CALIBRATION KIT FOR EFT / BURST CAPACITIVE COUPLING CLAMP INA 3425 USER MANUAL A

Similar documents
INA 703 MAgNetIc field coil

MD 103 ESD TargET SET USEr ManUal B

MD 200A High voltage differential probe

Advanced Test Equipment Rentals ATEC (2832) INA A

CBA 400M MHZ to 400 MHZ

Nsg inductive switch transient test circuit

CDN 117 / 117-M CDN 118-T4 / 118-EXT-1 SIGNAL & DATA LINE COUPLING NETWORKS USER MANUAL M

PA Automotive battery simulators

GTEM cells. Emissions and immunity testing in a single, shielded environment

COUPLING / DECOUPLING NETWORK (CDN) CDN AF TYPE, CDN CAN

Coupling / decoupling network (CDN) for screened or coaxial cables

COUPLING NETWORK (CN) FOR IEC / EN , DC TO 150 khz

THE MODULAR SOLUTION FOR 6 KV APPLICATIONS

IEC Electrical fast transient / Burst immunity test

CONDUCTED IMMUNITY EMC TEST SYSTEM

P331-2 set ESD generator (IEC )

COUPLING DECOUPLING NETWORK MODEL CDN-AF4

NSG Hard keys for important functions. 5.7 color display, easy to use firmware. 3 power meter

Test Systems. VSQ 3000/3002 Reference Radiation Source up to 3GHz

Advanced Test Equipment Rentals ATEC (2832) EMC Calibration ServiCES. Reliable fast worldwide

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25

TEST SYSTEM FOR CONDUCTED AND RADIATED IMMUNITY

RADIATED IMMUNITY TEST SYSTEM 6 GHz

TEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27

Immunity Testing for the CE Mark

TesT system for ConduCTed and radiated immunity

TEST SYSTEM FOR CONDUCTED AND RADIATED IMMUNITY

INSTRUCTION MANUAL For LINE IMPEDANCE STABILIZATION NETWORK. Model LI khz to 10 MHz

Mhow (MP) PIN c/o 56 APO RFI : PROCUREMENT OF FAST TRANSIENT RESPONSE ELECTROMAGNETIC PULSE (EMP) SIMULATOR

Two Line V-Network GLN-5040A USER MANUAL GW INSTEK PART NO. 99 Washington Street Melrose, MA Phone Toll Free

Methods for Testing Impulse Noise Tolerance

LS200 TEST DATA IEC61000 SERIES

RIGOL. User s Guide. RP1000D Series High Voltage Differential Probe. Feb RIGOL Technologies, Inc

Schlöder GmbH - EMC Test and Measurement Systems Model #

Voltage Transient Emission Test

EN61326 EMC COMPLIANCE REPORT on the LP Series Ultrasonic Transmitter Remote Amplifier and Transducer for Hawk Measurement Systems Pty Ltd

MONITORING DEVICE 4 khz to 400 MHz

Radiated immunity test system 6 GHz

EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass

Radiated Immunity Test System 6 GHz

Harmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass

Discontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz

CAL U100B CAL U100B CDN M016 CAL U100B CDN M016 CAL U100B. Used as M2 CDN. Used as M3 CDN

Insulation Test System

CTR2 / CTR2-AD CALIBRATION TARGET AND VERIFICATION ADAPTER FOR ESD

Advanced Test Equipment Rentals ATEC (2832)

Passive High Voltage Probes P5100A-TPP0850-P5122-P5150-P6015A Datasheet

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS

Kentech Instruments Ltd. CPS3/S pulser Serial No. J03*****

TEST SYSTEM FOR CONDUCTED AND RADIATED IMMUNITY

EMC standards. Presented by: Karim Loukil & Kaïs Siala

Specification. CTR 2 ESD calibration target

Technical Specification

12604 N New Reflection Dr Marana, AZ, FAX

R&S ENV216 Two-Line V-Network For disturbance voltage measurements on single-phase EUTs

