Implementation of SRF based Multilevel Shunt Active Filter for Harmonic Control

Similar documents
Control Of Shunt Active Filter Based On Instantaneous Power Theory

A Novel FPGA based PWM Active Power Filter for Harmonics Elimination in Power System

Design and Simulation of Three Phase Shunt Active Power Filter Using SRF Theory

PLL Synchronization with PID Controller Based Shunt Active Power Line Conditioners

Cascaded Multilevel Inverter based Active Filter for Power Line Conditioners using Instantaneous mitigates

PI Controller Based Shunt Active Power Filter with Cascaded Multilevel Inverter

PI-VPI Based Current Control Strategy to Improve the Performance of Shunt Active Power Filter

Power Quality Improvement using Shunt Passive Filter

ANALYSIS OF SYNCHRONOUS-REFERENCE-FRAME-BASED CONTROL METHOD FOR UPQC UNDER UNBALANCED AND DISTORTED LOAD CONDITIONS Salava Nagaraju* 1

Three Phase Active Shunt Power Filter with Simple Control in PSIM Simulation

ABSTRACT I. INTRODUCTION

Sinusoidal Current Control based Shunt Active Power Filter for Current Harmonics Reduction

Simulation of Three Phase Cascaded H Bridge Inverter for Power Conditioning Using Solar Photovoltaic System

ISSN: Page 20. International Journal of Engineering Trends and Technology- Volume2Issue3-2011

Three Phase PFC and Harmonic Mitigation Using Buck Boost Converter Topology

Power Quality improvement of a three phase four wire system using UPQC

KKR &KSR institute of Technology and sciences,vinjanampadu(v),vatticherukuru(m) Guntur(D) , Andhra Pradesh,India. I.

DESIGN AND DEVELOPMENT OF ACTIVE POWER FILTER FOR HARMONIC MINIMIZATION USING SYNCHRONOUS REFERENCE FRAME (SRF)

MODELLING & SIMULATION OF ACTIVE SHUNT FILTER FOR COMPENSATION OF SYSTEM HARMONICS

Improvement of Power Quality Using Hybrid Active Power Filter in Three- Phase Three- Wire System Applied to Induction Drive

IJSRD - International Journal for Scientific Research & Development Vol. 2, Issue 06, 2014 ISSN (online):

A Simple Control Algorithm for Three-Phase Shunt Active Power Filter for Reactive Power and Current Harmonic Compensation

Analysis of Reference Current Generation for Shunt Active Power Filter Using SRF Algorithm to Compensate Harmonic Current

Assessment of Different Compensation Strategies in Hybrid Active Power Filters

Comparison of Various Reference Current Generation Techniques for Performance Analysis of Shunt Active Power Filter using MATLAB Simulation

IJSTE - International Journal of Science Technology & Engineering Volume 2 Issue 12 June 2016 ISSN (online): X

Indirect Current Control of LCL Based Shunt Active Power Filter

PERFORMANCE ANALYSIS OF SVPWM AND FUZZY CONTROLLED HYBRID ACTIVE POWER FILTER

International Journal of Advance Research in Engineering, Science & Technology

ISSN Vol.03,Issue.07, August-2015, Pages:

Design of Shunt Active Power Filter by using An Advanced Current Control Strategy

Mitigation of Line Current Harmonics Using Shunt Active Filter With Instantaneous Real and Reactive Power Theory

Comparison of Reference Current Extraction Methods for Shunt Active Power Filters

CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS

Cascaded H-Bridge Five Level Inverter for Harmonics Mitigation and Reactive Power Control

Synchronous Reference Frame Theory For Nonlinear Loads using Mat-lab Simulink

ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 3, May 2013

INSTANTANEOUS POWER CONTROL OF D-STATCOM FOR ENHANCEMENT OF THE STEADY-STATE PERFORMANCE

Simulation Study of PWM Techniques for Voltage Source Converters

Chapter 2 Shunt Active Power Filter

HYSTERESIS CONTROL FOR CURRENT HARMONICS SUPPRESSION USING SHUNT ACTIVE FILTER. Rajesh Kr. Ahuja

DRIVE FRONT END HARMONIC COMPENSATOR BASED ON ACTIVE RECTIFIER WITH LCL FILTER

SIMULATION AND COMPARISON OF SPWM AND SVPWM CONTROL FOR TWO LEVEL UPQC

Load Compensation at a Reduced DC Link Voltage by Using DSTATCOM with Non-Stiff Source

