Installation Instructions For Aurora Halogen Accent Housing 3 Round & Square Trimless AH1-ARE, AH1-ARB, AH1-ASE, AH1-ASB. Fig.

Similar documents
Installation Instructions For Aurora Halogen Accent Housing 3 Round & Square Trimless AH2-ARE3 & AH2-ASE3. Fig.1 Complete Fixture

Installation Instructions For Aurora Dual MR16 Round & Square Edge 3.3" Fig.1 Complete Fixture ADJUSTABLE GEARS HIDDEN BEHIND THE LAMP PAN LOCK

Installation Instructions For Aurora Halogen Accent Housing 3 Round & Square Trimless AH2-ARE3 & AH2-ASE3. Fig.1 Complete Fixture

AURORA HALOGEN ACCENT HOUSING 3 ROUND AND SQUARE TRIMLESS AH3-ARE3-RBG & AH3-ASE3-RGB INSTALLATION INSTRUCTIONS

Installation Instructions For Aurora Halogen Accent Housing 3 Round & Square Trimless AH3-ARE3-RGB & AH3-ASE3-RGB. Fig.

Round or Square Type IC Wall Wash Housing with Lamp for Flangeless Trims

Install the Housing. Installation Instructions for Entra Round or Square Type IC, Air-tight New Construction Adjustable LED Housing EN3_-LH9_ 1.

Installation Instructions For TruLine 1.6A 24VDC

Installation Instructions for TruLine 1.6A 24VDC. Section One: Basic Configuration Options

Multiples EM_ 1.4. Install 1X1/1X2/1X3/1X4 Housings. Installation Instructions for. This product is suitable for indoor locations.

Round or Square Chicago Plenum Down Light Housing with Lamp

Round or Square Type IC Down Light Housing with LED Lamp for Flangeless Trims E3_L_-L_DI 1.4

INSTALLATION INSTRUCTION Silo Multiples - New Construction Housing MT-4*15, MT-4*10

INSTALLATION INSTRUCTIONS FOR FLUSH MOUNT FIXTURES

Installation Instructions For Reveal

Lightplane 3.5 Recessed

Installing Fixture Using Remote Power Supply

2. Connect driver to power source leads. After connections are made, place driver above ceiling. SEE MINIMUM SPACE REQUIREMENTS BELOW.

INSTALLATION INSTRUCTIONS FOR FLUSH MOUNT FIXTURES

Inde-Pendants Family. 32L Ring Plaster Trim, Grid and Drywall Ceiling Types. Document No Installation instructions for 32L-Rxx-P

Installation Instructions for DIY or Completed 45 Degree Light Channel

Inde-Pendants Family. 32L Surface Mount Cylinder with Ring Plaster Trim, Grid and Drywall Ceiling Types. Document No

INDIVIDUAL MOUNTING: T-Bar

Inde-Pendants Family. 32L Surface Mount Cylinder Plaster Trim, Grid and Drywall Ceiling Types. Document No

DOWNLIGHT LED SERIES INSTALLATION INSTRUCTIONS

LED RECESSED ADJUSTABLE 3-1/4 APERTURE Non-IC Rated, 1000 LUMEN TC49L, TC949L

Installation Instructions Standalone or continuous run configurations - 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS

Installation Instructions for DIY or Completed Light Channel.6 Millwork

Installation Instructions For Reveal Light Channel

with Lamp Install the Housing with Adjustable Bars Installation Instructions for LED E3_-L_DN 1.1 ½ to ¾ ¾ or thicker

EXPLODED VIEW AND PART CALL OUT ASSEMBLING THE METALUX DF SERIES FRAME KIT

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

Installation Instruction

PORTA~TRACE. GAGNE, INC. 41 Commercial Dr. Johnson City, New York Phone: Fax: ASSEMBLY INSTRUCTIONS

Prepare the Fixture. Sage 37 Bath. Back Plate Installation (Horizontal) Installation Instructions for 700BCSAGW37_

5 ACCESS PANEL INSTALLATION SPACER *SLIDE TO LOCATION OF FASTENER DURING INSTALLATION OF EACH FASTENER

Installation Instructions for Cirrus Suspension Downlight with Power - End Feed. Section One: 4" Flush Canopy Version

INSTALLATION RECOMMENDATIONS For The Con-Tech ODYSSEY Line Voltage Flexible Track System

Installation Instructions for Zip Suspension Downlight with Remote Power and 4" Square or Round Canopy

Line volt rail & fixtures. Low volt quick connect fixtures with transformers

B235 Mobius Sconce Page 1 of 6

3-1/4 LED RECESSED ADJUSTABLE AND DOWNLIGHT 800/1200/1500/2000 LUMEN SQUARE APERTURE NEW CONSTRUCTION IC/TC420LSQ, IC415LSQ, IC412LSQ, IC408LSQ

INSTALLATION INSTRUCTIONS Oculux 3.5 Architectural Remodel

- 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS. Factory pre-installed mud flange TOOLS REQUIRED: Phillips screwdriver, 5/16 nut driver.