BS EN TESTS ON THE IT TOXIC GAS DETECTOR MODULE

2620 Modular Measurement and Control System

Kentech Instruments Ltd. CPS3/S/P pulser Serial No. xxxx

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 AMETEK CO., LTD. NAGOYA OFFICE. (Main Laboratory) Onna, Atsugi-shi, Kanagawa-ken, Japan

30 A AC/DC Current Probe TCP0030A Datasheet

An Introduction to EMC Testing (what can be done with scopes) Vincent Lascoste EMC Product Manager - RSF

Bulk Current Injection Probe Test Procedure

Differential Probes P6248 P6247 P6246 Datasheet

BIODEX MULTI- JOINT SYSTEM

CTR2 / CTR2-AD CALIBRATION TARGET AND VERIFICATION ADAPTER FOR ESD

Trees, vegetation, buildings etc.

KOLLMORGEN. Motion Technologies Group. EMC Installation and Application Guidelines for BDS4/5 Goldline Series MB4000H Issue 3

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University

V1.3. TBLC08 50mH AC-LISN TBLC08

ECOsine Active Increased reliability in building technology

EMC Test Facility Sale

AC/DC Current Oscilloscope Probe Model SL261

Insulation Test System

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Voltage Probe Manual and Data North Star High Voltage, Inc. Rev January 2016

CWS 500N1.4 CONTINUOUS WAVE SIMULATOR, 80W

Technical Specifications Micromedical VisualEyes 505 by Interacoustics

Passive Current Transducers for Sinusoidal Alternate Currents From A/0...5 A MCR-SLP-1/5-UI-0(-SW)

Agilent 4294A Precision Impedance Analyzer, 40 Hz to 110 MHz. Configuration Guide

COMBILOG ANTENNA MODEL AC MHz. rev: 0202

EMC Seminar Series All about EMC Testing and Measurement Seminar 1

By order of American Power Conversion Holdings Inc. at New Taipei City, Taiwan

AC/DC Current Probe TCP0150 Datasheet

EMC TEST REPORT. For. Switching Mode Power Adaptor. Model No.: 9W/14.4V/EU(18V/1.0A), 19W/14.4V/EU(12V/1.5A)

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE. ISO-STIM 01D STIMULUS ISOLATION UNIT ±100 V / ±10 ma, bipolar output

COMPACT NX5 FIRST OF ITS KIND. SHOWS ITS TRUE COLORS. THINKS FOR ITSELF.

Original operating instructions Fail-safe inductive sensor GG507S

MDS-21 Absorbing Clamp, EZ-24 Ferrite Clamp

Keysight 86205B RF Bridge

ELECTRONICS TESTING CENTER(ETC), TAIWAN

HAWK5000 Operators Manual

Kutta Radio & charger Report Number: TRE0026-5/17 Page 1 of 27 EMC TEST REPORT. TEST SAMPLE (EUT) : Kutta Medium frequency radio & Charger

Current Probes. User Manual

MANUAL. Electrostatic Field Meter EFM 120. System Prof. Dr.-Ing. Hans Kleinwächter

Model 4210-MMPC-L. Multi-measurement Prober Cable Kit. Overview. Quick start guide topics. Related documents

50 μh Line Impedance Stabilisation Network (AC LISN)

MKH 416 P 48 U. Instruction manual

Coupling/Decoupling Networks (CDN)

EMC TEST REPORT. For. Boardcon Technology Limited. MINI9G45 Computer on Module. Model No. : MINI9G45

Transcription:

1 CALIBRATION KIT FOR EFT / BURST CAPACITIVE COUPLING CLAMP INA 3425 USER MANUAL 601-339A

CALIBRATION KIT FOR EFT / BURST CAPACITIVE COUPLING CLAMP INA 3425 USER MANUAL Calibration kit for EFT / Burst Capacitive coupling clamp INA 3425