Size Selection Of Energy Storing Elements For A Cascade Multilevel Inverter STATCOM

Shunt Active Power Filter based on SRF theory and Hysteresis Band Current Controller under different Load conditions

Synchronous Reference Frame Control Algorithm Based Four -Leg Inverter DSTATCOM For Power Quality Improvement

Mitigation of Flicker Sources & Power Quality Improvement by Using Cascaded Multi-Level Converter Based DSTATCOM

CHAPTER 4 PV-UPQC BASED HARMONICS REDUCTION IN POWER DISTRIBUTION SYSTEMS

Design of a Hybrid Active Filter for Harmonics Suppression in Industrial Facilities

Fuzzy Logic Control of APF for Harmonic Voltage Suppression in Distribution System

SHUNT ACTIVE POWER FILTER

INVESTIGATION OF HARMONIC DETECTION TECHNIQUES FOR SHUNT ACTIVE POWER FILTER

DESIGN AND IMPLEMENTATION OF THREE PHASE SHUNT APF CURRENT CONTROLLER WITH ANN TECHNIQUE

Mitigation of Current Harmonics with Combined p-q and Id-IqControl Strategies for Fuzzy Controller Based 3Phase 4Wire Shunt Active Filter

Shunt Active Power Filter for Compensation of System Harmonics

Modeling and Simulation of SRF and P-Q based Control DSTATCOM

A Hysteresis based Active Shunt, Passive Series Hybrid Filter for Power Quality Improvement

Delhi Technological University (formerly DCE) Delhi-42, India

CHAPTER 6 UNIT VECTOR GENERATION FOR DETECTING VOLTAGE ANGLE

HYBRID ACTIVE FILTER FOR REDUCTION OF CURRENT HARMONICS IN THREE PHASE SYSTEM USING SYNCHRONOUS REFERENCE FRAME THEORY

NEUTRAL CURRENT COMPENSATION USING FOUR LEG SHUNT ACTIVE POWER FILTER

Available online at ScienceDirect. Procedia Technology 21 (2015 ) SMART GRID Technologies, August 6-8, 2015

Harmonics Reduction using 4-Leg Shunt Active Power Filters

PSPWM Control Strategy and SRF Method of Cascaded H-Bridge MLI based DSTATCOM for Enhancement of Power Quality

A Reduction of harmonics at the Interface of Distribution and Transmission Systems by using Current Source active Power Filter

Mitigation of Voltage Sag/Swell Using UPQC

Unit Vector Theory based Unified Power Quality Conditioner for Power Quality Improvement

Modular Grid Connected Photovoltaic System with New Multilevel Inverter

ICCCES Application of D-STATCOM for load compensation with non-stiff sources

Compensation of Harmonics Power by using Shunt Active Filter


Literature Review for Shunt Active Power Filters

Chapter 4. Hybrid series active filter. 4.1 Introduction

Investigation of D-Statcom Operation in Electric Distribution System

Level Shifted Pulse Width Modulation in Three Phase Multilevel Inverter for Power Quality Improvement

SCIENCE & TECHNOLOGY

MODELING AND ANALYSIS OF IMPEDANCE NETWORK VOLTAGE SOURCE CONVERTER FED TO INDUSTRIAL DRIVES

Application of Fuzzy Logic Controller in Shunt Active Power Filter

Three-Level Shunt Active Filter Compensating Harmonics and Reactive Power

Modified Three-Phase Four-Wire UPQC Topology with Reduced DC-Link Voltage Rating

Multi Level Inverter Based Active Power Filter for Harmonic Reduction

Comparison of Control Algorithms for Shunt Active Filter for Harmonic Mitigation

Ripple Reduction Using Seven-Level Shunt Active Power Filter for High-Power Drives

A Current-Source Active Power Filter with a New DC Filter Structure

Power Quality Improvement of Unified Power Quality Conditioner Using Reference Signal Generation Method

