Keysight Technologies Automated Receiver Sensitivity Measurements Using U8903B. Application Note

Similar documents
Keysight Technologies Differences in Application Between Power Dividers and Power Splitters. Application Note

Keysight Technologies Migrating Balanced Measurements from the

Keysight Technologies Accurate NBTI Characterization Using Timing-on-the-fly Sampling Mode. Application Note

Keysight Technologies

Keysight Technologies Improving the Test Efficiency of MEMS Capacitive Sensors Using the E4980A Precision LCR Meter.

Keysight Technologies 8490G Coaxial Attenuators. Technical Overview

Keysight Technologies Improving Test Efficiency of MEMS Electrostatic Actuators Using the E4980A Precision LCR Meter.

Keysight Technologies

Keysight Technologies N9310A RF Signal Generator

Introduction. Part 1. Introduction...2

Keysight Technologies Simultaneous Measurements with a Digital Multimeter

Keysight Technologies Making Field Effect Transistor Characterization Using SMU

Keysight Technologies Optimizing RF and Microwave Spectrum Analyzer Dynamic Range. Application Note

Keysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide

Keysight Technologies Understanding the Importance of Maximum Power Point Tracking Efficiency for Solar Inverters.

Keysight Technologies Network Analyzer Measurements: Filter and Amplifier Examples. Application Note

Keysight Technologies P9400A/C Solid State PIN Diode Transfer Switches

Keysight 8474B/C/E Planar-Doped Barrier Diode Detectors 0.01 to 50 GHz. Data Sheet

Keysight Technologies MEMS On-wafer Evaluation in Mass Production

Keysight E5063A ENA Vector Network Analyzer

Keysight DSOXT3FRA/DSOX4FRA/DSOX6FRA Frequency Response Analyzer (FRA) Option

Keysight Technologies N6850A Broadband Omnidirectional Antenna. Data Sheet

Keysight Technologies N4985A System Amplifiers

Keysight Technologies Measuring Group Delay of Frequency Converters with Embedded Local Oscillators. Application Note

Keysight Technologies How to Easily Create an Arbitrary Waveform Without Programming. Application Note

Keysight Technologies N4983A Multiplexer and Demultiplexer. Data Sheet

Keysight HMMC-1002 DC 50 GHz Variable Attenuator

Keysight Technologies Measuring Low Current Consumption with a Digital Multimeter

Keysight Technologies 423B, 8470B, 8472B, 8473B/C Low Barrier Schottky Diode Detectors

Keysight N9311X RF and Microwave Accessory Kit for Low-cost Handheld and Benchtop Solutions. Technical Overview

Keysight E5063A ENA Series Network Analyzer

Keysight M940xA PXIe Optical Extenders for Instrumentation. Data Sheet

Keysight Technologies Make Better AC RMS Measurements with Your Digital Multimeter. Application Note

Keysight Technologies USB Preamplifiers

Keysight Technologies Precise Low Resistance Measurements Using the B2961A and 34420A

Keysight Technologies Accurate Capacitance Characterization at the Wafer Level

Keysight Technologies MATLAB Data Analysis Software Packages

Keysight Redefines 50 GHz Portability. Get a $30k Credit When You Move Up to FieldFox

Keysight Technologies Making Simpler DC Power Measurements with a Digital Multimeter

Keysight Technologies HMMC GHz High-Gain Amplifier

Keysight N8836A PAM-4 Measurement Application For Infiniium S-Series, 90000A, V-Series, X-Series, Q-Series, and Z-Series Oscilloscopes

Keysight M9485A PXIe Multiport Vector Network Analyzer

Keysight Technologies Using a Network and Impedance Analyzer to Evaluate MHz RFID Tags and Readers/Writers

Keysight Technologies FFT and Pulsed RF Measurements with 3000T X-Series Oscilloscopes. Application Note

Keysight N9310A RF Signal Generator

Keysight Technologies Using a Scope s Segmented Memory to Capture Signals More Efficiently. Application Note

Keysight Technologies VSA Software for Simulation Environments BE/89601 BNE

Keysight Technologies Waveguide Power Sensors. Data Sheet

Keysight Technologies Direct Power MOSFET Capacitance Measurement at 3000 V

Keysight Technologies 89601B-SSA/89601BN-SSA Spectrum Analysis VSA Software

Keysight Technologies Precise Current Profile Measurements of Bluetooth Low Energy Devices using the CX3300. Application Brief

Keysight Technologies Migrating from the 4268A/4288A Capacitance Meter to the E4981A Capacitance Meter. Technical Overview

