a LV installation using impedance method

Switchgear Type SIMOSEC up to 24 kv, Air-insulated, Extendable

PRODUCT PORTFOLIO TEST AND MEASURING SYSTEMS

Efacec work every day to anticipate solutions for a sustainable world in the new energy era.

INTEGRATED TRANSMISSION PLAN Glossary

PAPER. Dry-type transformer innovation: HiDry 72 for subtransmission lines

Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated

VOLUME - 4 (GENERAL TECHNICAL SPECIFICATIONS)

FLOOR TYPE MILLING-BORING CENTRE

IRIS POWER PDTracII. Continuous On-line Partial Discharge Monitoring for Motors, Generators, Dry Type Transformers, and Air-Insulated Switchgear.

La protection sélective des réseaux électriques

DESIGN STANDARD NO. DS 21

Neutral Earthing. For permanent or temporary neutral earthing in HV systems

High voltage shunt capacitor banks HIGH VOLTAGE COMPENSATION AND HARMONIC FILTERING PRODUCTS

AN EXAMPLE OF A STANDARD ARC FLASH PPE LABELING STRATEGY

Hamdy Faramawy Senior Application Specialist ABB Sweden

PRECAST FLOOR PRODUCTION SEMI - PRO - EDGE

Ritz Instrument Transformers GmbH. Welcome

MV network design & devices selection EXERCISE BOOK

SGMF(T) series. Onsite Mobile AC High Voltage Test System. Applications:

Shunt Reactors. Global Top Energy, Machinery & Plant Solution Provider

PRECAST WALL PRODUCTION SEMI - PRO - EDGE

Transformers TRANS FORM ERS

Sensor Technology. Applications for medium voltage

New Products Catalogue 2009 Safety Relays ESR5

Siemens AG Safe and Flexible Power Distribution in the Automotive Industry SIVACON. Answers for industry.

MV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer

I -limiter The world s fastest switching device

Busbar Trunking Assembly

FLOOR TYPE MILLING-BORING CENTRE

KEVCY 24 RE1; KEVCY 24 RF1 Indoor combined sensor; Indoor voltage sensor

Substation: From the Outside Looking In.

Electricity Meters Grid metering. Electricity Meter. Landis+Gyr E850 ZMQ200. Increased revenue through high accuracy and tailored grid functions

Medium Voltage Products. KECA 80 C85 Indoor current sensor

Safe and efficient power transmission in wind turbines

Company Directive STANDARD TECHNIQUE: SD7F/2. Determination of Short Circuit Duty for Switchgear on the WPD Distribution System

MEDIUM & HIGH VOLTAGE

Testing of 400 kv GIS

StarSine Power Quality Products

VACUUM INTERRUPTER APPLICATION NOTES Filename: VIAN X-Rays and Vacuum Interrupters Revision: 0 PAGE 1

IBAR (EMEA) LIMITED Castle Mills Aynam Road Kendal Cumbria LA9 7DE UK YEARS+ Established. t. +44 (0) e.

MicroControl: high quality products, premium service, satisfied customers

CAST RESIN DRY TRANSFORMER

50 YEARS+ A brand of the. IBAR (EMEA) LIMITED Castle Mills Aynam Road Kendal Cumbria LA9 7DE UK

Busbar Trunking Systems

Numbering System for Protective Devices, Control and Indication Devices for Power Systems

3-phase short-circuit current (Isc) at any point within a LV installation

Energizing a world that demands more

SPTS 1 - Ratings and General Requirements for Plant, Equipment and Apparatus for The ScottishPower System and Connection Points to it.

H V T E S T S O L U T I O N S PA RT N E RS F O R H V & E M C

ELEC Transmission i and

AM SGB Sdn Bhd. Company Profile. Transformer First Class

The power behind a Leader

CONVERSIONS FOR PROJECTILE WEAVING MACHINES

Convincing technology creates compact performance

FIXED TABLE TRAVELLING COLUMN MILLING CENTRE

Need for grounding Codes and Standards for grounding Wind Turbine Generator grounding design Foundation + Horizontal Electrode grounding design

IP68 RCP RESIN BUSBAR TRUNKING FOR POWER DISTRIBUTION POWERED BY SPECIALISTS

ELECTRICAL NETWORKS SPECIFICATION TECHNICAL SPECIFICATION FOR A 230V/110V AND 400V/110V TRANSFORMER

Resin Casting and Impregnating Technology from the Expert

Integration between the MV protection and control unit REF542 and the LV protection trip unit PR123: selectivity and earth fault 1SDC007402G0201

HARTING. Value Added Solutions

SYSTEMS AND COMPONENTS FOR TRANSFORMER TESTING

Totally Integrated Power SIVACON 8PS LDM busbar trunking system siemens.com/ldm-system

P2 H2 NAMEPLATE 6 HOLES M8-10 M SCREW S1 1S2 1S3 X1 X2 X3 PARALLEL HIGH RATIO

RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL

Liquid-Filled Transformers

Miniature substations: What they are really capable of delivering

Harmonic Solutions. Clean Power Drive Solution to Harmonic Distortion

LIGHT ARC DETECTOR Type LAD

High-Speed DC Circuit-Breaker for Fixed Installation Type UR26, UR36 & UR40

Siemens AG Allows easy and consistent configuration with one series of overload relays (for small to large loads)

D.C. Hydraulic Power Systems

PREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION!