INS T A L L A TIO N INS T R U C TIO N S. Ceiling Mount Track System

3-1/4 LED RECESSED ADJUSTABLE AND DOWNLIGHT 800/1200 LUMEN ROUND APERTURE REMODEL IC408LR, TC412LR

Joiner Kit Joiner bracket (x1) Biscuit aligners (x2) Trim Flange

PMT-L31 (for Low Ceilings) PMT-H35 (for High Ceilings)

RAIL 4 PERIMETER RP4D RECESSED T-BAR LED TELESCOPIC, INTEGRAL DRIVER

Closet Carousel Installation Instructions. Models TKA 5 Through TKA 14 Equipped with Footswitch Controls

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

TIP FOR GETTING STARTED

INSTALLATION INSTRUCTION Indirect Recessed Channel

SM-RAZOR-T-M/L/XL. Strong Low Profile Tilt Mount for Ultra-Thin Flat-Panel TVs INSTRUCTION MANUAL

3% VOLTAGE DROP. Installation Instructions for 400 Watt 24 Volt DC RGB DMX LED Power Supply SAVE THESE INSTRUCTIONS!

BLACK BODY DIMMING & TUNABLE WHITE 1000 LUMEN ADJUSTABLE, DOWNLIGHT AND WALL WASH LED ROUND APERTURE IC410T, TC410T P1.16.0

TASK: Replace Control Mechanism/Drive End for G71 Supervue/Everglide Vertical headrail

GLASS GLOBE MOBILE LINEAR CHANDELIER

INSTALLATION MANUAL PBL-UMP

INSTALLATION INSTRUCTIONS

Inigo Sconce INSTALLATION INSTRUCTIONS P _2_A 1 of 5

Installation Instructions for TruLine 1A Center Feed Power Channel Connector

INSTALLATION AND CARE INSTRUCTIONS

Installation Instructions. Oakmont Folding Doors

DRYWALL CEILING SPLINE KICKER REFLECTOR DIFFUSER LENGTH TABLE DIFFUSER LENGTH TABLE DESCRIPTION 2' IND 3' IND 4' IND 6' IND 8' IND

REGOLO GENERAL WARNING

INSTALLATION MANUAL PBC-UMS

mila-wall (Series100) General Operating Instructions page 1 of 15

Figure A. Figure B. Figure C. Figure D

RAIL 4 INSTALLATION INSTRUCTIONS. RM4DOD Recessed GENERAL SAFETY INSTRUCTIONS: NOTE:

INSTALLATION AND CARE INSTRUCTIONS

General Installation Instructions LED

Assembly and Installation Guide

4.5 LED RECESSED FLUSH TRIM

C 0.05" ALLEN WRENCH. Installation Instructions for Cirrus Channel Suspension T1 with 4" Square or Round Canopy. Section One: Adjusting Cable Position

J-BOX. 3-O or 4-0 MUD RING J-BOX BRACKET BAR CABLE GRIPPER/ CANOPY MOUNTING STUD 8-32 BRACKET BAR SCREWS CANOPY STRAIN RELIEF POWER CORD CANOPY

Vertical Honeycomb Shades

GLASS GLOBE MOBILE 6-ARM CHANDELIER

Installation Instructions

General Installation Instructions

INSTALLATION INSTRUCTIONS SMALL FLAT PANEL ADJUSTABLE PITCH WALL MOUNT Model: FTR Series

INSTALLATION INSTRUCTIONS Xenix Incandescent Series XN12, XN24, XN36, XN48

TITAN2-EDGE Public Access Computer Station Dual Track

INSTALLATION: D1-NOTCH DRYWALL TRIM FLANGE

Aliante Installation. Components included: Tools required: Not Included:

MyStudio VS53 Versa Sweep Setup Instructions

Ø1.80 (46) Aperture Lens Location. Ball Catch Retainers

F5513 APOGEE 30"DIA 3LTS PENDANT INSTALLATION INSTRUCTIONS WARNING

Replacing the Reciprocator on an SWF Multi-head.