Keysight Technologies N2792A/N2818A 200 MHz and N2793A/N2819A 800 MHz Differential Probes. Data Sheet

Keysight Technologies Power of Impedance Analyzer

Keysight Quickly Generate Power Transients for Testing Automotive Electronics. Application Note

Keysight Technologies N9398C/F/G and N9399C/F DC Block. Technical Overview

Keysight Technologies Improve the Accuracy and Efficiency for Organic-Thin Film Transistor (Organic-TFT) Characterization

Keysight Technologies How to Read Your Power Supply s Data Sheet. Application Note

Keysight Technologies Overcoming LTE-A RF Test Challenges. Application Note

Keysight Measuring High Impedance Sources Using the U8903B Audio Analyzer. Application Note

Keysight Technologies Split Post Dielectric Resonators for Dielectric Measurements of Substrates. Application Note

Keysight Technologies Maximizing the Life Span of Your Relays

Keysight U1882B Measurement Application for Infiniium Oscilloscopes. Data Sheet

Keysight Technologies, Inc. UWB Antenna Measurements with the 20 GHz E5071C ENA Network Analyzer. Application Note

Keysight Technologies Accurate Evaluation of MEMS Piezoelectric Sensors and Actuators Using the E4990A Impedance Analyzer.

Keysight Technologies Electronic Calibration (ECal) Modules for Vector Network Analyzers

Keysight Technologies Automotive ECU Transient Testing Using Captured Power System Waveforms. Application Note

Keysight Technologies Using an External Trigger to Generate Pulses with the B2960A

Keysight Technologies VOR and ILS Radio Navigation Receiver Test Using Option 302 for Keysight Signal Sources. Application Note

Keysight Technologies NFA Noise Figure Analyzer. Configuration Guide

Keysight Technologies Wide Range DC Current Biased Inductance Measurement

Keysight Technologies Phase Noise X-Series Measurement Application

Keysight Technologies N9063A & W9063A Analog Demodulation

Keysight N9320B RF Spectrum Analyzer

Keysight Technologies RF & Microwave Attenuators. Performance you can count on

Keysight Technologies PXI Vector Network Analyzer Series. Drive down the size of test

Keysight Technologies Achieving Accurate RF and Microwave Power Measurements for Satellite Thermal Vacuum Test. Application Note

Keysight Technologies Resistance Measurements Using the B2900A Series of SMUs

Keysight Technologies Solid State Switches. Application Note

Keysight Technologies Isolating Problems and Optimizing Wireless Designs with Digital Demodulation and EVM

Keysight Technologies N6141A & W6141A EMI X-Series Measurement Application. Technical Overview

Keysight N2806A Calibration Pulse Generator The world s fastest differential pulse generator. Data Sheet

Keysight Technologies InfiniiScan Event Identification Software

Introduction. Part 1. Introduction...2

Keysight Technologies

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Keysight Technologies High Frequency Probing Solutions for Time and Frequency Domain Applications. Application Note

Keysight Technologies N9398C/F/G and N9399C/F DC Block. Technical Overview

Keysight Technologies Amplifier and CW Swept Intermodulation - Distortion Measurements using the PNA Microwave Network Analyzers.

Keysight Technologies Enhance EMC Testing with Digital IF. Application Note

Keysight Technologies Active Differential Probes U1818A 100 khz to 7 GHz U1818B 100 khz to 12 GHz. Technical Overview

Keysight Technologies Making Current-Voltage Measurement Using SMU

Keysight Technologies PNA Receiver Reduces Antenna/RCS Measurement Test Times

Keysight N8803C CAN, LIN, FlexRay, and CAN-FD Protocol Triggering and Decode Software. Data Sheet

Keysight Technologies N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes. Data Sheet

Keysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview

Keysight Technologies Achieving Accurate E-band Power Measurements with E8486A Waveguide Power Sensors. Application Note

Keysight Technologies UXG X-Series Agile Signal Generator, Modified Version N5191A

Keysight Technologies 1 mw 50 MHz Power Reference Measurement with the N432A Thermistor Power Meter. Application Note

Transcription:

Keysight Technologies Automated Receiver Sensitivity Measurements Using U8903B Application Note

Introduction Sensitivity is a key specification for any radio receiver and is characterized by the minimum RF input level required to give a particular SINAD on the audio output. Traditionally this test involves the user manually reducing the RF level in fine steps whilst monitoring SINAD on an audio analyzer. This is a tedious, risk prone task since SINAD is an inherently noisy measurement. The task can of course be automated by some sort of test system under computer control. This however requires detailed knowledge of the measurement, extra equipment, controller and dedicated software. This note shows how the test sequencer together with the GPIB master functionality in the U8903B can be used to easily make automated Receiver Sensitivity measurements that are reliable and repeatable.