Company Directive STANDARD TECHNIQUE: TP6F/1. Power Measurement Conventions

Transcription:

Low to medium voltage distribution M2L integrated power distribution system A compact, integrated solution for medium voltage connection, transformer and low voltage distribution

Turnkey solution medium to low voltage Eaton plays an important role in the electrical network between the power plant and consumers. Eaton's solutions from the Holec productseries guarantee a safe and continuous power supply within this entire process. Eaton has power distribution products from medium voltage down to low voltage level. The M2L electrical distribution system integrates these products into a complete factory build solution, which combines the medium voltage connection and the low voltage distribution, including transformer. A turnkey solution which offers significant benefits, in terms of investment and usage, for installers and end customers. Medium voltage cable MV Switch room Transformer room Low voltage cable Low voltage distribution board Medium voltage cable Load Conventional situation Low voltage cable Medium voltage cable replaces low voltage cable New situation with Load What is the Eaton M2L electrical distribution system? It is a combined electrical distribution system containing a medium voltage switchgear, a transformer and a low voltage distribution board in a single housing. Hence the name Medium voltage to Low voltage: M2L. The entire system is prefabricated under controlled conditions at Eaton s assembly facilities in Hengelo and can be installed and connected at the construction site in a very short space of time. An Eaton M2L substation consists of the following tailormade components: Medium voltage switchgear system (type Xiria or SVS). Transformer (cast resin insulated). Low voltage distribution installation (type Capitole 20, 40 or CX). 2 Low to medium voltage distribution M2L integrated power distribution system

with double transformer. What are the benefits of the M2L package substation? Minimise expensive low voltage cables Use of the M2L distribution system enables the transformer to be placed much closer to where the power is needed (the centre of gravity of load). This eliminates the need for long and relatively expensive low voltage cables or busbar systems. When using the, a proportionately longer medium voltage cable is sufficient. Limit power losses in the cables The power losses in the longer medium voltage cables are only a fraction of the losses in low voltage cables or busbar systems. Use of the M2L substation considerably lowers the operating losses of the electrical installation since the transport of large quantities of power at low voltage level is associated with significant losses. These losses are limited at medium voltage level. This results in cost savings each year on the energy bills of end customers. Limit assembly costs The integrated solution results in considerable savings on assembly costs and limits the numbers of terminations. Instead of assembling a heavy package of low voltage cables or busbar systems, the only requires a single medium voltage cable to be connected. The connection with the transformer has already been preterminated and tested. Save on building costs for the technical room The can be installed in a general MV switch room without problems. This eliminates the need for the construction of medium voltage and/or transformer rooms. The M2L electrical distribution system can easily be installed in a factory, basement or on a landing. This results in considerable savings on building costs. By using dry-type or cast resin transformers, M2L reduces the five hazards associated with traditional fluid-filled transformers. Very short assembly time M2L are pre-assembled and tested in an ISO 9001 certified production line. It only takes an average of two working days to set up and test the system on the site. Tested ex-factory The M2L distribution system is a proven concept; the construction of medium voltage connection, transformer and low voltage distribution is fully guaranteed and certified by Eaton when performed by Eaton s service organisation. Medium voltage switchgear Transformer Low voltage distribution board Low to medium voltage distribution M2L integrated power distribution system 3