LOW PROFILE 3-1/4 LED RECESSED ADJUSTABLE, DOWNLIGHT AND WALL WASH 800/1200/1500/2000 LUMEN ROUND APERTURE TC420LP, IC415LP, IC412LP, IC408LP

INSTALLATION INSTRUCTION OCULUX 3 LED - New Construction

SLOT INSTALLATION GUIDE Indoor IP20

END FEED INSTALLATION

flat panel solutions Specifications Box contents Warnings CAUTION: Tilt Wall Mount for LCD, Plasma, and LED Displays Instruction Manual

Installation and Assembly: In-wall Mount for 32" to 71" Flat Panel Screens

Installing your new Bevella Top. L Shaped Countertop with Joints No Finished Ends (Fits Between Four Walls)

Connecting the Channel A

PMT-L11 (for Low Ceilings) PMT-H15 (for High Ceilings)

Custom Pendant- Hardwire Assembly and Installation Instructions

INSTALLATION INSTRUCTIONS

Transcription:

2015 Pure Lighting. All Rights Reserved. Installation Instructions For Aurora Halogen Accent Housing 3 Round & Square Trimless AH1-ARE, AH1-ARB, AH1-ASE, AH1-ASB 1718 W. Fullerton Ave Chicago, IL 60614 Tel: 773-770-1195 Fax: 773-935-5613 www.purelighting.com info@purelighting.com General Information Fixture must be installed by a qualified electrician (check with local and national codes for proper installation). To prevent electrical shock, disconnect electrical supply before installation or servicing. Compatible only with traditional, level 5 surface finishing, not self-leveling, PVA primer systems. Fig.1 Complete Fixture 6 1/16" (154mm) HOUSING ANCHOR SCREENS WORKFLOW CHART 1. Locate and mount housing 2. Screw and lock-in housing 3. Connect wires un housing 5 7/8" (149mm) 18 1/2" (470mm) 8 7/8" (225mm) 12 1/8" (307mm) PLASTER PLATE CONTRACTOR 1. Install and cut drywall around housing. ADJUSTABLE GEARS HIDDEN BEHIND THE LAMP. BACK LIGHT SHIELD 1. Adjust plaster flange frame and tighten wing nuts. 2. Connect the MR16 and LEDS wiring to the plaster plate. 3. Screw plaster plate into housing. 4. Test MR16 and LEDs. CONTRACTOR 1. Plaster, sand & paint. 2. Clean aperture with clean damp towel. 1. Clean aperture with clean damp towel, where the drywall contractor missed. 2. Adjust pan rotation ring and aim lamp. You're done! TILT GEAR Fig.2 Pan tilt Mechanism attached to inside of plaster plate. HOT AIMING TILT SCREW Fig.3 Snoot Assembly HOT AIMING WITH PHILLIPS SCREWDRIVER LIGHT SPILL SHIELD 5 BULLET CATCHES SNOOT RETAINING RING LOCKING RING (INCLUDED) MR16 HALOGEN LAMP ONLY LOCKING RING (INCLUDED) PAN LOCK PAN ROTATION RING SOFT FOCUS LENS (INCLUDED) LENS (OPTIONAL) LOUVER (OPTIONAL) SNOOT LAMP HOLDER 1

A ANCHOR SCREENS 5 7/8" (149mm) 14 3/4" (375mm) 8 7/8" (226mm) ALIGNMENT NOTCH 1 2 B NOTE: APERTURE IS CENTERED WITH CURVES IN HOUSING. (NOT CENTER IN FIXTURE) NOTE: APERTURE IS CENTERED WITH CURVES IN HOUSING. ALIGNMENT NOTCH 12 1/8" (308mm) MUST BE FLUSH WITH JOIST 2 1: Use these dimensions when locating the center point of the aperture during the installation process. Align the fixture using a laser or a chalk line. NOTE: Drywall anchor screens may be removed, if the joist are less than 14 1/2" apart. Refer to page 8 to shorten the hanger bars, 2: Hanger bars must align and remain flush with joist. C D 4 REMODEL NOTE: CUT TO MIDDLE OF JOIST. 3 3: After fixture is positioned, tighten all (10) screws on hanger bars. 4: After installation, pull on fixture to ensure there is no movement. 2

E LINE INPUT 120V - 240V INSIDE AURORA JUNCTION BOX (NOT TO SCALE) - Neutral TO NEXT FIXTURE + Dimmable Switchleg *NOTE* Leave 12" of wire in the junction box for future maintenance through the f ixture aperture. Make sure the wires nut connections are tight. MAGNETIC LOW VOLTAGE DIMMER INSIDE AURORA FIXTURE 120V 75W MAGNETIC TRANSFORMER (240V ELECTRONIC TRANSFORMER FOR EUROPE) MR16 LAMP WIRING DIAGRAM FOR USE WITH PURE LIGHTING AURORA NON-RGB FIXTURES 3