Performance Analysis of Shunt Active Power Filter Base On Active Reactive Power Theory

STATCOM with FLC and Pi Controller for a Three-Phase SEIG Feeding Single-Phase Loads

HYBRID ACTIVE FILTER WITH VARIABLE CONDUCTANCE FOR HARMONIC RESONANCE SUPPRESSION USING ANN

Power Quality Improvement of Distribution Network for Non-Linear Loads using Inductive Active Filtering Method Suresh Reddy D 1 Chidananda G Yajaman 2

2020 P a g e. Figure.2: Line diagram of series active power filter.

Modeling & Simulation of Micro Grid Distribution System to reduce Harmonics Using Active Power Filters and PI controllers

A MATLAB-SIMULINK APPROACH TO SHUNT ACTIVE POWER FILTERS

CHAPTER 4 DESIGN OF DC LINK VOLTAGE CONTROLLER FOR SHUNT ACTIVE POWER FILTER

Comparison of Shunt Active Power Filter Control Strategies for Harmonic Compensation in a Paper Industrial Factory

A Static Synchronous Compensator for Reactive Power Compensation under Distorted Mains Voltage Conditions

Australian Journal of Basic and Applied Sciences. Simulation and Analysis of Closed loop Control of Multilevel Inverter fed AC Drives

Design and Simulation of Fuzzy Logic controller for DSTATCOM In Power System

SHUNT COMPENSATOR USED FOR POWER QUALITY IMPROVEMENT

Field Programmable Gate Array (FPGA) Based Pulse Width Modulation for Single Phase Hybrid Active Power Filters U. Krishna Reddy 1 Ch.

Transcription:

International Journal of Engineering Research and Development e-issn: 2278-067X, p-issn: 2278-800X, www.ijerd.com Volume 3, Issue 8 (September 2012), PP. 16-20 Implementation of SRF based Multilevel Shunt Active Filter for Harmonic Control Vijayasree.J 1, Vijayakrishna.B 2, Y.Rajesh Babu 3 1 Dept of EEE, Bapatla Engg College 2 lecturer, Dept of EEE, Bapatla Engg College 3 Assistant Professor, Dept of EEE, Narasaraopet Engg College Abstract In this paper a power line conditioner using a cascaded multilevel inverter based shunt active filter using synchronous reference frame (SRF) controller is developed to improve the power quality in the distribution system. The cascaded multilevel inverter consists of two H bridges in which each bridge has separate dc source. Gating signals to the cascaded multilevel voltage source inverter are generated from proposed triangular-periodical current controller. Here control strategy is different from conventional methods and provides superior performance. Using Reference Frame Transformation, the current is transformed from a b c stationery frame to rotating 0 d q frame. Using the PI controller, the current in the 0 d q frame is controlled to get the desired reference signal. From simulation results observed that the cascaded multilevel inverter based shunt active filter effectively compensates the current harmonics. Keywords Power line conditioner, Synchronous reference frame controller, triangular carrier current controller, power quality. I. INTRODUCTION The increased use of nonlinear devices in industry has resulted in direct increase of harmonic distortion in the industrial power system in recent years. Conventionally, this problem can be solved by using passive filters whose main components are inductors and capacitors. Although this kind of filter has the advantage of low hardware cost, the performance of this configuration is often significantly affected by system impedance and load characteristics. With the emergence of power electronics, an active power filter that helps to suppress the harmonics and improves the power quality. This proposal was mainly based on the theory of harmonic current injection. In the circuit operation. The current-controlled power converter generates the harmonic current that is opposite to the load harmonic current injecting into the power feeders. Hence, the current harmonics can be effectively suppressed and only the fundamental component of load current is extracted. In other words, the active power filter can also be regarded as a harmonic current source that is allocated in parallel with the power system. Therefore the notorious resonance problems can be easily avoided. However, because the switching frequency of the power ratings, the design of active power filters power converter is inversely proportional to for high-power applications should be made carefully. This paper presents a synchronous reference frame controller based cascaded shunt active power filter for the harmonics and reactive power mitigation of the non-linear loads. The cascaded H-bridge active filter has been applied for power quality applications due to increase in number of voltage levels, low switching losses and higher order of harmonic elimination. The cascade M-level inverter consists of (M-1)/2 H-bridges and each bridge has its own separate dc source. The cascaded voltage source inverter switching signals are generated using proposed triangular periodical current controller; it provides better dynamic performance under both transient and steady state conditions. The compensation process is based sensing load currents only, which require current harmonics and reactive power elimination due to the loads. The PIcontroller is used to maintain the capacitance voltage of the cascaded inverter constant. II. DESIGN OF SHUNT APLC SYSTEM The shunt APLC system contains a cascaded multilevel inverter, RL-filters, a compensation controller (synchronous reference frame controller) and switching signal generator (triangular-periodical current controller) as shown in the Fig 1. Fig1: Shunt Active Power line Conditioners System.Three phase supply source connected with the non-linear load. 16

