Keysight Technologies Make Better AC RMS Measurements with Your Digital Multimeter. Application Note

Similar documents
Make Better AC RMS Measurements with your Digital Multimeter APPLICATION NOTE

Make Better RMS Measurements with Your DMM. Application Note 1392

Keysight Technologies

Keysight Technologies Migrating Balanced Measurements from the

Keysight Technologies 8490G Coaxial Attenuators. Technical Overview

Keysight Technologies

Keysight Technologies Simultaneous Measurements with a Digital Multimeter

Keysight Technologies Measuring Low Current Consumption with a Digital Multimeter

Keysight Technologies Accurate NBTI Characterization Using Timing-on-the-fly Sampling Mode. Application Note

Keysight Technologies Improving Test Efficiency of MEMS Electrostatic Actuators Using the E4980A Precision LCR Meter.

Keysight Technologies Improving the Test Efficiency of MEMS Capacitive Sensors Using the E4980A Precision LCR Meter.

Keysight Technologies How to Easily Create an Arbitrary Waveform Without Programming. Application Note

Keysight Technologies Making Simpler DC Power Measurements with a Digital Multimeter

Keysight Technologies FFT and Pulsed RF Measurements with 3000T X-Series Oscilloscopes. Application Note

Keysight Technologies Making Field Effect Transistor Characterization Using SMU

Keysight Technologies N4983A Multiplexer and Demultiplexer. Data Sheet

Keysight Technologies Differences in Application Between Power Dividers and Power Splitters. Application Note

Keysight Technologies N9310A RF Signal Generator

Keysight Technologies Understanding the Importance of Maximum Power Point Tracking Efficiency for Solar Inverters.

Keysight Technologies Precise Low Resistance Measurements Using the B2961A and 34420A

Keysight Technologies Using a Scope s Segmented Memory to Capture Signals More Efficiently. Application Note

Keysight Technologies Precise Current Profile Measurements of Bluetooth Low Energy Devices using the CX3300. Application Brief

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide

Keysight HMMC-1002 DC 50 GHz Variable Attenuator

Keysight Technologies N4985A System Amplifiers

Keysight Technologies Measuring Group Delay of Frequency Converters with Embedded Local Oscillators. Application Note

Keysight Technologies N6850A Broadband Omnidirectional Antenna. Data Sheet

Keysight Technologies N2792A/N2818A 200 MHz and N2793A/N2819A 800 MHz Differential Probes. Data Sheet

Keysight Quickly Generate Power Transients for Testing Automotive Electronics. Application Note

Keysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview

Keysight Technologies Network Analyzer Measurements: Filter and Amplifier Examples. Application Note

Keysight Technologies Accurate Capacitance Characterization at the Wafer Level

Keysight Technologies 423B, 8470B, 8472B, 8473B/C Low Barrier Schottky Diode Detectors

Keysight Technologies Maximizing the Life Span of Your Relays

Keysight 8474B/C/E Planar-Doped Barrier Diode Detectors 0.01 to 50 GHz. Data Sheet

Keysight N8836A PAM-4 Measurement Application For Infiniium S-Series, 90000A, V-Series, X-Series, Q-Series, and Z-Series Oscilloscopes

Keysight N9311X RF and Microwave Accessory Kit for Low-cost Handheld and Benchtop Solutions. Technical Overview

Keysight Technologies MATLAB Data Analysis Software Packages

Keysight Technologies MEMS On-wafer Evaluation in Mass Production

Keysight DSOXT3FRA/DSOX4FRA/DSOX6FRA Frequency Response Analyzer (FRA) Option

Introduction. Part 1. Introduction...2

Keysight Technologies HMMC GHz High-Gain Amplifier

Keysight E5063A ENA Vector Network Analyzer

Keysight Technologies Using an External Trigger to Generate Pulses with the B2960A

Keysight Technologies Automated Receiver Sensitivity Measurements Using U8903B. Application Note

Keysight Technologies P9400A/C Solid State PIN Diode Transfer Switches

Keysight Technologies Split Post Dielectric Resonators for Dielectric Measurements of Substrates. Application Note

Keysight Technologies Waveguide Power Sensors. Data Sheet

Keysight Technologies How to Read Your Power Supply s Data Sheet. Application Note

Keysight Technologies Using a Network and Impedance Analyzer to Evaluate MHz RFID Tags and Readers/Writers