CONTENTS 1 Safety instructions 5 2 Description 7 2.1 Intended purpose 7 2.2 Preparation for operation 8 2.3 Operating 8 3 Typical waveform data 11 3.1 Typical burst wave and parameters at generator output 11 3.2 Typical burst wave and parameters at Coupling clamp output 12 4 Technical data 13 4.1 Technical parameters INA 3425 transducer plate 13 4.2 technical parameters INA 3425 termination bracket (connecting adapter) 13 5 Accessory CAS 3025 14 6 Maintenance and warranty 15 6.1 Maintenance and cleaning 15 6.2 Warranty 15 6.3 Shipping 15 7 Addresses 18

1 SAFETY INSTRUCTIONS 5 INA 3425 calibration kit for EFT / Burst coupling clamp is an accessory to be used with IEC 61000-4-4 Burst generators and coupling clamps only. These type of instruments generate high voltage peaks up to 4 or even 8 kv. User manual and safety instructions of the EFT / Burst generator needs to be followed during use of this accessory. INA 3425 together with the EFT / Burst generator and coupling clamp should only be installed and used by authorised and trained EMC specialists or calibration engineers. (electrical engineers). Personnel fitted with a heart pacemaker must not operate the instrument and must not be in the vicinity of the test rig while it is in operation. Risk of radiating electromagnetic interference. Test equipment and test setup may need to be used in a shielded environment.

6 Burst / EFT pulse are High voltage low energy pulses which will be applied to the top plate of the burst / EFT coupling clamp- It is recommended NOT to touch the top plate during the time pulses are applied. Up to pulse voltages up to ca 1 kv the user will not notice anything by getting in contact with the plates, up to 4 kv he will notice some pain similar to what one feels during an electrostatic discharge. Over 4 kv, up to 8 kv, the pain will get worse but stays undangerous for the normal human being. TESEQ recommends the use of the safety cover with Interlock for all applications using generators for more then 4 kv Burst pulses. Calibration kit for EFT / Burst Capacitive coupling clamp INA 3425

2 DESCRIPTION 7 2.1 Intended purpose The calibration kit for EFT / Bursts coupling clamps is designed for the calibration burst / EFT coupling clamps as specified in basic standard IEC 61000-4-4 Ed 3.0 : 2012 The INA 3425 consists in a transducer plate and a termination bracket (connection adapter) Fig. 1: INA 3425 transducer plate and termination bracket (connecting adapter)

8 2.2 Preparation for operation The test rig is to be constructed in accordance with IEC / EN 61000-4-4 Ed 3.0 : 2012 with special reference to: Operation preferably in a screened room to protect the environment Distances to the EUT and peripherals to be as specified in the standard Good and large area contact to the earth plane Fig. 2: Example of calibration test setup as described in IEC / EN 61000-4-4 Ed 3.0: 2012 2.3 Operating Set up Burst / EFT generator, oscilloscope and coupling clamp to calibrate on an adequate ground plane respect setup as specified in IEC 61000-4-4 Ed 3.0: 2012 Use CAS 3025 (INA 265A) to verifiy the compliance of the reference burst / EFT generator, save waveshape and register pulse parameters for reference. Place the INA 3425 into the coupling clamp to be calibrated position the whole as specified. Note that the Teseq sticker at the end of INA 3425 is placed the way that when in line with the end of the coupling clamp, the distances to the connecting adapter will automatically be < 10 cm as required by the standard. Calibration kit for EFT / Burst Capacitive coupling clamp INA 3425

- Connect the delivered HV pulse cable to the pulse output of the used EFT / Burst generator. As shown in Fig 3 9 Fig. 3: CDN 3425 connected to the EFT output of a NSG 3040 generator Connect termination bracket (connection adapter) at the other end of the coupling clamp to calibrate as shown in Fig 4 Fig. 4: connection of termination bracket (connecting adapter) Note: insure good contacting of termination bracket to ground plane

10 Connect CAS 3025 (or INA 265A 50 Ω terminator / attenuator) and oscilloscope to the termination bracket as shown in Fig 5 Fig. 5: CAS 3025 (INA 265A 50 Ω terminator / attenuator) and oscilloscope connected to termination bracket. the whole test setup might look like shown in Fig 6 Fig. 6: complete test setup for Burst / EFT coupling clamp calibration set Burst generator to 2 kv measure burst pulse waveshape and parameters at Coupling clamp output. turn the Burst coupling clamp in the other direction in order to verify / calibrate the other path, and repeat the measurements. Calibration kit for EFT / Burst Capacitive coupling clamp INA 3425