The parallel active filter approach is based on the principle of injection of load harmonic currents and hence is characterized by non sinusoidal current reference tracking and high current regulator bandwidth requirement. The parallel active filter is controlled as a harmonic current source and requires a suitable controller for extraction of load harmonic currents and an appropriate current regulator. The nonlinear load current should contain fundamental component and harmonic current components. For harmonic compensation, the active filter must provide the compensation Currentti c (t)=i L (t)-i S (t). III. MULTI LEVEL INVERTER Fig2: Cascaded Multilevel Active Power Filter The three-phase active filter comprises of 24-power transistors and each phase consists of two-h-bridges in cascaded method for 5-level output voltage shown in Fig 2. Each H-bridge is connected a separate dc capacitor and it serves as an energy storage element. A cascade M-level inverter consists of (M-1)/ H bridges in ts to supply a real power difference between load and source during the transient period. The capacitor voltage is maintained constant using PI-controller and the output voltage is Vdc. The 24-power transistors switching operations are performed using proposed triangular-periodical current controller and harmonics is achieved by injecting equal but opposite current harmonic components at point of common coupling (PCC). IV. PROPOSED CONTROLLERS SRF method is used to generate reference signals and triangular-periodical current controller is used for generating switching signals to cascaded VSI. A). SRF Control Method The synchronous reference frame theory is developed in time-domain based reference current generation techniques. The conventional SRF method can be used to extract the harmonics contained in the supply voltages or currents. For current harmonic compensation, the distorted currents are first transferred into two-phase stationary coordinates using α β transformation (same as in p q theory).after that, the stationary frame quantities are transferred into synchronous rotating frames using cosine and sinus functions from the phase-locked loop (PLL). The sine and cosine functions help to maintain the synchronization with supply voltage and current.. The conventional SRF algorithm is also known as d q method, and it is based on a b c to d q 0 transformation (park transformation), which is proposed for active filter compensation. This proposed algorithm derivate from a three-phase stationary coordinate load current ila, ilb, ilc are convert to id-iq rotating coordinate current, as follows i d= 2 3 [i La sin(ωt) +ilb sin(ωt 2π 3 ) + ilcsin(ωt + 2π 3 ) ] (1) i q= 2 3 [ila sin(ωt) +ilb sin(ωt 2π 3 ) + ilcsin(ωt + 2π 3 ) ] (2) Here the Proportional Integral (PI) controller is used to eliminate the steady state error of the DC-component of the cascaded multilevel inverter and maintains the dc-side capacitor voltage constant Fig3: Synchronous Reference Frame Controller The dc capacitor voltage is sensed and compared with reference voltage to calculate the error voltage. These error voltage involved the P-I gain (KP=0.1 and KI=1) for regulate the capacitance voltage in the dynamic conditions. In accordance to the PI controller output is subtracted from the direct axis (d axis) of harmonic component for eliminate the steady state error. Similar to the p q theory, using filters, the harmonics and fundamental components are separated easily and transferred back to the a b c frame as reference signals for the filter. 17

