For all Davis weather consoles including Vantage Pro2,

Similar documents
F AN-ASPIRATED W IRELESS T EMPERATURE/HUMIDITY S TATION

WIRELESS TEMPERATURE S TATION I NSTALLATION MANUAL

Desk/Wall-Mount Rack

S OLAR RADIATION S HIELD MANUAL

19 to 39 TV WALL MOUNT - FULL MOTION

EDGE2 DUAL MONITOR ARM

ASSEMBLY AND ADJUSTMENT

2 ADULTS REQUIRED FOR ASSEMBLING

F l a t S c r e e n A R M S I n s t a l l a t i o n

INSTALLATION INSTRUCTIONS HEAVY DUTY TILT WALL MOUNT Model: PPH-2000

TOOLS REQUIRED FOR ASSEMBLY. Rubber Mallet or Plastic Tip Hammer PARTS REQUIRED FOR ASSEMBLY OF SINGLE ENTRY STARTER.

2 ADULTS REQUIRED FOR ASSEMBLING

DX-TVMLPTB03. Low-Profile TV Wall Mount ASSEMBLY GUIDE. For either wood-stud or concrete wall installations

Showpiece Cabinet Integrated Stand For 32" - 52" LCD HDTV

TITAN2-EDGE Public Access Computer Station Dual Track

Powerware Series. Eaton Rail Kit 9- and 12-Slot Cabinets Installation Guide

Copyright Black Box Corporation. All rights reserved Park Drive Lawrence, PA Fax

Arc Trainer Main Frame Assembly

Heavy-Duty Bypass Track System

ADULT ASSEMBLY REQUIRED

TV WALL MOUNT ASSEMBLY GUIDE RF-TVMLPT01V2

Universal flat-panel mount

LCD LIFT Flat Panel Display System Installation Manual. Table of Contents

Standard Pole Mount Parabolic Antenna Mounting Instructions 3 ft. (90cm) & 4 ft. (120cm)

Installation Instruction

Whalen Furniture Mfg. Factory No. 5 Page # 1

ADULT ASSEMBLY REQUIRED DUE TO THE PRESENCE OF SMALL PARTS, SHARP POINTS, SHARP EDGES

Sentinel Electronic Safe Installation Guide

SAM. Model: STV-C65 LCD Mobile Visualized Stand Instruction Manual. Weight Capacity: 1251bs / 56.7kg Suits LCD Flat Panel Display: 42"-55" Page 20

GlideRite Retractable Cover System For Hot Spot Spas (SE & SLX only)

ASSEMBLY INSTRUCTIONS MANUAL

P a r k c o n s o l e s i n k a s s e m b l y i n s t r u c t i o n s

SINCE 1922 P UBLICATION N O

Mounting Accessories. Installation Guide. VIVOTEK SD83XXE Speed Dome

O-Sullivan King 4 Poster Bed O-Sullivan Queen 4 Poster Bed Parts and Hardware List

Universal flat-panel mount

PFW 6851 Display Wall Mount, Turn & Tilt 80 kg INSTALLATION INSTRUCTIONS

MPA-9000 Universal Ceiling Projector Mount Kit

DUAL ADJUSTABLE PULLEY IP-D9302 INSTALLATION INSTRUCTIONS

GlideRite Retractable Cover System For HotSpring & Tiger River Spas (except Classic & pre-2000 Landmark Spas)

SM-RAZOR-F-M/L/XL. Strong Low Profile Fixed Mount for Ultra-Thin Flat-Panel TVs INSTALLATION MANUAL

C PART LIST HARDWARE LIST. Kitchen Cart IMPORTANT NOTE

RBP-1215B-RX DODGE RAM QUAD CAB RX3

ECM Installation Guide Installationsanleitung, Guía de Instalacíon, Guida de Installazione, Guide d Installation, Installatie gids

