Wind Direction Transmitter - compact - with Poti Output xx.712

Similar documents
Wind Transmitter compact xx

Wind Direction Transmitter - compact - with Poti Output xx.712

Wind Direction Transmitter - compact - GMR, analogue output xxx xxx

Wind Direction Transmitter - compact - TMR, analogue output x.xxx xxx

Wind Transmitter - compact

Wind Transmitter - with frequency output xx.xxx

Wind Transmitter - with analogue output xxx

Precipition Sensor with analogue Intensity Output ,

Precipitation Monitor ,

Wind Direction Transmitter - compact - GMR, analogue output xxx

Wind Direction Transmitter - compact

Wind Direction Transmitter - compact - with serial output x0.x00

Instruction for Use /05/09. Wind Transmitter - compact x0.xxx x0.xx x0.xx0

Wind Direction Transmitter First Class analogue output x0.1xx

Wind Transmitter compact xx

Wind Transmitter First Class Advanced Classified according to IEC ( )

Wind Direction Transmitter First Class analogue output x0.1xx

Combined Wind Transmitter - with analogue output xxx

Wind Transmitter First Class

Wind Transmitter First Class / 141 / / 141 / 161

Wind Direction Transmitter First Class Low Power Device with digital output, 8 Bit serial-synchronous x0.000

FINAL. Hygro-ThermoTransmitter-compact xxx xxx MEETINSTRUMENTATIE. Instruction for use /06/ x4.0xx/1xx/4xx/8xx...

Brightness Transmitter

WIND VANE THIES COMPACT

Baro Transmitter PTB x1.073

Hygro-ThermoTransmitter-compact xxx

WIND VANE THIES COMPACT TMR

Brightness Transmitter - direction-independent xxx

Precipitation Transmitter / 008 / 009 / 010 / 011 / 107 / / 009

Wind Direction Transmitter First Class - Device with digital output, RS Wind velocity signal acquisition x0.400

Digital Anemometer

Precipitation transmitter

WIND VANE THIES FIRST CLASS 2014 TMR

Sensor PAR xxx

Baro Transmitter xxx

Precipitation Transmitter xxx / xxx

n Measurable displacements between n Linearity: max. ± 0.05 % n Housing diameter 12.9 mm n Service life: 10 8 movements

THE WORLD OF WEATHER DATA Measurement and Documentation: Thies range of service for meteorology, environmental protection and industry

OPERATING INSTRUCTIONS

XXXX e. X d.. X X X a

XXXX e. X d.. X X X a

4-Port Antenna ircu / /65 16/18.5dBi 0 10 /0 10 T V01

Top spin Nr /

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Miniature resistance thermometer Model TR33, thread-mounted

2-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT Enhanced Sidelobe Suppression

6-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT set by hand or by optional RCU (Remote Control Unit)

LENORD. +BAUER... automates motion. GEL 295x Customer-specific precision encoder. Technical Information Version General information.

Accessories Solar Datatechnology Wireless-Set485-01/-Set485-02

Operating Instructions for Pressure Sensor with Ceramic Sensor Element. Model: SEN-9601

Assembly instructions Pantograph shutters

ADDUCO Hydraulic Clamping Nut

Signature Choral Riser Side Rail

ABSOLUTE ROTARY ENCODER MULTI-TURN BIT PARALLEL

USER'S GUIDE. Vaisala HUMICAP Humidity and Temperature Transmitters HMD70U/Y U303EN11

6-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT set by

NOVOHALL Rotary Sensor non-contacting. Series RSX-7900

4-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT

Magnetic Inductive Flow Sensor induq

4-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT

INLINE flowmeter for continuous flow measurement

SRS SEALED ROTARY SENSORS

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Assembly Instructions and Owner s Manual Flex TechBridge

CHAINSAW SHARPENER MODEL: ECSS-1

Please read and understand the OnBoard Timpani Cart Owner s Manual before using the Timpani Cart.

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Torque Sensor Series 3000 and Series 4000

OnBoard Bass Drum/Gong Cart

Operating manual GTL 241 GTL 251. Temperature probe. Please keep the manual for future use.