I * sa = i d sin(ωt) + iq cos(wt) (3) I * sb = i d sin(ωt 2π ) 3 + iq cos(wt 2π ) 3 (4) I sb * = i d sin(ωt + 2π 3 ) + iq cos(wt + 2π 3 ) (5) b) PI Controller The DC side capacitor voltage is sensed and compared with a desired reference voltage. Fig 4 : PI Controller Figure 4 shows the block diagram of the proportional integral control scheme for the active Power filter. The DC side capacitor voltage is sensed and compared with a desired reference voltage. The voltage error e=v dc,ref -V dc at the n th sampling instant is used as an input for PI controller. The error signal passes through Butterworth Low Pass Filter (LPF). The LPF filter has cutoff frequency at 50 Hz that can suppress the higher order components and pass only Fundamental components. The PI controller estimates the magnitude of peak reference current I max and controls the dc side capacitor voltage of cascaded multilevel inverter. It transferred by the function which is represented as, H(s )=K p +K I /s (c)triangular carrier current controller Fig5: Triangular carrier current controller The triangular carrier current controller is one of the familiar methods for active power filter applications to generate gate control switching pulses of the voltage source inverter. To determine the switching transitions by means the error current [desired reference current (ia*) compared with the actual source current (ia)] is multiplied with proportional gain (Kp). The output signal of the proportional gain is compared with triangular carrier signal. The four triangular signals are generated same frequency with different amplitude for cascaded multilevel inverter, because each phase in one converter does not overlap other phase shown in Figure 5. Thus the switching frequency of the power transistor is equal to the frequency of the triangular carrier signal. V. EXPERIMENTAL RESULTS The performance of the proposed SRF controller based cascaded active filter is evaluated through Matlab/Similink power tools. The system parameters values are; Line to line source voltage is 440 V; System frequency (f) is 50 Hz; Source impedance of LS is 1 mh; Filter impedance of Rc, Lc is 0.1 Ω; 1 mh; diode rectifier RL, LL load: 20 Ω; 100 mh; DC side capacitance (CDC) is 2100 μf; Reference voltage (VDC, ref) is 700v. 18

Fig:6 simulation results for SRF based APF before compensation (a) source current or load current before compensation. (b ) p.f before compensation. Fig:7 Simulation results for SRF based APF after shunt compensation (a)source current after shunt compensation (b). P.F of the system after shunt compensation.(c). capacitor voltage (d) Compensation current. 19

Fig 7 SRF based cascaded APF; Order of harmonics (a) the source current without active filter (THD=19.45%), (b) with active filter(thd=3.35%). The total harmonic distortion (THD) measured at the source(current) on the distribution system and the various parameters measured without APF and with APF are presented in Table 1 parameter Source current(isa) with out APF Source current(isa) with APF Power factor 0.707 0.9659 Real power 9.8KW 16KW Reactive volt Ampers 6.3KVAR 5.8KVAR THD 19.45% 3.35% Table1: Measurement of various parameters for SRF based APF with and without compensation After providing the shunt compensation THD is reduced to 3.35% which is with in the permissible limits. VI. CONCLUSION In this paper, the control strategy of the active power filter using multiple voltage-source converters was proposed on the basis of synchronous reference frame theory. SRF is employed to extract the fundamental component from the nonlinear load currents. This controller is developed by sensing load currents only. This approach is fairly simple to implement and gives better compensation characteristics. From the viewpoint of the initial and running cost, the active power filter is inferior to the passive power filter, i.e., the LC power filter at present. It is, however, most suitable to apply the active power filter to the suppression of the harmonic components present in the input current of large-capacity cycloconverters, because it is difficult for the passive power filter to eliminate their harmonic components having various frequencies. REFERENCES [1]. S.J.Huang and J.C.Wu Design and operation of cascaded active power filters for the reduction of harmonic distortions in a power System IEE Proc.-Gener Trans Distrib.Vol.146,No.2, pp.193-199, March 1999. [2]. S.Bhattacharya, T.M.Frank, D.M.Divan and B.Banerjee Parallel active filter system implementation and design issuses for utility interface of adjustable speed drive systems IEEE Conference, pp. 1032-1039, 1996. [3]. Subhashish Bhattacharya Deepak Divan Synchronous frame based controller implementation for a hybrid series active filter system IEEE-conference paper pp. 2531-40, 1995. [4]. Fang Zheng Peng, John W. McKeever, and Donald J. Adams A Power Line Conditioner Using Cascade Multilevel Inverters for Distribution Systems IEEE Trans on Indu. Appl. Vol.34,No.6,pp.1293-98,1998. 20