ATLANTIS RAIL Contact Information

Installation Instructions. Walk-in Shower Screen. with 180 Return Panel

13MM FLAT WRENCH FOR LEVELING THE GLIDES OF STRUCTURE 6MM ALLEN KEY FOR ROOF CLIPS PHILLIPS HEAD BIT FOR SCREWS FOR DOOR FRAME

LOFT DOOR HANGER BARN DOORS & HARDWARE. Hardware Installation Instructions. Page

Installing the Profile Privacy Panel. Assemble top mounting bracket. Prerequisites. Tools

BBULTRA Basketball Tower Installation

STEP 1 STEP 2 LEVELER KIT OPTION MOBILE CASTER KIT OPTION

OB1U INSTALLATION INSTRUCTIONS. Interactive Flat Panel Over White Board Mount

INSTALL INSTRUCTIONS WELCOME TO THE NEWAGE PERFORMANCE CABINETRY SERIES NEWAGE STEEL WELDED CABINETRY

Shelf Converter Drawer System

Arlink 7000 Workstation

Install Instructions. NewAge Steel Welded Tall Locker

PART #MSP-DCCST Flat Panel Tilt Mount

Pleated Shades with Corded Top Down / Bottom Up Option

GroundControl. Follow instructions contained in this manual. Incorrect installation could result in serious injury or damage to property.

LAN Locker Adjustable Shelves

INSTALLATION INSTRUCTIONS

Installation Guide. Mounting Kit for Mounting Philips Avalon CTS Cordless Fetal Transducer System on Wall, 2'' Post, Rail, or Slide-on Mounting Plate

PRO / PL SHOE REPLACEMENT & CONVERSION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

**MOUNTING YOUR MONITOR

SmartView Mounting Frame 3 Wide x 3 Deep Video Wall Display Installation Guide

INSTALLATION INSTRUCTIONS

Heavy Duty I-Beam Trolley

How To Measure Your Finished Opening

INSTALLATION INSTRUCTIONS FOR VERTICAL ROD ASSEMBLY, MODEL VRA-143

INSTALLATION MANUAL PBC-UMS

FREE CLIMBER 4400 ASSEMBLY INSTRUCTIONS 27694B

4099T Parts List. Front Bow Assy. (1) Rear Bow Assy. (1) Long Mounting Rail (2) Short Mounting Rail (2)

3 wide x 3 deep Video Wall Display Installation Guide

Constable Oak Extension Dining Table

ASSEMBLY AND ADJUSTMENT

Installation Guide PMWT-660/680. Projector Wall Mount

AUTOMATIC ADVANCE MANUAL

INSTALLATION INSTRUCTIONS MAIN BAR TIPO B 90002, 91002, 91502, 92002, 93002, 94002, 95002, 96002, y PS / B / C


6MM ALLEN KEY FOR ROOF CLIPS PHILLIPS HEAD BIT FOR SCREWS FOR DOOR FRAME SPIRIT/LASER LEVEL TO LEVEL THE UNIT

Extensive cable management on a footprint that fits on a 24-inch floor tile.

e997 Articulating Wall Arm MANUAL IM004-03

ShorePort PWC Lift Instructions " x 138" Sandstone ShorePort " x 138" White ShorePort " x 138" Tan ShorePort

Assembly Instructions Nevins Phone Booth

PFW Installation Guide Installationsanleitung, Guía de Instalacíon, Guida de Installazione, Guide d Installation, Installatie gids

Instruction sheet -- VTI Flat panel TV cart


Medium HoneyBadger Chase Rack Installation Instructions

INSTALLATION INSTRUCTIONS

PFW 6875 Installation Guide Installationsanleitung, Guía de Instalacíon, Guida de Installazione, Guide d Installation, Installatie gids

SM-RAZOR-T-M/L/XL. Strong Low Profile Tilt Mount for Ultra-Thin Flat-Panel TVs INSTRUCTION MANUAL