JUMO Dtrans T100 Screw-in RTD Temperature Probe with/without Transmitter

Ambient Weather EZ Stable Mounting Kit with Mast for AcuRite Weather Stations User Manual

MANUAL HYDROBAR. Manufactured by: Fax: H/US/Hydrobar/ /00 Klay Instruments Page 1

Snow Scale SSG. Snow measurement system. Assembly instructions Sommer GmbH. All rights reserved.

Operating Instructions. Combination sensor

WIND T H E W O R L D O F W E A T H E R D A T A

Flow sensor HVAC 100 (548000) Instruction for use. Imprint: Copyright all rights reserved Version Subject to modifications

T22. Torque transducer. Special features. Data sheet

MTS-SP100. RENOGY Pole Mount System E Philadelphia St, Ontario, CA Version: 1.2

Analogue temperature transmitter Model T91.10, head mounting version DIN form B Model T91.20, head mounting version form J

Phone: Fax: Web: -

Instruction for Use /10/17

Analog amplifier RA. RE Edition: Replaces:

...thoroughly tried and tested!

Technical manual. Microstep driver SMC11. NANOTEC ELECTRONIC GmbH & Co. KG Gewerbestraße 11 D Landsham near Munich, Germany

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

SensyTemp TSBA (BA R) Resistance thermometer for building automation, machine construction and environmental engineering

7. Operating instructions: EFL 300

T40FM. Data Sheet. Torque flange. Special features. Overall concept. B en

- 4 - Fig. 3b. Fig. 1b. Fig. 2. Fig. 2b MT 300

SEPARATOR P20G TYPE USER S MANUAL

Standard Sendix 5000 / 5020 (shaft / hollow shaft) Push-Pull / RS422 / Open collector. Robust performance. Many variants

Operating Instructions K-POWERgrip EWL Always on the safe site.

6-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT

ABSOLUTE ROTARY ENCODER SSI

DT1100 E xx xx (PS) Galvanic Isolators. Operating Instructions

4-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT set by

WIND MONITOR ANEMO / WIND VANE YOUNG ALPINE

ORIGINAL INSTRUCTIONS

Transcription:

THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021434/05/09 Wind Direction Transmitter - compact - with Poti Output - 4.3129.xx.712 ADOLF THIES GmbH & Co. KG Hauptstraße 76 37083 Göttingen Germany Box 3536 + 3541 37025 Göttingen Phone +49 551 79001-0 Fax +49 551 79001-65 www.thiesclima.com info@thiesclima.com

Contents 1 Models available... 4 2 Application... 4 3 Construction and Mode of Operation... 4 4 Recommendation Side Selection / Standard Installation... 4 5 Installation... 5 5.1 Mechanical Mounting... 5 5.2 Electrical Mounting... 6 5.3 Plug Mounting... 7 6 Maintenance... 7 7 Connecting Diagrams... 8 8 Technical Data... 9 9 Dimensional Drawing... 10 10 Accessories... 11 11 EC-Declaration of Conformity... 12 2-14 021434/05/09