03 Keysight Automated Receiver Sensitivity Measurements using U8903B Application Note SINAD SINAD is an acronym for SIgnal, Noise And Distortion. This is an audio quality value which is used to specify the RF sensitivity of radio receivers. The ratio is usually expressed in db and is calculated as per the equation: rms value of signal,noise and distortion SINAD = 20 Log ( rms value of noise and distortion ) There are other forms of this equation depending on the exact form the values take, for example if the values are powers then the equation would use 10Log, if the values are already in db then the two components are simply subtracted. A higher SINAD value indicates higher quality audio. Measuring SINAD The classic block diagram of a SINAD measurement is shown in Figure 1. An RF signal of appropriate frequency is applied to the receiver under test, this RF signal is generally modulated with a 1 khz tone. On the top path the audio signal from the receiver is passed straight through to the level measurement block which measures the combined level of the signal, noise and any distortion. Through the lower path the audio signal from the receiver is applied to a notch filter the purpose of which is to remove the signal but leave any noise or distortion components for measurement. The two measurements are then used in the equation above to compute SINAD. Modern instruments tend to make more use of digital techniques to eliminate the analog notch filter and offer higher resolution. The audio signal is sampled as early as possible and the computation is performed in DSP as per the block diagram of Figure 2. These modern techniques offer increased accuracy and repeatability in many respects which will be discussed further throughout this note. Signal generator Radio receiver Audio level meter (S+N+D) Analog notch filter Audio level meter (N+D) RF signal modulated with a tone Audio with noise and distortion Figure 1. Typical block diagram of a SINAD measurement Noise and distortion Signal generator Radio receiver ADC DSP RF signal modulated with a tone Audio with noise and distortion Figure 2. Block diagram showing the sampling of an audio signal and computation in DSP

04 Keysight Automated Receiver Sensitivity Measurements using U8903B Application Note Receiver Sensitivity This is the minimum RF level specification of a radio receiver. The task is to find the minimum RF level which results in a particular SINAD level. This level is generally 12 db for a communications receiver and 23 db (mono) or 26 db (stereo) for a broadcast receiver such as a car radio or HiFi tuner. At first it may seem a little strange that an audio quantity is used to quantify the RF performance of a radio receiver, this however is quite logical once the subject is explored. The basic receiver block diagram of Figure 3 will be used to describe how the two quantities are related. Let s start at the right hand side of the diagram where we have the audio detector. This block has the job of extracting the audio signal from the IF carrier. From a measurement point of view it converts an IF Signal/Noise Ratio into an Audio SINAD Ratio. The block will of course have imperfections of its own which will be ignored for the purposes of this example. When considering a 2 way communications radio the general minimum standard for SINAD is 12 db. This amounts to audio distortion of 25% which is the minimum deemed intelligible. The detector will require a particular IF S/N Ratio in order to provide this 12 db SINAD. The particular value of S/N required will depend very much on the detector employed. For this example we will assume we have an analogue detector or demodulator of some description and that it requires 10 db S/N to give 12 db SINAD. In order to calculate the expected receiver sensitivity we need to know 3 other parameters. 1. The bandwidth of the signal being applied to the detector as defined by the IF Filter. 15 khz is chosen here since this is a typical value in a communications receiver. 2. The Noise Figure of the receiver, this is the noise added by the receiver circuitry and is primarily defined by the input filtering and Low Noise Amplifier (LNA). 3. The theoretical noise floor at the input of the receiver, this is defined by the impedance and for a 50 Ω system this is well documented as 174 dbm/hz. Antenna RF filter Low noise amplifier Mixer IF filter Loudspeaker Theoretical RF noise floor 174 dbm/hz 15 khz IF S/N ratio Detector or demodulator AF SINAD Local oscillator Figure 3. Basic receiver block diagram