Tailor-made solutions with reliable components Medium voltage systems Low voltage distribution systems s can be equipped with the following medium voltage systems: Xiria, ring main units 3.6-24 kv Xiria ring main units are extremely compact. Xiria units are supplied in two, three, four or five-panel versions. Both the primary part of the unit and the mechanisms are housed in a fully enclosed housing. The ring main unit can be fitted with: Capitole 20. Capitole 40. A vacuum load break switch for ring cable connections. A vacuum circuit breaker with integrated protection to protect mains transformers and cable connections. Fixed vacuum circuit breakers. Vacuum load break switches. Vacuum load break switch/fuse units. Metering panels. Transformers up to 6 MVA SVS, modular switching system 3.6-24 kv The SVS cast resin insulated switching system is a compact modular system developed for the medium voltage range up to 24 kv. SVS panels are available with: s use drytype transformers. As a result, no additional fire safety or insurance requirements apply. Eaton can supply s with transformers from top quality manufacturers, in capacities up to 6 MVA Capitole 20, 40 and CX, main distribution systems up to 6300 A For several years now, Eaton has been supplying Capitole systems as a solution for main distribution systems. Eaton's distribution package consists of the Capitole 20 and 40 and type CX systems. Capitole 40 and Type CX are also available as a Motor Control Centre (MCC). Rated Short-circuit Outgoing current value panels Capitole 20 up to 3200 A up to 65 ka Plug-in Capitole 40 up to 6300 A up to 100 ka Withdrawable/ Plug-in/Fixed Type CX up to 4000 A up to 100 ka Withdrawable/ Plug-in/Fixed Capitole distribution systems have proven to be safe and reliable. The systems are designed for safety of personnel and have an ergonomic innovative design. There is optimum internal separation between the feeder panels and outgoing panels: up to Form 4 in accordance with EN-IEC 61439-1. Outgoing panels are connected to the vertical distribution busbars using plug-in contacts. The Capitole 40 and Type CX offer the option of fixed or withdrawable outgoing panels. The Type CX is reliable in operation and has a reliable mechanical test position. The system has full internal separation of all functional units (Form 3b or 4b). Type CX. Eaton's medium voltage installations are SF 6 -free as they are based on environ mentally friendly vacuum switch gear technology and solid insulation, and optionally combined with air insulation. See http://www.greenswitching.com Optional: Intelligent metering Naturally, M2L electrical distribution systems can be equipped with an intelligent communication and energy management system. Low to medium voltage distribution M2L integrated power distribution system 4

Cost example An organisation is involved in a new-build project and requires a medium voltage connection, medium voltage transformer and low voltage distribution board. The total cable length between the installations is 100 metres. In the cost example below, we compare the differences in cost between a conventional solution and an M2L package substation. Both versions are based on a Capitole 40 low voltage distribution board and a Xiria medium voltage installation. Use of the M2L package substation results in a cost saving in this fictitious example of 20% compared to the conventional solution. The figures specified provide an indication of the possible cost savings that can be made by using the M2L package substation. The actual savings will naturally depend on the specific business situation. Conventional With M2L Costs solution package substation Differences Information Investment costs Low voltage installation 43,000 - Capitole 40 Medium voltage installation 9,000 - Xiria Transformer 25,000-1,600 kva - 109,000 Capitole 40 / Xiria / Transformer including installation and assembly on location Building costs Technical room 25,000 - Medium voltage cable 4,000 (50 metres) 8,000 (100 metres) 80 per metre Low voltage cable 16,500 (50 metres) - 330 per metre Installation & assembly costs Installation costs 4,200 - Already included in the price for the Assembly costs 10,000 - Already included in the price for the LV termination costs 800 - MV termination costs 1,300 1,300 Operating costs 9,000 - Difference in power loss based on 10 years in operation Total 147,800 118,300 29,500 Tailor-made advice for the The savings you can make by using the M2L package substation and the choice of combination best suited to you is something we will be happy to discuss with you in person. We can put together a suitable solution based on your wishes and requirements. Customisation and good communication regarding requirements usually result in significant cost savings on the entire project. We would be happy to perform a cost calculation with you for your specific situation based on your company profile and your specific cost factors (purchase prices, hourly rates etc). This will enable us to show you the cost advantages you can achieve by using the. Maintenance and management Eaton can take complete care of the required maintenance and management of the. In addition, Eaton offers the option of a network study for optimum finetuning of the component settings to the total network configuration. Reliable and proven technology Eaton has more than 20 years' experience of installing these systems. The M2L power distribution board is a proven concept. This combination of medium voltage, transformer and low voltage is fully guaranteed and certified by Eaton. Frequently Asked Questions Our website contains a list of frequently asked technical questions. Should an always be installed in a technical room? Does the building need to meet additional requirements if an is installed? Who is responsible for earthing the M2L package substation? Download the complete FAQ list at www.eaton.com/uk 5 Low to medium voltage distribution M2L integrated power distribution system

Eaton s Electrical Sector is a global leader in power distribution, power quality, control and automation, and monitoring products. When combined with Eaton s full-scale engineering services, these products provide customer - driven PowerChain solutions to serve the power system needs of the data center, industrial, institutional, public sector, utility, commercial, residential, IT, mission critical, alternative energy and OEM markets worldwide. PowerChain solutions help enterprises achieve sustainable and competitive advantages through proactive management of the power system as a strategic, integrated asset throughout its life cycle, resulting in enhanced safety, greater reliability and energy efficiency. For more information, visit www.eaton.com/electrical. Eaton Electric Limited Grimshaw Lane Middleton Manchester M24 1GQ United Kingdom Customer Support Centre Tel.: +44 (0)8700 545 333 Fax: +44 (0)8700 540 333 E-mail: ukcommorders@eaton.com 2011 Eaton Corporation All rights reserved. Printed in United Kingdom. Form. No. BR02200002U January 2011