MSA500 - Hall effect transducer

Similar documents
MSA Hall effect transducer

MSV200 - Hall effect transducer

UB 001 relay - 1 level load shedding

UBC 200 relay - Voltage monitoring

UTC relay - Voltage monitoring & off delay

UB 200 relay - Voltage monitoring

TELAU 400 relay - Delay-on pull-in or

407 relay - Latching, safety critical, 40 contacts Datasheet

V88 socket - Spring clamp terminal,

Mors Smitt Industrial Technology. Industrial current & voltage sensors. Hall effect current & voltage sensors

KCS-U200 relay - Latching, 2 pole

BM 400 relay - Mixed load, 4 contacts

RC-19A relay - Current monitoring

TTBCR 200 relay - Delay-on drop-out,

AG 400 relay - Gold plated, 4 contacts

TBSBAO 400 relay - Delay-on pull-in,

D4-U200 relay module - 4-pole

C relay - Safety critical, 9 contacts

BD relay - Industrial latching power

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

CK relay - safety critical, 9 contacts

Mors Smitt Industrial Technology. High performance plug-in relays

Manual Signal calibration box (SCB)

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

CM relay - 7 contacts + 2 gold contacts

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

MTDV4-U200 relay - Voltage monitoring,

High Performance Current Transducer ITL 900-T = A

TDB4-U200 relay - Timer, delay-on, 4 pole

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and secondary circuit.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

DS2000UBLA-10V. Features. Applications: 20 ppm linearity. MPS for particles accelerators. 15 ppm offset. Gradient amplifiers for MRI devices

I P. /dt. di p V S Applications. Standards 1) IEC : 2007; IEC : ) IEC : 2016; IEC : 2017

DS400ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1.5 ppm. MPS for particles accelerators

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit.

MTDV4 relay - Voltage monitoring,

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

DS200ID-CD100. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 2 ppm. MPS for particles accelerators

DM1200ID. Specification highlights Symbol Unit Min Typ Max. Applications: Features. Power measurement and power analysis

DS2000ICLA. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

AUTOMOTIVE CURRENT SENSOR HC6H500-S. Datasheet

DQ600ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1 ppm. MPS for particles accelerators

DL2000ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.

I P. /dt. di p V S+ Applications. Standards. 1) IEC ed1.0: 2007; IEC : ed1.0: 2012

Voltage transducer DVL 50

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit.

Current Transducer CTSR 1-P = 1A

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit.

HC2F100-SN CLIPS AUTOMOTIVE CURRENT TRANSDUCER HC2F100-SN CLIPS. Datasheet

Mors Smitt Industrial Technology

I PM. Current Transducer ITZ 5000-SB FLEX ULTRASTAB = 5000 A

AUTOMOTIVE CURRENT SENSOR HC6H300-S

AUTOMOTIVE CURRENT TRANSDUCER HC6F600-S

AUTOMOTIVE CURRENT TRANSDUCER HC2F100-SN CLIPS

Technical catalog. Current sensors Voltage sensors. Contact John G Peck Ltd - jgpl.com

Technical catalogue. Current sensors Voltage sensors

SPECIFICATION Item no.: T60404-N4646-X400

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

AUTOMOTIVE CURRENT TRANSDUCER HC6H1000-S

Technical Catalogue. Current Sensors Voltage Sensors

Ref: HO 50-S/SP33, HO 100-S/SP33, HO 150-S/SP33, HO 200-S/SP33, HO 250-S/SP33

AUTOMOTIVE CURRENT TRANSDUCER HC6F700-S

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit.

Mors Smitt Industrial Technology

Mors Smitt Group - Serving Safety

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1DRW 300-S

Ref: HLSR 10-SM, HLSR 16-SM, HLSR 20-SM, HLSR 32-SM, HLSR 40-SM, HLSR 50-SM

I PN. Ref: HO 50-S, HO 100-S, HO 150-S, HO 200-S, HO 240-S, HO 250-S

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit.

Ref: HLSR 10-SM/SP33, HLSR 20-SM/SP33, HLSR 32-SM/SP33, HLSR 40-P/SP33, HLSR 50-SM/SP33

Ref: HLSR 10-P/SP3, HLSR 20-P/SP3, HLSR 40-P/SP3, HLSR 50-P/SP3

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

HO 50-S/SP30, HO 100-S/SP30, HO 150-S/SP30, HO 200-S/SP30, HO 250-S/SP30 and HO 200-S/SP31

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1DR 200-S

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH3DR 800-S03/SP2

DS10000ULFS-10V/10kA

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Closed Loop Current Sensors

= 1000 V. Voltage transducer DVC 1000-P V P N

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY DHAB S/157

V P N. Voltage transducer DVM 2000-B = 2000 V

V P N. Voltage transducer DVM 4200 = 4200 V

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Transcription:

- Hall effect transducer Datasheet Features Specially designed for railway applications losed loop (compensated) High dielectric strength Precise linearity Precise accuracy High dynamic response No foucault losses in the magnetic circuit EM shielding (optional) Wide temperature range, -50º..+85º Benefits Description The transducers are based on compensating the magnetic field by a closed loop system. The MSA500 is used for the measurement of A and D currents with high galvanic isolation between the current carrying conductor and output of the sensor. The current transducer can handle pulsed currents. The MSA500 transducers are especially designed for secure measuring of a permanent current up to 500 A. The current measuring range covers a bandwidth from -1000 A to 1000 A. Application The Mors Smitt transducers are used to measure high currents in rolling stock and track side applications. High currents are converted linear to low power signals. Proven reliable Long term availability Low life cycle cost No maintenance Railway compliancy EN 50155 - Railway application electronic equipment used in rolling stock IE 61373 - Rolling stock equipment - Shock and vibration test NF F16-101/102 - Fire behaviour - Railway rolling stock IE 60068-2-11 - Environmental testing: Salt mist - Test ka - 96 hours 1

onnection diagram MSA500 + M _ I SN R M +VD 0 V -VD -VD / 0 V (EM shield is an option, EM shield to be connected to -VD or 0 V) 2

Electrical characteristics Primary nominal r.m.s. current I PN 500 A Primary current measuring range I P + 1000 A Secondary nominal r.m.s. current I SN 100 ma @ K N = 1:5000 / 125 ma @ K N = 1:4000* onversion ratio K N 1:4000 / 1:5000 * Secondary coil resistance @ 70 º R S 35 W @ K N = 1:4000 / 43 Ω @ K N = 1:5000 * Auxiliary supply voltage V N + 15 VD... 24 VD urrent consumption I 30 ma + I S @ 24 VD Dielectric strength V D 6 kv / 10 kv (50 Hz - 1 min) * Output measuring resistance R M R M = ((V N dv) / I SN ) R S (see explanation below) * See ordering scheme Legend: Example: dv = Fixed value dv = 1.6 V V N = Nominal auxiliary supply V N = + 15 V V N = Lower value of the auxiliary supply (V N 5% typical) V N = + 14.25 V I PN = 500 A R S = Secondary coil resistance at 70 K N = 5000 turns I SN = Secondary current R S = 43 W I SN = I PN / K N I SN = 500 / 5000 = 0.1 A R M = ((14.25 1.6) / 0.1) 43) = 83.5 Ω Accuracy / dynamic performance Overall accuracy @ I PN - T A =25 º X G + 0.5% / + 1% * Linearity ε L < 0.1% Offset current @ I P =0 - T A =25 º I 0 + 0.2 ma max. Resp. time @ 90% of I PN and di/dt 100 A/ μs T R < 1 μs Di / dt accuracy followed di/dt > 50 A / μs Frequency bandwidth (-3 db) f D to 150 KHz * See ordering scheme General characteristics Operating temperature T A -40 o...+85 o or -50 o...+85 o * Storing temperature T S -40 o...+85 o or -50 o...+85 o * Storing temperature will follow operating temperature Weight m 200 g + 10 % (without busbar) 395 g + 10 % (with primary busbar 155 x 25 x 6 mm) onnection M4 with Faston 6.35 mm terminals - Faston 6.35 mm - Flying leads - M5 with Faston 6.35 mm terminals - Trim trio SMS 6 PDH1 - M5 terminals * * See ordering scheme 3

Dimensions (mm) M4 terminals EM shield terminal (optional) Notes: 1. onnection: 3 x M4 terminals, maximum torque value 2.2 Nm A 4th M4 terminal is placed when the EM shield option is selected (maximum torque value 2.2 Nm) 2. Fastening: 4 slots black marked Ø 5.5 mm for horizontal mounting and 4 slots black marked Ø 4.3 mm for vertical mounting 3. To obtain a positive output on the terminal marked M, primary current must flow in the direction of the arrow (conventional flow) 4. Temperature of the primary conductor should not exceed 100 o 5. General tolerances are + 0.5 mm, with exception of the input/output positions + 1 mm, length + 1 mm and on positions where the value is mentioned in the drawing 6. Drawing is according the European projection method 4

Dimensions (mm) Faston 6.35 mm terminals EM shield terminal (optional) Notes: 1. onnection: 3 x Faston 6.35 mm terminals, a 4th Faston 6.35 mm terminal is placed when the EM shield option is selected 2. Fastening: 4 slots black marked Ø 4.3 mm for horizontal mounting and 4 slots black marked Ø 4.3 mm for vertical mounting 3. To obtain a positive output on the terminal marked M, primary current must flow in the direction of the arrow (conventional flow) 4. Temperature of the primary conductor should not exceed 100 o 5. General tolerances are + 0.5 mm, with exception of the input/output positions + 1 mm, length + 1 mm and on positions where the value is mentioned in the drawing 6. Drawing is according the European projection method 5

Dimensions (mm) Flying lead terminals EM shield terminal (optional) EM shield terminal (optional) Notes: 1. able Ø 6 mm, Red = +24 V Green = 0 V Black = -24 V 2. An aditional M4 terminal is placed when the EM shield option is selected (maximum torque value 2.2 Nm) 3. Fastening: 4 slots black marked Ø 4.3 mm for horizontal mounting and 4 slots black marked Ø 4.3 mm for vertical mounting 4. To obtain a positive output on the terminal marked M, primary current must flow in the direction of the arrow (conventional flow) 5. Temperature of the primary conductor should not exceed 100 o 6. General tolerances are + 0.5 mm, with exception of the input/output positions + 1 mm, length + 1 mm and on positions where the value is mentioned in the drawing 7. Drawing is according the European projection method 6