Keysight N9310A RF Signal Generator

Keysight Technologies VSA Software for Simulation Environments BE/89601 BNE

Keysight Technologies USB Preamplifiers

Keysight Technologies N9398C/F/G and N9399C/F DC Block. Technical Overview

Keysight Redefines 50 GHz Portability. Get a $30k Credit When You Move Up to FieldFox

Keysight U1882B Measurement Application for Infiniium Oscilloscopes. Data Sheet

Keysight Technologies Migrating from the 4268A/4288A Capacitance Meter to the E4981A Capacitance Meter. Technical Overview

Keysight Technologies Overcoming LTE-A RF Test Challenges. Application Note

Keysight Technologies U1210 Series Handheld Clamp Meters

Keysight Technologies Triggering on and Decoding the PSI5 Sensor Serial Bus

Keysight N8803C CAN, LIN, FlexRay, and CAN-FD Protocol Triggering and Decode Software. Data Sheet

Keysight Technologies 89601B-SSA/89601BN-SSA Spectrum Analysis VSA Software

Keysight Technologies Automotive ECU Transient Testing Using Captured Power System Waveforms. Application Note

Keysight Technologies Power of Impedance Analyzer

Keysight Technologies 7 Hints That Every Engineer Should Know When Making Power Measurements with Oscilloscopes. Application Note

Keysight Technologies InfiniiScan Event Identification Software

Keysight Technologies Optimizing RF and Microwave Spectrum Analyzer Dynamic Range. Application Note

Keysight Technologies N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes. Data Sheet

Keysight Technologies Achieving Accurate RF and Microwave Power Measurements for Satellite Thermal Vacuum Test. Application Note

Keysight E5063A ENA Series Network Analyzer

Keysight Technologies Direct Power MOSFET Capacitance Measurement at 3000 V

Keysight M9485A PXIe Multiport Vector Network Analyzer

Keysight Technologies How to Take Fast, Simultaneous Measurements of Two or More Signals Using BenchVue Software. Application Note

Keysight N2806A Calibration Pulse Generator The world s fastest differential pulse generator. Data Sheet

Keysight M940xA PXIe Optical Extenders for Instrumentation. Data Sheet

Keysight Technologies Accurate Evaluation of MEMS Piezoelectric Sensors and Actuators Using the E4990A Impedance Analyzer.

Keysight Technologies How to Select the Right Current Probe. Application Note

Keysight Technologies Alliance for Wireless Power (A4WP) Measurements Using an Oscilloscope (Part 3)

Keysight Technologies Improve the Accuracy and Efficiency for Organic-Thin Film Transistor (Organic-TFT) Characterization

Keysight Technologies N9398C/F/G and N9399C/F DC Block. Technical Overview

Keysight Technologies How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer.

Keysight Technologies

Keysight Technologies N2750A/51A/52A InfiniiMode Differential Active Probes. Data Sheet

Keysight Technologies Electronic Calibration (ECal) Modules for Vector Network Analyzers

Keysight Technologies RF & Microwave Attenuators. Performance you can count on

Keysight Technologies Wide Range DC Current Biased Inductance Measurement

Keysight Technologies Phase Noise X-Series Measurement Application

Keysight Technologies VOR and ILS Radio Navigation Receiver Test Using Option 302 for Keysight Signal Sources. Application Note

Keysight Technologies Making Current-Voltage Measurement Using SMU

Keysight Technologies CAN, LIN and FlexRay Protocol Triggering and Decode for Infiniium 9000 and S-Series Oscilloscopes.

Keysight Technologies Active Differential Probes U1818A 100 khz to 7 GHz U1818B 100 khz to 12 GHz. Technical Overview

Keysight Measuring High Impedance Sources Using the U8903B Audio Analyzer. Application Note

Keysight Technologies PNA Receiver Reduces Antenna/RCS Measurement Test Times

Keysight N6780 Series Source/Measure Units (SMUs) for the N6700 Modular Power System

Keysight Technologies, Inc. UWB Antenna Measurements with the 20 GHz E5071C ENA Network Analyzer. Application Note

Keysight Technologies How to Perform QSCV (Quasi-Static Capacitance Voltage) Measurement

Keysight Technologies 1 mw 50 MHz Power Reference Measurement with the N432A Thermistor Power Meter. Application Note

Keysight Technologies UXG X-Series Agile Signal Generator, Modified Version N5191A

Keysight Technologies N6141A & W6141A EMI X-Series Measurement Application. Technical Overview