3 TYPICAL WAVEFORM DATA 11 3.1 Typical burst wave and parameters at generator output

12 3.2 Typical burst wave and parameters at Coupling clamp output Calibration kit for EFT / Burst Capacitive coupling clamp INA 3425

4 TECHNICAL DATA 13 4.1 Technical parameters INA 3425 transducer plate Metallic sheet 120 x 1050 x 0,5 mm Dielectric sheets (top and bottom) 140 x 1070 x 0,5 mm Total thikness 1,5 mm Dielectris strength (isolation) 5 kv Weight 0.3 kg approx. 4.2 technical parameters INA 3425 termination bracket (connecting adapter) Input connector Output connector Connection to ground Weight Banana SHV fits for INA 265A (CAS 3025) terminator/ attenuator Low impedance through large contacting surfaces 0,15 kg approx.

14 5 ACCESSORY CAS 3025 CAS 3025 is a Calibration set for burts / EFT. It consists of INA 265A: 50 Ω / 1000 to 1 terminator / attenuator, and of INA 266: 1000 Ω / 2000 to 1 terminator / attenuator, of a coax cable of 1 meter, RG 58, and of a traceable calibration certificate, a user manual and carring case. It is Full compliant to IEC 64000-4-4. Calibration kit for EFT / Burst Capacitive coupling clamp INA 3425

6 MAINTENANCE AND WARRANTY 15 5.1 Maintenance and cleaning Maintenance is limited to the removal of any foreign particles or objects from the surfaces since such matter can adversely affect the test parameters. In general a moist cloth is sufficient for cleaning the outer housing. In stubborn cases use a small amount of a mild, non-foaming household cleanser as well. No chemicals should be used for cleaning purposes. 5.2 Warranty Teseq grants a warranty of 24 months against material and manufacturing faults. The warranty does not cover damages due to transportation, poor packaging, and those damages caused through use of the equipment for unforeseen purposes and the effects of physical force. 5.3 Shipping Always use original Teseq packaging, make sure the various warning labels for delicate instruments are well visible.

Headquarters Teseq AG 4542 Luterbach, Switzerland T + 41 32 681 40 40 F + 41 32 681 40 48 sales @ teseq.com www.teseq.com China Teseq Company Limited T + 86 10 8460 8080 F + 86 10 8460 8078 chinasales @ teseq.com Germany Teseq GmbH T + 49 30 5659 8835 F + 49 30 5659 8834 desales @ teseq.com Singapore Teseq Pte Ltd. T + 65 6846 2488 F + 65 6841 4282 singaporesales @ teseq.com Taiwan Teseq Ltd. T + 886 2 2917 8080 F + 886 2 2917 2626 taiwansales @ teseq.com Manufacturer Teseq AG 4542 Luterbach, Switzerland T + 41 32 681 40 40 F + 41 32 681 40 48 sales @ teseq.com France Teseq Sarl T + 33 1 39 47 42 21 F + 33 1 39 47 40 92 francesales @ teseq.com Japan Teseq K.K. T + 81 3 5725 9460 F + 81 3 5725 9461 japansales @t eseq.com Switzerland Teseq AG T + 41 32 681 40 50 F + 41 32 681 40 48 sales @ teseq.com UK Teseq Ltd. T + 44 845 074 0660 F + 44 845 074 0656 uksales @ teseq.com USA Teseq Inc. T + 1 732 417 0501 F + 1 732 417 0511 Toll free +1 888 417 0501 usasales @ teseq.com To find your local partner within Teseq s global network, please go to www.teseq.com July 2012 Teseq Specifications subject to change without notice. Teseq is an ISOregistered company. Its products are designed and manufactured under the strict quality and environmental requirements of the ISO 9001. This document has been carefully checked. However, Teseq does not assume any liability for errors or inaccuracies.