05 Keysight Automated Receiver Sensitivity Measurements using U8903B Application Note The receiver sensitivity is then calculated as: Noise Floor + Noise Figure + Bandwidth + S/N at Detector = 174 + 3 + 10Log(15 k)+10 = 119.24 dbm (0.24 uv, 50 Ω) So, for 12 db SINAD this receiver requires a minimum of 119 dbm RF signal at its antenna. From the above example it is clear that the only variable available as a design parameter is the Noise Figure of the receiver. To this end the input amplifier and filter are very critical areas of design in any receiver. We should also note that the sensitivity calculated here will only be realizable with a signal generator connected to the receiver. In the real world environment where an antenna is used, background noise will affect performance. Measuring SINAD Using U8903B The U8903B is the ideal modern instrument for making SINAD measurements. Figure 4 shows the general measurement setup, in this case the modulation signal originates from the U8903B. Another common arrangement is where the signal generator provides its own modulation if it has such a feature. This simplifies the measurement setup slightly. The Signal Generator is set to the desired RF frequency and level. The deviation (FM) or modulation depth (AM) of the modulating tone is set to an appropriate level. The audio output level of the receiver is then set as required and connected to the Audio Analyzer, this can be by direct connection or alternatively by an appropriate acoustic coupler. Signal generator RF out RF in (antenna) Audio out (speaker) Audio in (modulation) Two-way radio (under test) U8903B Audio Analyzer Audio out Audio in Figure 4. General SINAD measurement setup

06 Keysight Automated Receiver Sensitivity Measurements using U8903B Application Note Making the measurement is simply a case of selecting SINAD as one of the Analyzer measurement functions as per Figure 5. A SINAD level which deviates from what is expected indicates that something is wrong but gives no indication as to what the problem might be. Investigation of the RF path and audio sections of the receiver would then follow to diagnose the actual cause of failure. The U8903B offers several variables that the user can control within the SINAD measurement. Figure 5. The U8903B Analyzer menu Fundamental Frequency The fundamental frequency is generally detected automatically as part of the SINAD measurement. This can however be problematic when there are other high level tones in the spectrum such as might be the case when doing a blocking test. The fundamental frequency can be set to track the generator. It is also possible to force the analyzer to use a fixed frequency and this is generally the best option when measuring low levels of SINAD. Filtering SINAD measurements should be made within a specified audio bandwidth. The radio receiver itself may well define this bandwidth but the bandwidth settings of the measurement instrument should also be considered. U8903B has an array of built in filters as well as the ability to import custom filter files.

07 Keysight Automated Receiver Sensitivity Measurements using U8903B Application Note Averaging/Sample Size Measuring the SINAD limit on any receiver is an inherently noisy measurement. The limiting amplifiers in the receiver will no longer be limiting completely and so the high gain in the system will act on any small changes in level. Lower SINAD readings from a radio receiver (like 12 db) can therefore benefit from some averaging. The plot of Figure 6 shows the difference in the distribution for 1000 measurements with no averaging and with 5 averages. Note that the result with no averages is not a less accurate result; on the contrary it is more indicative of the variations in the noise levels. Increasing the sample size has a similar effect to averaging. It simply means that each measurement looks at the signal for a longer period. Increasing the sample size as opposed to having a high number of averages is a slightly faster measurement since it s not made up of multiple measurements. For the ultimate in stability a combination of averaging and increased sample size can of course be used. This does make the measurement inherently slow. This is very problematic when manual measurements are being used but not so concerning when using the automated test sequence to be described. As the SINAD value increases the requirement for averaging reduces since the measurement can focus on the signal with less influence from noise. 450 400 No averages 5 averages 350 300 Ocurrence 250 200 150 100 50 0 6 7 8 9 10 11 12 13 14 15 SINAD Figure 6. SINAD plot showing the difference in the distribution for 1000 measurements with no averaging and 5 averages

08 Keysight Automated Receiver Sensitivity Measurements using U8903B Application Note Notch Filter The U8903B employs a digital notch filter which essentially removes a very narrow area of spectrum around the fundamental signal. Older measurement instruments use an analog notch filter having a much more gentle transition into the notch, this means that more of the signal around the fundamental is removed and this can give an apparently better SINAD reading. U8903B has an analog notch emulator built in so that users can more accurately replicate their legacy measurements if this is desirable. U8903B Test Sequencer The U8903B test sequence function provides users with a flexible, easy-to-use interface (Figure 7) for creating quick and convenient automated test sequences. Most automated test programs can be created in just a few minutes without the need to know any programming language, development tools or measurement science. All this can be done using the U8903B s front panel. The test sequence function can: Implement an unlimited series of measurements in a predefined sequence. Customize the setting of each measurement to suit your application. Set the limit of each measurement result and make FAIL/PASS judgments automatically. Generate test reports automatically and export them as Microsoft Word (.docx) documents for file management and use in design verification test, hardware qualification, and production test. Figure 7. The U8903B Test Sequence Application