INSTALLATION INSTRUCTIONS Flat Panel Static Wall Mount Model: GSM-111

ADULT ASSEMBLY REQUIRED DUE TO THE PRESENCE OF SMALL PARTS, SHARP POINTS, SHARP EDGES

Installing Brackets to Minimize Distortion in Your SMART Board 685ix Interactive Whiteboard System s Projected Image

ROCKWELL. Two Panel Door. Half X Door. Double X Door. Z Combination Door

#916 CLASSIC 16 GUN CABINET ASSEMBLY INSTRUCTIONS

PERSONAL RECORD KEEPING

FIGURE 1, TYPE B Active leaf opens both doors. Overlap plates installed on the inactive

Bulkhead Model Number and

Transcription:

USR MANUAL Universal Shelter For all Davis weather consoles including Vantage Pro2, Vantage Pro2 Plus R, Vantage Vue, nvoy 8X, and Weather nvoy Product Number 6618 R Davis Instruments, 3465 Diablo Avenue, Hayward, CA 94545-2778 U.S.A. 510-732-9229 www.davisnet.com

Welcome to Universal Shelter (product no. 6618) The Universal Shelter allows you to shelter your Vantage Pro2 or Vantage Vue console, or your Weather nvoy or nvoy8x for remote or field installations. It has been carefully designed to allow for the mounting of all Davis weather station consoles and nvoys, and can be used with Solar Power Kits. The weather resistant housing can also be used to house batteries or other field equipment. Contents of Package Weather-Resistant Housing U-Bolts 1/4" Lock Washers 1/4" Hex Nuts 1/4" x 1 1/4" Lag Screws Backing Plates 2 Split Grommets, (with oval cable opening) #6 ½ Pan Head Philips Screws The package contains the following: Weather-proof shelter Hardware kit (as shown) Tools for Setup Adjustable wrench or 7/16 wrench Drill and 3/16 (5 mm) drill bit (if mounting on a vertical surface) Phillips head screwdriver 1

Install the console or nvoy in the shelter Note: You may mount the shelter before installing the console or nvoy. However, it may be easier to do this at a workbench rather than in the field. The shelter has been designed to fit Davis consoles. Inside the shelter, outlines of the Vantage Pro2 console, Vantage Vue console, and nvoy will indicate where they will be mounted in the shelter. 1. Before mounting a Vantage Vue console, remove the kickstand. Before mounting a Vantage Pro2 console or nvoy, point the antenna down. 2. The holes to use for mounting your console or nvoy are marked: for Vantage Pro2 console, for Vantage Vue console, and for nvoy, as shown below. NVOY Vantage VU Vantage PRO2 NVOY Vantage VU Vantage PRO2 Outline and screw holes for mounting a Vantage Vue Console. Outline and screw holes for mounting a Vantage Pro2 Console. NVOY Vantage VU Vantage PRO2 Outline and screw holes for mounting a Weather nvoy or nvoy8x 3. Screw the two 1/2 pan head screws into the correct holes. The depth of the hole has been specifically designed so that the screw will bottom out at the correct depth. Note: You may need to adjust the screw height for proper fit. 4. Using the keyholes on the back of the console or nvoy, slide the console or nvoy onto the screws and move it down to lock into position. 5. Close and lock the shelter. 2

Routing Cables from the Shelter If you mount a cabled console or nvoy in the shelter, or are using the shelter with a Solar Power Kit, or otherwise need to route cables from inside the shelter, follow these steps: 1. Remove one of the rubber plugs from the floor of the shelter. 2. Feed the cable down through the hole. 3. Outside the shelter, wrap a split grommet around the cable. 4. Push the grommet securely into the hole in the floor of the shelter. Using the Universal Shelter with a Solar Power Kit Use oval-hole gromment with flat cables or power cable. For some installations, you will need both a Solar Power Kit and a Universal Shelter. For example, if you wish to power a cabled Vantage Pro2 console, you will need a Heavy Duty Solar Power Kit. However, there is not enough room in the kit s shelter for both the large battery and the console. You will need to mount your console in a Universal Shelter and connect it to the Heavy Duty Solar Power Kit. 1. Install the console in the Universal Shelter. 3