Dimensions (mm) M5 terminals EM shield terminal (optional) Notes: 1. onnection: 3 x M5 terminals, maximum torque value 2.2 Nm A 4th M5 terminal is placed when the EM shield option is selected (maximum torque value 2.2 Nm) 2. Fastening: 4 slots black marked Ø 4.3 mm for horizontal mounting and 4 slots black marked Ø 4.3 mm for vertical mounting 3. To obtain a positive output on the terminal marked M, primary current must flow in the direction of the arrow (conventional flow) 4. Temperature of the primary conductor should not exceed 100 o 5. General tolerances are + 0.5 mm, with exception of the input/output positions + 1 mm, length + 1 mm and on positions where the value is mentioned in the drawing 6. Drawing is according the European projection method 7

Dimensions (mm) Trim trio SMS 6 PDH1 connector Notes: 1. onnection trim trio SMS 6 PDH1 2. Fastening: 4 slots black marked Ø 4.3 mm for horizontal mounting and 4 slots black marked Ø 4.3 mm for vertical mounting 3. To obtain a positive output on the terminal marked M, primary current must flow in the direction of the arrow (conventional flow) 4. Temperature of the primary conductor should not exceed 100 o 5. General tolerances are + 0.5 mm, with exception of the input/output positions + 1 mm, length + 1 mm and on positions where the value is mentioned in the drawing 8

Dimensions (mm) Primary bus bar Notes: 1. onnection: 4 x M5 terminals, primary 6 x 25 mm busbar 2. Fastening: 2 slots of Ø 4.3 mm for horizontal mounting and 4 slots black marked Ø 4.3 mm for wall mounting 3. To obtain a positive output on the terminal marked M, primary current must flow in the direction of the arrow (conventional flow) 4. Temperature of the primary conductor should not exceed 100 o 5. General tolerances are + 0.3 mm, with exception of the input/output positions + 1 mm length + 1 mm and on positions where the value is mentioned in the drawing 6. Installation with a primary busbar: the sensor must be mechanically fixed only by the bar but not both bar and housing at the same time (this type of fixing would lead to mechanical stress that could lead to breaking of the sensor). 9

Notes 10

Ordering scheme onfiguration: MSA500 - S - 4 - D - 3-2 - 4 - Y 1. 2. 3. 4. 5. 6. 7 8. This example represents a MSA500-S-4-D-3-2-4-Y. Description: MSA500 transducer, with hole for the primary, conversion ratio 1:4000, M5 terminals, dielectric strength 10 kv, 0.5% accuracy, -50 o...+85 o temperature range, with EM shield. 1. Transducer model MSA500 2. Mounting 5. Dielectric strength S T With hole for the primary With primary busbar 2 6 kv 3 10 kv 3. onversion ratio 4 1:4000 5 1:5000 6. Accuracy 1 1 % 2 0.5 % 4. Secondary connection 7. Temperature range A B D I M4 terminals 6.35 mm faston Flying lead terminals M5 terminals Trim trio SMS 6 PDH1 3-40 o...+85 o 4-50 o...+85 o 8. EM shield * N Y Without EM shield With EM shield 11

DS-MSA500 V4.9 March 2013 Mors Smitt France SAS Tour Rosny 2, Avenue du Général de Gaulle, F - 93118 Rosny-sous-Bois edex, FRANE T +33 (0)1 4812 1440, F +33 (0)1 4855 9001 E sales@msrelais.com Mors Smitt Asia Ltd. # 807, Billion Trade entre, 31 Hung To Road Kwun Tong, Kowloon, HONG KONG SAR T +852 2343 5555, F +852 2343 6555 E info@morssmitt.hk Mors Smitt B.V. Vrieslantlaan 6, 3526 AA Utrecht, NETHERLANDS T +31 (0)30 288 1311, F +31 (0)30 289 8816 E sales@nieaf-smitt.nl Mors Smitt Technologies Inc. 420 Sackett Point Road North Haven, T 06473, USA T +1 (203) 287 8858, F +1 (888) 287 8852 E mstechnologies@msrelais.com Mors Smitt UK Ltd. Doulton Road, radley Heath West Midlands, B64 5QB, UK T +44 (0)1384 567 755, F +44 (0)1384 567 710 E info@morssmitt.co.uk (c) opyright 2013 All rights reserved. Nothing from this edition may be multiplied, or made public in any form or manner, either electronically, mechanically, by photocopying, recording, or in any manner, without prior written consent from Mors Smitt. This also applies to accompanying drawings and diagrams. Due to a policy of continuous development Mors Smitt reserves the right to alter the equipment specification and description outlined in this datasheet without prior notice and no part of this publication shall be deemed to be part of any contract for the equipment unless specifically referred to as an inclusion within such contract.