09 Keysight Automated Receiver Sensitivity Measurements using U8903B Application Note Receiver Sensitivity Application The Receiver Sensitivity Application within the U8903B takes away all the risk and time issues associated with manual Sensitivity measurements. The expense and extra complexity of a system controlled measurement as well as the need for detailed measurement knowledge is also eliminated by allowing the U8903B to directly control the signal generator. The block diagram is shown in Figure 8. This is the same as the basic block diagram of Figure 3 but with the addition of a 82357B USB/GPIB interface. This offers a simple low cost upgrade to any existing manual process. Signal generator RF out RF in (antenna) Audio out (speaker) Audio in (modulation) GPIB control 82357B USB/GPIB interface Two-way radio (under test) USB/GPIB master Audio in Audio out U8903B Audio Analyzer Figure 8. Automated Receiver Sensitivity Application setup

10 Keysight RF Testing of WLAN Products Application Note The user interface for the Receiver Sensitivity Application is shown in Figure 9. The range of powers over which the Signal Generator sweeps as well as the step size is entered by the user as is the target SINAD limit level. All the usual averaging, filtering options etc associated with SINAD are available within this interface. It s also possible to configure the general parameters of the signal generator such as RF frequency and deviation. The application has default settings for Keysight Technologies, Inc. Signal Generators but it is also possible to enter the SCPI strings for any signal generator that may be available. Once setup, the application can be executed in isolation or as part of a larger test sequence. Example results are shown in Figure 10. This plot shows a wide RF sweep from 80 dbm to 120 dbm and the corresponding SINAD from near 40 db to the noise floor. A production test would typically operate over a narrower sweep range to minimize test time. The application uses the results of the sweep to calculate the Sensitivity at the exact target SINAD value. The result is then reported as an RF power in dbm as well as a voltage in a 50 Ω environment. The receiver used for this particular measurement was a radio microphone receiver. This has much wider bandwidth than a typical 2 way radio making it less sensitive as indicated by the reading of -108.5 dbm (0.84 uv, 50 Ω). Limit lines or discrete values set the pass/fail criteria for the application. The dotted red line in the graph shows the limits in this particular example. Figure 9. Automated Receiver Sensitivity Application User Interface Figure 10. Automated Receiver Sensitivity Application measurement results

11 Keysight Automated Receiver Sensitivity Measurements using U8903B Application Note Conclusions This note discusses SINAD measurements and how they relate to Receiver Sensitivity. It shows the ease with which SINAD measurements can be made on the U8903B and gives an introduction to the built in test sequencer. The Receiver Sensitivity Application is also discussed. This shows how automated repeatable and reliable receiver sensitivity measurements can be made without a system controller, software or any specific measurement knowledge. With the addition of an inexpensive USB/GPIB controller any existing manual measurement process can be updated and automated reducing test time and freeing up resource. U8903B is shown to be uniquely positioned as the ideal instrument for making SINAD and automated Receiver Sensitivity measurements.

12 Keysight Automated Receiver Sensitivity Measurements using U8903B Application Note Evolving Since 1939 Our unique combination of hardware, software, services, and people can help you reach your next breakthrough. We are unlocking the future of technology. From Hewlett-Packard to Agilent to Keysight. For more information on Keysight Technologies products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada (877) 894 4414 Brazil 55 11 3351 7010 Mexico 001 800 254 2440 United States (800) 829 4444 mykeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. http://www.keysight.com/find/emt_product_registration Register your products to get up-to-date product information and find warranty information. Keysight Services www.keysight.com/find/service Keysight Services can help from acquisition to renewal across your instrument s lifecycle. Our comprehensive service offerings onestop calibration, repair, asset management, technology refresh, consulting, training and more helps you improve product quality and lower costs. Keysight Assurance Plans www.keysight.com/find/assuranceplans Up to ten years of protection and no budgetary surprises to ensure your instruments are operating to specification, so you can rely on accurate measurements. Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight s measurement expertise and product breadth, combined with channel partner convenience. Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 11 2626 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 6375 8100 Europe & Middle East Austria 0800 001122 Belgium 0800 58580 Finland 0800 523252 France 0805 980333 Germany 0800 6270999 Ireland 1800 832700 Israel 1 809 343051 Italy 800 599100 Luxembourg +32 800 58580 Netherlands 0800 0233200 Russia 8800 5009286 Spain 800 000154 Sweden 0200 882255 Switzerland 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) United Kingdom 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-9-7-17) DEKRA Certified ISO9001 Quality Management System www.keysight.com/go/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2015 Quality Management System This information is subject to change without notice. Keysight Technologies, 2017 Published in the USA December 2, 2017 5992-0369EN www.keysight.com