Safety Instructions Before operating with or at the device/product, read through the operating instructions. This manual contains instructions which should be followed on mounting, start-up, and operation. A non-observance might cause: - failure of important functions - Endangering of persons by electrical or mechanical effect - Damage to objects Mounting, electrical connection and wiring of the device/product must be carried out only by a qualified technician who is familiar with and observes the engineering regulations, provisions and standards applicable in each case. Repairs and maintenance may only be carried out by trained staff or Adolf Thies GmbH & Co. KG. Only components and spare parts supplied and/or recommended by Adolf Thies GmbH & Co. KG should be used for repairs. Electrical devices/products must be mounted and wired only in voltage-free state. Adolf Thies GmbH & Co KG guarantees proper functioning of the device/products provided that no modifications have been made to the mechanics, electronics or software, and that the following points are observed: All information, warnings and instructions for use included in these operating instructions must be taken into account and observed as this is essential to ensure trouble-free operation and a safe condition of the measuring system / device / product. The device / product is designed for a specific application as described in these operating instructions. The device / product should be operated with the accessories and consumables supplied and/or recommended by Adolf Thies GmbH & Co KG. Recommendation: As it is possible that each measuring system / device / product under certain conditions, and in rare cases, may also output erroneous measuring values, it is recommended using redundant systems with plausibility checks with security-relevant applications. Environment As a longstanding manufacturer of sensors Adolf Thies GmbH & Co KG is committed to the objectives of environmental protection and is therefore willing to take back all supplied products governed by the provisions of "ElektroG" (German Electrical and Electronic Equipment Act) and to perform environmentally compatible disposal and recycling. We are prepared to take back all Thies products concerned free of charge if returned to Thies by our customers carriage-paid. Make sure you retain packaging for storage or transport of products. Should packaging however no longer be required, arrange for recycling as the packaging materials are designed to be recycled. Documentation Copyright Adolf Thies GmbH & Co KG, Göttingen / Germany Although this operating instruction has been drawn up with due care, Adolf Thies GmbH & Co KG can accept no liability whatsoever for any technical and typographical errors or omissions in this document that might remain. We can accept no liability whatsoever for any losses arising from the information contained in this document. Subject to modification in terms of content. The device / product should not be passed on without the/these operating instructions. 3-14 021434/05/09

1 Models available Order-No. Meas. range Electr. Output Operating Voltage Potentiometer Heating Connection 4.3129.00.712 0...360 Potentiometer: 2 kω 0 24 V DC 24V, 20W 7 pol. plug 4.3129.04.712 0...360 Potentiometer: 2 kω 0 24 V DC 24V, 20W 7 pol. plug 4.3129.10.712 0...360 Potentiometer: 2 kω 0 24 V DC w/o heating 7 pol. plug 2 Application The wind direction transmitter is designed for the acquisition of the horizontal wind direction. The measuring value is output proportionally to wind direction as analogue voltage in case the potentiometer is supplied by a constant voltage. The measuring data available are ideally adapted to the supply in display instruments, recording instruments, datalogger, as well as process control systems. For winter time use the instrument is optionally equipped with an electronically regulated heating, in order to guarantee a smooth-running of the ball bearing, and to prevent a blocking of the gap between the external rotation parts by ice aggregation. Power for the heating system could be provided for instance by our Power Supply Unit, Order No. 9.3388.00.000 3 Construction and Mode of Operation The outer parts of the instrument are made of corrosion-resistant material ( aluminum, stainless steel, plastic ). The aluminum parts are additionally protected by means of an anodic coat. Labyrinth sealing protects sensitive parts inside the instrument against humidity. The wind direction is acquired by an inertia-free wind vane. The axis of the wind vane is held in ball bearings. A magnetic coupling connects the axis with the potentiometer in contact-free mode, thus providing for a smooth starting of the instrument. 4 Recommendation Side Selection / Standard Installation In general wind measurement instruments should be able to detect the wind conditions of a large area. In order to obtain comparable values when determining the surface wind, measurements should be taken at a height of 10 meters over an even unobstructed area. An unobstructed area means that the distance between the wind transmitter and an obstacle should be at least 10 times the height of the obstacle ( s. VDI 3786 ). If it is not possible to fulfil this condition, then the wind transmitter should be set up a height where local obstacles do not influence the measured values to any significant extent (approx. 6-10 m above the obstacle). 4-14 021434/05/09

The wind transmitter should be set up in the centre of flat roofs and not on the roof side in order to avoid bias in the direction (privileged directions). 5 Installation Attention: Storing, mounting and operation under weather conditions is permissible only in vertical position, as otherwise water can get into the instrument. Remark: When using fastening adapters (angle, traverses, hangers etc.) please take a possible effect by turbulences in their slipstream into consideration. 5.1 Mechanical Mounting The mounting of the transmitter could be done for example at a support with a boring of PG 21 or on hangers with a boring of 29 mm. Tools: Hexagonal wrench SW36 Procedure: 1. Push cable/ plug connector of the wind direction transmitter through the bore hole of the mast, tube, arm etc. 2. Put wind direction transmitter on mast, tube, arm etc. 3. Align the wind direction transmitter northwards (procedure see chapter 5.1.1). 4. Safeguard the wind direction transmitter by two hexagonal nuts (PG21, SW 36). Caution: The Hexagon nuts must be tightened to 6 Nm. Remark: The support is not included in delivery. 5-14 021434/05/09