2. Remove the plug from one of the holes in the floor of the Universal Shelter. Wrap the split oval grommet around the console power cable and feed it up through the hole. Insert the grommet snugly into the hole. 3. Plug the power cable into the console. 4. You may want to mount the two shelters at this point, within cable-length (the console power cable that comes with the Heavy Duty Solar Power Kit is 10' [3 m] long) of each other. See Mounting the Universal Shelter (page 4). See your Solar Power Kit User Manual for information on installation. 5. Remove the plug from one of the holes on the floor of the Heavy Duty Solar Power Kit shelter. 6. Wrap a split-oval grommet around the other end of the console s power cable and feed it up through the hole in the Heavy Duty Solar Power Kit shelter. Insert the grommet snugly into the hole. 7. Plug the power cable into the console power plug on the charging circuit.(see your Solar Power Kit User Manual.) 8. Close both shelters and lock them. Mounting the Universal Shelter Choose a location for your shelter. It can be mounted on a pole or a flat surface such as a wall or a wooden post. Mounting on a Pole Mount the shelter onto a pole or pipe with an outside diameter of 0.84'' to 1.84'' (21 mm to 27 mm) using the U-bolts, backing plates, washers, and hex nuts provided. Note: For mounting on larger diameter pipes, the housing can accommodate U-bolts with 5/6'' (8 mm) threads for pipes up to 2.40'' (61 mm) outside diameter (not provided). 4

1. While holding the shelter against the pole, place a U-bolt around the pole and through the two holes at the top of the shelter. 2. Place a backing plate, a washer, and a hex nut on each of the bolt ends. 3. Tighten the nuts using an adjustable wrench or 7/16'' wrench. 4. Place the second U-bolt around the pole and through the two holes at the bottom of the shelter. Put a backing plate, a washer, and a hex nut on each bolt end, and tighten the hex nuts. Mounting on a Post or Flat Surface Attach the shelter to the mounting surface in the desired location using the large screws and backing plates as shown below. Use a pencil or a center-punch to mark the location of the pilot hole. 1. With a 3/16'' (5 mm) drill bit, drill two holes approximately 2"(50 mm) apart. Use a carpenter s level to ensure the holes will be level. 2. Drill two more holes 7-1/32'' below the upper holes. 3. Insert the 1/4'' x 1-1/2'' lag screws through the washers, backing plates, and through the holes at the top of the shelter into the post. 4. Using an adjustable wrench or 7/16'' wrench, tighten the lag screws. 5. Repeat steps 3 and 4 for the bottom of the shelter. 5

Contacting Davis Technical Support For questions about installing or operating your Universal Shelter, please contact Davis Technical Support. We ll be glad to help. Online -mail www.davisnet.com See the Weather Support section for copies of user manuals, product specifications, application notes, software updates, and more. support@davisnet.com Telephone (510) 732-7814 Monday - Friday, 7:00 a.m. - 5:30 p.m. Pacific Time. Note: Please do not return your unit for repair without prior authorization. Specifications Housing Material.................Rugged ASA Plastic Dimensions (width x length x height)..13.75 X 10 X 4.15 inches; 34.9 X 25.4 X 10.5 cm Weight.........................2.30 lbs.; 1.04 kg Universal Shelter Product Number 6618 Document Number: 07395.328 Rev. A, February 6, 2013 Vantage Pro, Vantage Pro2, Vantage Vue, nvoy8x, and Weather nvoy are trademarks of Davis Instruments Corp., Hayward, CA. Davis Instruments Corp. 2012. All rights reserved. Information in this document subject to change without notice. Davis Instruments Quality Management System is ISO 9001 certified. 3465 Diablo Avenue, Hayward, CA 94545-2778 U.S.A. 510-732-9229 Fax: 510-732-9188 -mail: info@davisnet.com www.davisnet.com