CONTRACTOR F G ANCHOR SCREEN CUTOUT 7 8 ROTARY TOOL 7: Drywall contractor must install drywall and cut 14 3/4" (375mm) X 12 1/8" (308mm) hole with rotary cutting tool around fixture or pre-cut hole in drywall prior to installation. Contratista hojas de pared tiene que instalar la hoja de pared y corte un aqujero 14 3/4" (375mm) X 12 1/8" (308mm) con une corte rotatorio alrededor el enseres fijo o lo corte un agujero antes que instalar. ANCHOR SCREW 8: Electrian must anchor drywall anchor screens. Insert screws through drywall into anchor screen on fixture. H I CEILING 9 PLASTER FLANGE FRAME LOOSEN WINGNUTS TO ADJUST PLASTER FLANGE FRAME 10 9: Loosen (4) wing nuts and adjust plaster flange frame to be flush with drywall. All 4 corners MUST be exactly even with drywall. Plaster flange frame adjusts to accommodate 1/2" (13mm) to 1 1/4" (32mm) ceiling thickness. 10: Use a straight edge or level and move plaster flange frame up or down to be exactly even with drywall ceiling. 4

J TIGHTEN WINGNUTS TO ADJUST PLASTER FLANGE FRAME 11 K 11 USE A PEN TO TIGHTEN LOCKING RINGS. 10 LAMP LOCKING RING LOUVER AND LENS LOCKING RING SNOOT LAMP HOLDER 11: Tighten (4) wing nuts securely. 12: Assemble lamp holder fixture to MR16 socket. Use a pen to tighten locking rings into place. L M 13 14 13: Loosely attach plaster plate using all (4) screws. After all (4) screws are started, go back and tighten the screws securely. 14: Check to ensure that the plaster plate is flush and even with the drywall. 5

N O 15 MR16 HALOGEN ACCENT LIGHT (NO MR16 LED) 16 HANDS MUST BE CLEAN WHEN ADJUSTING FIXTURE 15: Turn on and test MR16 and LEDs to ensure they are properly installed. 16: To aim lamp, loosen pan lock, rotate and position the pan rotation ring. P Q OPEN SPACE ON RACK 18 GEAR COVER 17 19 20 TOP CLIP HANDS MUST BE CLEAN WHEN ADJUSTING FIXTURE BOTTOM CLIP 17: Tilt and rotate MR16 as needed. When lamp is properly adjusted secure pan lock. 18: Measure the distance of the open space on the track. 19: Remove the protective film from the gear cover. 20: Cut the gear cover to fit the space if necessary. 6

R 21 APERTURE S CONTRACTOR Compatible only with traditional, level 5 surface finishing, not self-leveling, PVA primer systems. RACK GEAR COVER 22 GEAR COVER RACK 22 Aplicar incluido Perfect Finish FibaTape Ultra-Thin Tape alrededer de los cuatro lados 21: Insert the gear cover (make sure the gear cover clips are facing the lamp assembly rack) from the bottom of the aperture. 23: Apply included Perfect Finish FibaTape Ultra-Thin Drywall Tape around all four sides of the plaster plate. DO NOT OVERLAP. 22: Secure by snapping in the two bottom clips of the gear cover first to the bottom edge, then snap in the top two clips to the top edge. T U 24 23 Aplique una capa delgada de Durabond 45 compuesto alrededor de todo cuatro lados de la placa de yeso Lijar superficie de yeso. Repita según sea necesario hasta que la superficie es totalmente lisa antes de pintar. 24: Apply a thin layer of Durabond 45 compound around all four sides of the plaster plate. 25: Sand plastered surface. Repeat as needed until surface is completely smooth before painting. 7

V W 27 HANDS MUST BE CLEAN WHEN ADJUSTING FIXTURE 26: Paint and finish plaster plate and wall. Remove paint shield from plaster plate 20-60 minutes after painting. 27 27: Clean all excess paint from the aperture. 28: Wash hands and clean all drywall residue from inside aperture, with a clean damp towel. Electrician or lighting designer - ensure pan rotation ring is adjusted, locked in place, and the lamp is aimed properly. SHORTENING THE HANGER BARS (ONLY FOR JOISTS SPACED LESS THAN 14.5") X HOUSING Y HOUSING HANGER ARM HANGER ARM 1 1 2 2 1 1 HANGER ARM 3 ANCHOR SCREEN 3 PHILLIPS SCREW 1: Remove the four Phillip screws on the housing to remove the two anchor screens, and put the screws back on. 2: Pull the hanger arms completely out of the housing. 3: Break the ends completely off hanger arms. 8

Z HOUSING HANGER ARM 4 4 4: Insert the hanger arms back into the housing, and continue to step A on page 2 to complete instillation. 9