Keysight Technologies HMMC-3002 DC-16 GHz GaAs HBT MMIC Divide-by-2 Prescaler

Transcription:

Keysight Technologies Make Better AC RMS Measurements with Your Digital Multimeter Application Note

Introduction If you use a digital multimeter (DMM) for AC voltage measurements, it is important to know what type of reading your meter is giving you so that you can properly interpret the results. Is your meter is giving you peak value, average value, root-mean-square (RMS) value, or something else? If the answer is something else, you may be in trouble, and the trouble usually happens with AC rms measurements. This application note will help you understand the different techniques DMMs use to measure rms values, how the signal affects the quality of your measurements, and how to avoid common measurement mistakes. 2011 NCSL International Workshop and Symposium

03 Keysight Make Better AC RMS Measurements with Your Digital Multimeter - Application Note Measuring AC RMS Measuring AC rms values is more complicated than it appears at first glance. If it is complicated, why do we bother? Because true rms is the only AC voltage reading that does not depend on the shape of the signal. It often is the most useful measurement for real-world waveforms. Often, rms is described as a measure of equivalent heating value, with a relationship to the amount of power dissipated by a resistive load driven by the equivalent DC value. For example, a 1 sine wave will deliver the same power to a resistive load as a 0.707V dc signal. A reliable rms reading on a signal will give you a better idea of the effect the signal will have in your circuit. The scaling factors apply only to pure sine waves. For every other type of signal, using this approach produces misleading answers. If you are using a meter that is not really designed for the task, you easily can end up with significant error as high as 40 percent or more depending on the meter and the signal. The ratio of to V rms known as the crest factor, is important to measurement accuracy. The crest factor is a measure of how high the waveform peaks, relative to its RMS value. The higher the crest factor, the more difficult it is to make an accurate AC measurement. Two measurement challenges are associated with high crest factors. The first involves input range. Imagine a pulse train with a very low duty cycle but a relatively high peak amplitude. Signals like this force the meter to simultaneously measure a high peak value and a much lower rms value, possibly creating overload problems on the high end and resolution problems on the low end. The second challenge is the amount of higher-frequency energy in the signal. In general, high crest factors indicate more harmonics, which can cause trouble for all meters. Peak- and average-responding meters that are trying to measure rms have a particularly hard time. Figure 1 shows four common voltage parameters. Peak voltage ( ) and peakto-peak voltage (-pk ) are simple. V avg is the average of all the instantaneous values in one complete cycle of the waveform. You will learn how we calculate V rms below. For sine waves, the negative half of the waveform cancels out the positive half and averages to zero over one cycle. This type of average would not provide much insight into the signal s effective amplitude, so most meters compute V avg based on the absolute value of the waveform. For a sine wave, this works out to x 0.637 (Figure 2). Volume Figure 1. Common voltage parameters Time V avg V rms -pk You can derive V rms by squaring every point in the waveform, finding the average (mean) value of the squares, then finding the square root of the average. With pure sine waves, you can take a couple of shortcuts: just multiply x 0.707 or V avg x 1.11. Inexpensive peak-responding or average-responding meters rely on these scaling factors. Volume V avg Time Figure 2. V avg is calculated based on the absolute value of the waveform.

04 Keysight Make Better AC RMS Measurements with Your Digital Multimeter - Application Note Tips for Making Better AC RMS Measurements Given the importance and difficulty of measuring rms, what is the best way to proceed with your day-to-day measurement tasks? The following tips will help you achieve better results. Tip 1: Understand how your DMM measures rms. When it comes to measuring rms values, multimeters are not created equal. A general understanding of the technology your multimeter uses to measure rms will help you decide if it meets your needs. Here is a summary of the operational advantages and disadvantages of four common multimeter technologies. The first three operate by converting AC to DC; the last one digitizes the analog input signal and then computes rms. Thermal AC-to-DC converters This older technology for rms measurements uses the equivalent-heating-value approach. The AC signal heats a thermocouple, then the DC section of the meter reads the thermocouple output. Advantages include wide bandwidth and the ability to handle very high crest factors, meaning this approach can deliver true rms for a wide variety of real-world signals. The disadvantages of the thermal approach are cost and lack of flexibility in trading off measurement speed with low-frequency accuracy. For these reasons, the technique is not used in the latest-generation DMMs. If you need to measure high-bandwidth and high-crest-factor signals with great accuracy, you may want to search for one of these thermal models. If high accuracy is important to you, you may want to investigate multimeters that use the digital sampling method. Peak and averaging AC-to-DC converters Inexpensive meters, particularly inexpensive hand-held meters, usually derive rms levels from either peak or average values. They deliver true rms only for pure, undistorted sine waves. If you need true rms measurements on real-world signals, these meters are not a viable option. Analog AC-to-DC converters Many mid-range DMMs use a chain of analog circuits to compute the square, then the mean, then the square root of the mean to deliver true rms for nearly all signal types.