5.1.1 North Alignment For the precise determination of the wind direction the wind direction transmitter must be aligned northwards (geographical north). Tools: Hexagonal wrench SW36 Procedure: 1. Rotate north marking (N) at the housing and wind vane axially one above the other, acc. to figure. 2. Determine a prominent spot in the surrounding area (tree, building etc.) in northward direction, by means of a compass. 3. Locate the prominent spot over wind vane and balance weight of the wind direction transmitter. 4. Align wind direction transmitter. The north marking must indicate the geographical north. 5. In case of conformity, safeguard the wind direction transmitter by two hexagonal nuts (PG21, SW 36). Caution: The Hexagon nuts must be tightened to 6 Nm. Remark: If the north alignment is carried out by compass, please consider the local declination (= deviation of direction of the magnetic needle from the true north), and local magnetic interferences (e.g. hardware, electric cable). When aligning the wind direction transmitter on a moving object (e.g. vehicle, wind wheel, ship etc.) please consider that the north point to be determined, might possibly be located on the object. 5.2 Electrical Mounting For electrical connection please refer to the connecting diagram. 6-14 021434/05/09

5.3 Plug Mounting Coupling socket, Typ:Binder, Serial 423, EMC with cable clamp Cable connection: without cable shield 1. Stringing parts on cable acc. to plan given above. 2. Stripping cable sheath 20 mm 3. Cutting uncovered shield 20 mm 4. Stripping wire 5mm. 5. Soldering wire to the insert 6. Positioning shield in cable clamp. 7. Screwing-on cable clamp. 8. Assembling remaining parts acc. to upper plan. 9. Tightening pull-relief of cable by screw-wrench (SW16 und 17). Cable clamp Wire Cable sheath 6 Maintenance After proper mounting the instrument works maintenance free. Heavy pollution can clog up the slit between the rotating and the stationary parts of the wind transmitter. This slit must be kept clean. 7-14 021434/05/09

7 Connecting Diagrams Attention: When the wind vane rotates over the north point (0 / 360 ) the potentiometer slider connects beginning and end of the potentiometer. Therefore, the supply voltage of the potentiometer must show a current limitation of max. 1 ma. When using power supply units temporary current peaks with the power control might lead to damages. Therefore, an additional protective resistance Is strongly recommended. Order No. Poti 4.3129.00.712 4.3129.04.712 4.3129.10.712* red yellow blue Heating 20 W green green View on the soldered joint of the counter plug A a R e E Hz Hz 7 pol. plug 1 2 3 4 5 6 7 3 4 2 7 1 6 5 Wind Direction Heating 24 V AC / DC 20 W *Order-no. 4.3129.10.xxx (w/o heating) PIN 6 and 7 are not connected Order No, Contact Name Function 1 A (AGND) Sense (-) 2 a (GND) Supply voltage (-) 3 R (SIG) Meas. signal (potent. slider) 4.3129.00.712 4 e (+Us) Supply voltage (+) 0...24 V DC 4.3129.04.712 5 E (Sense) Sense (+) 4.3129.10.712* 6 Heating supply: HZG Voltage: 24 V AC/DC 7 Power: 20 W ** Order-no. 4.3129.10.xxx (w/o heating) PIN 6 and 7 are not connected 8-14 021434/05/09