05 Keysight Make Better AC RMS Measurements with Your Digital Multimeter - Application Note Digital sampling This last method uses sampling techniques similar to those in digital oscilloscopes to create a set of data points that are sent through an rms algorithm. Synchronous sampling uses multiple passes to capture a signal as shown in Figure 3. Each subsequent pass is delayed by a small amount, and with enough passes, the signal can be digitized with very high resolution. This technique has several advantages: true rms on a wide range of signals, high accuracy, and the capability to create very fast, effective sampling rates and wider bandwidths, even with fairly slow analog-to-digital converters. This method, however, only works with repetitive signals. If accurate rms measurements are important to you and you are likely to run into pulse trains and other complicated signals, a true rms meter is the only solution. On the other hand, you can save some money with a peak or average-responding meter. Just keep in mind what these meters can and cannot do. Tip 2: Understand how the signal affects the quality of your measurement. Let s look at several different signals, starting with a sine wave. The crest factor for a pure sine wave is 1.414, and a peak-responding meter can provide accurate rms simply by scaling the value of. With a value of 500 mv, we expect an rms value around 350 to 357 mv (the range accounts for the inaccuracy of the signal generator used). Sure enough, a true rms meter reads the signal as 353.53 mv. A less-expensive average-responding meter reads the signal as 351 mv. Unlike the pure sine wave, the triangle wave in Figure 4 has some higher-frequency energy, so the crest factor of 1.732 comes as no surprise. Dividing the peak value by the crest factor yields an expected rms value of roughly 290 mv. Now, the average-responding meter starts to get into trouble, reading the signal as 276 mv, a 4 percent error compared to the true rms meter s reading of 288.68 mv. 2nd Trigger Point 1st Trigger Point Now let s look at pulse trains, where the crest factor depends on the duty cycle. You can get a close approximation of crest factor with the formula: Figure 3. Digital sampling CF T t where: CF = the crest factor T = the period of the waveform t = the on portion of that period Figure 4. Measuring rms on a triangle wave

06 Keysight Make Better AC RMS Measurements with Your Digital Multimeter - Application Note This also is equal to the square root of the reciprocal of the duty cycle. So, for the pulse train in Figure 5, which has a 2 percent duty cycle, the crest factor is the square root of 50, or 7.071. Computing the rms value for sines and triangles is quite simple; the rms value is divided by the crest factor. However, computing the AC rms value for a pulse train is a bit more complicated: V rms Vpk 1 = 1 CF CF 2 Figure 5. Measuring rms on a low-duty-cycle pulse train Using the formula, the theoretical rms value of our 2- pulse train with 2 percent duty cycle in Figure 5 is roughly 280 mv. Even in this case, which is outside its specified performance range, the true rms meter reads 275.9 mv. On the other hand, the average-responding meter reads 73 mv, a 74 percent error. This is an extreme example, but it provides a clear picture of what high crest factors can do to your measurements. Let s consider one more waveform the noisy, messy sine wave shown in Figure 6. The true rms meter pegs it at 348.99 mv, which is close to the digital scope s measurement of 345 mv. The average-responding meter puts the value at 273 mv, an error of more than 20 percent. This error is due to the limited bandwidth of the average-responding meter. The signal contains high-frequency energy that the average-responding meter does not take into account. Figure 6. Measuring rms on a noisy sine wave