8 Technical Data Meas. range 0... 360 (0 Ohm in the North point) Resolution 0,5 Starting Threshold 1 m/s acc. to ASTM Standards D 5366-96 0.4m/s acc. to VDI Directive 3786 Part 2 Delay Distance < 2.5 m acc. to ASTM Standards D 5366-96 Accuracy ± 2 Measuring principle Potentiometer Potentiometer output 2 KOhm Electrical supply for potentiometer Operating voltage heating Voltage U s : 0V DC... 24 V DC, The supply must guarantee a current limiting to max. 1 ma short cut at the North point! 24 V DC/AC, max. 20 W Ambient temperature * -40 C... 70 C Survival speed Connection Dimensions Montage Protection IP 55 Weight Material Housing Vane Bottom maximally 80 m/s, 30 minutes 7 pol. Stecker see dimensional drawing For ex. onto a mast tube with receptacle thread PG 21 or boring 29 mm ca. 1,10 kg Aluminium (AlMgSi1) Synthetic with fibre glass (PC-GF10) Synthetic (POM H2320) * The ambient temperature, stated for wind direction transmitters without heating, is possible only in ice-free condition. 9-14 021434/05/09

9 Dimensional Drawing 10-14 021434/05/09

10 Accessories The following accessories are available for the wind direction transmitter: Traverse For mounting the wind speed transmitter and wind direction transmitter compact jointly onto a mast. 4.3171.30.000 4.3171.31.000 Clamping range: Ø 48... 102 mm Clamping range: Ø 116... 200 mm Sensor distance: 0,8 m Material: Aluminum Traverse, short For mounting the wind direction transmitter compact onto a mast. 4.3171.40.000 4.3171.41.000 Clamping range: Ø 48... 102 mm Clamping range: Ø 116... 200 mm Length: 0,4 m Material: Aluminum Lightning rod For mounting the a.m. traverses 506351 Length: 0,56 m Material: stainless steel Please contact us for other accessories such as cables, power supply units, masts, as well as for additional mast- or system-constructions. 11-14 021434/05/09

11 EC-Declaration of Conformity Document-No.: 001225 Month: 06 Year: 09 Manufacturer: A D O L F T H I E S G m b H & C o. K G Hauptstr. 76 D-37083 Göttingen Tel.: (0551) 79001-0 Fax: (0551) 79001-65 email: Info@ThiesClima.com Description of Product: Wind Direction Transmitter compact Article No. 4.3129.00.012A 4.3129.00.712 4.3129.04.712 4.3129.10.009 4.3129.10.012A 4.3129.10.712 specified technical data in the document: 021070/05/09; 021126/06/09; 021213/05/09 The indicated products correspond to the essential requirement of the following European Directives and Regulations: 2004/108/EC 2006/95/EC DIRECTIVE 2004/108/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 15 December 2004 on the approximation of the laws of the Member States relating to electromagnetic compatibility and repealing Directive 89/336/EEC DIRECTIVE 2006/95/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 12 December 2006 on the harmonisation of the laws of Member States relating to electrical equipment designed for use within certain voltage limits 552/2004/EC Regulation (EC) No 552/2004 of the European Parliament and the Council of 10 March 2004 on the interoperability of the European Air Traffic Management network (the interoperability Regulation) The indicated products comply with the regulations of the directives. This is proved by the compliance with the following standards: Reference number IEC 61000-6-2: 2005 IEC 61000-6-3: 2006 IEC 61010-1: 2001 Specification Electromagnetic compatibility Immunity for industrial environment Electromagnetic compatibility Emission standard for residential, commercial and light industrial environments Safety requirements for electrical equipment for measurement, control and laboratory use. Part 1: General requirements Place: Göttingen Date: 02.06.2009 This declaration certificates the compliance with the mentioned directives, however does not include any warranty of characteristics. Please pay attention to the security advises of the provided instructions for use. 12-14 021434/05/09

13-14 021434/05/09

ADOLF THIES GmbH & Co. KG Hauptstraße 76 37083 Göttingen Germany P.O. Box 3536 + 3541 37025 Göttingen Phone +49 551 79001-0 Fax +49 551 79001-65 www.thiesclima.com info@thiesclima.com - Alterations reserved- 14-14 021434/05/09