07 Keysight Make Better AC RMS Measurements with Your Digital Multimeter - Application Note Tip 3: Avoid common measurement traps. If an AC rms reading does not make sense, do not automatically assume there is something wrong with your circuit the trouble might be in how you made the measurement. Below is a list of common traps that can affect rms measurements. We have touched on some of these already, and you may have run into many of them before. Measurements below full scale Most meters specify AC inputs down to 5 percent or 10 percent of full scale (some go as low as 1 percent of full scale). For maximum accuracy, measure as close to full scale as you can. You might need to override autoscaling in some cases, if a manual setting will help maximize the input range. AC and DC coupling It is easy to overlook this simple issue when you are in a hurry. If your meter is AC coupled (or has selectable AC coupling), it inserts a capacitor in series with the input signal that blocks the DC component in your signal. This may or may not be desirable, depending on the signal and what you are trying to accomplish. If you are expecting to include the DC component, but the meter is AC coupled, the results can be dramatically wrong. As a side note, if you need to measure a small AC signal riding on a large DC offset but your meter doesn t provide AC + DC directly, you can measure the AC component using AC coupling and measure the DC component separately. Then add the two using rms addition: ( ) 2 2 AC + DC = AC + DC rms 2 Saturation problems with high-crest-factor signals In addition to the problems they cause with high-frequency content, high-crest-factor signals also can wreak havoc on your input range. Think back to that pulse train with a 2 percent duty cycle. Its 7+ crest factor means that the peak value is more than seven times greater than the rms value. That means your meter needs to provide adequate amplitude resolution for the low rms value without saturating on the high peak value. To make matters worse, you generally do not get an overload indication with crest-factor saturation, either. It is important to check your meter s specifications for maximum crest factor and to refrain from exceeding them. Bandwidth errors Signals that are rich in harmonics can produce low-reading measurements if the more significant of these components are not included in the measurement. Check the instrument s data sheet to see how much bandwidth you have to work with. Then make sure your signals do not exceed it. Self-heating errors High voltages can heat up the meter s signal-conditioning components, leading to offset measurement values. Pay attention to the maximum input voltage; if you exceed it, give the meter time to cool down before making another measurement. Settling time By definition, rms measurements require time averaging over multiple periods of the lowest frequency being measured. Consequently, if you are not concerned about low frequencies in a particular measurement and your DMM has selectable averaging filters, switch to a faster filter.

08 Keysight Make Better AC RMS Measurements with Your Digital Multimeter - Application Note Conclusion While AC rms measurements are more complicated than they might seem at first glance, a little bit of knowledge can help you deal with the complexity. If you have not already done so, verify the crest factor, bandwidth, and other limitations noted in your DMM s data sheet. As much as possible, stay within those limits. A quality meter used within its limits should deliver consistently dependable measurements. For more information about the Keysight Digital Multimeters, go to Glossary Crest factor a measure of how high the waveform peaks, relative to its rms value DMM digital multimeter rms an abbreviation for root-mean-square True rms The term true rms is used to distinguish meters that actually measure the rms value, from meters that derive rms levels from either peak or average values V avg average voltage, using the absolute value of the waveform (the negative portion of the cycle is treated as if it were positive) peak voltage Related Literature Keysight Truevolt Series of DMMs Data Sheet, 5991-1983EN -pk peak-to-peak voltage V rms the rms value of AC voltage

09 Keysight Make Better AC RMS Measurements with Your Digital Multimeter - Application Note Evolving Since 1939 Our unique combination of hardware, software, services, and people can help you reach your next breakthrough. We are unlocking the future of technology. From Hewlett-Packard to Agilent to Keysight. For more information on Keysight Technologies products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada (877) 894 4414 Brazil 55 11 3351 7010 Mexico 001 800 254 2440 United States (800) 829 4444 mykeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. http://www.keysight.com/find/emt_product_registration Register your products to get up-to-date product information and find warranty information. Keysight Services www.keysight.com/find/service Keysight Services can help from acquisition to renewal across your instrument s lifecycle. Our comprehensive service offerings onestop calibration, repair, asset management, technology refresh, consulting, training and more helps you improve product quality and lower costs. Keysight Assurance Plans www.keysight.com/find/assuranceplans Up to ten years of protection and no budgetary surprises to ensure your instruments are operating to specification, so you can rely on accurate measurements. Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight s measurement expertise and product breadth, combined with channel partner convenience. Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 11 2626 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 6375 8100 Europe & Middle East Austria 0800 001122 Belgium 0800 58580 Finland 0800 523252 France 0805 980333 Germany 0800 6270999 Ireland 1800 832700 Israel 1 809 343051 Italy 800 599100 Luxembourg +32 800 58580 Netherlands 0800 0233200 Russia 8800 5009286 Spain 800 000154 Sweden 0200 882255 Switzerland 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) United Kingdom 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-9-7-17) DEKRA Certified ISO9001 Quality Management System www.keysight.com/go/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2015 Quality Management System This information is subject to change without notice. Keysight Technologies, 2013-2017 Published in USA, November 7, 2017 5988-6916EN www.keysight.com